Yaxin Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yaxin Guo has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
Chaohui He
School of Nuclear Science and technology, Xian Jiaotong University, Xian, China
7 shared publications- Yang Li
School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an 710049, China
6 shared publications - Pei Li
School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an 710049, China
5 shared publications Ruibin Li
National Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xian, China
5 shared publicationsJiaxin Liu
School of Nuclear Science and technology, Xian Jiaotong University, Xian, China
4 shared publications- Wei Chen
National Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xian, China
4 shared publications
Latest Publications
- 25 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (6) , 1927-1937
Pulsed-Laser Testing to Evaluate Transient Dose Rate Effect on a Commercial-Off-the-Shelf FPGA
To overcome the complexity and challenges of transient γ irradiation experiments, this paper adopted pulsed lasers to simulate the transient dose rate effect (TDRE) on a commercial off-the-shelf (COTS) field-programmable gate array (FPGA), taking advantage of good stability, low interference, high efficiency, and low cost. Three test programs were designed for the Virtex-5 XC5VSX95T FPGA, including one program used in previous transient γ irradiation experiments. Laser experiments involved a wide energy range, and recorded failure features of the device under test (DUT) and photocurrents on the power supplies. By comparing the results with transient γ irradiation experiments, it was demonstrated that pulsed lasers can be used to effectively simulate FPGA’s TDRE, showing consistent effect characteristics. Additionally, the sensitivity of the internal clock and logic resources of the FPGA was analyzed, finding that delaylocked loops (DLLs) have a high sensitivity and that disturbances in the logic resources could propagate. There are multiple factors affecting the internal sensitivities. Furthermore, like transient γ rays, high-intensity pulsed lasers would also induce dynamic reconfiguration of the FPGA, which was analyzed specifically. These research findings are important supplements to studying FPGA’s TDRE, and also demonstrate a significant prospect of using pulsed lasers to simulate the TDRE in very large-scale integrated (VLSI) circuits.
- 25 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (6) , 1927-1937
Pulsed-Laser Testing to Evaluate Transient Dose Rate Effect on a Commercial-Off-the-Shelf FPGA
To overcome the complexity and challenges of transient γ irradiation experiments, this paper adopted pulsed lasers to simulate the transient dose rate effect (TDRE) on a commercial off-the-shelf (COTS) field-programmable gate array (FPGA), taking advantage of good stability, low interference, high efficiency, and low cost. Three test programs were designed for the Virtex-5 XC5VSX95T FPGA, including one program used in previous transient γ irradiation experiments. Laser experiments involved a wide energy range, and recorded failure features of the device under test (DUT) and photocurrents on the power supplies. By comparing the results with transient γ irradiation experiments, it was demonstrated that pulsed lasers can be used to effectively simulate FPGA’s TDRE, showing consistent effect characteristics. Additionally, the sensitivity of the internal clock and logic resources of the FPGA was analyzed, finding that delaylocked loops (DLLs) have a high sensitivity and that disturbances in the logic resources could propagate. There are multiple factors affecting the internal sensitivities. Furthermore, like transient γ rays, high-intensity pulsed lasers would also induce dynamic reconfiguration of the FPGA, which was analyzed specifically. These research findings are important supplements to studying FPGA’s TDRE, and also demonstrate a significant prospect of using pulsed lasers to simulate the TDRE in very large-scale integrated (VLSI) circuits.
- Open Access
- 1 January 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (1)
Investigation of proton single-event transient in CMOS image sensor
With the increasingly widespread application of CMOS image sensors (CIS) in radiation environments, such as aerospace, their radiation effects have gained attention. This paper investigates single-event transient (SET) caused by the proton direct ionization on CIS, combining both experimental and simulation methods. The proton beam energy used in the experiment is 12 MeV, with a flux up to 3.5 × 108 p/(cm2 s). Due to the periodicity of the proton beam, the CIS output displays a phenomenon of alternating brightness and darkness. When the proton beam flux is low, numerous SET bright spots with different outputs are observed. To comprehensively analyze these experimental phenomena, a typical three-dimensional 4T pinned photodiode model is constructed in TCAD, and relevant SET simulation is carried out. The results indicate that incident position, incident time, and the number of incident protons significantly affect the output of SET-generated bright spots, which are key factors contributing to the different bright spots observed in the experiment.
