Ahmet Murat Yağci
Ahmet Murat Yağci has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Cenk Yanik
SUNUM, Nanotechnology Research and Application Center, Sabanci University 4 , Istanbul 34956, Turkey
2 shared publications - Mehmet Selim Hanay
Bilkent University
2 shared publications - Selim Acar
Department of Physics, Faculty of Science
2 shared publications Ali Ilker Isik
Aselsan Inc., Ankara, Trkiye
1 shared publication- Atakan B. Ari
Department of Mechanical Engineering, Division of Materials Science and Engineering, and the Photonics Center, Boston University, Boston, Massachusetts 02215, United States
1 shared publication - Aykut Ozkul
Department of Virology, Faculty of Veterinary Medicine, Ankara University, Ankara, Turkey
1 shared publication
Latest Publications
- 31 March 2026
- Published by Gazi University in Gazi University Journal of Science Part A: Engineering and Innovation
- Vol. 13 (1) , 391-403
Improved Bond Strength in Au Wire Bonding Through Process Parameter Optimization and Argon Plasma Cleaning
This article reports on the optimization of Au wire bonding for GaAs chips. The effects of bonding parameters on ball size were evaluated by measuring both the average diameter and its standard deviation. Using the parameter set with the smallest deviation, argon plasma cleaning was applied to the pads while maintaining the unchanged bonding conditions. Although the average pull strength remained nearly constant, the standard deviation decreased from 1.1 to 0.61, indicating an improvement in process consistency. These results demonstrate that plasma-assisted surface treatment provides a more consistent and reliable wire bonding process in GaAs packaging applications.
- 31 March 2026
- Published by Gazi University in Gazi University Journal of Science Part A: Engineering and Innovation
- Vol. 13 (1) , 391-403
Improved Bond Strength in Au Wire Bonding Through Process Parameter Optimization and Argon Plasma Cleaning
This article reports on the optimization of Au wire bonding for GaAs chips. The effects of bonding parameters on ball size were evaluated by measuring both the average diameter and its standard deviation. Using the parameter set with the smallest deviation, argon plasma cleaning was applied to the pads while maintaining the unchanged bonding conditions. Although the average pull strength remained nearly constant, the standard deviation decreased from 1.1 to 0.61, indicating an improvement in process consistency. These results demonstrate that plasma-assisted surface treatment provides a more consistent and reliable wire bonding process in GaAs packaging applications.
- 30 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave and Wireless Technology Letters
- Vol. PP (2771957X) , 1-4
Filled-Waveguide-Based Extraction and Package-Level Validation of Underfill Loss Tangent for mm-Wave Flip-Chip Applications
Accurate characterization of underfill dielectric properties is critical for millimeter-wave (mm-wave) flip-chip packaging, as dielectric loss can significantly degrade high-frequency performance. In this letter, the frequency-dependent electrical permittivity and loss tangent of an epoxy-based underfill are extracted via transmission/reflection method using a WR-28 filled waveguide. Then, the extracted material properties are directly incorporated into a full-wave FEM model of a flip-chip packaged transmission structure without any fitting or tuning parameters and confirmed with measurements. To validate the approach at the package level, custom-designed flip-chip packaged substrate and dedicated thru–reflect–line (TRL) calibration kits are fabricated, enabling accurate S-parameter measurements from 10 to 40 GHz. Excellent agreement between simulated and measured results, both with and without underfill, confirms the accuracy of the proposed characterization method and highlights the dominant impact of underfill dielectric loss on mm-wave package performance.
- 30 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave and Wireless Technology Letters
- Vol. PP (2771957X) , 1-4
Filled-Waveguide-Based Extraction and Package-Level Validation of Underfill Loss Tangent for mm-Wave Flip-Chip Applications
Accurate characterization of underfill dielectric properties is critical for millimeter-wave (mm-wave) flip-chip packaging, as dielectric loss can significantly degrade high-frequency performance. In this letter, the frequency-dependent electrical permittivity and loss tangent of an epoxy-based underfill are extracted via transmission/reflection method using a WR-28 filled waveguide. Then, the extracted material properties are directly incorporated into a full-wave FEM model of a flip-chip packaged transmission structure without any fitting or tuning parameters and confirmed with measurements. To validate the approach at the package level, custom-designed flip-chip packaged substrate and dedicated thru–reflect–line (TRL) calibration kits are fabricated, enabling accurate S-parameter measurements from 10 to 40 GHz. Excellent agreement between simulated and measured results, both with and without underfill, confirms the accuracy of the proposed characterization method and highlights the dominant impact of underfill dielectric loss on mm-wave package performance.
