Zelin Hong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zelin Hong has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Xiangrong Chen
College of Electrical Engineering, Zhejiang University, Hangzhou 310027, China
11 shared publications - Ashish Paramane
Department of Electrical Engineering, National Institute of Technology Silchar, Silchar, India
8 shared publications - Muhammad Awais
Ningbo Orient Wires and Cables Company Ltd
6 shared publications - Fan-Bo Meng
Shandong University
5 shared publications Hao Li
Department of Chemistry, Zhejiang University, Hangzhou, China
5 shared publicationsHanshan Zhu
College of Electrical Engineering Zhejiang University Hangzhou China
4 shared publications
Latest Publications
- 23 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (3) , 1760-1767
Insulation Deterioration of Cables as the Downlead for Unibody Composite Pylons Under Lightning Dielectric Barrier Discharge
Cables are suitable as downleads of a composite pylon to provide the ground potential for the shielding wires. However, the impact of lightning-induced plasma on the cross-linked polyethylene (XLPE) layer remains unclear when lightning current passes through the cable downlead. To explore the deterioration mechanism of the cable layer under lightning striking, the XLPE samples are treated with high-frequency plasma for different durations. Subsequently, surface morphology and molecular bonds are characterized, and electrical properties such as dielectric spectroscopy, surface potential decay, trap density, conductivity, and breakdown strength are evaluated. Additionally, a 2D axisymmetric model of the pylon is developed to analyze the electric field distribution using the finite element method. The findings demonstrate that thermo-oxidative induced by high-frequency DBD breaks the XLPE chains, resulting in increased dielectric constant and conductivity, shallower traps, and reduced breakdown strength. Moreover, high-frequency DBD not only deteriorates the downlead cable’s insulation properties but also deforms the material and roughens the surface, consequently amplifying the electric field distortion at the cable-air interface and lowering the partial discharge inception voltage on the cable surface. This study elucidates the degradation mechanism of downlead cables under lightning plasma and offers insights into selecting appropriate cable insulation materials.
- 23 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (3) , 1760-1767
Insulation Deterioration of Cables as the Downlead for Unibody Composite Pylons Under Lightning Dielectric Barrier Discharge
Cables are suitable as downleads of a composite pylon to provide the ground potential for the shielding wires. However, the impact of lightning-induced plasma on the cross-linked polyethylene (XLPE) layer remains unclear when lightning current passes through the cable downlead. To explore the deterioration mechanism of the cable layer under lightning striking, the XLPE samples are treated with high-frequency plasma for different durations. Subsequently, surface morphology and molecular bonds are characterized, and electrical properties such as dielectric spectroscopy, surface potential decay, trap density, conductivity, and breakdown strength are evaluated. Additionally, a 2D axisymmetric model of the pylon is developed to analyze the electric field distribution using the finite element method. The findings demonstrate that thermo-oxidative induced by high-frequency DBD breaks the XLPE chains, resulting in increased dielectric constant and conductivity, shallower traps, and reduced breakdown strength. Moreover, high-frequency DBD not only deteriorates the downlead cable’s insulation properties but also deforms the material and roughens the surface, consequently amplifying the electric field distortion at the cable-air interface and lowering the partial discharge inception voltage on the cable surface. This study elucidates the degradation mechanism of downlead cables under lightning plasma and offers insights into selecting appropriate cable insulation materials.
- 15 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (5) , 2568-2576
Simultaneous Effect of Thermal Aging and Phase Separation on Insulation Properties of 500-kV DC XLPE Blends With Voltage Stabilizers
Thermal aging degrades the insulating layer and shortens the service life of the power cable. In this paper, pure XLPE and four XLPE/voltage stabilizer samples were prepared using 500 kV DC XLPE raw pellets and aged at 135°C for 168 h. Various mechanical and electrical tests were performed to characterize the insulation properties of the samples. The results show that after aging, the mechanical and breakdown strengths of all the samples decrease, the conductivity increases, and the space charge accumulation increases. Besides, the aging process also makes the modification effect of the voltage stabilizers on the XLPE no longer obvious. The trap characteristics indicate that the deep energy level traps cause space charge accumulation and electric field distortion, which decreases the insulation performance of all the samples. The molecular dynamic simulation illustrates that the phase separation of the XLPE and the voltage stabilizers leads to the uneven dispersion of the voltage stabilizers, which will form the weak point of insulation and lead to the failure of the voltage stabilizers.
