Whitney Goldsborough Colella
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Whitney Goldsborough Colella has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Aditya Jhunjhunwala
Univ. of California, Davis
1 shared publication - Daniel M. Kammen
Renewable Energy and Equity Worldwide Laboratory, Johns Hopkins University
1 shared publication Monjid Hamdan
Giner ELX, Inc
1 shared publicationNigel Teo
Stanford University, Stanford, CA
1 shared publication- Stefan Schneider
GeoSphere Austria, 1190 Vienna, Austria
1 shared publication
Latest Publications
- 13 April 2018
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2018-01 (28) , 1600
Thermodynamic, Environmental, and Economic Analysis of Electrosynthesis of Hydrogen Fuel with State-of-the-Art Solid Oxide Electrolyzers
Gaia Energy Research Institute (Gaia) presents results for (1) a life cycle analysis (LCA) and (2) a technoeconomic analysis (TEA) of a state-of-the-art solid oxide electrolyzer (SOE) for electrosynthesis of hydrogen fuel. The significance of this work is that it quantifies potential reductions in greenhouse gas emissions (GHGs) and other environmental impacts with the use of SOEs. The significance of this work is that it also quantifies the potential future cost of producing extremely pure hydrogen using SOEs in dollars per kilogram of hydrogen ($/kg H2). 1: Life cycle analysis LCA results indicate that GHGs from the SOE can be lower than GHGs from steam methane reforming (SMR) of natural gas (the most prevalent technology for making hydrogen). To obtain this result, Gaia builds on the existing DOE models, including, but not limited to, the Argonne National Laboratory full life-cycle model, GREET (Greenhouse gases, Regulated Emissions, and Energy use in Transportation.) SOE GHG emissions are also evaluated through single-variable sensitivity studies and Tornado charts. Model results indicate that some of the input variables that are most impactful to GHGs include, but are not limited to, (1) the SOE stack and system electricity usages (kWh_electric/kg H2), (2) the SOE stack and system heat usages (kWh_thermal /kg H2), (3) the carbon footprint of the electricity input source to the SOE (kg carbon /kWh_electric), and (4) the carbon footprint of the thermal input source to the SOE (kg carbon /kWh_thermal). Also quantified are potential future changes in GHG emissions that result from further SOE technology advancements. These results are plotted in Waterfall Charts. In addition to GHGs, this analysis also considers life cycle air pollution emissions and solid waste streams. 2: Technoeconomic analysis TEA results indicate that the SOE is estimated to produce hydrogen at less than $2/kg H2, which is the DOE Fuel Cell Technologies Office’s (FCTO) H2 production cost target. To obtain this result, Gaia builds on existing DOE FCTO H2 production analysis modelling tools, including the H2A tools, and the existing FCTO SOE case studies and Excel-based models. Gaia deploys the FCTO's Hydrogen Analysis tools, including the H2A Production and H2A Delivery Scenario Analysis Model (HDSAM) models, to estimate the levelized cost of (1) producing, (2) delivering, (3) compressing, (4) storing and (5) dispensing H2 ($/kg H2). The levelized cost of producing H2 from SOEs is also analyzed using single-variable sensitivity studies and Tornado charts. (An important caveat is that H2A model results do not indicate optimal results for engineering design parameters or market conditions.) Model results indicate that some of the input variables that are most impactful to the levelized cost of producing H2 from SOEs include, but are not limited to, (1) the electricity price, (2) the purchase price for external heat going into the SOE stack, (3) the SOE stack and system capital costs, (4) the SOE stack and system electricity usages, (5) the SOE stack and system heat usages, (6) SOE stack and system lifetimes, and (7) the operating capacity factor. System costs include both stack and balance of plant costs. Also quantified are potential improvements in the levelized H2 production that result from further SOE technology advancements. These results are plotted in Waterfall Charts. Both current and future cases were analyzed for H2 generation with state-of-the-art SOE electrolyzers using the DOE’s H2A Production Model. For the state-of-the-art SOE system design analyzed here, uninstalled SOE system capital costs are expected to decline from $840/kWe to $640/kWe between current and future cases. Electricity usage is expected to decline from 37.61 kWh_e/kg H2 to 35.1 kWh_e/kg H2 between current and future cases. The current case reflects a ~$3 /kg levelized H2 production cost, based on an average cost of electricity of 2.5¢/kWh. The future case reflects a <$2 /kg levelized H2 production cost, based on an average cost of electricity of 2¢/kWh. Capital costs are the primary cost driver in current and future cases. The secondary cost driver is electricity costs. Between the current and the future case, the estimated levelized H2 production cost declines due to expected decreases in (1) SOE system capital costs (primarily at the stack), (2) indirect capital costs and replacement costs, (3) system energy consumption, (4) electricity price, and (5) fixed operations and maintenance costs. The LCA shows a 79% to 100% reduction in GHGs for hydrogen from the state-of-the-art SOE system analyzed here, compared with hydrogen from natural gas SMR.
