Shan Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shan Huang has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Xiaoyang Zeng
State Key Laboratory of ASIC and System, Fudan University, Shanghai, China
5 shared publicationsJun Han
State Key Laboratory of ASIC and System, Fudan University, Shanghai, China
4 shared publicationsYong Hu
University of California Los Angeles
3 shared publicationsJeffrey F. Krane
University of California Los Angeles
2 shared publicationsMaie A. St. John
University of California Los Angeles
2 shared publicationsOscar Stafsudd
Department of Electrical and Computer Engineering Henry Samueli School of Engineering, UCLA Los Angeles California U.S.A.
2 shared publications
Latest Publications
- Open Access
- 13 September 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (9) , 753
The Feasibility of Early Alzheimer’s Disease Diagnosis Using a Neural Network Hybrid Platform
Early diagnosis of Alzheimer’s Disease (AD) is critical for disease prevention and cure. However, currently, techniques with the required high sensitivity and specificity are lacking. Recently, with the advances and increased accessibility of data analysis tools, such as machine learning, research efforts have increasingly focused on using these computational methods to solve this challenge. Here, we demonstrate a convolutional neural network (CNN)-based AD diagnosis approach using the surface-enhanced Raman spectroscopy (SERS) fingerprints of human cerebrospinal fluid (CSF). SERS and CNN were combined for biomarker detection to analyze disease-associated biochemical changes in the CSF. We achieved very high reproducibility in double-blind experiments for testing the feasibility of our system on human samples. We achieved an overall accuracy of 92% (100% for normal individuals and 88.9% for AD individuals) based on the clinical diagnosis. Further, we observed an excellent correlation coefficient between our test score and the Clinical Dementia Rating (CDR) score. Our findings offer a substantial indication of the feasibility of detecting AD biomarkers using the innovative combination of SERS and machine learning. We are hoping that this will serve as an incentive for future research in the field.
- 13 September 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (9) , 753
Open AccessThe Feasibility of Early Alzheimer’s Disease Diagnosis Using a Neural Network Hybrid Platform
Early diagnosis of Alzheimer’s Disease (AD) is critical for disease prevention and cure. However, currently, techniques with the required high sensitivity and specificity are lacking. Recently, with the advances and increased accessibility of data analysis tools, such as machine learning, research efforts have increasingly focused on using these computational methods to solve this challenge. Here, we demonstrate a convolutional neural network (CNN)-based AD diagnosis approach using the surface-enhanced Raman spectroscopy (SERS) fingerprints of human cerebrospinal fluid (CSF). SERS and CNN were combined for biomarker detection to analyze disease-associated biochemical changes in the CSF. We achieved very high reproducibility in double-blind experiments for testing the feasibility of our system on human samples. We achieved an overall accuracy of 92% (100% for normal individuals and 88.9% for AD individuals) based on the clinical diagnosis. Further, we observed an excellent correlation coefficient between our test score and the Clinical Dementia Rating (CDR) score. Our findings offer a substantial indication of the feasibility of detecting AD biomarkers using the innovative combination of SERS and machine learning. We are hoping that this will serve as an incentive for future research in the field.
- 4 January 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (2) , 549-558
Ex vivo hypercellular parathyroid gland differentiation using dynamic optical contrast imaging (DOCI)
Primary hyperparathyroidism, often caused by a single adenoma (80-85%) or four-gland hyperplasia (10-15%), can lead to elevated parathyroid hormone (PTH) levels and resultant hypercalcemia. Surgical excision of offending lesions is the standard of care, as the removal of pathologic adenomas reduces PTH and calcium values to baseline. The small size, variable location, and indistinct external features of parathyroid glands can make their identification quite challenging intraoperatively. Our group has developed the dynamic optical contrast imaging (DOCI) technique, a novel realization of dynamic temporally dependent measurements of tissue autofluorescence. In this study, we evaluated the efficacy of using the DOCI technique and normalized steady-state fluorescence intensity data for differentiating types of human parathyroid and thyroid tissues. We demonstrate that the DOCI technique has the capability to distinguish normal parathyroid tissue from diseased parathyroid glands as well as from adjacent healthy thyroid and adipose tissue across 8 different spectral channels between 405nm-600nm (p). Patient tissue DOCI data was further analyzed with a logistic regression classifier trained across the 8 spectral channels. After computer training, the computer-aided identification was able to accurately locate hypercellular parathyroid tissue with 100% sensitivity and 98.8% specificity within the captured DOCI image.
