Tara M. Urner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tara M. Urner has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Erin M. Buckley
The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology/Emory University, Atlanta, USA
5 shared publications Shasha Bai
Emory University School of Medicine
4 shared publicationsHongting Zhao
Georgia Institute of Technology and Emory University
3 shared publicationsMariam Akbar
Georgia Institute of Technology and Emory University
3 shared publicationsR. Clark Brown
Illexcor Therapeutics
3 shared publicationsRowan O. Brothers
Georgia Institute of Technology and Emory University
3 shared publications
Latest Publications
- 4 February 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (3) , 1152-1162
Reliability of diffuse optical spectroscopies for evaluation of cerebral hemometabolic stress in children with sickle cell anemia
Diffuse optical spectroscopies are promising non-invasive optical techniques that may provide a point-of-care tool to evaluate cerebral hemometabolic stress. This study quantifies the intra- and inter-operator reliability of a battery of cerebral hemometabolic parameters quantified with diffuse correlation spectroscopy (DCS) and frequency-domain near-infrared spectroscopy (FDNIRS) in children with sickle cell anemia. For measures of cerebral blood flow, oxygen extraction fraction, metabolic rate of oxygen, and cerebral blood volume, we found inter-operator concordance correlation coefficients (CCC) ranging from 0.45 to 0.97, intra-operator CCCs ranging from 0.81 to 0.98, and a median coefficient of variation < 16%.
- 4 February 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (3) , 1152-1162
Reliability of diffuse optical spectroscopies for evaluation of cerebral hemometabolic stress in children with sickle cell anemia
Diffuse optical spectroscopies are promising non-invasive optical techniques that may provide a point-of-care tool to evaluate cerebral hemometabolic stress. This study quantifies the intra- and inter-operator reliability of a battery of cerebral hemometabolic parameters quantified with diffuse correlation spectroscopy (DCS) and frequency-domain near-infrared spectroscopy (FDNIRS) in children with sickle cell anemia. For measures of cerebral blood flow, oxygen extraction fraction, metabolic rate of oxygen, and cerebral blood volume, we found inter-operator concordance correlation coefficients (CCC) ranging from 0.45 to 0.97, intra-operator CCCs ranging from 0.81 to 0.98, and a median coefficient of variation < 16%.
- 21 January 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (2) , 872-884
Correlation between diffuse correlation spectroscopy and transcranial Doppler ultrasound in pediatric sickle cell disease
Sickle cell disease causes alterations in cerebral blood flow (CBF) and a high risk of stroke. Monitoring CBF in these patients may provide valuable information about neurovascular compromise. Diffuse correlation spectroscopy (DCS) is a promising approach for non-invasively estimating an index of regional CBF; however, foundational studies are needed to validate DCS against clinical standards for estimating CBF in this clinical population. Here, we demonstrate that DCS significantly correlates with transcranial Doppler ultrasound-measured blood flow velocity in the anterior cerebral artery in 16 children with sickle cell disease (r = 0.82, p < 0.001). Correction for the influence of hematocrit on BFI did not significantly change this correction.
- 21 January 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (2) , 872-884
Correlation between diffuse correlation spectroscopy and transcranial Doppler ultrasound in pediatric sickle cell disease
Sickle cell disease causes alterations in cerebral blood flow (CBF) and a high risk of stroke. Monitoring CBF in these patients may provide valuable information about neurovascular compromise. Diffuse correlation spectroscopy (DCS) is a promising approach for non-invasively estimating an index of regional CBF; however, foundational studies are needed to validate DCS against clinical standards for estimating CBF in this clinical population. Here, we demonstrate that DCS significantly correlates with transcranial Doppler ultrasound-measured blood flow velocity in the anterior cerebral artery in 16 children with sickle cell disease (r = 0.82, p < 0.001). Correction for the influence of hematocrit on BFI did not significantly change this correction.
- 26 September 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (10) , 6052-6062
Stand-alone segmentation of blood flow pulsatility measured with diffuse correlation spectroscopy
We present a stand-alone blood flow index (BFI) pulse segmentation method for diffuse correlation spectroscopy that uses a wavelet-based representation of the BFI signal at the cardiac frequency in place of an exogenous physiological reference. We use this wavelet-based segmentation method to quantify BFI waveform morphology in a cohort of 30 healthy adults. We demonstrate that the waveform morphology features obtained with the wavelet approach strongly agree with those obtained using an exogenous blood pressure reference signal. These results suggest the promise of stand-alone wavelet-based BFI segmentation for quantifying BFI waveform morphological features.
