HEHarvey Edwards

Harvey Edwards

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Harvey Edwards has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Effect of an Imperfect Algorithm on Human Gait Strategies With an Active Ankle Exoskeleton

    by Man I Wu, Brian S. Baum, Harvey Edwards, Leia Stirling

    Lower-limb active exoskeletons may experience errors in operational settings due to imperfect algorithms, which may impact users' trust in the system and the human-exoskeleton fluency (the coordination of actions between the human and exoskeleton). In this study, we introduced pseudorandom catch trials (errors) in 1.68% of all strides, where an expected exoskeleton torque was not applied for a single stride, to understand the immediate and time-dependent responses to missed actuations. Participants (N = 15) completed a targeted stepping task while walking with a bilateral powered ankle exoskeleton. Human-exoskeleton fluency and trust were inferred from task performance (step accuracy), step characteristics (step length and width), muscle activity, and lower limb joint kinematics. Reductions in ankle plantarflexion during catch trials suggest user adaptation to the exoskeleton. Hip flexion and muscle activity were modulated to mitigate effects of the loss of exoskeleton torque and reduced plantarflexion during catch trials to support task accuracy and maintain step characteristics. Trust was not impacted by this level of error, as there were no significant differences in task performance or gait characteristics over time. Understanding the interactions between human-exoskeleton fluency, task accuracy, and gait strategies will support exoskeleton controller development. Future work will investigate various levels of actuation reliability to understand the transition where performance and trust are affected.


  • Alternative cue and response modalities maintain the Simon effect but impact task performance

    by Aditi Gupta, Harvey M. Edwards Iii, Aaron R. Rodriguez, Ryan J. McKindles, Leia A. Stirling


  • Open Access

    Ablation Analysis to Select Wearable Sensors for Classifying Standing, Walking, and Running

    by Sarah Gonzalez, Paul Stegall, Harvey Edwards, Leia Stirling, Ho Chit Siu

    The field of human activity recognition (HAR) often utilizes wearable sensors and machine learning techniques in order to identify the actions of the subject. This paper considers the activity recognition of walking and running while using a support vector machine (SVM) that was trained on principal components derived from wearable sensor data. An ablation analysis is performed in order to select the subset of sensors that yield the highest classification accuracy. The paper also compares principal components across trials to inform the similarity of the trials. Five subjects were instructed to perform standing, walking, running, and sprinting on a self-paced treadmill, and the data were recorded while using surface electromyography sensors (sEMGs), inertial measurement units (IMUs), and force plates. When all of the sensors were included, the SVM had over 90% classification accuracy using only the first three principal components of the data with the classes of stand, walk, and run/sprint (combined run and sprint class). It was found that sensors that were placed only on the lower leg produce higher accuracies than sensors placed on the upper leg. There was a small decrease in accuracy when the force plates are ablated, but the difference may not be operationally relevant. Using only accelerometers without sEMGs was shown to decrease the accuracy of the SVM.