- 13 April 2018
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2018-01 (28) , 1600
Thermodynamic, Environmental, and Economic Analysis of Electrosynthesis of Hydrogen Fuel with State-of-the-Art Solid Oxide Electrolyzers
Gaia Energy Research Institute (Gaia) presents results for (1) a life cycle analysis (LCA) and (2) a technoeconomic analysis (TEA) of a state-of-the-art solid oxide electrolyzer (SOE) for electrosynthesis of hydrogen fuel. The significance of this work is that it quantifies potential reductions in greenhouse gas emissions (GHGs) and other environmental impacts with the use of SOEs. The significance of this work is that it also quantifies the potential future cost of producing extremely pure hydrogen using SOEs in dollars per kilogram of hydrogen ($/kg H2). 1: Life cycle analysis LCA results indicate that GHGs from the SOE can be lower than GHGs from steam methane reforming (SMR) of natural gas (the most prevalent technology for making hydrogen). To obtain this result, Gaia builds on the existing DOE models, including, but not limited to, the Argonne National Laboratory full life-cycle model, GREET (Greenhouse gases, Regulated Emissions, and Energy use in Transportation.) SOE GHG emissions are also evaluated through single-variable sensitivity studies and Tornado charts. Model results indicate that some of the input variables that are most impactful to GHGs include, but are not limited to, (1) the SOE stack and system electricity usages (kWh_electric/kg H2), (2) the SOE stack and system heat usages (kWh_thermal /kg H2), (3) the carbon footprint of the electricity input source to the SOE (kg carbon /kWh_electric), and (4) the carbon footprint of the thermal input source to the SOE (kg carbon /kWh_thermal). Also quantified are potential future changes in GHG emissions that result from further SOE technology advancements. These results are plotted in Waterfall Charts. In addition to GHGs, this analysis also considers life cycle air pollution emissions and solid waste streams. 2: Technoeconomic analysis TEA results indicate that the SOE is estimated to produce hydrogen at less than $2/kg H2, which is the DOE Fuel Cell Technologies Office’s (FCTO) H2 production cost target. To obtain this result, Gaia builds on existing DOE FCTO H2 production analysis modelling tools, including the H2A tools, and the existing FCTO SOE case studies and Excel-based models. Gaia deploys the FCTO's Hydrogen Analysis tools, including the H2A Production and H2A Delivery Scenario Analysis Model (HDSAM) models, to estimate the levelized cost of (1) producing, (2) delivering, (3) compressing, (4) storing and (5) dispensing H2 ($/kg H2). The levelized cost of producing H2 from SOEs is also analyzed using single-variable sensitivity studies and Tornado charts. (An important caveat is that H2A model results do not indicate optimal results for engineering design parameters or market conditions.) Model results indicate that some of the input variables that are most impactful to the levelized cost of producing H2 from SOEs include, but are not limited to, (1) the electricity price, (2) the purchase price for external heat going into the SOE stack, (3) the SOE stack and system capital costs, (4) the SOE stack and system electricity usages, (5) the SOE stack and system heat usages, (6) SOE stack and system lifetimes, and (7) the operating capacity factor. System costs include both stack and balance of plant costs. Also quantified are potential improvements in the levelized H2 production that result from further SOE technology advancements. These results are plotted in Waterfall Charts. Both current and future cases were analyzed for H2 generation with state-of-the-art SOE electrolyzers using the DOE’s H2A Production Model. For the state-of-the-art SOE system design analyzed here, uninstalled SOE system capital costs are expected to decline from $840/kWe to $640/kWe between current and future cases. Electricity usage is expected to decline from 37.61 kWh_e/kg H2 to 35.1 kWh_e/kg H2 between current and future cases. The current case reflects a ~$3 /kg levelized H2 production cost, based on an average cost of electricity of 2.5¢/kWh. The future case reflects a <$2 /kg levelized H2 production cost, based on an average cost of electricity of 2¢/kWh. Capital costs are the primary cost driver in current and future cases. The secondary cost driver is electricity costs. Between the current and the future case, the estimated levelized H2 production cost declines due to expected decreases in (1) SOE system capital costs (primarily at the stack), (2) indirect capital costs and replacement costs, (3) system energy consumption, (4) electricity price, and (5) fixed operations and maintenance costs. The LCA shows a 79% to 100% reduction in GHGs for hydrogen from the state-of-the-art SOE system analyzed here, compared with hydrogen from natural gas SMR.
