Ramazan Tufan Erdogan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ramazan Tufan Erdogan has a total of 83 co-authors. Here are the top co-authors by number of shared publications:
- Peter Gerard Steeneken
Delft University of Technology
4 shared publications - Bruno Lopez-Rodriguez
Department of Imaging Physics (ImPhys), Faculty of Applied Sciences Delft University of Technology Delft The Netherlands
3 shared publications - Iman Esmaeil Zadeh
Department of Imaging Physics, Delft University of Technology 1 , 2628 CN Delft
3 shared publications - Wouter J. Westerveld
Department of Precision and Microsystems Engineering, Faculty of Mechanical Engineering, Delft University of Technology, Delft, The Netherlands
3 shared publications - Cenk Yanik
SUNUM, Nanotechnology Research and Application Center, Sabanci University 4 , Istanbul 34956, Turkey
2 shared publications - Gerard Jan Verbiest
Delft University of Technology
2 shared publications
Latest Publications
- Open Access
- 17 February 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (4) , 6721-6735
Elasto-optic transduction in polymer-cladded silicon microring arrays for real-time 2D force mapping
Real-time mapping of small forces with micrometer resolution is essential for studying soft and biological matter. However, existing techniques are slow, limited in spatial sampling or require non-planar substrates that can perturb cell behavior. Here we present silicon sensor arrays for rapid surface force mapping that operate using the elasto-optically induced wavelength shift in thin polymer-cladded optical ring resonators. Using a nano-indenter, we demonstrate that the sensor array reaches a force resolution down to 12 μN and shows a linear response. We present both a five-ring linear array and a 10×5 two-dimensional array at 15 μm pitch, and demonstrate the feasibility of localization and force mapping of a spherical nanoindentation tip. Combined measurement of forces by nano-indenter and the optical ring resonator sensor presents a methodology for calibrating this type of photonic force sensor. Moreover, good correspondence between measurements and finite element simulations provides evidence for the proposed operation mechanism. The shown combination of biocompatible claddings, strong opto-mechanical coupling, and foundry-ready photonics, presents a route towards scalable, real-time force mapping for soft-matter metrology, tactile interfaces, and in vitro mechanobiology.
- 17 February 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (4) , 6721-6735
Open AccessElasto-optic transduction in polymer-cladded silicon microring arrays for real-time 2D force mapping
Real-time mapping of small forces with micrometer resolution is essential for studying soft and biological matter. However, existing techniques are slow, limited in spatial sampling or require non-planar substrates that can perturb cell behavior. Here we present silicon sensor arrays for rapid surface force mapping that operate using the elasto-optically induced wavelength shift in thin polymer-cladded optical ring resonators. Using a nano-indenter, we demonstrate that the sensor array reaches a force resolution down to 12 μN and shows a linear response. We present both a five-ring linear array and a 10×5 two-dimensional array at 15 μm pitch, and demonstrate the feasibility of localization and force mapping of a spherical nanoindentation tip. Combined measurement of forces by nano-indenter and the optical ring resonator sensor presents a methodology for calibrating this type of photonic force sensor. Moreover, good correspondence between measurements and finite element simulations provides evidence for the proposed operation mechanism. The shown combination of biocompatible claddings, strong opto-mechanical coupling, and foundry-ready photonics, presents a route towards scalable, real-time force mapping for soft-matter metrology, tactile interfaces, and in vitro mechanobiology.