- 4 January 2022
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 16 (3) , 3821-3833
Atmospheric Pressure Mass Spectrometry of Single Viruses and Nanoparticles by Nanoelectromechanical Systems
Mass spectrometry of intact nanoparticles and viruses can serve as a potent characterization tool for material science and biophysics. Inaccessible by widespread commercial techniques, the mass of single nanoparticles and viruses (>10MDa) can be readily measured by nanoelectromechanical systems (NEMS)-based mass spectrometry, where charged and isolated analyte particles are generated by electrospray ionization (ESI) in air and transported onto the NEMS resonator for capture and detection. However, the applicability of NEMS as a practical solution is hindered by their miniscule surface area, which results in poor limit-of-detection and low capture efficiency values. Another hindrance is the necessity to house the NEMS inside complex vacuum systems, which is required in part to focus analytes toward the miniscule detection surface of the NEMS. Here, we overcome both limitations by integrating an ion lens onto the NEMS chip. The ion lens is composed of a polymer layer, which charges up by receiving part of the ions incoming from the ESI tip and consequently starts to focus the analytes toward an open window aligned with the active area of the NEMS electrostatically. With this integrated system, we have detected the mass of gold and polystyrene nanoparticles under ambient conditions and with two orders-of-magnitude improvement in capture efficiency compared to the state-of-the-art. We then applied this technology to obtain the mass spectrum of SARS-CoV-2 and BoHV-1 virions. With the increase in analytical throughput, the simplicity of the overall setup, and the operation capability under ambient conditions, the technique demonstrates that NEMS mass spectrometry can be deployed for mass detection of engineered nanoparticles and biological samples efficiently.
- 4 January 2022
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 16 (3) , 3821-3833
Atmospheric Pressure Mass Spectrometry of Single Viruses and Nanoparticles by Nanoelectromechanical Systems
Mass spectrometry of intact nanoparticles and viruses can serve as a potent characterization tool for material science and biophysics. Inaccessible by widespread commercial techniques, the mass of single nanoparticles and viruses (>10MDa) can be readily measured by nanoelectromechanical systems (NEMS)-based mass spectrometry, where charged and isolated analyte particles are generated by electrospray ionization (ESI) in air and transported onto the NEMS resonator for capture and detection. However, the applicability of NEMS as a practical solution is hindered by their miniscule surface area, which results in poor limit-of-detection and low capture efficiency values. Another hindrance is the necessity to house the NEMS inside complex vacuum systems, which is required in part to focus analytes toward the miniscule detection surface of the NEMS. Here, we overcome both limitations by integrating an ion lens onto the NEMS chip. The ion lens is composed of a polymer layer, which charges up by receiving part of the ions incoming from the ESI tip and consequently starts to focus the analytes toward an open window aligned with the active area of the NEMS electrostatically. With this integrated system, we have detected the mass of gold and polystyrene nanoparticles under ambient conditions and with two orders-of-magnitude improvement in capture efficiency compared to the state-of-the-art. We then applied this technology to obtain the mass spectrum of SARS-CoV-2 and BoHV-1 virions. With the increase in analytical throughput, the simplicity of the overall setup, and the operation capability under ambient conditions, the technique demonstrates that NEMS mass spectrometry can be deployed for mass detection of engineered nanoparticles and biological samples efficiently.
- 31 December 2021
- Published by Elsevier in Thin Solid Films
- Vol. 744, 139078
The evolution of nanoscale pores with post-annealing and the structure-electrical property correlation in vanadium oxide thin films
- 31 December 2021
- Published by Elsevier in Thin Solid Films
- Vol. 744, 139078
The evolution of nanoscale pores with post-annealing and the structure-electrical property correlation in vanadium oxide thin films
- Open Access
- 10 June 2020
- Published by Frontiers Media SA in Frontiers in Mechanical Engineering
- Vol. 6
Performance of Nano-Electromechanical Systems as Nanoparticle Position Sensors
Nanoelectromechanical systems (NEMS) have been utilized as sensitive mass sensors in many applications such as single cell characterization, volatile organic biomarker detection and single molecule mass spectrometry. Using the frequency shift detection, mass of single analytes can be resolved. Mass detection sensitivity can be further improved by accurate measurement of the position, unlocking extra capabilities in nanoscale positioning and manipulation applications. Here, we studied the position sensing performance of two-mode NEMS resonators during detection of single 20 nm gold nanoparticles (GNPs). By recording the position of each particle with frequency shift sensing, the position detection accuracy was evaluated for different beam models and the results are validated by SEM imaging our results indicate that the position sensing accuracy, and therefore the mass sensing accuracy, of nanomechanical resonators depends critically on the use of appropriate beam models.
- 10 June 2020
- Published by Frontiers Media SA in Frontiers in Mechanical Engineering
- Vol. 6
Open AccessPerformance of Nano-Electromechanical Systems as Nanoparticle Position Sensors
Nanoelectromechanical systems (NEMS) have been utilized as sensitive mass sensors in many applications such as single cell characterization, volatile organic biomarker detection and single molecule mass spectrometry. Using the frequency shift detection, mass of single analytes can be resolved. Mass detection sensitivity can be further improved by accurate measurement of the position, unlocking extra capabilities in nanoscale positioning and manipulation applications. Here, we studied the position sensing performance of two-mode NEMS resonators during detection of single 20 nm gold nanoparticles (GNPs). By recording the position of each particle with frequency shift sensing, the position detection accuracy was evaluated for different beam models and the results are validated by SEM imaging our results indicate that the position sensing accuracy, and therefore the mass sensing accuracy, of nanomechanical resonators depends critically on the use of appropriate beam models.