- 13 April 2018
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2018-01 (2) , 202
Energy Systems, Thermodynamic, and Financial Analysis of Low Temperature, Proton-Conducting Electrochemical Hydrogen Compressors (EHCs) for Distributed Energy Storage
This research analyses the potential for compressing hydrogen (H2) with low temperature, proton-conducting electrochemical hydrogen compressors (EHCs). Energy systems analysis, thermodynamic, and financial models are developed to analyse EHC systems in terms of their future engineering and economic performance. Currently, most EHCs are at an early technology readiness level (TRL); i.e. individual cells and stacks have been tested in controlled, laboratory environments. This work analyses state-of-the-art, best performing EHC cells, stacks, and systems, tested to-date in the laboratory, and projects their performance into the future for large-scale, commercial EHC systems for distributed energy storage. EHCs use electricity to split hydrogen molecules (H2) into hydrogen ions (H+) and electrons (e-). The overall, endothermic reaction is Electricity + H2 (low pressure) → H2 (high pressure). A power source delivers direct current (DC) electricity to the EHC electrodes such that, at the anode, H2 at low pressure split into H+ and e-. The e- flow through an external circuit, and the H+ flow through an electrolyte selectively conductive to H+. At the cathode, the H+ and e- recombine to form H2 at high pressure. EHCs can generate high purity, high pressure H2. The theoretical efficiency of EHCs is higher than that of mechanical piston and/or diaphragm compressors because they compress in a manner that is isothermal, rather than isentropic. This analysis focuses on low-temperature EHCs using proton-conducting membrane electrolytes. This research deploys custom-built energy systems analysis, thermodynamic, and financial models, as well as a U.S. Department of Energy (DOE) techno-economic modelling tool for H2 compression, called the HDSAM Model. The HDSAM Model captures a set of standard DOE assumptions and methods. When these standards are adhered to, using the HDSAM Model can facilitate more even-handed techno-economic comparisons of a variety of H2 compression, storage, and dispensing technologies. This analysis deploys energy systems analysis, thermodynamic, and financial models, including the HDSAM model, to evaluate H2 compression based on EHCs powered by electricity from the grid. Models were developed to describe small-scale, 2,400 kilograms (kg) H2/day, EHC compression systems envisioned for both the near and far-term futures. Model results indicate that, for an average electricity cost of about $0.06/kilowatt-hour (kWh), the levelized cost of compressing H2 with a state-of-the-art EHC systems could be as low as ~$0.50/kg H2 in the near-term. The levelized cost of compressing the H2 is most strongly influenced by the electricity price. Electricity costs constitute roughly 65% of the levelized cost. The levelized cost of compressing H2 is also impacted by the EHC system’s capital cost and the EHC’s electrical efficiency. Capital costs constitute roughly 35% of the levelized cost. Fixed operations and maintenance costs and other variable costs are negligible.