- 4 January 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (2) , 549-558
Ex vivo hypercellular parathyroid gland differentiation using dynamic optical contrast imaging (DOCI)
Primary hyperparathyroidism, often caused by a single adenoma (80-85%) or four-gland hyperplasia (10-15%), can lead to elevated parathyroid hormone (PTH) levels and resultant hypercalcemia. Surgical excision of offending lesions is the standard of care, as the removal of pathologic adenomas reduces PTH and calcium values to baseline. The small size, variable location, and indistinct external features of parathyroid glands can make their identification quite challenging intraoperatively. Our group has developed the dynamic optical contrast imaging (DOCI) technique, a novel realization of dynamic temporally dependent measurements of tissue autofluorescence. In this study, we evaluated the efficacy of using the DOCI technique and normalized steady-state fluorescence intensity data for differentiating types of human parathyroid and thyroid tissues. We demonstrate that the DOCI technique has the capability to distinguish normal parathyroid tissue from diseased parathyroid glands as well as from adjacent healthy thyroid and adipose tissue across 8 different spectral channels between 405nm-600nm (p). Patient tissue DOCI data was further analyzed with a logistic regression classifier trained across the 8 spectral channels. After computer training, the computer-aided identification was able to accurately locate hypercellular parathyroid tissue with 100% sensitivity and 98.8% specificity within the captured DOCI image.
- 27 May 2021
- Published by Wiley in The Laryngoscope
- Vol. 131 (10) , 2391-2397
A Tool to Locate Parathyroid Glands Using Dynamic Optical Contrast Imaging
Objectives/Hypothesis: Identification of parathyroid glands and adjacent tissues intraoperatively can be quite challenging because of their small size, variable locations, and indistinct external features. The objective of this study is to test the efficacy of the dynamic optical contrast imaging (DOCI) technique as a tool in specifically differentiating parathyroid tissue and adjacent structures, facilitating efficient and reliable tissue differentiation.Study Design: Prospective study.Methods: Both animal and human tissues were included in this study. Fresh specimens were imaged with DOCI and subsequently processed for hematoxylin and eosin (H&E) stain. The DOCI images were analyzed and compared to the H&E results as ground truth.Results: In both animal and human experiments, significant DOCI contrast was observed between parathyroid glands and adjacent tissue of all types. Region of interest analysis revealed most distinct DOCI values for each tissue when using 494 and 572 nm‐specific band pass filter for signal detection (P < .005 for porcine tissues, and P = .02 for human specimens). Linear discriminant classifier for tissue type prediction based on DOCI also matched the underlying histology.Conclusions: We demonstrate that the DOCI technique reliably facilitates specific parathyroid gland localization. The DOCI technique constitutes important groundwork for in vivo precision endocrine surgery.Level of Evidence: 4 Laryngoscope, 131:2391–2397, 2021
- 27 May 2021
- Published by Wiley in The Laryngoscope
- Vol. 131 (10) , 2391-2397
A Tool to Locate Parathyroid Glands Using Dynamic Optical Contrast Imaging
Objectives/Hypothesis: Identification of parathyroid glands and adjacent tissues intraoperatively can be quite challenging because of their small size, variable locations, and indistinct external features. The objective of this study is to test the efficacy of the dynamic optical contrast imaging (DOCI) technique as a tool in specifically differentiating parathyroid tissue and adjacent structures, facilitating efficient and reliable tissue differentiation.Study Design: Prospective study.Methods: Both animal and human tissues were included in this study. Fresh specimens were imaged with DOCI and subsequently processed for hematoxylin and eosin (H&E) stain. The DOCI images were analyzed and compared to the H&E results as ground truth.Results: In both animal and human experiments, significant DOCI contrast was observed between parathyroid glands and adjacent tissue of all types. Region of interest analysis revealed most distinct DOCI values for each tissue when using 494 and 572 nm‐specific band pass filter for signal detection (P < .005 for porcine tissues, and P = .02 for human specimens). Linear discriminant classifier for tissue type prediction based on DOCI also matched the underlying histology.Conclusions: We demonstrate that the DOCI technique reliably facilitates specific parathyroid gland localization. The DOCI technique constitutes important groundwork for in vivo precision endocrine surgery.Level of Evidence: 4 Laryngoscope, 131:2391–2397, 2021
