Pu Han
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Pu Han has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Cheng Pan
School of Electrical Engineering and Automation, State Key Laboratory of Power Grid Environmental Protection, Wuhan University, Wuhan, China
4 shared publications - Zijun Pan
School of Electrical Engineering and Automation, Wuhan University, Wuhan, China
4 shared publications Ju Tang
3 shared publicationsShiyi Mao
State Key Laboratory of Power Grid Environmental Protection, School of Electrical Engineering and Automation, Wuhan University, Wuhan, China
3 shared publications- Yuhan Ye
State Key Laboratory of Power Grid Environmental Protection, School of Electrical Engineering and Automation, Wuhan University, Wuhan, China
3 shared publications - Ju Tang
School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China
2 shared publications
Latest Publications
- 3 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (2) , 1420-1429
Contribution of Temperature Gradient to Insulation Performance of Disk-Insulator at DC Voltage—Part I: Surface Charge Accumulation
The temperature gradient significantly affects the surface charge accumulation on disc-type insulators in HVDC GIS/GIL. In this paper, the surface charge accumulation characteristics under various temperature gradients are tested, and a simulation model about electro-thermal coupling is established to provide the theoretical analysis. Experimental results show that the average homo-charge density decreases from 3.79 μC/m2 to 1.57 μC/m2 as temperature gradient increases, which is attributed that the dominant pathway of homo-charge accumulation transfers from surface to bulk conduction. In contrast, the average hetero-charge density increases from 0.98 μC/m2 to 4.82 μC/m2. This is because large temperature gradients cause the electric field near grounded electrode significantly increasing from 1.05 kV/mm to 2.78 kV/mm, thereby massive hetero-charges from the grounded electrode migrate to the nearby insulator surface. This work can provide valuable references for the insulation design of disc-type insulators in DC GIS/GIL.
- 3 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (2) , 1420-1429
Contribution of Temperature Gradient to Insulation Performance of Disk-Insulator at DC Voltage—Part I: Surface Charge Accumulation
The temperature gradient significantly affects the surface charge accumulation on disc-type insulators in HVDC GIS/GIL. In this paper, the surface charge accumulation characteristics under various temperature gradients are tested, and a simulation model about electro-thermal coupling is established to provide the theoretical analysis. Experimental results show that the average homo-charge density decreases from 3.79 μC/m2 to 1.57 μC/m2 as temperature gradient increases, which is attributed that the dominant pathway of homo-charge accumulation transfers from surface to bulk conduction. In contrast, the average hetero-charge density increases from 0.98 μC/m2 to 4.82 μC/m2. This is because large temperature gradients cause the electric field near grounded electrode significantly increasing from 1.05 kV/mm to 2.78 kV/mm, thereby massive hetero-charges from the grounded electrode migrate to the nearby insulator surface. This work can provide valuable references for the insulation design of disc-type insulators in DC GIS/GIL.
- 25 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (2) , 1430-1439
Contribution of Temperature Gradient to Insulation Performance of Disk-Insulator at DC Voltage—Part II: Surface Flashover Properties
The temperature gradient is a crucial factor affecting the flashover characteristics at the gas-solid interface in DC GIS/GIL. This paper proposes a “stepwise approximation” method and utilizes it to measure the charge distribution approaching flashover occurrence (CDAFO). The electric field distribution considering CDAFO is calculated to analyze the effect of surface charge on DC flashover voltage at temperature gradients. The results show that with increasing temperature gradient, both positive and negative flashover voltages gradually decrease. The hetero-charge accumulation increases significantly, with high-density hetero-charge clusters appearing at the moment approaching flashover. These charge clusters greatly enhance the electric field near high-voltage electrode: the maximum electric field under negative voltage increases from 3.64 kV/mm to 4.96 kV/mm, and it increases from 3.45 kV/mm to 5.09 kV/mm under positive voltage. This electric field enhancement leads to the reduction in flashover voltage. This work can provide valuable references for the insulation design of DC GIS/GIL systems under temperature gradients.
- 25 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 33 (2) , 1430-1439
Contribution of Temperature Gradient to Insulation Performance of Disk-Insulator at DC Voltage—Part II: Surface Flashover Properties
The temperature gradient is a crucial factor affecting the flashover characteristics at the gas-solid interface in DC GIS/GIL. This paper proposes a “stepwise approximation” method and utilizes it to measure the charge distribution approaching flashover occurrence (CDAFO). The electric field distribution considering CDAFO is calculated to analyze the effect of surface charge on DC flashover voltage at temperature gradients. The results show that with increasing temperature gradient, both positive and negative flashover voltages gradually decrease. The hetero-charge accumulation increases significantly, with high-density hetero-charge clusters appearing at the moment approaching flashover. These charge clusters greatly enhance the electric field near high-voltage electrode: the maximum electric field under negative voltage increases from 3.64 kV/mm to 4.96 kV/mm, and it increases from 3.45 kV/mm to 5.09 kV/mm under positive voltage. This electric field enhancement leads to the reduction in flashover voltage. This work can provide valuable references for the insulation design of DC GIS/GIL systems under temperature gradients.