- 13 April 2018
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2018-01 (2) , 202
Energy Systems, Thermodynamic, and Financial Analysis of Low Temperature, Proton-Conducting Electrochemical Hydrogen Compressors (EHCs) for Distributed Energy Storage
This research analyses the potential for compressing hydrogen (H2) with low temperature, proton-conducting electrochemical hydrogen compressors (EHCs). Energy systems analysis, thermodynamic, and financial models are developed to analyse EHC systems in terms of their future engineering and economic performance. Currently, most EHCs are at an early technology readiness level (TRL); i.e. individual cells and stacks have been tested in controlled, laboratory environments. This work analyses state-of-the-art, best performing EHC cells, stacks, and systems, tested to-date in the laboratory, and projects their performance into the future for large-scale, commercial EHC systems for distributed energy storage. EHCs use electricity to split hydrogen molecules (H2) into hydrogen ions (H+) and electrons (e-). The overall, endothermic reaction is Electricity + H2 (low pressure) → H2 (high pressure). A power source delivers direct current (DC) electricity to the EHC electrodes such that, at the anode, H2 at low pressure split into H+ and e-. The e- flow through an external circuit, and the H+ flow through an electrolyte selectively conductive to H+. At the cathode, the H+ and e- recombine to form H2 at high pressure. EHCs can generate high purity, high pressure H2. The theoretical efficiency of EHCs is higher than that of mechanical piston and/or diaphragm compressors because they compress in a manner that is isothermal, rather than isentropic. This analysis focuses on low-temperature EHCs using proton-conducting membrane electrolytes. This research deploys custom-built energy systems analysis, thermodynamic, and financial models, as well as a U.S. Department of Energy (DOE) techno-economic modelling tool for H2 compression, called the HDSAM Model. The HDSAM Model captures a set of standard DOE assumptions and methods. When these standards are adhered to, using the HDSAM Model can facilitate more even-handed techno-economic comparisons of a variety of H2 compression, storage, and dispensing technologies. This analysis deploys energy systems analysis, thermodynamic, and financial models, including the HDSAM model, to evaluate H2 compression based on EHCs powered by electricity from the grid. Models were developed to describe small-scale, 2,400 kilograms (kg) H2/day, EHC compression systems envisioned for both the near and far-term futures. Model results indicate that, for an average electricity cost of about $0.06/kilowatt-hour (kWh), the levelized cost of compressing H2 with a state-of-the-art EHC systems could be as low as ~$0.50/kg H2 in the near-term. The levelized cost of compressing the H2 is most strongly influenced by the electricity price. Electricity costs constitute roughly 65% of the levelized cost. The levelized cost of compressing H2 is also impacted by the EHC system’s capital cost and the EHC’s electrical efficiency. Capital costs constitute roughly 35% of the levelized cost. Fixed operations and maintenance costs and other variable costs are negligible.
- 1 July 2017
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2017-03 (1) , 126
Life Cycle and Techno-Economic Analysis of State-of-the-Art Solid Oxide Electrolyzer Systems
Gaia Energy Research Institute (Gaia) presents results for (1) a life cycle analysis (LCA) and (2) a technoeconomic analysis (TEA) of a state-of-the-art solid oxide electrolyzer (SOE). Gaia analyzes a state-of-the-art SOE for making hydrogen, based on an SOE design by Ceramatec Inc. The significance of this work is that it quantifies potential reductions in greenhouse gas emissions (GHGs) and other environmental impacts with the use of SOEs. The significance of this work is that it also quantifies the potential future cost of producing extremely pure hydrogen using SOEs in dollars per kilogram of hydrogen ($/kg H2). 1: Life cycle analysis LCA results indicate that GHGs from the SOE can be at least ten percent (10%) lower than GHGs from steam methane reforming (SMR) of natural gas (the most prevalent technology for making hydrogen). To obtain this result, Gaia builds on the existing DOE models, including, but not limited to, the Argonne National Laboratory full life-cycle model, GREET (Greenhouse gases, Regulated Emissions, and Energy use in Transportation.) SOE GHG emissions are also evaluated through single-variable sensitivity studies and Tornado charts. Model results indicate that some of the input variables that are most impactful to GHGs include, but are not limited to, (1) the SOE stack and system electricity usages (kWh_electric/kg H2), (2) the SOE stack and system heat usages (kWh_thermal /kg H2), (3) the carbon footprint of the electricity input source to the SOE (kg carbon /kWh_electric), and (4) the carbon footprint of the thermal input source to the SOE (kg carbon /kWh_thermal). Also quantified are potential future changes in GHG emissions that result from further SOE technology advancements. These results are plotted in Waterfall Charts. Consideration also is given to scenarios in which H2 is delivered above ambient pressure, and where the energy input to the SOE includes intermittent renewable energy sources. In addition to GHGs, this analysis also considers life cycle air pollution emissions and solid waste streams. 2: Technoeconomic analysis TEA results indicate that the SOE is estimated to produce hydrogen at less than $2/kg H2, which is the DOE Fuel Cell Technologies Office’s (FCTO) H2 production cost target. To obtain this result, Gaia builds on existing DOE FCTO H2 production analysis modelling tools, including the H2A tools, and the existing FCTO SOE case studies and Excel-based models. Gaia deploys the FCTO's Hydrogen Analysis tools, including the H2A Production and H2A Delivery Scenario Analysis Model (HDSAM) models, to estimate the levelized cost of (1) producing, (2) delivering, (3) compressing, (4) storing and (5) dispensing H2 ($/kg H2). The levelized cost of producing H2 from SOEs is also analyzed using single-variable sensitivity studies and Tornado charts. Model results indicate that some of the input variables that are most impactful to the levelized cost of producing H2 from SOEs include, but are not limited to, (1) the electricity price (¢/kWh_electric), (2) the purchase price for external heat going into the SOE stack (¢/kWh_thermal), (3) the SOE stack and system capital costs ($/kW), (4) the SOE stack and system electricity usages (kWh_electric/kg H2), (5) the SOE stack and system heat usages (kWh_thermal/kg H2), (6) SOE stack and system lifetimes (years), and (7) the operating capacity factor (percent). System costs include both stack and balance of plant (BOP) costs. Also quantified are potential improvements in the levelized H2 production that result from further SOE technology advancements. These results are plotted in Waterfall Charts. Consideration also is given to scenarios in which H2 is delivered above ambient pressure, and where the energy input to the SOE includes intermittent renewable energy sources.