- 19 February 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11213, 1121309
Design and validation of an intraoperative autofluorescence lifetime imaging device
As we know, fluorescence lifetime imaging has demonstrated the ability to accurately detect materials and tissue constituents1–3. Current fluorescence lifetime systems rely on accurate temporal sampling to capture the tails of the decaying emission. These data are often fit to an exponential decay model3,4. Although these methodologies are powerful tools but they are often implemented as point measurement systems and require significant postprocessing to compute decay times or coefficients5–8. In some applications these factors can hinder clinical translation. Based on these observations, our group has developed algorithms and built simple, fast, and wide field imaging system9,10. This method uses a gated charge-coupled device (CCD) and a liquid light cable guided LED to compare the decay-time image intensity vs excited state image intensity, thus generating a spatially resolved maps of relative differences in autofluorescence decay of tissue constituents. This approach ensures very fast updating speed (< 2 sec per frame), big field of view (20 mm x 20 mm), excellent depth of field (up to 6 mm) for surface curvature of interested target at reasonable working distance (~50 mm). This innovative imaging system has a temporal resolution of 0.16 nanosecond, spatial resolution of 70 μm and has proved the capability to differentiate visibly similar tissue types, which has been validated with both fluorescent dyes and ex vivo human tissue samples in comparison to commercially available FLIM microscope. This work establishes a foundation to confirm the utility of our upgraded DOCI system for intraoperative tissue differentiating/imaging. Validation with a larger number of samples is currently ongoing.
- 19 February 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11213, 1121309
Design and validation of an intraoperative autofluorescence lifetime imaging device
As we know, fluorescence lifetime imaging has demonstrated the ability to accurately detect materials and tissue constituents1–3. Current fluorescence lifetime systems rely on accurate temporal sampling to capture the tails of the decaying emission. These data are often fit to an exponential decay model3,4. Although these methodologies are powerful tools but they are often implemented as point measurement systems and require significant postprocessing to compute decay times or coefficients5–8. In some applications these factors can hinder clinical translation. Based on these observations, our group has developed algorithms and built simple, fast, and wide field imaging system9,10. This method uses a gated charge-coupled device (CCD) and a liquid light cable guided LED to compare the decay-time image intensity vs excited state image intensity, thus generating a spatially resolved maps of relative differences in autofluorescence decay of tissue constituents. This approach ensures very fast updating speed (< 2 sec per frame), big field of view (20 mm x 20 mm), excellent depth of field (up to 6 mm) for surface curvature of interested target at reasonable working distance (~50 mm). This innovative imaging system has a temporal resolution of 0.16 nanosecond, spatial resolution of 70 μm and has proved the capability to differentiate visibly similar tissue types, which has been validated with both fluorescent dyes and ex vivo human tissue samples in comparison to commercially available FLIM microscope. This work establishes a foundation to confirm the utility of our upgraded DOCI system for intraoperative tissue differentiating/imaging. Validation with a larger number of samples is currently ongoing.
- 29 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 37-38
Cryptographie coprocessor design for IoT sensor nodes
Together with the popularity of internet of things (IoT), the information security in IoT is becoming an urgent issue. In this paper, a cryptographic coprocessor is designed to provide security for IoT sensor nodes. This design incorporates the application-specific instruction set to support popular cryptography algorithms like advanced encryption standard (AES) and elliptic curve cryptography (ECC). The tailored instruction provides good flexibility, high energy efficiency and low latency. Local instruction and data ram is integrated into our coprocessor to reduce the instruction transfer between embedded processor and the coprocessor. Our work was synthesized under TSMC 65 nm technology. The measurement results show that our design consumes 32.7 uJ for each ECC point multiplication and 3 nJ for each AES encryption and decryption when working at 10 MHz.
