Tobias Röddiger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tobias Röddiger has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
- Michael Beigl
Karlsruhe Institute of Technology, Karlsruhe, Germany
31 shared publications - Michael Küttner
Karlsruhe Institute of Technology, Karlsruhe, Germany
8 shared publications - Philipp Lepold
Karlsruhe Institute of Technology, Karlsruhe, Germany
8 shared publications - Tobias King
Karlsruhe Institute of Technology, Karlsruhe, Germany
7 shared publications - Jonas Hummel
Karlsruhe Institute of Technology, Karlsruhe, Germany
5 shared publications - Michael Thomas Knierim
Institute for Information Systems (WIN), Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany and School of Computer Science, University of Nottingham, Nottingham, United Kingdom
5 shared publications
Latest Publications
- Open Access
- 10 October 2026
- Published by Association for Computing Machinery (ACM)
- p. 15-21
BayaHAR: Lightweight Bayesian Few-Shot User Adaptation for On-Device Personalized Human Activity Recognition
- 10 October 2026
- Published by Association for Computing Machinery (ACM)
- p. 15-21
Open AccessBayaHAR: Lightweight Bayesian Few-Shot User Adaptation for On-Device Personalized Human Activity Recognition
- Open Access
- 10 October 2026
- Published by Association for Computing Machinery (ACM)
- p. 127-133
Reassessing the Feasibility of PPG-Based Non-Invasive Blood Glucose Level Estimation
- 10 October 2026
- Published by Association for Computing Machinery (ACM)
- p. 127-133
Open AccessReassessing the Feasibility of PPG-Based Non-Invasive Blood Glucose Level Estimation
- Open Access
- 10 October 2026
- Published by Association for Computing Machinery (ACM)
- p. 71-77
Finger-to-Ear ECG: Systematic Evaluation of an Earbud-Based Cardiac Monitoring Approach
- 10 October 2026
- Published by Association for Computing Machinery (ACM)
- p. 71-77
Open AccessFinger-to-Ear ECG: Systematic Evaluation of an Earbud-Based Cardiac Monitoring Approach
- Open Access
- 30 September 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10 (3) , 1-25
ImpactEar: Cross Activity Ground Reaction Force Estimation using Earable IMUs
Ground Reaction Forces (GRFs) are the forces exerted between the foot and the ground during movement. They are key biomechanical indicators for gait monitoring, injury recovery tracking, and sporting performance. Traditional force plates provide gold-standard accuracy but are expensive and confined to laboratories, while leg- or foot-mounted devices require specialised hardware and sacrifice user comfort. Recent work utilising commodity devices such as smartwatches and earphones offer greater accessibility, yet wrist sensors suffer from arm-swing artifacts and existing earable studies remain activity-specific, limited to either walking or running (and never both) as GRF patterns differ drastically across locomotion types. In this paper, we propose ImpactEar, the first system to estimate complete GRF curves across multiple activities using only a pair of earable inertial measurement units (IMUs). Our core insight is to treat the head as a proxy for the body's center of mass and leverage bilateral earable IMUs to capture both translational and rotational dynamics. Combined with temporal context modeling, this enables a cross-activity mapping from head motion to GRF curves with a single model. ImpactEar employs a lightweight encoder-decoder network that reconstructs left-right GRF profiles across walking, running, and jumping in real time. The evaluation on 30 participants shows that ImpactEar achieves 8.6% normalized root mean square error (NRMSE) and 9.5 ms latency on a mobile phone streaming earable IMU data, outperforming state-of-the-art single-activity baselines and remaining robust under practical conditions, such as reduced sampling rates, single earbuds, different ground surfaces, music playback and head and facial motions. We further demonstrate the power of a cross activity model over a range of different downstream applications including gait asymmetry analysis, jump power assessment, and ballet motion evaluation. Finally, we release ImpactEarDS, the first public earable-GRF dataset with synchronised IMU and force-plate ground truth, paving the way for ubiquitous human kinetics and biomechanics research.
