Chao Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chao Zhang has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Yang Yang
School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
7 shared publications - Bin Yang
University of Shanghai for Science and Technology
3 shared publications Wen Ha
School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, People’s Republic of China
3 shared publicationsDong Wang
2 shared publications- Yueshe Wang
State Key Laboratory of Multiphase Flow in Power Engineering Xi'an Jiaotong University Xi'an China
2 shared publications Zhichao Zhang
2 shared publications
Latest Publications
- 1 March 2026
- Published by IOP Publishing in Engineering Research Express
- Vol. 8 (6) , 065513
Measurement of Taylor bubble parameters in vertical slug flow using ultrasonic reflection and cross-correlation
This paper proposes a measurement method integrating ultrasonic reflection and cross-correlation techniques to achieve accurate characterization of Taylor bubble velocity and length in vertical gas–liquid slug flows. The optimal sensor spacing was determined through rigorous cross-correlation analysis of the experimental data. By employing two ultrasonic sensors in an upstream-downstream configuration, ultrasonic reflection signals were captured to extract the gas–liquid interfacial information of Taylor bubbles under various flow conditions. Validation against simultaneous image-based measurements demonstrates that the relative errors for both velocity and length are within ±8%. This research provides a robust, non-invasive approach for measuring key parameters associated with Taylor bubble dynamics.
- 1 March 2026
- Published by IOP Publishing in Engineering Research Express
- Vol. 8 (6) , 065513
Measurement of Taylor bubble parameters in vertical slug flow using ultrasonic reflection and cross-correlation
This paper proposes a measurement method integrating ultrasonic reflection and cross-correlation techniques to achieve accurate characterization of Taylor bubble velocity and length in vertical gas–liquid slug flows. The optimal sensor spacing was determined through rigorous cross-correlation analysis of the experimental data. By employing two ultrasonic sensors in an upstream-downstream configuration, ultrasonic reflection signals were captured to extract the gas–liquid interfacial information of Taylor bubbles under various flow conditions. Validation against simultaneous image-based measurements demonstrates that the relative errors for both velocity and length are within ±8%. This research provides a robust, non-invasive approach for measuring key parameters associated with Taylor bubble dynamics.
- 1 July 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (7)
Gas–liquid two-phase flow measurement by ultrasonic method based on the phase-isolation and dual-fluid model
Considering the inability of ultrasonic methods to effectively measure gas velocity in gas-liquid two-phase flow, as ultrasonic waves cannot penetrate the gas phase, this paper proposes a gas-liquid two-phase flow measurement method based on the phase-isolation and dual fluid model. Before measurements, the phase-isolation technique is employed to convert the inlet flow pattern into a swirling annular flow pattern. Two typical inlet flow patterns, bubbly flow and slug flow, are selected to investigate how flow fluctuation under different conditions affects ultrasonic measurements. The liquid film thickness is initially determined using ultrasonic reflection, followed by liquid film velocity measurement with the method of ultrasonic Doppler. Finally, gas velocity is obtained by combining ultrasonic cross correlation velocity and the dual fluid model. The results show that the liquid film thickness of swirling annular flow exhibits an exponential trend under the inlet pattern of slug flow as the superficial liquid velocity varies. For liquid velocity measurements, the relative errors for the inlet flow patterns of bubbly flow and slug flow are respectively within ±6% and ±8%. For gas velocity measurements, the relative errors for the inlet flow patterns of bubbly flow and slug flow are within ±7% and ±12%, respectively.
- 1 July 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (7)
Gas–liquid two-phase flow measurement by ultrasonic method based on the phase-isolation and dual-fluid model
Considering the inability of ultrasonic methods to effectively measure gas velocity in gas-liquid two-phase flow, as ultrasonic waves cannot penetrate the gas phase, this paper proposes a gas-liquid two-phase flow measurement method based on the phase-isolation and dual fluid model. Before measurements, the phase-isolation technique is employed to convert the inlet flow pattern into a swirling annular flow pattern. Two typical inlet flow patterns, bubbly flow and slug flow, are selected to investigate how flow fluctuation under different conditions affects ultrasonic measurements. The liquid film thickness is initially determined using ultrasonic reflection, followed by liquid film velocity measurement with the method of ultrasonic Doppler. Finally, gas velocity is obtained by combining ultrasonic cross correlation velocity and the dual fluid model. The results show that the liquid film thickness of swirling annular flow exhibits an exponential trend under the inlet pattern of slug flow as the superficial liquid velocity varies. For liquid velocity measurements, the relative errors for the inlet flow patterns of bubbly flow and slug flow are respectively within ±6% and ±8%. For gas velocity measurements, the relative errors for the inlet flow patterns of bubbly flow and slug flow are within ±7% and ±12%, respectively.