- 29 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 37-38
Cryptographie coprocessor design for IoT sensor nodes
Together with the popularity of internet of things (IoT), the information security in IoT is becoming an urgent issue. In this paper, a cryptographic coprocessor is designed to provide security for IoT sensor nodes. This design incorporates the application-specific instruction set to support popular cryptography algorithms like advanced encryption standard (AES) and elliptic curve cryptography (ECC). The tailored instruction provides good flexibility, high energy efficiency and low latency. Local instruction and data ram is integrated into our coprocessor to reduce the instruction transfer between embedded processor and the coprocessor. Our work was synthesized under TSMC 65 nm technology. The measurement results show that our design consumes 32.7 uJ for each ECC point multiplication and 3 nJ for each AES encryption and decryption when working at 10 MHz.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 48, 613-615
A flexible low-power machine learning accelerator for healthcare applications
A flexible machine learning accelerator with low power consumption is presented in this paper. Linear classifier, naïve Bayes (NB) classifier and support vector machine (SVM) classifier with three kernel functions (linear, polynomial and radial basis function (RBF)) are realized in this design using the same architecture. A modified coordinate rotation digital computer (CORDIC) unit with expanded convergence range is employed to calculate exponential functions. The supply voltage is decreased to help reduce the power consumption. Re-characterized libraries for TSMC 65 nm LP technology under near-threshold supply voltages are generated for the implementation of the proposed accelerator. At the supply voltage of 0.6 V and the clock frequency of 10 MHz, the accelerator consumes 0.26 μJ for each classification using SVM with RBF function. Using linear classifier, the power consumption is further reduced to 0.41 nJ per classification.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 48, 613-615
A flexible low-power machine learning accelerator for healthcare applications
A flexible machine learning accelerator with low power consumption is presented in this paper. Linear classifier, naïve Bayes (NB) classifier and support vector machine (SVM) classifier with three kernel functions (linear, polynomial and radial basis function (RBF)) are realized in this design using the same architecture. A modified coordinate rotation digital computer (CORDIC) unit with expanded convergence range is employed to calculate exponential functions. The supply voltage is decreased to help reduce the power consumption. Re-characterized libraries for TSMC 65 nm LP technology under near-threshold supply voltages are generated for the implementation of the proposed accelerator. At the supply voltage of 0.6 V and the clock frequency of 10 MHz, the accelerator consumes 0.26 μJ for each classification using SVM with RBF function. Using linear classifier, the power consumption is further reduced to 0.41 nJ per classification.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 344-347
A low-cost and energy-efficient EEG processor for continuous seizure detection using wavelet transform and AdaBoost
A 16-channel, low-complexity and energy-efficient electroencephalography (EEG) processor for patient-specific seizure detection is presented. The feature extraction algorithm extracts line length features from approximation coefficients from a low-overhead 2-level lifting-based discrete wavelet transform (LWT). Low computational feature vector construction is performed by the concatenation of features extracted from contiguous epochs. A low-complexity binary Adaboost classifier using decision trees is employed in the classification stage. Word length reduction for parameters of the classifier is carried out to make a trade-off between the classification performance and hardware cost. Experimental results demonstrate that our detection algorithm has an average sensitivity, average false alarm rate and latency of 93.8%, 0.16 false alarms/hour and 1 s, respectively. The post-layout simulation in TSMC 65 nm CMOS shows that the proposed processor consumes 0.39 μJ/classification, which is equivalent to 0.006 nJ per input bit.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 344-347
A low-cost and energy-efficient EEG processor for continuous seizure detection using wavelet transform and AdaBoost
A 16-channel, low-complexity and energy-efficient electroencephalography (EEG) processor for patient-specific seizure detection is presented. The feature extraction algorithm extracts line length features from approximation coefficients from a low-overhead 2-level lifting-based discrete wavelet transform (LWT). Low computational feature vector construction is performed by the concatenation of features extracted from contiguous epochs. A low-complexity binary Adaboost classifier using decision trees is employed in the classification stage. Word length reduction for parameters of the classifier is carried out to make a trade-off between the classification performance and hardware cost. Experimental results demonstrate that our detection algorithm has an average sensitivity, average false alarm rate and latency of 93.8%, 0.16 false alarms/hour and 1 s, respectively. The post-layout simulation in TSMC 65 nm CMOS shows that the proposed processor consumes 0.39 μJ/classification, which is equivalent to 0.006 nJ per input bit.
- 3 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 63 (10) , 984-988
An Area-Efficient Error-Resilient Ultralow-Power Subthreshold ECG Processor
Aiming at electrocardiogram (ECG) monitoring systems for wearable and implantable health-care applications, an ultralow-power and low-cost wavelet-based ECG processor is presented in this brief. This processor can work at subthreshold voltage and further save energy by using voltage overscaling (VOS) and algorithmic noise tolerance (ANT). As to the ANT mechanism, we propose a weighted-average-bilateral-estimation predictor and a two-stage architecture with heterogeneous error detection schemes, which enhance the error resiliency of the ECG processor under VOS and improve its robustness against voltage variations within the subthreshold region. Moreover, we intend to meet the strict area constraint of wearable devices, minimizing the hardware cost of the ECG processor and ANT module by using several area-reduction techniques. A test chip of the proposed processor is fabricated under Taiwan Semiconductor Manufacturing Company Limited (TSMC) 65-nm low power (LP) CMOS technology. Measurement results show that this subthreshold processor consumes 2.28 pJ/cycle at (410 mV, 49.8 kHz), and the proposed ANT scheme can result in only 5% area overhead while leading to 7% power saving by tolerating 17% error rate.