- 1 January 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (1)
Open AccessInvestigation of proton single-event transient in CMOS image sensor
With the increasingly widespread application of CMOS image sensors (CIS) in radiation environments, such as aerospace, their radiation effects have gained attention. This paper investigates single-event transient (SET) caused by the proton direct ionization on CIS, combining both experimental and simulation methods. The proton beam energy used in the experiment is 12 MeV, with a flux up to 3.5 × 108 p/(cm2 s). Due to the periodicity of the proton beam, the CIS output displays a phenomenon of alternating brightness and darkness. When the proton beam flux is low, numerous SET bright spots with different outputs are observed. To comprehensively analyze these experimental phenomena, a typical three-dimensional 4T pinned photodiode model is constructed in TCAD, and relevant SET simulation is carried out. The results indicate that incident position, incident time, and the number of incident protons significantly affect the output of SET-generated bright spots, which are key factors contributing to the different bright spots observed in the experiment.
- Open Access
- 1 December 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (12)
Transient dose rate effects in silicon–germanium heterojunction bipolar transistors
Transient γ-radiation and laser-simulated experiments were carried out to investigate the transient dose rate effect (TDRE) in SiGe heterojunction bipolar transistors (HBTs) for the first time. The results indicate that IBM43RF0100 SiGe HBTs experience a significant sensitivity of TDRE. For the laser-simulated experiment, the duration of transient current and charge collection are matched well with that of transient γ-radiation. The amplitude of transient photocurrent induced by the lower energy order of μJ approaches the transient photocurrent induced by transient γ-radiation. It is demonstrated that laser-simulated experiments are a candidate and a convenient method to evaluate the TDRE response of SiGe HBTs, which avoids serious electromagnetic interference in the transient γ-radiation environment.
- 1 December 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (12)
Open AccessTransient dose rate effects in silicon–germanium heterojunction bipolar transistors
Transient γ-radiation and laser-simulated experiments were carried out to investigate the transient dose rate effect (TDRE) in SiGe heterojunction bipolar transistors (HBTs) for the first time. The results indicate that IBM43RF0100 SiGe HBTs experience a significant sensitivity of TDRE. For the laser-simulated experiment, the duration of transient current and charge collection are matched well with that of transient γ-radiation. The amplitude of transient photocurrent induced by the lower energy order of μJ approaches the transient photocurrent induced by transient γ-radiation. It is demonstrated that laser-simulated experiments are a candidate and a convenient method to evaluate the TDRE response of SiGe HBTs, which avoids serious electromagnetic interference in the transient γ-radiation environment.
- 13 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (8) , 2106-2115
Transient Dose Rate Effect Between System-in-Package and Printed Circuit Boards: A Comparative Experimental Study
This paper presents a comparative experimental study of the transient dose rate effect (TDRE) between the System-in-Package (SiP) SZ0501 and its prototype Printed Circuit Board (PCB). The SiP and prototype board have the same functions, and they can be regarded as complete electronic systems. The same program is applied to both electronic systems in transient gamma-ray experiments. Both the SiP and prototype board are supplied by external DC Power Analyzers. The operating currents and transient photocurrents are measured. Then, radiation performances of the SiP and prototype board are recorded with increasing dose rates. The experimental results show that the outputs of both systems have similar failure types, while there are significant discrepancies in terms of failure thresholds. In addition, both systems present latch-up effects, but their features are quite different. It is speculated that their power distribution networks (PDNs) are likely to be the main cause of these discrepancies. Experiments also show that using differential structure should be effective in improving the performance of the tested devices. These findings are analyzed and discussed by combining previous experimental results of this SiP.