- 26 September 2024
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 15 (10) , 6052-6062
Stand-alone segmentation of blood flow pulsatility measured with diffuse correlation spectroscopy
We present a stand-alone blood flow index (BFI) pulse segmentation method for diffuse correlation spectroscopy that uses a wavelet-based representation of the BFI signal at the cardiac frequency in place of an exogenous physiological reference. We use this wavelet-based segmentation method to quantify BFI waveform morphology in a cohort of 30 healthy adults. We demonstrate that the waveform morphology features obtained with the wavelet approach strongly agree with those obtained using an exogenous blood pressure reference signal. These results suggest the promise of stand-alone wavelet-based BFI segmentation for quantifying BFI waveform morphological features.
- Open Access
- 23 May 2024
- Published by American Society of Hematology in Blood
- Vol. 143 (21) , 2145-2151
The influence of voxelotor on cerebral blood flow and oxygen extraction in pediatric sickle cell disease
Voxelotor is an inhibitor of sickle hemoglobin polymerization that is used to treat sickle cell disease. Although voxelotor has been shown to improve anemia, the clinical benefit on the brain remains to be determined. This study quantified the cerebral hemodynamic effects of voxelotor in children with sickle cell anemia (SCA) using noninvasive diffuse optical spectroscopies. Specifically, frequency-domain near-infrared spectroscopy combined with diffuse correlation spectroscopy were used to noninvasively assess regional oxygen extraction fraction (OEF), cerebral blood volume, and an index of cerebral blood flow (CBFi). Estimates of CBFi were first validated against arterial spin–labeled magnetic resonance imaging (ASL-MRI) in 8 children with SCA aged 8 to 18 years. CBFi was significantly positively correlated with ASL-MRI–measured blood flow (R2 = 0.651; P = .015). Next, a single-center, open-label pilot study was completed in 8 children with SCA aged 4 to 17 years on voxelotor, monitored before treatment initiation and at 4, 8, and 12 weeks (NCT05018728). By 4 weeks, both OEF and CBFi significantly decreased, and these decreases persisted to 12 weeks (both P < .05). Decreases in CBFi were significantly correlated with increases in blood hemoglobin (Hb) concentration (P = .025), whereas the correlation between decreases in OEF and increases in Hb trended toward significance (P = .12). Given that previous work has shown that oxygen extraction and blood flow are elevated in pediatric SCA compared with controls, these results suggest that voxelotor may reduce cerebral hemodynamic impairments. This trial was registered at www.ClinicalTrials.gov as #NCT05018728.
- 23 May 2024
- Published by American Society of Hematology in Blood
- Vol. 143 (21) , 2145-2151
Open AccessThe influence of voxelotor on cerebral blood flow and oxygen extraction in pediatric sickle cell disease
Voxelotor is an inhibitor of sickle hemoglobin polymerization that is used to treat sickle cell disease. Although voxelotor has been shown to improve anemia, the clinical benefit on the brain remains to be determined. This study quantified the cerebral hemodynamic effects of voxelotor in children with sickle cell anemia (SCA) using noninvasive diffuse optical spectroscopies. Specifically, frequency-domain near-infrared spectroscopy combined with diffuse correlation spectroscopy were used to noninvasively assess regional oxygen extraction fraction (OEF), cerebral blood volume, and an index of cerebral blood flow (CBFi). Estimates of CBFi were first validated against arterial spin–labeled magnetic resonance imaging (ASL-MRI) in 8 children with SCA aged 8 to 18 years. CBFi was significantly positively correlated with ASL-MRI–measured blood flow (R2 = 0.651; P = .015). Next, a single-center, open-label pilot study was completed in 8 children with SCA aged 4 to 17 years on voxelotor, monitored before treatment initiation and at 4, 8, and 12 weeks (NCT05018728). By 4 weeks, both OEF and CBFi significantly decreased, and these decreases persisted to 12 weeks (both P < .05). Decreases in CBFi were significantly correlated with increases in blood hemoglobin (Hb) concentration (P = .025), whereas the correlation between decreases in OEF and increases in Hb trended toward significance (P = .12). Given that previous work has shown that oxygen extraction and blood flow are elevated in pediatric SCA compared with controls, these results suggest that voxelotor may reduce cerebral hemodynamic impairments. This trial was registered at www.ClinicalTrials.gov as #NCT05018728.