- 3 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 63 (10) , 984-988
An Area-Efficient Error-Resilient Ultralow-Power Subthreshold ECG Processor
Aiming at electrocardiogram (ECG) monitoring systems for wearable and implantable health-care applications, an ultralow-power and low-cost wavelet-based ECG processor is presented in this brief. This processor can work at subthreshold voltage and further save energy by using voltage overscaling (VOS) and algorithmic noise tolerance (ANT). As to the ANT mechanism, we propose a weighted-average-bilateral-estimation predictor and a two-stage architecture with heterogeneous error detection schemes, which enhance the error resiliency of the ECG processor under VOS and improve its robustness against voltage variations within the subthreshold region. Moreover, we intend to meet the strict area constraint of wearable devices, minimizing the hardware cost of the ECG processor and ANT module by using several area-reduction techniques. A test chip of the proposed processor is fabricated under Taiwan Semiconductor Manufacturing Company Limited (TSMC) 65-nm low power (LP) CMOS technology. Measurement results show that this subthreshold processor consumes 2.28 pJ/cycle at (410 mV, 49.8 kHz), and the proposed ANT scheme can result in only 5% area overhead while leading to 7% power saving by tolerating 17% error rate.
- 7 November 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 62 (2) , 119-123
An Energy-Efficient Design for ECG Recording and R-Peak Detection Based on Wavelet Transform
Long-term monitoring of electrocardiogram (ECG) requires a portable inspection system that can offer both high energy efficiency and good signal quality. To manage challenges caused by this requirement, this brief presents an ASIC design for both ECG recording and R-peak detection. By supporting data compression and using a dual-ping-pong-memory architecture, this design leads to a large reduction in the whole system energy. To reduce the hardware cost, the techniques of coefficients truncation and resource sharing are adopted. Importantly, parameters optimization and periodic extension are employed to improve quality of the reconstructed signal under high compress ratio (CR). Experimental results based on MIT-BIH database show that the proposed design obtains a high CR of 10.3 with a percentage root-mean-square difference of 0.64% under recording mode, and it achieves an R-peak detection sensitivity of 99.72% as well as a positive prediction of 99.49% with 13.68× data reduction. This design has been fabricated under TSMC 65-nm CMOS technology with area cost of 0.41 mm2. Measurement results indicate that the total system energy consumption for processing one segment of signals can be reduced by 5.7× and 2.3× in recording and detection modes, respectively. Compared to a software implementation on the same chip, this ASIC implementation achieves a 41% and 50% reduction in energy consumption per sample under the two modes, respectively.
- 7 November 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 62 (2) , 119-123
An Energy-Efficient Design for ECG Recording and R-Peak Detection Based on Wavelet Transform
Long-term monitoring of electrocardiogram (ECG) requires a portable inspection system that can offer both high energy efficiency and good signal quality. To manage challenges caused by this requirement, this brief presents an ASIC design for both ECG recording and R-peak detection. By supporting data compression and using a dual-ping-pong-memory architecture, this design leads to a large reduction in the whole system energy. To reduce the hardware cost, the techniques of coefficients truncation and resource sharing are adopted. Importantly, parameters optimization and periodic extension are employed to improve quality of the reconstructed signal under high compress ratio (CR). Experimental results based on MIT-BIH database show that the proposed design obtains a high CR of 10.3 with a percentage root-mean-square difference of 0.64% under recording mode, and it achieves an R-peak detection sensitivity of 99.72% as well as a positive prediction of 99.49% with 13.68× data reduction. This design has been fabricated under TSMC 65-nm CMOS technology with area cost of 0.41 mm2. Measurement results indicate that the total system energy consumption for processing one segment of signals can be reduced by 5.7× and 2.3× in recording and detection modes, respectively. Compared to a software implementation on the same chip, this ASIC implementation achieves a 41% and 50% reduction in energy consumption per sample under the two modes, respectively.