- 1 May 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (5)
Quantitative description of self-, Maxwell–Stefan, and Fick diffusion coefficients in sucrose and citric acid solution based on molecular dynamics simulations
The diffusion coefficient plays a crucial role in predicting the equilibration timescale of atmospheric aerosol particles, however current knowledge on the subject remains limited. In this study, the self-, Maxwell–Stefan, and Fick diffusion coefficients in sucrose (SC) and citric acid (CA) solution are investigated using the molecular dynamics (MD) method. Key aspects include comparisons with experimental and theoretical models, as well as the effects of temperature and solute concentration on diffusion coefficients. The results demonstrate that MD results align well with experimental data. Additionally, the McCarty–Mason equation and the Darken equation generally underpredict the self- and Maxwell–Stefan diffusion coefficients, respectively. The self-, Maxwell–Stefan, and Fick diffusion coefficients in SC and CA solutions exhibit a positive correlation with temperature and a negative correlation with solute mass fraction. Furthermore, the intensity of these influences varies: the impact of solute mass fraction on diffusion coefficients decreases with increasing temperature, while the effect of temperature diminishes with higher solute concentrations. Moreover, based on the MD simulation results, fitting formulas for the diffusion coefficients are also developed. This study underscores the value of the MD simulation method in accurately describing diffusion coefficients in solutions containing complex components.
- 1 May 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (5)
Quantitative description of self-, Maxwell–Stefan, and Fick diffusion coefficients in sucrose and citric acid solution based on molecular dynamics simulations
The diffusion coefficient plays a crucial role in predicting the equilibration timescale of atmospheric aerosol particles, however current knowledge on the subject remains limited. In this study, the self-, Maxwell–Stefan, and Fick diffusion coefficients in sucrose (SC) and citric acid (CA) solution are investigated using the molecular dynamics (MD) method. Key aspects include comparisons with experimental and theoretical models, as well as the effects of temperature and solute concentration on diffusion coefficients. The results demonstrate that MD results align well with experimental data. Additionally, the McCarty–Mason equation and the Darken equation generally underpredict the self- and Maxwell–Stefan diffusion coefficients, respectively. The self-, Maxwell–Stefan, and Fick diffusion coefficients in SC and CA solutions exhibit a positive correlation with temperature and a negative correlation with solute mass fraction. Furthermore, the intensity of these influences varies: the impact of solute mass fraction on diffusion coefficients decreases with increasing temperature, while the effect of temperature diminishes with higher solute concentrations. Moreover, based on the MD simulation results, fitting formulas for the diffusion coefficients are also developed. This study underscores the value of the MD simulation method in accurately describing diffusion coefficients in solutions containing complex components.
- 1 January 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (1)
Quantitative description of surface tension for nanodroplets containing ammonium sulfate and its application to the particle hygroscopicity prediction
Surface tension is critically important in the hygroscopicity prediction of nano-aerosols, but experimental measurements of suspended nanodroplet surface tension are currently unattainable. In this study, effect of size and solute concentration on the surface tension of aqueous ammonium sulfate (AS) droplet smaller than 10 nm is investigated based on molecular dynamics simulations. A surface tension formula is proposed and applied in the theoretical model for particle hygroscopicity, and the prediction is compared with models using traditional methods of surface tension description. Results show that with the increase in AS concentration, surface tension decreases first and then increases, and the correlation between surface tension and droplet size changes from positive to negative. Compared to the surface tension model considering only the AS concentration effect, the surface tension formula including both AS concentration and size corrections enables the particle hygroscopicity model to obtain a smaller hygroscopic growth factor, which is closer to the experimental results. The improvement effect of the new formula on the model accuracy increases with the decreasing particle size. Additionally, the new surface tension formula leads to an increase in the critical supersaturation for particles smaller than 5 nm but a decrease for larger particles. The present study highlights the importance of the molecular dynamics investigation for nanodroplets comprising of complex ingredients.