- Open Access
- 18 December 2025
- Published by Springer Nature in Communications Physics
- Vol. 9 (1)
Amorphous silicon-carbide photonics for ultrasound imaging
Photonic ultrasound sensors promise unparalleled spatial and temporal resolution in ultrasound imaging due to their size-independent noise figure, high sensitivity, and broad bandwidth. Optical materials can further improve performance and stability, but achieving small size, high sensitivity, and wide bandwidth remains challenging. This work introduces amorphous silicon carbide (a-SiC) for ultrasound sensing, offering strong optical confinement, low propagation loss, and high stability for miniaturized microring sensors. We demonstrate a compact detection system with a 20-transducers linear array coupled to a single bus waveguide. The sensors achieve an optical finesse of 1320 and intrinsic sensitivity of 78 fm kPa −1 , leading to a noise-equivalent pressure below 55 $${{{\rm{mPa}}}}/\sqrt{{{{\rm{Hz}}}}}$$ , calibrated from 3.36 MHz to 30 MHz. High-resolution imaging of fine structures validates real-world applicability. a-SiC is also easily integrated on most substrates due to its low deposition temperature. Our results position a-SiC as a promising solution for optical ultrasound sensing, combining miniaturization, low-loss, and high-sensitivity.- 18 December 2025
- Published by Springer Nature in Communications Physics
- Vol. 9 (1)
Open AccessAmorphous silicon-carbide photonics for ultrasound imaging
Photonic ultrasound sensors promise unparalleled spatial and temporal resolution in ultrasound imaging due to their size-independent noise figure, high sensitivity, and broad bandwidth. Optical materials can further improve performance and stability, but achieving small size, high sensitivity, and wide bandwidth remains challenging. This work introduces amorphous silicon carbide (a-SiC) for ultrasound sensing, offering strong optical confinement, low propagation loss, and high stability for miniaturized microring sensors. We demonstrate a compact detection system with a 20-transducers linear array coupled to a single bus waveguide. The sensors achieve an optical finesse of 1320 and intrinsic sensitivity of 78 fm kPa −1 , leading to a noise-equivalent pressure below 55 $${{{\rm{mPa}}}}/\sqrt{{{{\rm{Hz}}}}}$$ , calibrated from 3.36 MHz to 30 MHz. High-resolution imaging of fine structures validates real-world applicability. a-SiC is also easily integrated on most substrates due to its low deposition temperature. Our results position a-SiC as a promising solution for optical ultrasound sensing, combining miniaturization, low-loss, and high-sensitivity. - Open Access
- 1 October 2025
- Published by AIP Publishing in APL Photonics
- Vol. 10 (10)
Heterogeneous integration of silicon nitride and amorphous silicon carbide photonics
Amorphous silicon carbide (a-SiC) has emerged as a compelling candidate for applications in integrated photonics, known for its high refractive index, high optical quality, high thermo-optic coefficient, and strong third-order nonlinearities. Furthermore, a-SiC can be easily deposited via CMOS-compatible chemical vapor deposition (CVD) techniques, allowing for precise thickness control and adjustable material properties on arbitrary substrates. Silicon nitride (SiN) is an industrially well-established and well-matured platform, which exhibits ultra-low propagation loss, but it is suboptimal for high-density reconfigurable photonics due to the large minimum bending radius and constrained tunability. In this work, we monolithically combine the a-SiC with SiN photonics, leveraging the merits of both platforms, and achieve the a-SiC/SiN heterogeneous integration with an on-chip interconnection loss of (0.28+0.44−0.28) dB and integration density increment exceeding 4444-fold. By implementing active devices on the a-SiC, we achieve 27 times higher thermo-optic tuning efficiency, with respect to the SiN photonic platform. In addition, the a-SiC/SiN platform gives the flexibility to choose the optimal fiber-to-chip coupling strategy depending on the interfacing platform, with efficient side-coupling on SiN and grating-coupling on the a-SiC platform. The proposed a-SiC/SiN photonic platform can foster versatile applications in programmable and quantum photonics, nonlinear optics, and beyond.
- 1 October 2025
- Published by AIP Publishing in APL Photonics
- Vol. 10 (10)
Open AccessHeterogeneous integration of silicon nitride and amorphous silicon carbide photonics
Amorphous silicon carbide (a-SiC) has emerged as a compelling candidate for applications in integrated photonics, known for its high refractive index, high optical quality, high thermo-optic coefficient, and strong third-order nonlinearities. Furthermore, a-SiC can be easily deposited via CMOS-compatible chemical vapor deposition (CVD) techniques, allowing for precise thickness control and adjustable material properties on arbitrary substrates. Silicon nitride (SiN) is an industrially well-established and well-matured platform, which exhibits ultra-low propagation loss, but it is suboptimal for high-density reconfigurable photonics due to the large minimum bending radius and constrained tunability. In this work, we monolithically combine the a-SiC with SiN photonics, leveraging the merits of both platforms, and achieve the a-SiC/SiN heterogeneous integration with an on-chip interconnection loss of (0.28+0.44−0.28) dB and integration density increment exceeding 4444-fold. By implementing active devices on the a-SiC, we achieve 27 times higher thermo-optic tuning efficiency, with respect to the SiN photonic platform. In addition, the a-SiC/SiN platform gives the flexibility to choose the optimal fiber-to-chip coupling strategy depending on the interfacing platform, with efficient side-coupling on SiN and grating-coupling on the a-SiC platform. The proposed a-SiC/SiN photonic platform can foster versatile applications in programmable and quantum photonics, nonlinear optics, and beyond.