- 15 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (5) , 2568-2576
Simultaneous Effect of Thermal Aging and Phase Separation on Insulation Properties of 500-kV DC XLPE Blends With Voltage Stabilizers
Thermal aging degrades the insulating layer and shortens the service life of the power cable. In this paper, pure XLPE and four XLPE/voltage stabilizer samples were prepared using 500 kV DC XLPE raw pellets and aged at 135°C for 168 h. Various mechanical and electrical tests were performed to characterize the insulation properties of the samples. The results show that after aging, the mechanical and breakdown strengths of all the samples decrease, the conductivity increases, and the space charge accumulation increases. Besides, the aging process also makes the modification effect of the voltage stabilizers on the XLPE no longer obvious. The trap characteristics indicate that the deep energy level traps cause space charge accumulation and electric field distortion, which decreases the insulation performance of all the samples. The molecular dynamic simulation illustrates that the phase separation of the XLPE and the voltage stabilizers leads to the uneven dispersion of the voltage stabilizers, which will form the weak point of insulation and lead to the failure of the voltage stabilizers.
- 28 August 2023
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 140 (44)
Insulation properties enhancement of crosslinked polyethylene by grafting electron‐buffering voltage stabilizers
Grafting a voltage stabilizer on molecular chains of cross‐linked polyethylene (XLPE) can effectively improve the materials' insulation properties. Four different samples (XLPE, XLPE grafted with the voltage stabilizer, low‐density polyethylene (LDPE) blended with the voltage stabilizer, and LDPE grafted with the voltage stabilizer) are prepared in this paper. Several physicochemical and dielectric tests are performed to investigate the properties of the samples. The results demonstrate that the m‐aminobenzoic acid is successfully grafted onto the XLPE molecular chain. Moreover, the crosslinking and grafting processes are equally important for enhancing the materials' performance of the XLPE. In addition, the grafted voltage stabilizer negligibly affects the gel content and thermal properties of XLPE. However, it increases the crystallinity but decreases the lamella thickness. Moreover, the XLPE grafted with a voltage stabilizer has lower direct current (DC) electrical conductivity, less aggregation of space charge, and higher DC breakdown strength. The trap distribution results indicate that the voltage stabilizer introduces shallow traps in the sample and the quantum chemical calculations describe that the material bandgap is decreased. Thus, the high‐energy charge carriers are buffered by the newly‐introduced traps and the functional groups, leading to the enhanced material properties of the XLPE.
- 28 August 2023
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 140 (44)
Insulation properties enhancement of crosslinked polyethylene by grafting electron‐buffering voltage stabilizers
Grafting a voltage stabilizer on molecular chains of cross‐linked polyethylene (XLPE) can effectively improve the materials' insulation properties. Four different samples (XLPE, XLPE grafted with the voltage stabilizer, low‐density polyethylene (LDPE) blended with the voltage stabilizer, and LDPE grafted with the voltage stabilizer) are prepared in this paper. Several physicochemical and dielectric tests are performed to investigate the properties of the samples. The results demonstrate that the m‐aminobenzoic acid is successfully grafted onto the XLPE molecular chain. Moreover, the crosslinking and grafting processes are equally important for enhancing the materials' performance of the XLPE. In addition, the grafted voltage stabilizer negligibly affects the gel content and thermal properties of XLPE. However, it increases the crystallinity but decreases the lamella thickness. Moreover, the XLPE grafted with a voltage stabilizer has lower direct current (DC) electrical conductivity, less aggregation of space charge, and higher DC breakdown strength. The trap distribution results indicate that the voltage stabilizer introduces shallow traps in the sample and the quantum chemical calculations describe that the material bandgap is decreased. Thus, the high‐energy charge carriers are buffered by the newly‐introduced traps and the functional groups, leading to the enhanced material properties of the XLPE.