- 1 July 2017
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2017-03 (1) , 126
Life Cycle and Techno-Economic Analysis of State-of-the-Art Solid Oxide Electrolyzer Systems
Gaia Energy Research Institute (Gaia) presents results for (1) a life cycle analysis (LCA) and (2) a technoeconomic analysis (TEA) of a state-of-the-art solid oxide electrolyzer (SOE). Gaia analyzes a state-of-the-art SOE for making hydrogen, based on an SOE design by Ceramatec Inc. The significance of this work is that it quantifies potential reductions in greenhouse gas emissions (GHGs) and other environmental impacts with the use of SOEs. The significance of this work is that it also quantifies the potential future cost of producing extremely pure hydrogen using SOEs in dollars per kilogram of hydrogen ($/kg H2). 1: Life cycle analysis LCA results indicate that GHGs from the SOE can be at least ten percent (10%) lower than GHGs from steam methane reforming (SMR) of natural gas (the most prevalent technology for making hydrogen). To obtain this result, Gaia builds on the existing DOE models, including, but not limited to, the Argonne National Laboratory full life-cycle model, GREET (Greenhouse gases, Regulated Emissions, and Energy use in Transportation.) SOE GHG emissions are also evaluated through single-variable sensitivity studies and Tornado charts. Model results indicate that some of the input variables that are most impactful to GHGs include, but are not limited to, (1) the SOE stack and system electricity usages (kWh_electric/kg H2), (2) the SOE stack and system heat usages (kWh_thermal /kg H2), (3) the carbon footprint of the electricity input source to the SOE (kg carbon /kWh_electric), and (4) the carbon footprint of the thermal input source to the SOE (kg carbon /kWh_thermal). Also quantified are potential future changes in GHG emissions that result from further SOE technology advancements. These results are plotted in Waterfall Charts. Consideration also is given to scenarios in which H2 is delivered above ambient pressure, and where the energy input to the SOE includes intermittent renewable energy sources. In addition to GHGs, this analysis also considers life cycle air pollution emissions and solid waste streams. 2: Technoeconomic analysis TEA results indicate that the SOE is estimated to produce hydrogen at less than $2/kg H2, which is the DOE Fuel Cell Technologies Office’s (FCTO) H2 production cost target. To obtain this result, Gaia builds on existing DOE FCTO H2 production analysis modelling tools, including the H2A tools, and the existing FCTO SOE case studies and Excel-based models. Gaia deploys the FCTO's Hydrogen Analysis tools, including the H2A Production and H2A Delivery Scenario Analysis Model (HDSAM) models, to estimate the levelized cost of (1) producing, (2) delivering, (3) compressing, (4) storing and (5) dispensing H2 ($/kg H2). The levelized cost of producing H2 from SOEs is also analyzed using single-variable sensitivity studies and Tornado charts. Model results indicate that some of the input variables that are most impactful to the levelized cost of producing H2 from SOEs include, but are not limited to, (1) the electricity price (¢/kWh_electric), (2) the purchase price for external heat going into the SOE stack (¢/kWh_thermal), (3) the SOE stack and system capital costs ($/kW), (4) the SOE stack and system electricity usages (kWh_electric/kg H2), (5) the SOE stack and system heat usages (kWh_thermal/kg H2), (6) SOE stack and system lifetimes (years), and (7) the operating capacity factor (percent). System costs include both stack and balance of plant (BOP) costs. Also quantified are potential improvements in the levelized H2 production that result from further SOE technology advancements. These results are plotted in Waterfall Charts. Consideration also is given to scenarios in which H2 is delivered above ambient pressure, and where the energy input to the SOE includes intermittent renewable energy sources.