- Open Access
European Partnership in Metrology Project: Photonic and Quantum Sensors for Practical Integrated Primary Thermometry (PhoQuS-T)
Current temperature sensors require regular recalibration to maintain reliable temperature measurement. Photonic/quantum-based approaches have the potential to radically change the practice of thermometry through provision of in situ traceability, potentially through practical primary thermometry, without the need for sensor recalibration. This article gives an overview of the European Partnership in Metrology (EPM) project: Photonic and quantum sensors for practical integrated primary thermometry (PhoQuS-T), which aims to develop sensors based on photonic ring resonators and optomechanical resonators for robust, small-scale, integrated, and wide-range temperature measurement. The different phases of the project will be presented. The development of the integrated optical practical primary thermometer operating from 4 K to 500 K will be reached by a combination of different sensing techniques: with the optomechanical sensor, quantum thermometry below 10 K will provide a quantum reference for the optical noise thermometry (operating in the range 4 K to 300 K), whilst using the high-resolution photonic (ring resonator) sensor the temperature range to be extended from 80 K to 500 K. The important issues of robust fibre-to-chip coupling will be addressed, and application case studies of the developed sensors in ion-trap monitoring and quantum-based pressure standards will be discussed.
Open AccessEuropean Partnership in Metrology Project: Photonic and Quantum Sensors for Practical Integrated Primary Thermometry (PhoQuS-T)
Current temperature sensors require regular recalibration to maintain reliable temperature measurement. Photonic/quantum-based approaches have the potential to radically change the practice of thermometry through provision of in situ traceability, potentially through practical primary thermometry, without the need for sensor recalibration. This article gives an overview of the European Partnership in Metrology (EPM) project: Photonic and quantum sensors for practical integrated primary thermometry (PhoQuS-T), which aims to develop sensors based on photonic ring resonators and optomechanical resonators for robust, small-scale, integrated, and wide-range temperature measurement. The different phases of the project will be presented. The development of the integrated optical practical primary thermometer operating from 4 K to 500 K will be reached by a combination of different sensing techniques: with the optomechanical sensor, quantum thermometry below 10 K will provide a quantum reference for the optical noise thermometry (operating in the range 4 K to 300 K), whilst using the high-resolution photonic (ring resonator) sensor the temperature range to be extended from 80 K to 500 K. The important issues of robust fibre-to-chip coupling will be addressed, and application case studies of the developed sensors in ion-trap monitoring and quantum-based pressure standards will be discussed.
- Open Access
Amorphous Silicon-Carbide Photonics for Ultrasound Imaging
Photonic ultrasound sensors offer unparalleled potential for improving spatial and temporal resolution in ultrasound imaging applications due to their size-independent noise figure, high sensitivity, and broad bandwidth characteristics. The exploration of optical materials in ultrasound sensing has attracted significant interest due to their potential to further enhance device performance, fabrication compatibility, and long-term stability. This work introduces amorphous silicon carbide (a-SiC) as a material for optical ultrasound sensing. a-SiC offers a balanced combination of optical confinement, low propagation loss, and high material stability, enabling sensitive and miniaturized microring sensors. We demonstrate a compact ultrasound detection system with a linear array of 20 transducers coupled to a single bus waveguide. The sensors feature a maximum optical finesse of 1320 and an intrinsic platform sensitivity of 78 fm/kPa, leading to a noise equivalent pressure density below 55 $\mathrm{mPa}/\sqrt{\mathrm{Hz}}$, which is calibrated to a hydrophone from 3.36 MHz to 30 MHz. Additionally, we perform high-resolution ultrasound imaging of fine structures, highlighting the viability of these sensors in real-world applications. Moreover, its low deposition temperature allows a-SiC material for optical ultrasound sensors to be integrated on most substrates. These results position a-SiC as a promising material for optical ultrasound sensing, offering a miniaturized, low-loss, and high-sensitivity solution for next-generation photoacoustic imaging applications.Open AccessAmorphous Silicon-Carbide Photonics for Ultrasound Imaging