- 1 January 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (1)
Quantitative description of surface tension for nanodroplets containing ammonium sulfate and its application to the particle hygroscopicity prediction
Surface tension is critically important in the hygroscopicity prediction of nano-aerosols, but experimental measurements of suspended nanodroplet surface tension are currently unattainable. In this study, effect of size and solute concentration on the surface tension of aqueous ammonium sulfate (AS) droplet smaller than 10 nm is investigated based on molecular dynamics simulations. A surface tension formula is proposed and applied in the theoretical model for particle hygroscopicity, and the prediction is compared with models using traditional methods of surface tension description. Results show that with the increase in AS concentration, surface tension decreases first and then increases, and the correlation between surface tension and droplet size changes from positive to negative. Compared to the surface tension model considering only the AS concentration effect, the surface tension formula including both AS concentration and size corrections enables the particle hygroscopicity model to obtain a smaller hygroscopic growth factor, which is closer to the experimental results. The improvement effect of the new formula on the model accuracy increases with the decreasing particle size. Additionally, the new surface tension formula leads to an increase in the critical supersaturation for particles smaller than 5 nm but a decrease for larger particles. The present study highlights the importance of the molecular dynamics investigation for nanodroplets comprising of complex ingredients.
- Open Access
- 1 August 2024
- Published by Elsevier in SSRN Electronic Journal
Theoretical Model of Electromagnetic Flowmeter with Conductive Pipe Wall Based on Weight Function Correlation of Fluid Domain
This paper firstly investigated the weight function distribution in the electromagnetic flowmeter with conductive pipe wall combining the virtual current density method and COMSOL Multiphysics simulation software. It was found the average weight function values are the same in any small ring domain in the pipe wall or fluid. Additionally, the ratio of average weight function of the fluid domain to the pipe wall domain is only related to ratio of their conductivity. Then the correlation of average weight function ratio of the fluid and pipe wall was obtained. The weight function correlation of the fluid domain was subsequently acquired combined with the physical meaning of weight function. Finally, the theoretical model was derived based on the weight function correlation and the control equation of electromagnetic flowmeter. The deviation between this model and the calculation results of the electromagnetic flowmeter model established by COMSOL Multiphysics is less than 4%.
- 1 August 2024
- Published by Elsevier in SSRN Electronic Journal
Open AccessTheoretical Model of Electromagnetic Flowmeter with Conductive Pipe Wall Based on Weight Function Correlation of Fluid Domain
This paper firstly investigated the weight function distribution in the electromagnetic flowmeter with conductive pipe wall combining the virtual current density method and COMSOL Multiphysics simulation software. It was found the average weight function values are the same in any small ring domain in the pipe wall or fluid. Additionally, the ratio of average weight function of the fluid domain to the pipe wall domain is only related to ratio of their conductivity. Then the correlation of average weight function ratio of the fluid and pipe wall was obtained. The weight function correlation of the fluid domain was subsequently acquired combined with the physical meaning of weight function. Finally, the theoretical model was derived based on the weight function correlation and the control equation of electromagnetic flowmeter. The deviation between this model and the calculation results of the electromagnetic flowmeter model established by COMSOL Multiphysics is less than 4%.
- 1 January 2023
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 72 (11) , 114701
Molecular dynamics study on the surface tension of succinic acid-water nano-aerosol droplets
The surface tension plays a significant role in the hygroscopicity of aerosol particles on a nanoscale. However, it cannot be obtained by using the existing measurement techniques. In this study, we simulate the hygroscopic growth of one single succinic acid (SA) particle by using the molecular dynamic (MD) method. Based on the MD simulation results, the surface tension of the stable SA-water droplet is calculated by using a numerical model. Furthermore, the influencing mechanisms of temperature, diameter and concentration of SA on the surface tension of the nanoscale droplet are investigated. The results show that with the temperature increasing from 260 K to 320 K, the surface tension of the droplet decreases, which is mainly caused by the weakening of the intermolecular forces inside the droplet. Besides, the sensitivity of the surface tension to the temperature increases with the increasing SA concentration, which can be explained by the effect of the temperature and the SA concentration on the radial distribution of SA molecules. With the increase of the particle diameter, the surface tension of droplet first increases and then tends to be constant. The normal components of the Irving-Kirkwood pressure tensors are calculated to explain the effect of diameter and SA on the surface tension. In addition, when the SA concentration is increased, the particle diameter range which has an obvious effect on the surface tension is reduced. Moreover, the surface tension of the nanodroplet is negatively correlated with the SA concentration, and the correlation fits into the logarithmic function form, especially for droplet with a diameter smaller than 6.12 nm. The Szyszkowski equation is employed to fit the relationship between SA concentration and the surface tension of droplet. These findings can provide parameter support for improving the theoretical model of particle hygroscopicity and related kinetic processes. This study emphasizes further research on the surface tension of nano-droplets with more complex components.
