XCXiaodong Cheng

Xiaodong Cheng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xiaodong Cheng has a total of 44 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Unilateral External Fixator Combined with Lateral Auxiliary Frame for Ultimate Treatment of Tibia and Fibula Shaft Fractures with Poor Soft Tissue Conditions

    by Xinhui Wang, Bao Wang, Xizhi Hou, Xiaodong Cheng, Tao Zhang

    Background. For severe soft tissue damage or open fracture, unilateral external fixation is one of the treatment choices. In the current study, a unilateral external fixator combined with a lateral auxiliary frame was used to treat tibia and fibula shaft fractures with poor soft tissue conditions to verify its feasibility for the ultimate treatment. Methods. We retrospectively analyzed the patients with tibia and fibula shaft fractures who underwent unilateral external fixator combined with lateral auxiliary frame between December 2018 and October 2020. The clinical outcomes were recorded. Results. 31 patients with tibia and fibula shaft fractures who received unilateral external fixator combined with lateral auxiliary frame were included in the current study. Among them, 23 cases had closed fractures with poor soft tissue and 8 cases had Gastilo type I open fractures. The average duration of hospital stay was 7.3 ± 2.3 days. The causes of injury were traffic accidents in 15 cases (48.4%), fall from height in 7 cases (22.6%), crush injury in 5 cases (16.1%), and other causes in 4 cases (12.9%). During follow‐up, the clinical healing time was 3.0 ± 0.85 months. Additionally, the infection rate of pin‐tract and reoperation rate was 12.9% and 3.2%. Fortunately, all patients achieved fracture healing and recovered well without joint dysfunction and obvious claudication. The Johner‐Wruh scores showed that 27 cases (87.1%) were “excellent” and 4 cases (12.9%) were “good.” Conclusions. The unilateral external fixator combined with lateral auxiliary frame is an effective option for ultimate treatment of the tibia and fibula shaft fractures with poor soft tissue conditions.


  • Open Access

    Comparison of the Effect of Rhombic and Inverted Triangle Configurations of Cannulated Screws on Internal Fixation of Nondisplaced Femoral Neck Fractures in Elderly Patients

    by Jian Zhu, Xiangtian Deng, Hongzhi Hu, Xiaodong Cheng, Zhanchao Tan, Yingze Zhang

    Objective: To investigate whether four‐screw fixation in rhombic configuration could improve the clinical outcomes and decrease the complication rate compared with three‐screw fixation in inverted triangle configuration in elderly patients with nondisplaced femoral neck fractures.Method: From January 2018 to January 2019, 91 elderly patients with nondisplaced femoral neck fractures who were treated with a cannulated screw system were reviewed retrospectively. The inverted triangle configuration was applied in 51 patients and rhombic configuration in 40 patients. The demographic and perioperative information of the patients were extracted from medical records and surgical records. Variables including incision size, surgical blood loss, surgical time, fluoroscopy time, hospital stays, fracture union time, postoperative visual analogue scale (VAS) scores, and complications were compared between the two groups. Also, Harris hip score at the final follow‐up was used to evaluate the functional outcomes.Results: All patients were followed up from 24 to 36 months, with an average of 29.75 months. The average age of patients was 72.37 ± 7.16 years. No significant differences were found between the two groups with regard to patients' age, gender, affected side, Garden classification, Pauwels classification and comminution of posterior wall (P > 0.05). We found shorter incision size (P < 0.001), less blood loss (P = 0.020), less surgical time (P = 0.026), and shorter fluoroscopy time (P < 0.001) in inverted triangle configuration group. However, shorter hospital stays (P = 0.001) and fracture union time (P = 0.002) were found in the rhombic configuration group. The VAS scores were lower in the rhombic configuration group at the first (P < 0.001) and third months (P = 0.010), but no significant difference was found at the sixth month (P = 0.075). Meanwhile, the total complication rate was relatively lower in the rhombic configuration group compared to the inverted triangle configuration group (P = 0.041). Harris hip score presented no significant difference between the two groups at final follow‐up (P = 0.078). No wound infection or cortical perforation occurred in either group.Conclusion: Four‐screw fixation in rhombic configuration was superior to three‐screw fixation in inverted triangle configuration in the treatment of nondisplaced femoral neck fractures in elderly patients in terms of less early postsurgical pain, shorter fracture union time, and lower complication rate.