- 30 September 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10 (3) , 1-25
Open AccessImpactEar: Cross Activity Ground Reaction Force Estimation using Earable IMUs
Ground Reaction Forces (GRFs) are the forces exerted between the foot and the ground during movement. They are key biomechanical indicators for gait monitoring, injury recovery tracking, and sporting performance. Traditional force plates provide gold-standard accuracy but are expensive and confined to laboratories, while leg- or foot-mounted devices require specialised hardware and sacrifice user comfort. Recent work utilising commodity devices such as smartwatches and earphones offer greater accessibility, yet wrist sensors suffer from arm-swing artifacts and existing earable studies remain activity-specific, limited to either walking or running (and never both) as GRF patterns differ drastically across locomotion types. In this paper, we propose ImpactEar, the first system to estimate complete GRF curves across multiple activities using only a pair of earable inertial measurement units (IMUs). Our core insight is to treat the head as a proxy for the body's center of mass and leverage bilateral earable IMUs to capture both translational and rotational dynamics. Combined with temporal context modeling, this enables a cross-activity mapping from head motion to GRF curves with a single model. ImpactEar employs a lightweight encoder-decoder network that reconstructs left-right GRF profiles across walking, running, and jumping in real time. The evaluation on 30 participants shows that ImpactEar achieves 8.6% normalized root mean square error (NRMSE) and 9.5 ms latency on a mobile phone streaming earable IMU data, outperforming state-of-the-art single-activity baselines and remaining robust under practical conditions, such as reduced sampling rates, single earbuds, different ground surfaces, music playback and head and facial motions. We further demonstrate the power of a cross activity model over a range of different downstream applications including gait asymmetry analysis, jump power assessment, and ballet motion evaluation. Finally, we release ImpactEarDS, the first public earable-GRF dataset with synchronised IMU and force-plate ground truth, paving the way for ubiquitous human kinetics and biomechanics research.
- Open Access
- 15 June 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10 (2) , 1-41
A Survey of Earable Technology: Trends, Tools, and the Road Ahead
Earable devices, wearables positioned in or around the ear, are undergoing a rapid transformation from audio-centric accessories into multifunctional systems for interaction, contextual awareness, and health monitoring. This evolution is driven by commercial trends emphasizing sensor integration and by a surge of academic interest exploring novel sensing capabilities. Building on the foundation established by earlier surveys, this work presents a timely and comprehensive review of earable research published since 2022. We attempt to answer three core questions: (1) how has earable research evolved in recent years, (2) what enabling resources are now available, and (3) what opportunities remain for future exploration. For question (1), we analyze over one hundred recent studies to characterize this shifting research landscape, by identifying emerging sensing principles / applications, and efforts to improve accuracy and reliability over prior works. For question (2), we summarize new public datasets and hardware platforms that can be leveraged to facilitate future earable research. Finally, for question (3), we discuss open challenges and propose future directions for the next phase of earable research.
- 15 June 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10 (2) , 1-41
Open AccessA Survey of Earable Technology: Trends, Tools, and the Road Ahead
Earable devices, wearables positioned in or around the ear, are undergoing a rapid transformation from audio-centric accessories into multifunctional systems for interaction, contextual awareness, and health monitoring. This evolution is driven by commercial trends emphasizing sensor integration and by a surge of academic interest exploring novel sensing capabilities. Building on the foundation established by earlier surveys, this work presents a timely and comprehensive review of earable research published since 2022. We attempt to answer three core questions: (1) how has earable research evolved in recent years, (2) what enabling resources are now available, and (3) what opportunities remain for future exploration. For question (1), we analyze over one hundred recent studies to characterize this shifting research landscape, by identifying emerging sensing principles / applications, and efforts to improve accuracy and reliability over prior works. For question (2), we summarize new public datasets and hardware platforms that can be leveraged to facilitate future earable research. Finally, for question (3), we discuss open challenges and propose future directions for the next phase of earable research.
- Open Access
- 16 March 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10 (1) , 1-41
Affective Wearable Haptic Interventions: A Systematic Literature Review
The rise of haptic technology in wearable devices presents new opportunities for affective interventions, promoting mental well-being with minimal effort and immediate relief in everyday situations. This review analyzes 83 relevant articles from 1098 identified, outlining research trends and key dimensions of intervention design and evaluation. Through thematic and descriptive analysis, the studies are organized by affective goals, haptic modalities, body locations, and contextual mechanisms. Three major affective orientations were identified—valence-arousal, social, and embodied affect—revealing a dominant focus on calming and stress-related interventions. Vibrotactile feedback on wearable-friendly areas such as the wrist and forearm was most common, while thermal, pressure, and stroking-based modalities are emerging. Cross-dimensional mapping shows that haptic modality, body placement, and intervention mechanism jointly shape affective outcomes, emphasizing embodied physiological regulation and interpersonal connection as key pathways for affective modulation, as well as future directions involving multi-user interactions. By synthesizing current findings, this work offers a structured framework to guide the design, implementation, and evaluation of affective wearable haptic interventions across diverse application contexts.