- 14 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
Characterization and Identification of Electrical Tree Growth Stages Inside High-Voltage Cable Insulation
Formation of micro-cavities takes place inside high-voltage cross-linked polyethylene (XLPE) cable insulation due to severe electrical and thermal aging, which further act as sources of void discharges and lead to the development of dendritic carbonyl channels, commonly referred to as electrical trees. Accompanied by intermittent partial discharge (PD) activities, the electrical tree growth bridges the entire insulation over time and results in insulation breakdown, which exposes the cable to fatal safety incidents. Therefore, accurately identifying various stages of electrical tree growths is crucial to prevent such safety instances as well as ensure reliable and extended operation of the XLPE cable. To this end, the present study proposes an automated electrical tree growth monitoring scheme employing a customized 19-layer residual neural network (ResNet) model. For this purpose, microscopic images of different tree growth stages inside XLPE insulation samples were acquired at different temperatures (30, 50, and 70 °C) and augmented using a deep convolutional generative adversarial network (DCGAN). Further, using fractal dimension ( df ) of the tree structures, different electrical tree propagation levels were characterized. Finally, different tree growth stages were identified using the proposed 19-layer ResNet model. This approach yielded satisfactorily high recognition accuracies irrespective of varying temperatures, engaging a significantly reduced computational time compared to classical convolutional neural network (CNN) models. This infers its potential application for automated health monitoring of XLPE cable.
- 14 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
Characterization and Identification of Electrical Tree Growth Stages Inside High-Voltage Cable Insulation
Formation of micro-cavities takes place inside high-voltage cross-linked polyethylene (XLPE) cable insulation due to severe electrical and thermal aging, which further act as sources of void discharges and lead to the development of dendritic carbonyl channels, commonly referred to as electrical trees. Accompanied by intermittent partial discharge (PD) activities, the electrical tree growth bridges the entire insulation over time and results in insulation breakdown, which exposes the cable to fatal safety incidents. Therefore, accurately identifying various stages of electrical tree growths is crucial to prevent such safety instances as well as ensure reliable and extended operation of the XLPE cable. To this end, the present study proposes an automated electrical tree growth monitoring scheme employing a customized 19-layer residual neural network (ResNet) model. For this purpose, microscopic images of different tree growth stages inside XLPE insulation samples were acquired at different temperatures (30, 50, and 70 °C) and augmented using a deep convolutional generative adversarial network (DCGAN). Further, using fractal dimension ( df ) of the tree structures, different electrical tree propagation levels were characterized. Finally, different tree growth stages were identified using the proposed 19-layer ResNet model. This approach yielded satisfactorily high recognition accuracies irrespective of varying temperatures, engaging a significantly reduced computational time compared to classical convolutional neural network (CNN) models. This infers its potential application for automated health monitoring of XLPE cable.
- 8 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 30 (1) , 255-262
Optimal Content Selection of Voltage Stabilizers Using TOPSIS Method to Achieve Enhanced Material Properties for HVDC Cable Insulation Applications
Three different contents (1, 3, and 5 wt%) of 4-n-propylbenzoic acid as the voltage stabilizer are added to cross-linked polyethylene (XLPE), whereas electrical, mechanical, and thermal properties of XLPE/stabilizer blends are measured. The obtained results show that the voltage stabilizer addition facilitates a reduction in accumulated space charges and conduction current and improves the life exponent and thermal conductivity of the XLPE but negatively affects the degree of cross-linking. The optimal content of the voltage stabilizer to attain the balanced overall properties is selected by the technique for order of preference by similarity to ideal solution (TOPSIS) method. The electric field distortion rate, conduction current, and temperature sensitivity of electrical conductivity under 40 kV/mm, dc breakdown strength, thermal conductivity, gel content, elongation at break, tensile strength, crystallinity, and temperature at a maximum decomposition rate of the samples are selected as evaluation indices for the TOPSIS method, which yields the 1 wt% of 4-n-propylbenzoic acid as the optimal content. The calculated life exponent is maximum for the XLPE-1, suggesting that the high voltage direct current (HVDC) cable having XLPE insulation with the optimal content of the voltage stabilizer will have a longer service life.