  • Open Access

    Clinical Outcome and Biomechanical Analysis of Dynamic Hip Screw Combined with Derotation Screw in Treating Displaced Femoral Neck Fractures Based on Different Reduction Qualities in Young Patients (≤65 Years of Age)

    by Jian Zhu, Yonglong Li, Yingze Zhang, Xiaodong Cheng

    Objective. To examine the clinical results and biomechanical mechanism of the dynamic hip screw (DHS) and derotation screw (DS) in the treatment of displaced femoral neck fractures (FNF) based on different reduction qualities in young patients (≤65 years of age). Methods. All patients with FNF who received closed reduction and internal fixation with DHS+DS from January 2014 to August 2019 were retrospectively analyzed. Data on demographics, surgery, clinical outcomes, and postoperative complications were collected. According to the reduction quality immediately after surgery, all patients were categorized into the positive buttress reduction group (PBRG) and the anatomical reduction group (ARG). The complications and clinical outcomes were compared between the two groups. Meanwhile, the biomechanical mechanism of different reduction qualities was further analyzed with finite element analysis (FEA). The distribution of von Mises stress, the peak stress of internal fixation, and the displacement of the proximal fragment were compared between the two groups. Results. A total of 68 patients were included in our study. Among them, 31 were divided into the PBRG while 37 were in the ARG. The surgical time and fluoroscopy time were significantly shorter in the PBRG than in the ARG (p < 0.05). The degree of femoral neck shortening and the varus change of the femoral‐neck shaft angle were lower in the PBRG compared to the ARG (p < 0.05). The excellent‐good rate of the Harris hip score was higher in the PBRG compared to the ARG (83.9% vs. 64.8%). The FEA results demonstrated that the stress of DHS+CS and the downward displacement of the proximal femoral neck fragment were greater in the ARG than in the PBRG. Conclusion. For displaced FNF with difficulty to achieve reduction, DHS+CS combined with positive buttress reduction was an effective treatment in young patients due to better mechanical support, shorter surgical time, less radiation exposure, and higher excellent‐good rate of Harris hip score.


  • Open Access

    Titanium alloy cannulated screws and biodegradable magnesium alloy bionic cannulated screws for treatment of femoral neck fractures: a finite element analysis

    by Kai Ding, Weijie Yang, Jian Zhu, Xiaodong Cheng, Haicheng Wang, Du Hao, Song Yinuo, Yanbin Zhu, Yingze Zhang, Wei Chen, et al.

    Background: Cannulated screws (CS) are one of the most widely used treatments for femoral neck fracture, however, associated with high rate of complications. In this study, we designed a new type of cannulated screws called degradable magnesium alloy bionic cannulated screws (DMBCS) and our aim was to compare the biomechanical properties of DMBCS, the traditionally used titanium alloy bionic cannulated screws (TBCS) and titanium alloy cannulated screws (TTCS). Methods: A proximal femur model was established based on CT data of a lower extremity from a voluntary healthy man. Garden type III femoral neck fracture was constructed and fixed with DMBCS, TBCS, and TTCS, respectively. Biomechanical effect which three type of CS models have on femoral neck fracture was evaluated and compared using von Mises stress distribution and displacement. Results: In the normal model, the maximum stress value of cortical bone and cancellous bone was 76.18 and 6.82 MPa, and the maximum displacement was 5.52 mm. Under 3 different fracture healing status, the stress peak value of the cortical bone and cancellous bone in the DMBCS fixation model was lower than that in the TTCS and TBCS fixation, while the maximum displacement of DMBCS fixation model was slightly higher than that of TTCS and TBCS fixation models. As the fracture heals, stress peak value of the screws and cortical bone of intact models are decreasing, while stress peak value of cancellous bone is increasing initially and then decreasing. Conclusions: The DMBCS exhibits the superior biomechanical performance than TTCS and TBCS, whose fixation model is closest to the normal model in stress distribution. DMBCS is expected to reduce the rates of post-operative complications with traditional internal fixation and provide practical guidance for the structural design of CS for clinical applications.


  • Open Access

    Comparison of total patellectomy and osteosynthesis with tension band wiring in patients with highly comminuted patella fractures: a 10–20-year follow-up study

    by Xiangtian Deng, Lian Zhu, Hongzhi Hu, Jian Zhu, Weijian Liu, Junzhe Zhang, Sifan Yang, Zhipeng Ye, Haitao Guan, Boyu Zhang, et al.