- 1 July 2017
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2017-03 (1) , 367
Preliminary Design for Manufacture and Assembly (DFMA) Cost Analysis of Low Temperature, Co-Generative Proton-Conducting Solid Oxide Fuel Cells (SOFC)
This work develops preliminary techno-economic models for a highly-innovative, next generation proton-conducting, anode-supported solid oxide fuel cell (SOFC) that integrates a methane coupling catalyst into the anode. This cell is under development by Argonne National Laboratory (ANL) and the Illinois Institute of Technology. The cell is currently at technology readiness level (TRL) 1, i.e. proof-of-concept at a laboratory bench scale. The cell is designed to co-produce electricity and fuels. This research develops a preliminary design for manufacture and assembly (DFMA) cost analysis for this cell design. This work summarizes (1) a specific physical embodiment of the ANL cell design modelled, (2) the bill of materials (BOM) for this modelled cell, and (3) preliminary cell, stack, and system cost estimates based on this cell. The techno-economic analysis (TEA) focuses on electrolyte-electrode assembly (EEA), or the ‘heart’ of the electrochemical cell, where the anode and cathode half-reactions occur. The project methodology is as follows: Develop a physical embodiment of the design for the EEA. Develop a Bill of Materials (BOM) that specifies masses and/or quantities of components and materials in the EEA. Obtain price quotes for materials in the EEA. Estimate materials costs for the EEA to develop a ‘price floor’ for minimum costs. Identify cost drivers within the EEA. Estimate fuel cell stack costs for a 100 kWe net electric stack mass-produced at a rate of 50,000 systems per year. Estimate fuel cell system costs for a 100 kWe net electric stack mass-produced at a rate of 50,000 systems per year. Preliminary results indicate that EEA is estimated to cost 5.56 cents/cm2 or $278/kW of gross electric power from the cell or stack. Within the EEA, the primary cost driver for the EEA appears to be the anode substrate, which is composed of yttrium-doped barium zirconate (BZY or BaZr(1-x)YxO3-d or sometimes BaZr0.8Y0.2Ox or BaZr0.9Y0.1O3-d), with barium zirconate represented as (BaZrO3), and nickel oxide (NiO). The BZY and NiO anode substrate material is estimated to cost either 2.88 cents/cm2 [based on price quotes for BZY from TransTech Inc.] or 16.40 cents/cm2 [based on price quotes from Praxair Specialty Ceramics]. The secondary cost driver for the EEA appears to be the anode’s methane coupling catalyst. The methane coupling catalyst is modelled as a dual metal catalyst composed of Platinum (Pt), gallium(III) oxide (Ga2O3), and silicon dioxide (SiO2). The catalyst material is estimated to cost 2.45 cents/cm2. About 94% of its cost is due to the material cost of platinum as a catalyst. Preliminary results also indicate that, for a 100 kW net electric stack mass-produced at a rate of 50,000 systems per year, the fuel cell stack subsystem cost is estimated to be ~$478/kW of net electric power from the system. This cost is approximately 74% higher than a ‘plain vanilla’ SOFC subsystem, analyzed by the author for DOE in a prior analysis. For a 100 kW net electric stack mass-produced at a rate of 50,000 systems per year, the overall fuel cell system cost including all BOP components is estimated to be ~$597/kW of net electric power from the system. This cost is approximately 48% higher than the entire ‘plain vanilla’ SOFC system, analyzed by the author for DOE in a prior analysis.
