ZZZhongshi Zhang

Zhongshi Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhongshi Zhang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Automatic Detection of Camera Rotation Moments in Trans-Nasal Minimally Invasive Surgery Using Machine Learning Algorithm

    by Zhong Shi Zhang, Yun Wu, Bin Zheng

    Background: Minimally invasive surgery (MIS) is an advanced surgical technique that relies on a camera to provide the surgeon with a visual field. When the camera rotates along its longitudinal axis, the horizon of the surgical view tilts, increasing the difficulty of the procedure and the cognitive load on the surgeon. To address this, we proposed training a convolutional neural network (CNN) to detect camera rotation, laying the groundwork for the automatic correction of this issue during MIS procedures. Methods: We collected trans-nasal MIS procedure videos from YouTube and labeled each frame as either “tilted” or “non-tilted”. The dataset consisted of 2116 video frames, with 497 frames labeled as “tilted” and 1619 frames as “non-tilted”. This dataset was randomly divided into three subsets: training (70%), validation (20%), and testing (10%) Results: The ResNet50 was trained on the dataset for 10 epochs, achieving an accuracy of 96.9% at epoch 6 with a validation loss of 0.0242 before validation accuracy began to decrease. On the test set, the model achieved an accuracy of 96% with an average loss of 0.0256. The final F1 score was 0.94, and the Matthews Correlation Coefficient was 0.9168, with no significant bias toward either class. The trained ResNet50 model demonstrated a high success rate in predicting significant camera rotation without favoring the more frequent class in the dataset. Conclusions: The trained CNN accurately detected camera rotation with high precision, establishing a foundation for developing an automatic correction system for camera rotation in MIS procedures.

  • Open Access

    Early Eye Disengagement Is Regulated by Task Complexity and Task Repetition in Visual Tracking Task

    by Yun Wu, Zhongshi Zhang, Farzad Aghazadeh, Bin Zheng

    Understanding human actions often requires in-depth detection and interpretation of bio-signals. Early eye disengagement from the target (EEDT) represents a significant eye behavior that involves the proactive disengagement of the gazes from the target to gather information on the anticipated pathway, thereby enabling rapid reactions to the environment. It remains unknown how task difficulty and task repetition affect EEDT. We aim to provide direct evidence of how these factors influence EEDT. We developed a visual tracking task in which participants viewed arrow movement videos while their eye movements were tracked. The task complexity was increased by increasing movement steps. Every movement pattern was performed twice to assess the effect of repetition on eye movement. Participants were required to recall the movement patterns for recall accuracy evaluation and complete cognitive load assessment. EEDT was quantified by the fixation duration and frequency within the areas of eye before arrow. When task difficulty increased, we found the recall accuracy score decreased, the cognitive load increased, and EEDT decreased significantly. The EEDT was higher in the second trial, but significance only existed in tasks with lower complexity. EEDT was positively correlated with recall accuracy and negatively correlated with cognitive load. Performing EEDT was reduced by task complexity and increased by task repetition. EEDT may be a promising sensory measure for assessing task performance and cognitive load and can be used for the future development of eye-tracking-based sensors.


  • Open Access

    Pupil Response in Visual Tracking Tasks: The Impacts of Task Load, Familiarity, and Gaze Position

    by Yun Wu, Zhongshi Zhang, Yao Zhang, Bin Zheng, Farzad Aghazadeh

    Pupil size is a significant biosignal for human behavior monitoring and can reveal much underlying information. This study explored the effects of task load, task familiarity, and gaze position on pupil response during learning a visual tracking task. We hypothesized that pupil size would increase with task load, up to a certain level before decreasing, decrease with task familiarity, and increase more when focusing on areas preceding the target than other areas. Fifteen participants were recruited for an arrow tracking learning task with incremental task load. Pupil size data were collected using a Tobii Pro Nano eye tracker. A 2 × 3 × 5 three-way factorial repeated measures ANOVA was conducted using R (version 4.2.1) to evaluate the main and interactive effects of key variables on adjusted pupil size. The association between individuals’ cognitive load, assessed by NASA-TLX, and pupil size was further analyzed using a linear mixed-effect model. We found that task repetition resulted in a reduction in pupil size; however, this effect was found to diminish as the task load increased. The main effect of task load approached statistical significance, but different trends were observed in trial 1 and trial 2. No significant difference in pupil size was detected among the three gaze positions. The relationship between pupil size and cognitive load overall followed an inverted U curve. Our study showed how pupil size changes as a function of task load, task familiarity, and gaze scanning. This finding provides sensory evidence that could improve educational outcomes.


  • Open Access

    A Review of Cognitive Support Systems in the Operating Room

    by Zhong Shi Zhang, Yun Wu, Bin Zheng

    Background: In recent years, numerous innovative yet challenging surgeries, such as minimally invasive procedures, have introduced an overwhelming amount of new technologies, increasing the cognitive load for surgeons and potentially diluting their attention. Cognitive support technologies (CSTs) have been in development to reduce surgeons’ cognitive load and minimize errors. Despite its huge demands, it still lacks a systematic review. Methods: Literature was searched up until May 21st, 2021. Pubmed, Web of Science, and IEEExplore. Studies that aimed at reducing the cognitive load of surgeons were included. Additionally, studies that contained an experimental trial with real patients and real surgeons were prioritized, although phantom and animal studies were also included. Major outcomes that were assessed included surgical error, anatomical localization accuracy, total procedural time, and patient outcome. Results: A total of 37 studies were included. Overall, the implementation of CSTs had better surgical performance than the traditional methods. Most studies reported decreased error rate and increased efficiency. In terms of accuracy, most CSTs had over 90% accuracy in identifying anatomical markers with an error margin below 5 mm. Most studies reported a decrease in surgical time, although some were statistically insignificant. Discussion: CSTs have been shown to reduce the mental workload of surgeons. However, the limited ergonomic design of current CSTs has hindered their widespread use in the clinical setting. Overall, more clinical data on actual patients is needed to provide concrete evidence before the ubiquitous implementation of CSTs.


  • Open Access

    Ankle-Injury Patients Perform More Microadjustments during Walking: Evidence from Velocity Profiles in Gait Analysis

    by Xin Liu, Bin Zheng, Qinwei Guo, Yuanyuan Yu, Zhongshi Zhang, Aziguli Wulamu, Dezheng Zhang

    Introduction. We evaluated the velocity profiles of patients with lateral collateral ligament (LCL) injuries of the ankle with a goal of understanding the control mechanism involved in walking. Methods. We tracked motions of patients legs and feet in 30 gait cycles recorded from patients with LCL injuries of the ankle and compared them to 50 gait cycles taken from normal control subjects. Seventeen markers were placed on the foot following the Heidelberg foot measurement model. Velocity profiles and microadjustments of the knee, ankle, and foot were calculated during different gait phases and compared between the patient and control groups. Results. Patients had a smaller first rocker percentage and larger second rocker percentage in the gait cycle compared to controls. Patients also displayed shorter stride length and slower strides and performed more microadjustments in the second rocker phase than in other rocker/swing phases. Patients mean velocities of the knee, ankle, and foot in the second rocker phase were also significantly higher than that in control subjects. Discussion. Evidence from velocity profiles suggested that patients with ligament injury necessitated more musculoskeletal microadjustments to maintain body balance, but these may also be due to secondary injury. Precise descriptions of the spatiotemporal gait characteristics are therefore crucial for our understanding of movement control during locomotion.