- 8 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 30 (1) , 255-262
Optimal Content Selection of Voltage Stabilizers Using TOPSIS Method to Achieve Enhanced Material Properties for HVDC Cable Insulation Applications
Three different contents (1, 3, and 5 wt%) of 4-n-propylbenzoic acid as the voltage stabilizer are added to cross-linked polyethylene (XLPE), whereas electrical, mechanical, and thermal properties of XLPE/stabilizer blends are measured. The obtained results show that the voltage stabilizer addition facilitates a reduction in accumulated space charges and conduction current and improves the life exponent and thermal conductivity of the XLPE but negatively affects the degree of cross-linking. The optimal content of the voltage stabilizer to attain the balanced overall properties is selected by the technique for order of preference by similarity to ideal solution (TOPSIS) method. The electric field distortion rate, conduction current, and temperature sensitivity of electrical conductivity under 40 kV/mm, dc breakdown strength, thermal conductivity, gel content, elongation at break, tensile strength, crystallinity, and temperature at a maximum decomposition rate of the samples are selected as evaluation indices for the TOPSIS method, which yields the 1 wt% of 4-n-propylbenzoic acid as the optimal content. The calculated life exponent is maximum for the XLPE-1, suggesting that the high voltage direct current (HVDC) cable having XLPE insulation with the optimal content of the voltage stabilizer will have a longer service life.
- 1 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 30 (1) , 271-278
Insulation Properties and Interfacial Quantum Chemical Analysis of Cross-Linked Polyethylene Under Different Degassing Time for HVDC Cable Factory Joint Applications
Degassing treatment is critical to remove cross-linking by-products in cross-linked polyethylene (XLPE) cable factory joints and prevent early insulation deterioration. In this article, 500-kV high-voltage direct-current (HVDC) cable factory joint samples were prepared, and the physicochemical and temperature-dependent electrical properties of the samples under different degassing times were investigated. The results show that prolonged degassing treatment increases the crystallinity and reduces the tensile properties of the XLPE samples. The samples without degassing have visible micropores near the interface, and these micropores can be eliminated after a longer degassing time. In addition, degassing treatment can reduce the current density, increase the threshold field strength, and enhance the breakdown strength of the samples. A significant negative charge accumulation appears at the interface of the sample without degassing, which dramatically distorts the electric field. Long-term degassing treatment can improve this phenomenon, and the accumulated charge at the interface at elevated temperatures is significantly reduced. Furthermore, a model of the molecular chain microstructure at the interface before and after degassing is proposed. The molecular chain’s energy band structure and electron cloud distribution at the interface are analyzed based on quantum chemical calculation. It is found that cable makers can improve the insulation properties of cable factory joints by appropriately extending the degassing time to avoid interface deterioration.
- 1 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 30 (1) , 271-278
Insulation Properties and Interfacial Quantum Chemical Analysis of Cross-Linked Polyethylene Under Different Degassing Time for HVDC Cable Factory Joint Applications
Degassing treatment is critical to remove cross-linking by-products in cross-linked polyethylene (XLPE) cable factory joints and prevent early insulation deterioration. In this article, 500-kV high-voltage direct-current (HVDC) cable factory joint samples were prepared, and the physicochemical and temperature-dependent electrical properties of the samples under different degassing times were investigated. The results show that prolonged degassing treatment increases the crystallinity and reduces the tensile properties of the XLPE samples. The samples without degassing have visible micropores near the interface, and these micropores can be eliminated after a longer degassing time. In addition, degassing treatment can reduce the current density, increase the threshold field strength, and enhance the breakdown strength of the samples. A significant negative charge accumulation appears at the interface of the sample without degassing, which dramatically distorts the electric field. Long-term degassing treatment can improve this phenomenon, and the accumulated charge at the interface at elevated temperatures is significantly reduced. Furthermore, a model of the molecular chain microstructure at the interface before and after degassing is proposed. The molecular chain’s energy band structure and electron cloud distribution at the interface are analyzed based on quantum chemical calculation. It is found that cable makers can improve the insulation properties of cable factory joints by appropriately extending the degassing time to avoid interface deterioration.