- 10 August 2024
- Published by Elsevier in Particuology
- Vol. 94, 173-186
Influence of multi-factor interactions on particle growth during top-spray fluidized bed agglomeration
- 10 August 2024
- Published by Elsevier in Particuology
- Vol. 94, 173-186
Influence of multi-factor interactions on particle growth during top-spray fluidized bed agglomeration
- 9 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (6) , 3140-3149
Effect of Insulation Distance on Surface Charge Accumulation at the Gas–Solid Interface Under DC Voltage
This study aims to investigate the effect of insulation distance on the charge accumulation characteristics at the gas-solid interface under DC voltage. Here a plate-shaped epoxy was selected as the sample, and its charging process was provided by a pair of finger-shaped electrodes. With varying the insulation distance between the electrodes, the surface charge distributions were measured under two cases of charging methods. In Case 1 the applied voltage level was constant while in Case 2 the average field strength was unchanged. As a result, for Case 1, hetero-charge accumulation was the main surface charging mode, and the hetero-charge density increased with the insulation distance. This is mainly because the reduced tangential electric field weakens the migrating process of injected homo-charges to the gas-solid interface. As for Case 2, the main surface charging mode presented a polarity reversal, i.e., from hetero-charge to homo-charge accumulation, with increasing the insulation distance. This phenomenon is attributed to the enhancement of HV electrode injection. At last, the experimental results were analyzed through electric field calculation. This study offers a preliminary understanding of the effect of insulation distance on surface charge accumulation under DC voltage.
- 9 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (6) , 3140-3149
Effect of Insulation Distance on Surface Charge Accumulation at the Gas–Solid Interface Under DC Voltage
This study aims to investigate the effect of insulation distance on the charge accumulation characteristics at the gas-solid interface under DC voltage. Here a plate-shaped epoxy was selected as the sample, and its charging process was provided by a pair of finger-shaped electrodes. With varying the insulation distance between the electrodes, the surface charge distributions were measured under two cases of charging methods. In Case 1 the applied voltage level was constant while in Case 2 the average field strength was unchanged. As a result, for Case 1, hetero-charge accumulation was the main surface charging mode, and the hetero-charge density increased with the insulation distance. This is mainly because the reduced tangential electric field weakens the migrating process of injected homo-charges to the gas-solid interface. As for Case 2, the main surface charging mode presented a polarity reversal, i.e., from hetero-charge to homo-charge accumulation, with increasing the insulation distance. This phenomenon is attributed to the enhancement of HV electrode injection. At last, the experimental results were analyzed through electric field calculation. This study offers a preliminary understanding of the effect of insulation distance on surface charge accumulation under DC voltage.
- 12 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (1) , 193-203
Partial Discharge Induced Decomposition Properties and Mechanism of HFO-Butene/CO2 as Eco-Friendly Gas Insulating Medium
HFO-butene [HFO-1336 mzz(E)] has been explored as an eco-friendly gas-insulating medium to replace the most greenhouse gas sulfur fluoride (SF6) for the power industry. At present, studies on the stability and decomposition mechanism of HFO-butene mainly focus on neutral molecules or radicals. However, the discharge-induced decomposition will generate positive and negative ions, which significantly affect the physicochemical properties of gas composition. Meanwhile, experimental evaluation of the partial discharge (PD) induced decomposition characteristics of HFO-butene is lacking. In this article, the decomposition mechanism of HFO-butene considering free radicals and ions is systematically explored for the first time. The molecular structure, ionization, and attachment properties of HFO-butene are revealed, and the reaction enthalpy analysis of the decomposition and by-product generation pathways are explored. The long-term PD experiments on HFO-butene/CO2 gas mixture are conducted combined with gas composition analysis under different applied voltage, gas pressure, and mixing ratio conditions. Relevant results provide an important reference for understanding the PD decomposition characteristics of HFO-butene.
- 12 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 31 (1) , 193-203
Partial Discharge Induced Decomposition Properties and Mechanism of HFO-Butene/CO2 as Eco-Friendly Gas Insulating Medium
HFO-butene [HFO-1336 mzz(E)] has been explored as an eco-friendly gas-insulating medium to replace the most greenhouse gas sulfur fluoride (SF6) for the power industry. At present, studies on the stability and decomposition mechanism of HFO-butene mainly focus on neutral molecules or radicals. However, the discharge-induced decomposition will generate positive and negative ions, which significantly affect the physicochemical properties of gas composition. Meanwhile, experimental evaluation of the partial discharge (PD) induced decomposition characteristics of HFO-butene is lacking. In this article, the decomposition mechanism of HFO-butene considering free radicals and ions is systematically explored for the first time. The molecular structure, ionization, and attachment properties of HFO-butene are revealed, and the reaction enthalpy analysis of the decomposition and by-product generation pathways are explored. The long-term PD experiments on HFO-butene/CO2 gas mixture are conducted combined with gas composition analysis under different applied voltage, gas pressure, and mixing ratio conditions. Relevant results provide an important reference for understanding the PD decomposition characteristics of HFO-butene.
