Nur Syafiqah Rasanang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nur Syafiqah Rasanang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Hamzah Arof
Department of Electrical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
2 shared publications- Salmah Binti Karman
Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur, Malaysia
2 shared publications - Sharifah Norsyahindah Syed Nor
Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur 50603, Malaysia
2 shared publications - Sulaiman Wadi Harun
Department of Electrical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur, Malaysia
2 shared publications - Wan Safwani Wan Kamarul Zaman
Department of Pharmaceutical Life Sciences, Faculty of Pharmacy, Universiti Malaya, Kuala Lumpur, Malaysia
2 shared publications
Latest Publications
- 9 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (5) , 6026-6037
Incorporation of Thiol-Modified and Carboxyl-MoS2 Films as Support Layer in Surface Plasmon Resonance Sensing Platform for SARS-CoV-2 Spike Protein Detection
In the event of a severe acute respiratory syndrome–coronavirus-2 (SARS-CoV-2) outbreak, rapid viral detection is crucial for proper patient management. Although the development of surface plasmon resonance (SPR) in optical biosensing for rapid viral detection is growing, gold (Au) as a metallic sensing surface for SPR biosensor exhibits inadequate sensitivity for sensitive viral recognition. Hence, this study attempted to fabricate a rapid and ultra-sensitive SPR detection platform using different support layers, such as self-assembled monolayer (SAM), consisting of 11-Mercaptoundecanoic acid (11-MUA), and 3-Mercaptopropionic acid (3-MPA) in addition to transition-metal dichalcogenide (TMDC) carboxyl-molybdenum disulfide (MoS 2 -COOH) for the detection of SARS-CoV-2 spike protein (S protein). The sensing surface was characterized using Raman spectroscopy, Fourier transform infrared (FTIR) spectroscopy, and transmission electron microscopy (TEM) before and after depositions, followed by SPR measurement testing with variation concentration of SARS-CoV-2 S protein. Performance parameters such as sensitivity, full width half maximum (FWHM), detection accuracy (DA), figure of merit (FoM), quality factor (QF), and limit of detection (LoD) are calculated and compared between 11-MUA/Au/BK7 prism, 3-MPA/Au/BK7 prism, and MoS 2 -COOH/Au/BK7 prism in the detection of SARS-CoV-2 S protein. Results show the SPR setup with MoS 2 -COOH single layer exhibited the highest sensitivity (203.55 °/RIU) compared to 11-MUA (89.89 °/RIU) and 3-MPA (108.90 °/RIU). Overall, all three configurations demonstrate good linearity, excellent sensitivity, and LoD in the ng/ml range. The outcome of this study hoped to aid in the future development of a non-invasive, rapid, and ultra-sensitive SPR detection platform for viral detection in minimal concentration.
- 9 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (5) , 6026-6037
Incorporation of Thiol-Modified and Carboxyl-MoS2 Films as Support Layer in Surface Plasmon Resonance Sensing Platform for SARS-CoV-2 Spike Protein Detection
In the event of a severe acute respiratory syndrome–coronavirus-2 (SARS-CoV-2) outbreak, rapid viral detection is crucial for proper patient management. Although the development of surface plasmon resonance (SPR) in optical biosensing for rapid viral detection is growing, gold (Au) as a metallic sensing surface for SPR biosensor exhibits inadequate sensitivity for sensitive viral recognition. Hence, this study attempted to fabricate a rapid and ultra-sensitive SPR detection platform using different support layers, such as self-assembled monolayer (SAM), consisting of 11-Mercaptoundecanoic acid (11-MUA), and 3-Mercaptopropionic acid (3-MPA) in addition to transition-metal dichalcogenide (TMDC) carboxyl-molybdenum disulfide (MoS 2 -COOH) for the detection of SARS-CoV-2 spike protein (S protein). The sensing surface was characterized using Raman spectroscopy, Fourier transform infrared (FTIR) spectroscopy, and transmission electron microscopy (TEM) before and after depositions, followed by SPR measurement testing with variation concentration of SARS-CoV-2 S protein. Performance parameters such as sensitivity, full width half maximum (FWHM), detection accuracy (DA), figure of merit (FoM), quality factor (QF), and limit of detection (LoD) are calculated and compared between 11-MUA/Au/BK7 prism, 3-MPA/Au/BK7 prism, and MoS 2 -COOH/Au/BK7 prism in the detection of SARS-CoV-2 S protein. Results show the SPR setup with MoS 2 -COOH single layer exhibited the highest sensitivity (203.55 °/RIU) compared to 11-MUA (89.89 °/RIU) and 3-MPA (108.90 °/RIU). Overall, all three configurations demonstrate good linearity, excellent sensitivity, and LoD in the ng/ml range. The outcome of this study hoped to aid in the future development of a non-invasive, rapid, and ultra-sensitive SPR detection platform for viral detection in minimal concentration.
- Open Access
- 29 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 1228-1244
A Review: Surface Plasmon Resonance-Based Biosensor for Early Screening of SARS-CoV2 Infection
Rapid viral diagnosis is essential to contain the spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV2) in the community and ensure effective patient management. However, the current gold standard for diagnosis of viral disease depends on the time-consuming molecular technique. Surface plasmon resonance (SPR) phenomenon has been widely applied in the analysis of biomolecular interactions and analytes detection, which is currently being investigated as a quick diagnostic method of numerous viral infections. In this regard, researchers have performed experimental studies dedicated to enhancing the sensitivity and specificity of the SPR sensor performance for utilization in the medical diagnostic field. In this review, we summarized various SPR application including the recent advancements and advantages of different types of SPR-based biosensor such prism-based, localized surface plasmon resonance (LSPR), fiber optic, optical grating, and optical waveguide for the detection of SARS-CoV2. We proposed various technical recommendations to improve the sensitivity, accuracy, time response, and cost-saving means of the SPR sensor. A special focus was set for sensitivity enhancement aspects in terms of the type of prism, nanomaterials, support layer with type and shape of optical fibers for early, swift, and ultra-sensitive detection of viral infection. With the highlighted impacts of SPR application, this review frames the current potential and challenges of SPR in comparison to the current gold standard of viral infection diagnostic strategy.
- 29 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 1228-1244
Open AccessA Review: Surface Plasmon Resonance-Based Biosensor for Early Screening of SARS-CoV2 Infection
Rapid viral diagnosis is essential to contain the spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV2) in the community and ensure effective patient management. However, the current gold standard for diagnosis of viral disease depends on the time-consuming molecular technique. Surface plasmon resonance (SPR) phenomenon has been widely applied in the analysis of biomolecular interactions and analytes detection, which is currently being investigated as a quick diagnostic method of numerous viral infections. In this regard, researchers have performed experimental studies dedicated to enhancing the sensitivity and specificity of the SPR sensor performance for utilization in the medical diagnostic field. In this review, we summarized various SPR application including the recent advancements and advantages of different types of SPR-based biosensor such prism-based, localized surface plasmon resonance (LSPR), fiber optic, optical grating, and optical waveguide for the detection of SARS-CoV2. We proposed various technical recommendations to improve the sensitivity, accuracy, time response, and cost-saving means of the SPR sensor. A special focus was set for sensitivity enhancement aspects in terms of the type of prism, nanomaterials, support layer with type and shape of optical fibers for early, swift, and ultra-sensitive detection of viral infection. With the highlighted impacts of SPR application, this review frames the current potential and challenges of SPR in comparison to the current gold standard of viral infection diagnostic strategy.