- 23 June 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (7) , 3635-3653
Normative cerebral microvascular blood flow waveform morphology assessed with diffuse correlation spectroscopy
Microvascular cerebral blood flow exhibits pulsatility at the cardiac frequency that carries valuable information about cerebrovascular health. This study used diffuse correlation spectroscopy to quantify normative features of these waveforms in a cohort of thirty healthy adults. We demonstrate they are sensitive to changes in vascular tone, as indicated by pronounced morphological changes with hypercapnia. Further, we observe significant sex-based differences in waveform morphology, with females exhibiting higher flow, greater area-under-the-curve, and lower pulsatility. Finally, we quantify normative values for cerebral critical closing pressure, i.e., the minimum pressure required to maintain flow in a given vascular region.
- 23 June 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (7) , 3635-3653
Normative cerebral microvascular blood flow waveform morphology assessed with diffuse correlation spectroscopy
Microvascular cerebral blood flow exhibits pulsatility at the cardiac frequency that carries valuable information about cerebrovascular health. This study used diffuse correlation spectroscopy to quantify normative features of these waveforms in a cohort of thirty healthy adults. We demonstrate they are sensitive to changes in vascular tone, as indicated by pronounced morphological changes with hypercapnia. Further, we observe significant sex-based differences in waveform morphology, with females exhibiting higher flow, greater area-under-the-curve, and lower pulsatility. Finally, we quantify normative values for cerebral critical closing pressure, i.e., the minimum pressure required to maintain flow in a given vascular region.
- 5 January 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (2) , 590-607
Three-dimensional light-field microendoscopy with a GRIN lens array
Optical endoscopy has emerged as an indispensable clinical tool for modern minimally invasive surgery. Most systems primarily capture a 2D projection of the 3D surgical field. Currently available 3D endoscopes can restore stereoscopic vision directly by projecting laterally shifted views of the operating field to each eye through 3D glasses. These tools provide surgeons with informative 3D visualizations, but they do not enable quantitative volumetric rendering of tissue. Therefore, advanced tools are desired to quantify tissue tomography for high precision microsurgery or medical robotics. Light-field imaging suggests itself as a promising solution to the challenge. The approach can capture both the spatial and angular information of optical signals, permitting the computational synthesis of the 3D volume of an object. In this work, we present GRIN lens array microendoscopy (GLAM), a single-shot, full-color, and quantitative 3D microendoscopy system. GLAM contains integrated fiber optics for illumination and a GRIN lens array to capture the reflected light field. The system exhibits a 3D resolution of ∼100 µm over an imaging depth of ∼22 mm and field of view up to 1 cm2. GLAM maintains a small form factor consistent with the clinically desirable design, making the system readily translatable to a clinical prototype.
- 5 January 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (2) , 590-607
Three-dimensional light-field microendoscopy with a GRIN lens array
Optical endoscopy has emerged as an indispensable clinical tool for modern minimally invasive surgery. Most systems primarily capture a 2D projection of the 3D surgical field. Currently available 3D endoscopes can restore stereoscopic vision directly by projecting laterally shifted views of the operating field to each eye through 3D glasses. These tools provide surgeons with informative 3D visualizations, but they do not enable quantitative volumetric rendering of tissue. Therefore, advanced tools are desired to quantify tissue tomography for high precision microsurgery or medical robotics. Light-field imaging suggests itself as a promising solution to the challenge. The approach can capture both the spatial and angular information of optical signals, permitting the computational synthesis of the 3D volume of an object. In this work, we present GRIN lens array microendoscopy (GLAM), a single-shot, full-color, and quantitative 3D microendoscopy system. GLAM contains integrated fiber optics for illumination and a GRIN lens array to capture the reflected light field. The system exhibits a 3D resolution of ∼100 µm over an imaging depth of ∼22 mm and field of view up to 1 cm2. GLAM maintains a small form factor consistent with the clinically desirable design, making the system readily translatable to a clinical prototype.