- 11 July 2023
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 56 (40) , 405106
Understanding the effect of SiC/epoxy coating on surface flashover under DC voltage: from surface charge accumulation
Charge accumulation at the insulator surface significantly alters the electric field distribution under DC voltage and can lead to unpredictable flashover. It is realized that the surface flashover voltage is reliant on the charge distribution approaching flashover occurrence (CDAFO). A method of how to judge the moment approaching flashover was proposed in this study to clarify how surface charges induced flashover, whereby the dynamic distributions of surface charges, including the CDAFO, were obtained from the instant of voltage application to the moment approaching flashover. The resulting flashover was analyzed with regards to insulators coated in SiC/epoxy, including an examination of the dominant charging pathway during voltage rising and a discussion of the relationship between the CDAFO and flashover voltage. Despite voltage polarities and SiC content, a reversal of charge polarity from hetero-polar to homo-polar was observed during voltage rising. Furthermore, it was discovered that the CDAFO was homo-charge accumulation, and an increase in SiC content resulted in greater homo-charges. A theory outlining homo-charge’s enhancement of flashover voltage by weakening the electric field near the high voltage electrode was also proposed. Consequently, because of the improved effect of homo-charges on flashover voltage, the addition of SiC led to the boost of flashover voltage.
- 11 July 2023
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 56 (40) , 405106
Understanding the effect of SiC/epoxy coating on surface flashover under DC voltage: from surface charge accumulation
Charge accumulation at the insulator surface significantly alters the electric field distribution under DC voltage and can lead to unpredictable flashover. It is realized that the surface flashover voltage is reliant on the charge distribution approaching flashover occurrence (CDAFO). A method of how to judge the moment approaching flashover was proposed in this study to clarify how surface charges induced flashover, whereby the dynamic distributions of surface charges, including the CDAFO, were obtained from the instant of voltage application to the moment approaching flashover. The resulting flashover was analyzed with regards to insulators coated in SiC/epoxy, including an examination of the dominant charging pathway during voltage rising and a discussion of the relationship between the CDAFO and flashover voltage. Despite voltage polarities and SiC content, a reversal of charge polarity from hetero-polar to homo-polar was observed during voltage rising. Furthermore, it was discovered that the CDAFO was homo-charge accumulation, and an increase in SiC content resulted in greater homo-charges. A theory outlining homo-charge’s enhancement of flashover voltage by weakening the electric field near the high voltage electrode was also proposed. Consequently, because of the improved effect of homo-charges on flashover voltage, the addition of SiC led to the boost of flashover voltage.
- Open Access
- 1 January 2022
- Published by AIP Publishing in AIP Advances
- Vol. 12 (1) , 015206
Effect of O2 on partial discharge and decomposition characteristics of C5F10O/CO2/O2 gas mixture
This paper investigates the effect of O2 on the partial discharge (PD) and decomposition characteristics of C5F10O/CO2/O2 gas mixture employed as an eco-friendly gas insulating medium. We found that the insulation performance of the C5F10O/CO2/O2 gas mixture is less degraded as the content of O2 is less than 4%. However, PDIV+ is significantly reduced, and the discharge repetition rate increases drastically when the O2 content exceeds 4%. The PD decomposition products of C5F10O/CO2/O2 mainly include CF4, C2F6, C3F8, C3F6, CF2O, C2F6O3, and C3F7H. The addition of 2% O2 has a strong inhibitory effect on the generation of CF4, C2F6, C3F6, C3F8, CF2O, and C2F6O3. This work provides guidance for the application of the C5F10O/CO2/O2 gas mixture.
- 1 January 2022
- Published by AIP Publishing in AIP Advances
- Vol. 12 (1) , 015206
Open AccessEffect of O2 on partial discharge and decomposition characteristics of C5F10O/CO2/O2 gas mixture
This paper investigates the effect of O2 on the partial discharge (PD) and decomposition characteristics of C5F10O/CO2/O2 gas mixture employed as an eco-friendly gas insulating medium. We found that the insulation performance of the C5F10O/CO2/O2 gas mixture is less degraded as the content of O2 is less than 4%. However, PDIV+ is significantly reduced, and the discharge repetition rate increases drastically when the O2 content exceeds 4%. The PD decomposition products of C5F10O/CO2/O2 mainly include CF4, C2F6, C3F8, C3F6, CF2O, C2F6O3, and C3F7H. The addition of 2% O2 has a strong inhibitory effect on the generation of CF4, C2F6, C3F6, C3F8, CF2O, and C2F6O3. This work provides guidance for the application of the C5F10O/CO2/O2 gas mixture.