- 13 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (8) , 2106-2115
Transient Dose Rate Effect Between System-in-Package and Printed Circuit Boards: A Comparative Experimental Study
This paper presents a comparative experimental study of the transient dose rate effect (TDRE) between the System-in-Package (SiP) SZ0501 and its prototype Printed Circuit Board (PCB). The SiP and prototype board have the same functions, and they can be regarded as complete electronic systems. The same program is applied to both electronic systems in transient gamma-ray experiments. Both the SiP and prototype board are supplied by external DC Power Analyzers. The operating currents and transient photocurrents are measured. Then, radiation performances of the SiP and prototype board are recorded with increasing dose rates. The experimental results show that the outputs of both systems have similar failure types, while there are significant discrepancies in terms of failure thresholds. In addition, both systems present latch-up effects, but their features are quite different. It is speculated that their power distribution networks (PDNs) are likely to be the main cause of these discrepancies. Experiments also show that using differential structure should be effective in improving the performance of the tested devices. These findings are analyzed and discussed by combining previous experimental results of this SiP.
- 23 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (7) , 1459-1469
Investigation of Transient Dose-Rate Effect on High-Speed Comparator SB9696
This paper investigates transient dose-rate effect (TDRE) on a high-speed comparator (SB9696), combining both experimental and simulation methods. Experimental results show that this comparator has two main kinds of transient responses under pulsed gamma-ray environment. First, when the total dose per pulse is less than 54.9 rad(Si), only a short disturbance appears and recovers within several microseconds. Second, when the total dose is beyond 399.6 rad(Si), the comparator is shortly interrupted and then recovers to an under-voltage operation state after several microseconds, and the under-voltage state has a long duration before recovering to a normal working state, which is an uncommon phenomenon that has not been found previously for comparators. A hypothesis is proposed that the short disturbance or interrupt is mainly caused by local photocurrents in the differential structure of the comparator, while the long under-voltage operation state is related to the global photocurrent with a long duration. Lastly, they are successfully verified by SPICE simulations. Simulation results indicate that the short disturbance or interrupt exactly result from local photocurrents in the differential pairs of the comparator’s output module. And, due to the rail-span collapse effect as the global photocurrent flows through power supply lines, the effective supply voltage of the comparator would decrease, thus resulting in a long under-voltage operation state.
- 23 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (7) , 1459-1469
Investigation of Transient Dose-Rate Effect on High-Speed Comparator SB9696
This paper investigates transient dose-rate effect (TDRE) on a high-speed comparator (SB9696), combining both experimental and simulation methods. Experimental results show that this comparator has two main kinds of transient responses under pulsed gamma-ray environment. First, when the total dose per pulse is less than 54.9 rad(Si), only a short disturbance appears and recovers within several microseconds. Second, when the total dose is beyond 399.6 rad(Si), the comparator is shortly interrupted and then recovers to an under-voltage operation state after several microseconds, and the under-voltage state has a long duration before recovering to a normal working state, which is an uncommon phenomenon that has not been found previously for comparators. A hypothesis is proposed that the short disturbance or interrupt is mainly caused by local photocurrents in the differential structure of the comparator, while the long under-voltage operation state is related to the global photocurrent with a long duration. Lastly, they are successfully verified by SPICE simulations. Simulation results indicate that the short disturbance or interrupt exactly result from local photocurrents in the differential pairs of the comparator’s output module. And, due to the rail-span collapse effect as the global photocurrent flows through power supply lines, the effective supply voltage of the comparator would decrease, thus resulting in a long under-voltage operation state.