- 16 March 2026
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 10 (1) , 1-41
Open AccessAffective Wearable Haptic Interventions: A Systematic Literature Review
The rise of haptic technology in wearable devices presents new opportunities for affective interventions, promoting mental well-being with minimal effort and immediate relief in everyday situations. This review analyzes 83 relevant articles from 1098 identified, outlining research trends and key dimensions of intervention design and evaluation. Through thematic and descriptive analysis, the studies are organized by affective goals, haptic modalities, body locations, and contextual mechanisms. Three major affective orientations were identified—valence-arousal, social, and embodied affect—revealing a dominant focus on calming and stress-related interventions. Vibrotactile feedback on wearable-friendly areas such as the wrist and forearm was most common, while thermal, pressure, and stroking-based modalities are emerging. Cross-dimensional mapping shows that haptic modality, body placement, and intervention mechanism jointly shape affective outcomes, emphasizing embodied physiological regulation and interpersonal connection as key pathways for affective modulation, as well as future directions involving multi-user interactions. By synthesizing current findings, this work offers a structured framework to guide the design, implementation, and evaluation of affective wearable haptic interventions across diverse application contexts.
- Open Access
EarResp-ANS : Audio-Based On-Device Respiration Rate Estimation on Earphones with Adaptive Noise Suppression
Respiratory rate (RR) is a key vital sign for clinical assessment and mental well-being, yet it is rarely monitored in everyday life due to the lack of unobtrusive sensing technologies. In-ear audio sensing is promising due to its high social acceptance and the amplification of physiological sounds caused by the occlusion effect; however, existing approaches often fail under real-world noise or rely on computationally expensive models. We present EarResp-ANS, the first system enabling fully on-device, real-time RR estimation on commercial earphones. The system employs LMS-based adaptive noise suppression (ANS) to attenuate ambient noise while preserving respiration-related acoustic components, without requiring neural networks or audio streaming, thereby explicitly addressing the energy and privacy constraints of wearable devices. We evaluate EarResp-ANS in a study with 18 participants under realistic acoustic conditions, including music, cafeteria noise, and white noise up to 80 dB SPL. EarResp-ANS achieves robust performance with a global MAE of 0.84 CPM , reduced to 0.47 CPM via automatic outlier rejection, while operating with less than 2% processor load directly on the earphone.
Open AccessEarResp-ANS : Audio-Based On-Device Respiration Rate Estimation on Earphones with Adaptive Noise Suppression
Respiratory rate (RR) is a key vital sign for clinical assessment and mental well-being, yet it is rarely monitored in everyday life due to the lack of unobtrusive sensing technologies. In-ear audio sensing is promising due to its high social acceptance and the amplification of physiological sounds caused by the occlusion effect; however, existing approaches often fail under real-world noise or rely on computationally expensive models. We present EarResp-ANS, the first system enabling fully on-device, real-time RR estimation on commercial earphones. The system employs LMS-based adaptive noise suppression (ANS) to attenuate ambient noise while preserving respiration-related acoustic components, without requiring neural networks or audio streaming, thereby explicitly addressing the energy and privacy constraints of wearable devices. We evaluate EarResp-ANS in a study with 18 participants under realistic acoustic conditions, including music, cafeteria noise, and white noise up to 80 dB SPL. EarResp-ANS achieves robust performance with a global MAE of 0.84 CPM , reduced to 0.47 CPM via automatic outlier rejection, while operating with less than 2% processor load directly on the earphone.
- Open Access
CHOMP: Multimodal Chewing Side Detection with Earphones
Chewing side preference (CSP) has been identified both as a risk factor for temporomandibular disorders (TMD) and behavioral manifestation. Despite TMDs affecting roughly one third of the global population, assessment mainly relies on clinical examinations and self-reports, offering limited insight into everyday jaw function. Continuous CSP monitoring could provide an objective proxy for functional asymmetries. Prior wearable approaches, however, mostly use specialized form factors and demonstrate limited performance. We therefore present CHOMP, the first system for chewing side detection using earphones. Employing OpenEarable 2.0, we collected data from 20 participants with microphones, a bone-conduction microphone, IMU, PPG, and a pressure sensor across eleven foods, five non-chewing activities, and three noise conditions. We apply the Continuous Wavelet Transform to each sensing modality and use the resulting multi-channel scalograms as inputs to CNN-based classifiers. Microphones achieve the strongest single-sensor unit performance, with median F1 scores of 94.5% in leave-one-food-out (LOFO) and 92.6% in leave-one-subject-out (LOSO) cross-validations. Fusing sensing modalities further improves performance to 97.7% for LOFO and 95.4% for LOSO, with additional evaluations under noise interference indicating robust performance. Our results establish earphones as a practical platform for continuous CSP monitoring, enabling clinicians and patients to assess jaw function in everyday life.