- 1 January 2023
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 72 (11) , 114701
Molecular dynamics study on the surface tension of succinic acid-water nano-aerosol droplets
The surface tension plays a significant role in the hygroscopicity of aerosol particles on a nanoscale. However, it cannot be obtained by using the existing measurement techniques. In this study, we simulate the hygroscopic growth of one single succinic acid (SA) particle by using the molecular dynamic (MD) method. Based on the MD simulation results, the surface tension of the stable SA-water droplet is calculated by using a numerical model. Furthermore, the influencing mechanisms of temperature, diameter and concentration of SA on the surface tension of the nanoscale droplet are investigated. The results show that with the temperature increasing from 260 K to 320 K, the surface tension of the droplet decreases, which is mainly caused by the weakening of the intermolecular forces inside the droplet. Besides, the sensitivity of the surface tension to the temperature increases with the increasing SA concentration, which can be explained by the effect of the temperature and the SA concentration on the radial distribution of SA molecules. With the increase of the particle diameter, the surface tension of droplet first increases and then tends to be constant. The normal components of the Irving-Kirkwood pressure tensors are calculated to explain the effect of diameter and SA on the surface tension. In addition, when the SA concentration is increased, the particle diameter range which has an obvious effect on the surface tension is reduced. Moreover, the surface tension of the nanodroplet is negatively correlated with the SA concentration, and the correlation fits into the logarithmic function form, especially for droplet with a diameter smaller than 6.12 nm. The Szyszkowski equation is employed to fit the relationship between SA concentration and the surface tension of droplet. These findings can provide parameter support for improving the theoretical model of particle hygroscopicity and related kinetic processes. This study emphasizes further research on the surface tension of nano-droplets with more complex components.
- 1 February 2022
- Published by Elsevier in Chemical Engineering Research and Design
- Vol. 178, 315-327
A novel horizontal gas–liquid pipe separator for wet gas based on the phase-isolation
- 1 February 2022
- Published by Elsevier in Chemical Engineering Research and Design
- Vol. 178, 315-327
A novel horizontal gas–liquid pipe separator for wet gas based on the phase-isolation
- 8 July 2021
- Published by Wiley in Asia-Pacific Journal of Chemical Engineering
- Vol. 16 (5) , e2680
Area‐alterable liquid electrode capacitance sensor for water holdup measurement in oil–water two‐phase flow
Oil–water two‐phase flow exists widely in the process of petroleum industry. The water holdup is an important parameter but difficult to measure. In this paper, we develop an area‐alterable liquid electrode capacitance sensor for water holdup measurement in oil–water two‐phase flow. The capacitance sensor has a relatively high measurement sensitivity and a good linearity in the full range of the water holdup, from 0% to 100%. Meanwhile, a firing technology of insulating layer is presented to guarantee the characteristics of the capacitance sensor with high temperature resistance, corrosion resistance, and non‐stickiness. The static performance of the capacitance sensor is validated theoretically and experimentally. Vertical upward oil–water two‐phase flow experiments indicate that the developed capacitance sensor has good performance for water holdup measurement with average relative error of 10% in the full range of the water holdup. Based on the output signal of the sensor, the information of flow structure can be also estimated in different flow patterns.
- 8 July 2021
- Published by Wiley in Asia-Pacific Journal of Chemical Engineering
- Vol. 16 (5) , e2680
Area‐alterable liquid electrode capacitance sensor for water holdup measurement in oil–water two‐phase flow
Oil–water two‐phase flow exists widely in the process of petroleum industry. The water holdup is an important parameter but difficult to measure. In this paper, we develop an area‐alterable liquid electrode capacitance sensor for water holdup measurement in oil–water two‐phase flow. The capacitance sensor has a relatively high measurement sensitivity and a good linearity in the full range of the water holdup, from 0% to 100%. Meanwhile, a firing technology of insulating layer is presented to guarantee the characteristics of the capacitance sensor with high temperature resistance, corrosion resistance, and non‐stickiness. The static performance of the capacitance sensor is validated theoretically and experimentally. Vertical upward oil–water two‐phase flow experiments indicate that the developed capacitance sensor has good performance for water holdup measurement with average relative error of 10% in the full range of the water holdup. Based on the output signal of the sensor, the information of flow structure can be also estimated in different flow patterns.
- 1 December 2015
- Published by Elsevier in Chemical Engineering Science
- Vol. 137, 308-319
A molecular dynamics study of water vapor nucleation in the presence of ions
- 1 December 2015
- Published by Elsevier in Chemical Engineering Science
- Vol. 137, 308-319
A molecular dynamics study of water vapor nucleation in the presence of ions
- 27 August 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 1757-1761
New dormancy policy in novel smart ad hoc sensor system
- 27 August 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 1757-1761
New dormancy policy in novel smart ad hoc sensor system