- 4 November 2022
- Published by Elsevier in Materials Today Communications
- Vol. 33, 104845
Ni-doped boron nitride nanotubes as promising gas sensing material for dissolved gases in transformer oil
- 4 November 2022
- Published by Elsevier in Materials Today Communications
- Vol. 33, 104845
Ni-doped boron nitride nanotubes as promising gas sensing material for dissolved gases in transformer oil
- 28 October 2022
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 140 (1)
Influence of dielectric barrier effect and thermally‐conductive network on thermal and electrical properties of epoxy under different frequencies and temperatures
Epoxy resin (EPR) insulations play a vital role in the insulation of modern power electronic equipment owing to their excellent dielectric properties. However, due to the high‐power density and miniaturization of power equipment which causes high heat fluxes under high voltage and high‐frequency stresses, EPR with good thermal and insulation properties is urgently needed. In this study, the polydopamine functionalized micro‐BN and core‐shell nano TiO2–SiO2 particles are dispersed in EPR to simultaneously improve thermal and dielectric insulation properties. It is revealed that the addition of micro‐nano particles significantly improves the thermal and dielectric performance. Particularly, the high thermal conductivity of micro‐BN and the dielectric barrier effect due to the core‐shell structure of nano TiO2–SiO2 are the main reasons for improved thermal and dielectric insulation performance, respectively. The EPR composite containing 3 wt% of micro‐BN and 1 wt% of nano TiO2–SiO2 exhibits the optimal performance with 0.49 W/mK thermal conductivity and the highest dielectric strength among all the samples, that is, 60.61 kV/mm even at 10 kHz and 90°C. This study found that the crucial factors are the surface encapsulation, weight percent, and homogeneous dispersion of particles in EPR, the dielectric barrier effect, thermal conductivity, and the mismatch between the dielectric constant of EPR and particles. This study proposes the optimal weight percent of suitable micro‐nano particles for EPR to produce suitable composites for high‐frequency and high‐temperature applications.
- 28 October 2022
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 140 (1)
Influence of dielectric barrier effect and thermally‐conductive network on thermal and electrical properties of epoxy under different frequencies and temperatures
Epoxy resin (EPR) insulations play a vital role in the insulation of modern power electronic equipment owing to their excellent dielectric properties. However, due to the high‐power density and miniaturization of power equipment which causes high heat fluxes under high voltage and high‐frequency stresses, EPR with good thermal and insulation properties is urgently needed. In this study, the polydopamine functionalized micro‐BN and core‐shell nano TiO2–SiO2 particles are dispersed in EPR to simultaneously improve thermal and dielectric insulation properties. It is revealed that the addition of micro‐nano particles significantly improves the thermal and dielectric performance. Particularly, the high thermal conductivity of micro‐BN and the dielectric barrier effect due to the core‐shell structure of nano TiO2–SiO2 are the main reasons for improved thermal and dielectric insulation performance, respectively. The EPR composite containing 3 wt% of micro‐BN and 1 wt% of nano TiO2–SiO2 exhibits the optimal performance with 0.49 W/mK thermal conductivity and the highest dielectric strength among all the samples, that is, 60.61 kV/mm even at 10 kHz and 90°C. This study found that the crucial factors are the surface encapsulation, weight percent, and homogeneous dispersion of particles in EPR, the dielectric barrier effect, thermal conductivity, and the mismatch between the dielectric constant of EPR and particles. This study proposes the optimal weight percent of suitable micro‐nano particles for EPR to produce suitable composites for high‐frequency and high‐temperature applications.
- 24 June 2022
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 139 (33)
Inhibition of electrical trees degradation of crosslinked polyethylene at high temperatures by electron‐buffering voltage stabilizers
The effect of adding electron‐buffering voltage stabilizer (1 wt% m‐aminobenzoic acid) on the electrical tree‐induced degradation of cross‐linked polyethylene (XLPE) was studied at high temperatures. The electrical tree inception, growth, and partial discharge characteristics were simultaneously analyzed at 30, 50, and 70°C, respectively. The results showed that the growth rate of electrical tree and partial discharge activity as well as the discharge repetition rate, significantly increased with the temperature for pure XLPE and XLPE stabilizer blend. However, the XLPE stabilizer blend exhibited higher tree inception voltage, lower tree growth rate, and partial discharge activity than pure XLPE. The addition of the voltage stabilizer reduced the carbon layer thickness in the tree channel and offered higher resistance to the electrical tree growth. Surface potential decay demonstrated that the voltage stabilizer addition decreased the trap energy level, but increased the shallow trap density of the XLPE. Quantum chemical calculations showed that the voltage stabilizer enhanced the ability to buffer the high‐energy electrons in the XLPE. A high‐energy electron buffering mechanism was also proposed to explain the effect of voltage stabilizer on the electrical treeing and partial discharge activity in the XLPE at high temperatures.