    The purpose of this study was to evaluate and compare the long-term clinical outcomes between the total patellectomy and osteosynthesis with tension band wiring in patients with highly comminuted patella fractures. Between January 1987 and December 2003, this retrospective study included a total of 35 patients (mean age, 51.4±16.8 years) with a minimum of 10 years follow-up period, comprising 29 males and 6 females, who were divided into the total patellectomy group (17 patients) or the open reduction and internal fixation (ORIF) group (18 patients) in the Third Affiliated Hospital of Hebei Medical University. We retrospectively collected patient demographics and data on the type of trauma, fracture type, and postoperative complications. Clinical outcomes including knee range of motion (ROM), 36-Item Short-Form Health Survey (SF-36) score [including physical component score (PCS) and mental component score (MCS)], Knee Injury and Osteoarthritis Outcome Score (KOOS), and Kujala score were evaluated and compared between the two groups. Biodex System dynamometer was used to quantitatively evaluate quadriceps femoris muscle power following measurement of peak torque. The mean follow-up periods of the total patellectomy group and the ORIF group were 17.2±5.6 and 16.8±4.9 years, respectively. There were no significant differences between the two groups of patient demographics in terms of the number of patients, age, sex, injury side, time to surgery, type of trauma, and fracture classification (p>0.05). Total patellectomy was comparable to osteosynthesis with tension band wiring in terms of ROM [injured knee: 120.4±3.1° vs 118.6±3.3°; uninjured knee: 126.5±2.8° vs 127.3±1.7°; both p>0.05], peak torque [Injured knee: 96.2±2.3 vs 97.3±2.6, N· m; Uninjured knee: 107.6±2.1 vs 106.3±1.8, N· m; both p>0.05], SF-36 score [PCS: 64.1±18.0 vs 61.5±17.9; MCS: 55.1±13.8 vs 54.3±12.4; both p>0.05], KOOS score [76.3±12.1 vs 73.4±11.7; p>0.05], and Kujala score [67.6±11.8 vs 70.8±11.9; p>0.05] at the final follow-up, while total patellectomy had significantly shorter operation time than ORIF group (47.5±12.1 vs 68.8±22.3, min, p<0.05). In the total patellectomy group, complications occurred in 6 of 17 cases (35.3%), and all occurred with calcification. In the ORIF group, complications occurred in 12 of 18 cases (66.7%), including 2 cases of infection (11.1%), 1 case of non-union (5.6%), 2 cases of implant failure (11.1%), 2 cases of soft tissue irritation (11.1%), and 5 cases of patellofemoral arthritis (27.8%). Total patellectomy technique was a safe and reliable alternative treatment for treating patients with highly comminuted patella fractures when anatomically reduction and rigid fixation were difficult, although it caused relatively higher rates of calcification.


  • Open Access

    Finite Element Analysis of a Novel Anterior Locking Plate for Thoracolumbar Burst Fracture

    by Pengcheng Ren, Xiaodong Cheng, Chongyao Lu, Haotian Wu, Shuangquan Yao, Sidong Yang, Zhaohui Song

    Purpose. The finite element analysis method was used to explore the biomechanical stability of a novel locking plate for thoracolumbar burst fracture fusion fixation. Methods. The thoracolumbar CT imaging data from a normal volunteer was imported into finite software to build a normal model and three different simulated surgical models (the traditional double‐segment fixation model A, the novel double‐segment fixation model B, and the novel single‐segment fixation model C). An axial pressure (500 N) and a torque (10 Nm) were exerted on the end plate of T12 to simulate activity of the spine. We recorded the range of motion (ROM) and the maximum stress value of the simulated cages and internal fixations. Results. Model A has a larger ROM in all directions than model B (flexion 5.63%, extension 38.21%, left rotation 46.51%, right rotation 39.76%, left bending 9.45%, and right bending 11.45%). Model C also has a larger ROM in all directions than model B (flexion 555.63%, extension 51.42%, left rotation 56.98%, right rotation 55.42%, left bending 65.67%, and right bending 59.47%). The maximum stress of the cage in model A is smaller than that in model B except for the extension direction (flexion 96.81%, left rotation 175.96%, right rotation 265.73%, left bending 73.73%, and right bending 171.28%). The maximum stress value of the internal fixation in model A is greater than that in model B when models move in flexion (20.23%), extension (117.43%), and left rotation (21.34%). Conclusion. The novel locking plate has a smaller structure and better performance in biomechanical stability, which may be more compatible with minimally invasive spinal tubular technology.