- Open Access
- 1 April 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (4)
Feasibility and equivalence analysis of transient dose rate effect simulation by pulsed laser in level-shifting transceiver and TCAD simulation on its ESD circuits
Compared to linear accelerators, pulsed lasers have the characteristics of high efficiency, low cost, stable pulse output, and low environment interference for researching the transient dose rate effect (TDRE) on semiconductor devices. In this paper, pulsed laser radiation experiments are performed on a level-shifting transceiver. The experimental results are consistent with the results of the transient γ-ray radiation experiment, demonstrating the feasibility of using the pulsed laser in TDRE research on the level-shifting transceiver. This paper obtains theoretical and experimental conversion factors (CFs) through theoretical analysis and equivalency of the peak photocurrents, which are measured in pulsed laser and transient γ-ray radiation experiments. The CF results from the two approaches are within 7% of each other. In pulsed laser radiation experiments, an uncommon phenomenon is found. At the I/O (Input/Output) ports of the level-shifting transceiver, a trend of a positive photocurrent followed by a negative pulse is observed. A hypothesis is proposed that this photocurrent is produced by the turn-on and turn-off of the parasitic PNP (Positive-Negative-Positive) transistors in electrostatic discharge circuits at the level-shifting transceiver I/O ports. In addition, this hypothesis is verified by TCAD (Technology Computer Aided Design) simulations.
- 1 April 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (4)
Open AccessFeasibility and equivalence analysis of transient dose rate effect simulation by pulsed laser in level-shifting transceiver and TCAD simulation on its ESD circuits
Compared to linear accelerators, pulsed lasers have the characteristics of high efficiency, low cost, stable pulse output, and low environment interference for researching the transient dose rate effect (TDRE) on semiconductor devices. In this paper, pulsed laser radiation experiments are performed on a level-shifting transceiver. The experimental results are consistent with the results of the transient γ-ray radiation experiment, demonstrating the feasibility of using the pulsed laser in TDRE research on the level-shifting transceiver. This paper obtains theoretical and experimental conversion factors (CFs) through theoretical analysis and equivalency of the peak photocurrents, which are measured in pulsed laser and transient γ-ray radiation experiments. The CF results from the two approaches are within 7% of each other. In pulsed laser radiation experiments, an uncommon phenomenon is found. At the I/O (Input/Output) ports of the level-shifting transceiver, a trend of a positive photocurrent followed by a negative pulse is observed. A hypothesis is proposed that this photocurrent is produced by the turn-on and turn-off of the parasitic PNP (Positive-Negative-Positive) transistors in electrostatic discharge circuits at the level-shifting transceiver I/O ports. In addition, this hypothesis is verified by TCAD (Technology Computer Aided Design) simulations.
- 6 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (10) , 3279-3286
Key Factors of Laser-Induced Single-Event Transients on Different SiGe Process
Electronic equipment applied in the complex space environment may have combined damage under the independent conditions of temperatures, radiation effects and operating modes. The aim of this study is to evaluate the laser-induced single event transients (SETs) on dependence of the pre-irradiation elevated temperatures, accumulated total dose, bias conditions and laser energy for different SiGe processes. The experimental results show that the SETs response of SiGe HBTs are closely associated with the device structure and HBT designs. TCAD simulations are combined to demonstrate that KT9041 SiGe HBTs are more sensitive to SETs than IBM43RF0100.
- 6 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (10) , 3279-3286
Key Factors of Laser-Induced Single-Event Transients on Different SiGe Process
Electronic equipment applied in the complex space environment may have combined damage under the independent conditions of temperatures, radiation effects and operating modes. The aim of this study is to evaluate the laser-induced single event transients (SETs) on dependence of the pre-irradiation elevated temperatures, accumulated total dose, bias conditions and laser energy for different SiGe processes. The experimental results show that the SETs response of SiGe HBTs are closely associated with the device structure and HBT designs. TCAD simulations are combined to demonstrate that KT9041 SiGe HBTs are more sensitive to SETs than IBM43RF0100.