Photonic ultrasound sensors offer unparalleled potential for improving spatial and temporal resolution in ultrasound imaging applications due to their size-independent noise figure, high sensitivity, and broad bandwidth characteristics. The exploration of optical materials in ultrasound sensing has attracted significant interest due to their potential to further enhance device performance, fabrication compatibility, and long-term stability. This work introduces amorphous silicon carbide (a-SiC) as a material for optical ultrasound sensing. a-SiC offers a balanced combination of optical confinement, low propagation loss, and high material stability, enabling sensitive and miniaturized microring sensors. We demonstrate a compact ultrasound detection system with a linear array of 20 transducers coupled to a single bus waveguide. The sensors feature a maximum optical finesse of 1320 and an intrinsic platform sensitivity of 78 fm/kPa, leading to a noise equivalent pressure density below 55 $\mathrm{mPa}/\sqrt{\mathrm{Hz}}$, which is calibrated to a hydrophone from 3.36 MHz to 30 MHz. Additionally, we perform high-resolution ultrasound imaging of fine structures, highlighting the viability of these sensors in real-world applications. Moreover, its low deposition temperature allows a-SiC material for optical ultrasound sensors to be integrated on most substrates. These results position a-SiC as a promising material for optical ultrasound sensing, offering a miniaturized, low-loss, and high-sensitivity solution for next-generation photoacoustic imaging applications. - 24 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 43 (3) , 1419-1428
Optimizing Cladding Elasticity to Enhance Sensitivity in Silicon Photonic Ultrasound Sensors
Ultrasound is widely used in medical imaging, and emerging photo-acoustic imaging is crucial for disease diagnosis. Currently, high-end photo-acoustic imaging systems rely on piezo-electric materials for detecting ultrasound waves, which come with sensitivity, noise, and bandwidth limitations. Advanced applications demand a large matrix of broadband, high-resolution, and scalable ultrasound sensors. Silicon photonic circuits have been introduced to meet these requirements by detecting ultrasound-induced deformation and stress in silicon waveguides. Although higher sensitivities could facilitate the exploration of new applications, the high stiffness of the waveguide materials constrains the intrinsic sensitivity of the silicon photonic circuits to ultrasound signals. Here, we explore the impact of the mechanical properties of a polymer cladding on the sensitivity of silicon photonic ultrasound sensors. Our model and experiments reveal that optimizing the polymer cladding's stiffness enhances the resonance wavelength sensitivity. Experimentally, we show a fourfold increase in the sensitivity compared to the sensors without a cladding polymer and, a twofold sensitivity increase compared to the sensors with a cladding polymer of saturated cross-linking density. Interestingly, comparing experiments with the optomechanical model suggests that the change in Young's Modulus alone cannot explain the sensitivity increase. In conclusion, polymer-coated silicon photonic ultrasound sensors exhibit potential for advanced photo-acoustic imaging applications. It offers the prospect of increasing the ultrasound detection sensitivity of silicon photonic ultrasound sensors while using CMOS-compatible processes. This paves the way to integrate the polymer-coated silicon photonic ultrasound sensors with electronics to utilize the sensors in advanced medical imaging applications.
- 24 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 43 (3) , 1419-1428
Optimizing Cladding Elasticity to Enhance Sensitivity in Silicon Photonic Ultrasound Sensors
Ultrasound is widely used in medical imaging, and emerging photo-acoustic imaging is crucial for disease diagnosis. Currently, high-end photo-acoustic imaging systems rely on piezo-electric materials for detecting ultrasound waves, which come with sensitivity, noise, and bandwidth limitations. Advanced applications demand a large matrix of broadband, high-resolution, and scalable ultrasound sensors. Silicon photonic circuits have been introduced to meet these requirements by detecting ultrasound-induced deformation and stress in silicon waveguides. Although higher sensitivities could facilitate the exploration of new applications, the high stiffness of the waveguide materials constrains the intrinsic sensitivity of the silicon photonic circuits to ultrasound signals. Here, we explore the impact of the mechanical properties of a polymer cladding on the sensitivity of silicon photonic ultrasound sensors. Our model and experiments reveal that optimizing the polymer cladding's stiffness enhances the resonance wavelength sensitivity. Experimentally, we show a fourfold increase in the sensitivity compared to the sensors without a cladding polymer and, a twofold sensitivity increase compared to the sensors with a cladding polymer of saturated cross-linking density. Interestingly, comparing experiments with the optomechanical model suggests that the change in Young's Modulus alone cannot explain the sensitivity increase. In conclusion, polymer-coated silicon photonic ultrasound sensors exhibit potential for advanced photo-acoustic imaging applications. It offers the prospect of increasing the ultrasound detection sensitivity of silicon photonic ultrasound sensors while using CMOS-compatible processes. This paves the way to integrate the polymer-coated silicon photonic ultrasound sensors with electronics to utilize the sensors in advanced medical imaging applications.