Open AccessCHOMP: Multimodal Chewing Side Detection with Earphones
Chewing side preference (CSP) has been identified both as a risk factor for temporomandibular disorders (TMD) and behavioral manifestation. Despite TMDs affecting roughly one third of the global population, assessment mainly relies on clinical examinations and self-reports, offering limited insight into everyday jaw function. Continuous CSP monitoring could provide an objective proxy for functional asymmetries. Prior wearable approaches, however, mostly use specialized form factors and demonstrate limited performance. We therefore present CHOMP, the first system for chewing side detection using earphones. Employing OpenEarable 2.0, we collected data from 20 participants with microphones, a bone-conduction microphone, IMU, PPG, and a pressure sensor across eleven foods, five non-chewing activities, and three noise conditions. We apply the Continuous Wavelet Transform to each sensing modality and use the resulting multi-channel scalograms as inputs to CNN-based classifiers. Microphones achieve the strongest single-sensor unit performance, with median F1 scores of 94.5% in leave-one-food-out (LOFO) and 92.6% in leave-one-subject-out (LOSO) cross-validations. Fusing sensing modalities further improves performance to 97.7% for LOFO and 95.4% for LOSO, with additional evaluations under noise interference indicating robust performance. Our results establish earphones as a practical platform for continuous CSP monitoring, enabling clinicians and patients to assess jaw function in everyday life.
- Open Access
- 2 December 2025
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 9 (4) , 1-22
HearForce: Force Estimation for Manual Toothbrushing with Earables
Excessive tooth brushing force can contribute to oral health issues such as gum recession and bleeding. While some electric toothbrushes offer force feedback, manual toothbrushes remain widely used due to their affordability and accessibility but do not give this sort of information to users. Therefore, they often lack awareness of the force they apply while brushing. In this paper, we introduce HearForce, the first system to estimate tooth brushing force from manual toothbrushing using widely available earbuds. Unlike existing solutions that require significant modifications to toothbrushes, HearForce leverages in-ear microphones on commercial earbuds to capture bone-conducted toothbrushing sound propagating from the oral cavity to the ear canals. Our key insight is that variations in brushing force modulate these toothbrushing sounds due to the friction effect, allowing us to infer force levels through deep learning. However, individual habitual and anatomical differences introduce significant challenges for force estimation. To mitigate this, we propose a self-supervised representation learning network with a cross-attention mechanism to suppress user-dependent variability and a heuristic calibration strategy to adapt the model to different brushing habits. Through extensive evaluation, HearForce demonstrates force estimation capabilities with a Mean Absolute Error (MAE) of 37.3g in user-independent settings, corresponding to 11.4% of the typical force dynamic range. Our study makes the first step in the use of everyday earbuds for manual toothbrushing force monitoring, paving the way for accessible solutions to improve brushing habits for manual toothbrush users globally.
- 2 December 2025
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 9 (4) , 1-22
Open AccessHearForce: Force Estimation for Manual Toothbrushing with Earables
Excessive tooth brushing force can contribute to oral health issues such as gum recession and bleeding. While some electric toothbrushes offer force feedback, manual toothbrushes remain widely used due to their affordability and accessibility but do not give this sort of information to users. Therefore, they often lack awareness of the force they apply while brushing. In this paper, we introduce HearForce, the first system to estimate tooth brushing force from manual toothbrushing using widely available earbuds. Unlike existing solutions that require significant modifications to toothbrushes, HearForce leverages in-ear microphones on commercial earbuds to capture bone-conducted toothbrushing sound propagating from the oral cavity to the ear canals. Our key insight is that variations in brushing force modulate these toothbrushing sounds due to the friction effect, allowing us to infer force levels through deep learning. However, individual habitual and anatomical differences introduce significant challenges for force estimation. To mitigate this, we propose a self-supervised representation learning network with a cross-attention mechanism to suppress user-dependent variability and a heuristic calibration strategy to adapt the model to different brushing habits. Through extensive evaluation, HearForce demonstrates force estimation capabilities with a Mean Absolute Error (MAE) of 37.3g in user-independent settings, corresponding to 11.4% of the typical force dynamic range. Our study makes the first step in the use of everyday earbuds for manual toothbrushing force monitoring, paving the way for accessible solutions to improve brushing habits for manual toothbrush users globally.
- Open Access
- 12 October 2025
- Published by Association for Computing Machinery (ACM)
- p. 841-846
Feasibility of In-Ear Single-Channel ExG for Wearable Sleep Monitoring in Real-World Settings
- 12 October 2025
- Published by Association for Computing Machinery (ACM)
- p. 841-846
Open AccessFeasibility of In-Ear Single-Channel ExG for Wearable Sleep Monitoring in Real-World Settings