- 12 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (8) , 1840-1849
Experimental Study of Transient Dose Rate Effect on System-in-Package SZ0501
This article investigates the transient dose rate effect (TDRE) on the system-in-package (SiP) SZ0501 experimentally. A specialized program is designed for TDRE tests. With the increase of dose rates, the failure features of the SiP are recorded. Photocurrents on each power supply line are also measured to assist in analyzing SiP failures. In addition, both enabled and disabled programmable read-only memory (PROM) cases are considered to compare their discrepancies. The experimental results show that high frequency (HF) signals in the SiP are much sensitive to TDRE. Also, the logical resource in its field-programmable gate array (FPGA) presents a higher sensitivity than the clock resource, which is a contrary finding to the previous results. Besides, it is found that there seems to be a micro latch-up window in the SiP. Moreover, this SiP demonstrates different TDRE for enabled PROM and disabled PROM cases, and it has an automatic reconfiguration process in the case of enabled PROM. These findings are followed by a detailed analysis and discussion.
- 12 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (8) , 1840-1849
Experimental Study of Transient Dose Rate Effect on System-in-Package SZ0501
This article investigates the transient dose rate effect (TDRE) on the system-in-package (SiP) SZ0501 experimentally. A specialized program is designed for TDRE tests. With the increase of dose rates, the failure features of the SiP are recorded. Photocurrents on each power supply line are also measured to assist in analyzing SiP failures. In addition, both enabled and disabled programmable read-only memory (PROM) cases are considered to compare their discrepancies. The experimental results show that high frequency (HF) signals in the SiP are much sensitive to TDRE. Also, the logical resource in its field-programmable gate array (FPGA) presents a higher sensitivity than the clock resource, which is a contrary finding to the previous results. Besides, it is found that there seems to be a micro latch-up window in the SiP. Moreover, this SiP demonstrates different TDRE for enabled PROM and disabled PROM cases, and it has an automatic reconfiguration process in the case of enabled PROM. These findings are followed by a detailed analysis and discussion.
- 5 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (5) , 1157-1166
Experimental Study of Transient Dose Rate Effects of Two Level-Shifting Transceivers and Simulations on Their ESD Circuits
This article investigates the transient dose rate effect (TDRE) of two types of level-shifting transceivers. Experimental results show that both transceivers have a high latch-up threshold. One uncommon phenomenon is found that there are photocurrents generated at the input ports for both transceivers when exposed to transient$\gamma $ radiation. Moreover, the polarity and amplitude of the photocurrents are related to the input voltage level. A hypothesis is proposed that this uncommon phenomenon is caused by the electrostatic discharge (ESD) circuits at the input ports and then it is successfully verified by TCAD simulations. The simulation results show that the vertical parasitic p-n-p transistor in pMOS of the ESD circuit could turn on under transient$\gamma $ radiation, and generate a positive photocurrent when the input port is configured to high-level voltage. On the contrary, when the input port is configured to low-level voltage, its lateral parasitic p-n-p transistor in pMOS could turn on and generate a negative photocurrent. The amplitude of the positive photocurrent is obviously larger than the negative photocurrent due to different gains of the parasitic transistors. Simulation results also show the number of pMOSs in n-well has significant impacts on the amplitude of photocurrents.- 5 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 69 (5) , 1157-1166
Experimental Study of Transient Dose Rate Effects of Two Level-Shifting Transceivers and Simulations on Their ESD Circuits
This article investigates the transient dose rate effect (TDRE) of two types of level-shifting transceivers. Experimental results show that both transceivers have a high latch-up threshold. One uncommon phenomenon is found that there are photocurrents generated at the input ports for both transceivers when exposed to transient$\gamma $ radiation. Moreover, the polarity and amplitude of the photocurrents are related to the input voltage level. A hypothesis is proposed that this uncommon phenomenon is caused by the electrostatic discharge (ESD) circuits at the input ports and then it is successfully verified by TCAD simulations. The simulation results show that the vertical parasitic p-n-p transistor in pMOS of the ESD circuit could turn on under transient$\gamma $ radiation, and generate a positive photocurrent when the input port is configured to high-level voltage. On the contrary, when the input port is configured to low-level voltage, its lateral parasitic p-n-p transistor in pMOS could turn on and generate a negative photocurrent. The amplitude of the positive photocurrent is obviously larger than the negative photocurrent due to different gains of the parasitic transistors. Simulation results also show the number of pMOSs in n-well has significant impacts on the amplitude of photocurrents.