- 24 October 2023
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 20 (4) , 044061
Multimode Brownian dynamics of a nanomechanical resonator in a viscous fluid
Brownian motion imposes a hard limit on the overall precision of a nanomechanical measurement. Here, we present a combined experimental and theoretical study of the Brownian dynamics of a quintessential nanomechanical system, a doubly clamped nanomechanical beam resonator, in a viscous fluid. Our theoretical approach is based on the fluctuation-dissipation theorem of statistical mechanics: we determine the dissipation from fluid dynamics; we incorporate this dissipation into the proper elastic equation to obtain the equation of motion; and the fluctuation-dissipation theorem then directly provides an analytical expression for the position-dependent power spectral density (PSD) of the displacement fluctuations of the beam. We compare our theory to experiments on nanomechanical beams immersed in air and water and obtain excellent agreement. Within our experimental parameter range, the Brownian-force noise driving the nanomechanical beam has a colored PSD due to the “memory” of the fluid; the force noise remains mode independent and uncorrelated in space. These conclusions are not only of interest for nanomechanical sensing but also provide insight into the fluctuations of elastic systems at any length scale.
- 24 October 2023
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 20 (4) , 044061
Multimode Brownian dynamics of a nanomechanical resonator in a viscous fluid
Brownian motion imposes a hard limit on the overall precision of a nanomechanical measurement. Here, we present a combined experimental and theoretical study of the Brownian dynamics of a quintessential nanomechanical system, a doubly clamped nanomechanical beam resonator, in a viscous fluid. Our theoretical approach is based on the fluctuation-dissipation theorem of statistical mechanics: we determine the dissipation from fluid dynamics; we incorporate this dissipation into the proper elastic equation to obtain the equation of motion; and the fluctuation-dissipation theorem then directly provides an analytical expression for the position-dependent power spectral density (PSD) of the displacement fluctuations of the beam. We compare our theory to experiments on nanomechanical beams immersed in air and water and obtain excellent agreement. Within our experimental parameter range, the Brownian-force noise driving the nanomechanical beam has a colored PSD due to the “memory” of the fluid; the force noise remains mode independent and uncorrelated in space. These conclusions are not only of interest for nanomechanical sensing but also provide insight into the fluctuations of elastic systems at any length scale.
- 1 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (7) , 6517-6529
High-Resolution Dielectric Characterization of Single Cells and Microparticles Using Integrated Microfluidic Microwave Sensors
Microwave sensors can probe intrinsic material properties of analytes in a microfluidic channel at physiologically relevant ion concentrations. While microwave sensors have been used to detect single cells and microparticles in earlier studies, the synergistic use and comparative analysis of microwave sensors with optical microscopy for material classification and size tracking applications have been scarcely investigated so far. Here we combined microwave and optical sensing to differentiate microscale objects based on their dielectric properties. We designed and fabricated two types of planar sensor: a Coplanar Waveguide Resonator (CPW) and a Split-Ring Resonator (SRR). Both sensors possessed sensing electrodes with a narrow gap to detect single cells passing through a microfluidic channel integrated on the same chip. We also show that standalone microwave sensors can track the relative changes in cellular size in real-time. In sensing single 20-micron diameter polystyrene particles, Signal-to-Noise ratio values of approximately 100 for CPW and 70 for SRR sensors were obtained. These findings demonstrate that microwave sensing technology can serve as a complementary technique for single-cell biophysical experiments and microscale pollutant screening.