- 1 July 2017
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2017-03 (1) , 367
Preliminary Design for Manufacture and Assembly (DFMA) Cost Analysis of Low Temperature, Co-Generative Proton-Conducting Solid Oxide Fuel Cells (SOFC)
This work develops preliminary techno-economic models for a highly-innovative, next generation proton-conducting, anode-supported solid oxide fuel cell (SOFC) that integrates a methane coupling catalyst into the anode. This cell is under development by Argonne National Laboratory (ANL) and the Illinois Institute of Technology. The cell is currently at technology readiness level (TRL) 1, i.e. proof-of-concept at a laboratory bench scale. The cell is designed to co-produce electricity and fuels. This research develops a preliminary design for manufacture and assembly (DFMA) cost analysis for this cell design. This work summarizes (1) a specific physical embodiment of the ANL cell design modelled, (2) the bill of materials (BOM) for this modelled cell, and (3) preliminary cell, stack, and system cost estimates based on this cell. The techno-economic analysis (TEA) focuses on electrolyte-electrode assembly (EEA), or the ‘heart’ of the electrochemical cell, where the anode and cathode half-reactions occur. The project methodology is as follows: Develop a physical embodiment of the design for the EEA. Develop a Bill of Materials (BOM) that specifies masses and/or quantities of components and materials in the EEA. Obtain price quotes for materials in the EEA. Estimate materials costs for the EEA to develop a ‘price floor’ for minimum costs. Identify cost drivers within the EEA. Estimate fuel cell stack costs for a 100 kWe net electric stack mass-produced at a rate of 50,000 systems per year. Estimate fuel cell system costs for a 100 kWe net electric stack mass-produced at a rate of 50,000 systems per year. Preliminary results indicate that EEA is estimated to cost 5.56 cents/cm2 or $278/kW of gross electric power from the cell or stack. Within the EEA, the primary cost driver for the EEA appears to be the anode substrate, which is composed of yttrium-doped barium zirconate (BZY or BaZr(1-x)YxO3-d or sometimes BaZr0.8Y0.2Ox or BaZr0.9Y0.1O3-d), with barium zirconate represented as (BaZrO3), and nickel oxide (NiO). The BZY and NiO anode substrate material is estimated to cost either 2.88 cents/cm2 [based on price quotes for BZY from TransTech Inc.] or 16.40 cents/cm2 [based on price quotes from Praxair Specialty Ceramics]. The secondary cost driver for the EEA appears to be the anode’s methane coupling catalyst. The methane coupling catalyst is modelled as a dual metal catalyst composed of Platinum (Pt), gallium(III) oxide (Ga2O3), and silicon dioxide (SiO2). The catalyst material is estimated to cost 2.45 cents/cm2. About 94% of its cost is due to the material cost of platinum as a catalyst. Preliminary results also indicate that, for a 100 kW net electric stack mass-produced at a rate of 50,000 systems per year, the fuel cell stack subsystem cost is estimated to be ~$478/kW of net electric power from the system. This cost is approximately 74% higher than a ‘plain vanilla’ SOFC subsystem, analyzed by the author for DOE in a prior analysis. For a 100 kW net electric stack mass-produced at a rate of 50,000 systems per year, the overall fuel cell system cost including all BOP components is estimated to be ~$597/kW of net electric power from the system. This cost is approximately 48% higher than the entire ‘plain vanilla’ SOFC system, analyzed by the author for DOE in a prior analysis.
- 1 January 2008
- Published by ASME International
- p. 563-589
Part II of II: Deployment of MERESS Model—Designing, Controlling, and Installing Stationary Combined Heat and Power (CHP) Fuel Cell Systems (FCS) to Reduce Costs and Greenhouse Gas (GHG) Emissions
The Maximizing Emission Reductions and Economic Savings Simulator (MERESS) is an optimization tool that allows users to evaluate avant-garde strategies for installing and operating combined heat and power (CHP) fuel cell systems (FCSs) in buildings. This article discusses the deployment of MERESS to show illustrative results for a California campus town, and, based on these results, makes recommendations for further installations of FCSs to reduce greenhouse gas (GHG) emissions. MERESS is used to evaluate one of the most challenging FCS types to use for GHG reductions, the Phosphoric Acid Fuel Cell (PAFC) system. These PAFC FCSs are tested against a base case of a CHP combined cycle gas turbine (CCGT). Model results show that three competing goals (GHG emission reductions, cost savings to building owners, and FCS manufacturer sales revenue) are best achieved with different strategies, but that all three goals can be met reasonably with a single approach. According to MERESS, relative to a base case of only a CHP CCGT providing heat and electricity with no FCSs, the town achieves the highest 1) GHG emission reductions, 2) cost savings to building owners, and 3) FCS manufacturer sales revenue each with three different operating strategies, under a scenario of full incentives and a $100/tonne carbon dioxide (CO2 ) tax (Scenario D). The town achieves its maximum CO2 emission reduction, 37% relative to the base case, with operating Strategy V: stand alone operation (SA), no load following (NLF), and a fixed heat-to-power ratio (FHP) [SA, NLF, FHP] (Scenario E). The town’s building owners gain the highest cost savings, 25%, with Strategy I: electrically and thermally networked (NW), electricity power load following (ELF), and a variable heat-to-power ratio (VHP) [NW, ELF, VHP] (Scenario D). FCS manufacturers generally have the highest sales revenue with Strategy III: NW, NLF, with a fixed heat-to-power ratio (FHP) [NW, NLF, FHP] (Scenarios B, C, and D). Strategies III and V are partly consistent with the way that FCS manufacturers design their systems today, primarily as NLF with a FHP. By contrast, Strategy I is avant-garde for the fuel cell industry, in particular, in its use of a VHP and thermal networking. Model results further demonstrate that FCS installations can be economical for building owners without any carbon tax or government incentives. Without any carbon tax or state and federal incentives (Scenario A), Strategy I is marginally economical, with 3% energy cost savings, but with a 29% reduction in CO2 emissions. Strategy I is the most economical strategy for building owners in all scenarios (Scenarios A, B, C, and D) and, at the same time, reasonably achieves other goals of large GHG emission reductions and high FCS manufacturer sales revenue. Although no particular building type stands out as consistently achieving the highest emission reductions and cost savings (Scenarios B-2 and E-2), certain building load curves are clear winners. For example, buildings with load curves similar to Stanford’s Mudd Chemistry building (a wet laboratory) achieve maximal cost savings (1.5% with full federal and state incentives but no carbon tax) and maximal CO2 emission reductions (32%) (Scenarios B-2 and E-2). Finally, based on these results, this work makes recommendations for reducing GHG further through FCS deployment. (Part I of II articles discusses the motivation and key assumptions behind the MERESS model development (Colella 2008).)