  • Open Access

    Volar, Splitting, and Collapsed Type of Die‐Punch Fracture Treated by Volar Locking Plate (VLP): A Retrospective Study

    by Bing Zhang, Pan Hu, Xiao‐Dong Cheng, Yan‐Bin Zhu, Ling‐De Kong, Xu Zhang, De‐Hu Tian, Ying‐Ze Zhang

    Objective To compare the results of different types of die‐punch fractures treated by volar locking plate (VLP). Methods Between January 2013 and February 2018, a total of 71 patients with die‐punch fracture of distal radius were treated by VLP and their medical records were retrospectively reviewed. Of them, 18 were classified as volar type, 24 as splitting type, and 28 as collapsed type of fracture, based on the preoperative radiographs and CT scans. The minimum follow‐up period was 12 months. Radiological parameters, wrist function, range of motion (ROM), and complications were evaluated and compared. Pearson chi‐square test was used to assess the difference of gender distribution, injury side, dominance, mechanism, type and classification of fracture, and postoperative complications, when necessary (P < 0.05), followed by pairwise comparisons using partitions of chi‐square test. Two‐tailed P value P < 0.017 (0.05/3) was used. SPSS 21.0 was used to perform all the analyses. Results The mean follow‐up time was 14.5 months, and at the mean of postoperative 8 weeks all patients obtained bony union, without delayed or non‐union. The grip strength was 26.6 ± 7.9 kg for patients in volar fracture group, 27.0 ± 9.4 kg in splitting group, and 26.2 ± 9.4 kg in collapsed group, without significant difference (P = 0.628).The disabilities of the arm, shoulder, and hand (DASH) (9.2 ± 10.0 for volar group, 8.8 ± 7.9 for splitting group, and 10.6 ± 8.7 for collapsed group) or Gartland–Werley score (5.1 ± 2.8 for volar group, 4.8 ± 3.2 for splitting group, and 6.4 ± 2.7 for collapsed group) either did not differ among the three groups (all P > 0.05). There was a poorer ROM in the group of collapsed fractures, but the difference was non‐significant for any parameter (P > 0.05). As for radiographic parameters, we did not find any significant difference for volar tilt, radial inclination, radial height, and ulnar variance (all P > 0.05), except for articular step‐off (P < 0.001). Pairwise comparisons showed a significantly greater step‐off (1.2 mm vs 0.4 mm, 0.5 mm) and higher rate of total complications in group of collapsed fracture (39.3%), compared to either volar (10.5%) or splitting type (12.5%). Conclusions The collapsed type of die‐punch fracture posed a greater articular step‐off and a higher rate of complications, especially secondary wrist osteoarthritis, which deserved more attention in clinical treatment.


  • Open Access

    Biomechanical Comparison of Three Internal Fixation Techniques for Stabilizing Posterior Pelvic Ring Disruption: A 3D Finite Element Analysis

    by Pan Hu, Tao Wu, Hui‐Zhi Wang, Xin‐Zheng Qi, Jie Yao, Xiao‐Dong Cheng, Wei Chen, Ying‐Ze Zhang

    Objective: To compare the biomechanical stability and compatibility of two iliosacral screws (ISS), a tension band plate (TBP), and a minimally invasive adjustable plate (MIAP) for treating Tile C pelvic fractures.Methods: Three groups of finite element models of the intact pelvis, including the main ligament and the proximal one‐third of both femurs, were developed to simulate vertical sacral fractures and treated with the three abovementioned internal fixation techniques. A 500 N vertical load, a 500 N vertical load plus a 10 Nm moment of forward sagittal direction, and 500 N vertical load plus a 10 Nm moment of right lateral direction were applied to the sacrum to simulate standing status, bending status, and flexion status, respectively. The maximum displacement value, the stress value, and the stress value of the fracture interface were compared among the three internal fixation techniques.Results: The results showed that all three internal fixation techniques effectively restored the biomechanical transmission of the injured pelvis. The stress on the implants in the TBP model was 167.47% and 53.41% higher than that in the ISS model and the MIAP model, respectively, and the stress shielding phenomenon of the TBP model was more obvious than in the other two models. Meanwhile, the stress between the fracture interfaces in the TBP fixation models was apparently higher than that in the other two models. However, the vertical displacement of the MIAP model was not significantly different from that in the ISS and TBP model; therefore, strong fixation could be obtained in all three models.Conclusion: Based on our results, we believe that the stability of Tile C pelvic fracture fixed with MIAP was similar to that of fractures fixed with ISS and TBP, but the stress shielding phenomenon and safety of implants in the TBP models were inferior to those in the MIAP and ISS fixation models. Meanwhile, MIAP and ISS fixation were more helpful to the healing processing than was TBP fixation, especially at the fracture interface of the second and third vertebral body levels.