- 1 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (7) , 6517-6529
High-Resolution Dielectric Characterization of Single Cells and Microparticles Using Integrated Microfluidic Microwave Sensors
Microwave sensors can probe intrinsic material properties of analytes in a microfluidic channel at physiologically relevant ion concentrations. While microwave sensors have been used to detect single cells and microparticles in earlier studies, the synergistic use and comparative analysis of microwave sensors with optical microscopy for material classification and size tracking applications have been scarcely investigated so far. Here we combined microwave and optical sensing to differentiate microscale objects based on their dielectric properties. We designed and fabricated two types of planar sensor: a Coplanar Waveguide Resonator (CPW) and a Split-Ring Resonator (SRR). Both sensors possessed sensing electrodes with a narrow gap to detect single cells passing through a microfluidic channel integrated on the same chip. We also show that standalone microwave sensors can track the relative changes in cellular size in real-time. In sensing single 20-micron diameter polystyrene particles, Signal-to-Noise ratio values of approximately 100 for CPW and 70 for SRR sensors were obtained. These findings demonstrate that microwave sensing technology can serve as a complementary technique for single-cell biophysical experiments and microscale pollutant screening.
- 4 January 2022
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 16 (3) , 3821-3833
Atmospheric Pressure Mass Spectrometry of Single Viruses and Nanoparticles by Nanoelectromechanical Systems
Mass spectrometry of intact nanoparticles and viruses can serve as a potent characterization tool for material science and biophysics. Inaccessible by widespread commercial techniques, the mass of single nanoparticles and viruses (>10MDa) can be readily measured by nanoelectromechanical systems (NEMS)-based mass spectrometry, where charged and isolated analyte particles are generated by electrospray ionization (ESI) in air and transported onto the NEMS resonator for capture and detection. However, the applicability of NEMS as a practical solution is hindered by their miniscule surface area, which results in poor limit-of-detection and low capture efficiency values. Another hindrance is the necessity to house the NEMS inside complex vacuum systems, which is required in part to focus analytes toward the miniscule detection surface of the NEMS. Here, we overcome both limitations by integrating an ion lens onto the NEMS chip. The ion lens is composed of a polymer layer, which charges up by receiving part of the ions incoming from the ESI tip and consequently starts to focus the analytes toward an open window aligned with the active area of the NEMS electrostatically. With this integrated system, we have detected the mass of gold and polystyrene nanoparticles under ambient conditions and with two orders-of-magnitude improvement in capture efficiency compared to the state-of-the-art. We then applied this technology to obtain the mass spectrum of SARS-CoV-2 and BoHV-1 virions. With the increase in analytical throughput, the simplicity of the overall setup, and the operation capability under ambient conditions, the technique demonstrates that NEMS mass spectrometry can be deployed for mass detection of engineered nanoparticles and biological samples efficiently.
- 4 January 2022
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 16 (3) , 3821-3833
Atmospheric Pressure Mass Spectrometry of Single Viruses and Nanoparticles by Nanoelectromechanical Systems
Mass spectrometry of intact nanoparticles and viruses can serve as a potent characterization tool for material science and biophysics. Inaccessible by widespread commercial techniques, the mass of single nanoparticles and viruses (>10MDa) can be readily measured by nanoelectromechanical systems (NEMS)-based mass spectrometry, where charged and isolated analyte particles are generated by electrospray ionization (ESI) in air and transported onto the NEMS resonator for capture and detection. However, the applicability of NEMS as a practical solution is hindered by their miniscule surface area, which results in poor limit-of-detection and low capture efficiency values. Another hindrance is the necessity to house the NEMS inside complex vacuum systems, which is required in part to focus analytes toward the miniscule detection surface of the NEMS. Here, we overcome both limitations by integrating an ion lens onto the NEMS chip. The ion lens is composed of a polymer layer, which charges up by receiving part of the ions incoming from the ESI tip and consequently starts to focus the analytes toward an open window aligned with the active area of the NEMS electrostatically. With this integrated system, we have detected the mass of gold and polystyrene nanoparticles under ambient conditions and with two orders-of-magnitude improvement in capture efficiency compared to the state-of-the-art. We then applied this technology to obtain the mass spectrum of SARS-CoV-2 and BoHV-1 virions. With the increase in analytical throughput, the simplicity of the overall setup, and the operation capability under ambient conditions, the technique demonstrates that NEMS mass spectrometry can be deployed for mass detection of engineered nanoparticles and biological samples efficiently.