- 1 January 2008
- Published by ASME International
- p. 563-589
Part II of II: Deployment of MERESS Model—Designing, Controlling, and Installing Stationary Combined Heat and Power (CHP) Fuel Cell Systems (FCS) to Reduce Costs and Greenhouse Gas (GHG) Emissions
The Maximizing Emission Reductions and Economic Savings Simulator (MERESS) is an optimization tool that allows users to evaluate avant-garde strategies for installing and operating combined heat and power (CHP) fuel cell systems (FCSs) in buildings. This article discusses the deployment of MERESS to show illustrative results for a California campus town, and, based on these results, makes recommendations for further installations of FCSs to reduce greenhouse gas (GHG) emissions. MERESS is used to evaluate one of the most challenging FCS types to use for GHG reductions, the Phosphoric Acid Fuel Cell (PAFC) system. These PAFC FCSs are tested against a base case of a CHP combined cycle gas turbine (CCGT). Model results show that three competing goals (GHG emission reductions, cost savings to building owners, and FCS manufacturer sales revenue) are best achieved with different strategies, but that all three goals can be met reasonably with a single approach. According to MERESS, relative to a base case of only a CHP CCGT providing heat and electricity with no FCSs, the town achieves the highest 1) GHG emission reductions, 2) cost savings to building owners, and 3) FCS manufacturer sales revenue each with three different operating strategies, under a scenario of full incentives and a $100/tonne carbon dioxide (CO2 ) tax (Scenario D). The town achieves its maximum CO2 emission reduction, 37% relative to the base case, with operating Strategy V: stand alone operation (SA), no load following (NLF), and a fixed heat-to-power ratio (FHP) [SA, NLF, FHP] (Scenario E). The town’s building owners gain the highest cost savings, 25%, with Strategy I: electrically and thermally networked (NW), electricity power load following (ELF), and a variable heat-to-power ratio (VHP) [NW, ELF, VHP] (Scenario D). FCS manufacturers generally have the highest sales revenue with Strategy III: NW, NLF, with a fixed heat-to-power ratio (FHP) [NW, NLF, FHP] (Scenarios B, C, and D). Strategies III and V are partly consistent with the way that FCS manufacturers design their systems today, primarily as NLF with a FHP. By contrast, Strategy I is avant-garde for the fuel cell industry, in particular, in its use of a VHP and thermal networking. Model results further demonstrate that FCS installations can be economical for building owners without any carbon tax or government incentives. Without any carbon tax or state and federal incentives (Scenario A), Strategy I is marginally economical, with 3% energy cost savings, but with a 29% reduction in CO2 emissions. Strategy I is the most economical strategy for building owners in all scenarios (Scenarios A, B, C, and D) and, at the same time, reasonably achieves other goals of large GHG emission reductions and high FCS manufacturer sales revenue. Although no particular building type stands out as consistently achieving the highest emission reductions and cost savings (Scenarios B-2 and E-2), certain building load curves are clear winners. For example, buildings with load curves similar to Stanford’s Mudd Chemistry building (a wet laboratory) achieve maximal cost savings (1.5% with full federal and state incentives but no carbon tax) and maximal CO2 emission reductions (32%) (Scenarios B-2 and E-2). Finally, based on these results, this work makes recommendations for reducing GHG further through FCS deployment. (Part I of II articles discusses the motivation and key assumptions behind the MERESS model development (Colella 2008).)