- 24 June 2022
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 139 (33)
Inhibition of electrical trees degradation of crosslinked polyethylene at high temperatures by electron‐buffering voltage stabilizers
The effect of adding electron‐buffering voltage stabilizer (1 wt% m‐aminobenzoic acid) on the electrical tree‐induced degradation of cross‐linked polyethylene (XLPE) was studied at high temperatures. The electrical tree inception, growth, and partial discharge characteristics were simultaneously analyzed at 30, 50, and 70°C, respectively. The results showed that the growth rate of electrical tree and partial discharge activity as well as the discharge repetition rate, significantly increased with the temperature for pure XLPE and XLPE stabilizer blend. However, the XLPE stabilizer blend exhibited higher tree inception voltage, lower tree growth rate, and partial discharge activity than pure XLPE. The addition of the voltage stabilizer reduced the carbon layer thickness in the tree channel and offered higher resistance to the electrical tree growth. Surface potential decay demonstrated that the voltage stabilizer addition decreased the trap energy level, but increased the shallow trap density of the XLPE. Quantum chemical calculations showed that the voltage stabilizer enhanced the ability to buffer the high‐energy electrons in the XLPE. A high‐energy electron buffering mechanism was also proposed to explain the effect of voltage stabilizer on the electrical treeing and partial discharge activity in the XLPE at high temperatures.
- 17 March 2022
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 139 (23)
Voltage stabilizer and nanofiller in enhancement of insulation properties of cross‐linked polyethylene
This paper investigates the influence of voltage stabilizer and nanofiller addition on the insulation performance of the cross‐linked polyethylene (XLPE). The test samples of XLPE/stabilizer blends consisting of 1 wt% m‐aminobenzoic acid, XLPE nanocomposites consisting of 0.5 wt% nano MgO and XLPE hybrid composite consisting of both voltage stabilizer and nanofillers were prepared. Various physicochemical and electrical properties were measured to analyze the performance of prepared samples. The obtained results show that the addition of nanofillers deteriorates the electrical insulation performance of the XLPE. On the other hand, the voltage stabilizer addition proves to be suitable for enhancing the electrical insulation performance of the XLPE. Meanwhile, the hybrid XLPE composites have shown medium behavior. The voltage stabilizer addition reduces, but the nanofillers increase the space charge density inside the XLPE compared to pure XLPE. It is also found that the dispersion of the voltage stabilizer in the material is uniform, whereas the nanofillers are aggregated. Furthermore, both additives slightly improve the thermal stability of the XLPE. The trap level theory based on quantum chemical calculation is proposed to explain the influence mechanism of the additives on the XLPE.
- 17 March 2022
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 139 (23)
Voltage stabilizer and nanofiller in enhancement of insulation properties of cross‐linked polyethylene
This paper investigates the influence of voltage stabilizer and nanofiller addition on the insulation performance of the cross‐linked polyethylene (XLPE). The test samples of XLPE/stabilizer blends consisting of 1 wt% m‐aminobenzoic acid, XLPE nanocomposites consisting of 0.5 wt% nano MgO and XLPE hybrid composite consisting of both voltage stabilizer and nanofillers were prepared. Various physicochemical and electrical properties were measured to analyze the performance of prepared samples. The obtained results show that the addition of nanofillers deteriorates the electrical insulation performance of the XLPE. On the other hand, the voltage stabilizer addition proves to be suitable for enhancing the electrical insulation performance of the XLPE. Meanwhile, the hybrid XLPE composites have shown medium behavior. The voltage stabilizer addition reduces, but the nanofillers increase the space charge density inside the XLPE compared to pure XLPE. It is also found that the dispersion of the voltage stabilizer in the material is uniform, whereas the nanofillers are aggregated. Furthermore, both additives slightly improve the thermal stability of the XLPE. The trap level theory based on quantum chemical calculation is proposed to explain the influence mechanism of the additives on the XLPE.