DSDaphne Schönegg

Daphne Schönegg

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Daphne Schönegg has a total of 54 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Five-Year Experience With Routine Use of Intraoperative Cone-Beam Computed Tomography in Zygomaticomaxillary Complex Fractures

    by Dominique Korner, Daphne Schönegg, Daniel Wiedemeier, Maximilian Eberhard Hermann Wagner, Harald Essig, Michael Blumer


  • Open Access

    Two versus three magnesium screws for osteosynthesis of mandibular condylar head fractures: a finite element analysis

    by Daphne Schönegg, Günter T. Müller, Michael Blumer, Harald Essig, Maximilian E. H. Wagner

    Objectives: Previous finite element analyses (FEA) have shown promising results for using two titanium screws in treating mandibular condylar head fractures but limited mechanical stability of a two-screw osteosynthesis with magnesium screws. Given the potential benefits of magnesium screws in terms of biocompatibility and resorption, this study aimed to compare two- and three-screw osteosynthesis solutions for a right condylar head fracture (AO CMF type p) with magnesium screws with a FEA. Materials and methods: A previously validated finite element model simulating a 350 N bite on the contralateral molars was used to analyze von Mises stress within the screws, fragment deformation, and fracture displacement. All screws were modeled with uniform geometric specifications mirroring the design of Medartis MODUS® Mandible Hexadrive cortical screws. Results: The three-screw configuration demonstrated lower values for all three parameters compared to the two-screw scenario. There was a 30% reduction in maximum von Mises stress for the top screw and a 46% reduction for the bottom screw. Conclusions: Fracture treatment with three magnesium screws could be a valuable and sufficiently stable alternative to the established treatment with titanium screws. Further studies on screw geometry could help improve material stability under mechanical loading, enhancing the performance of magnesium screws in clinical applications. Clinical relevance: The use of magnesium screws for osteosynthesis of mandibular condylar head fractures offers the benefit of reducing the need for second surgery for hardware removal. Clinical data is needed to determine whether the advantages of resorbable screw materials outweigh potential drawbacks in condylar head fracture treatment.


  • Open Access

    Intraosseous myofibroma mimicking an odontogenic lesion: case report, literature review, and differential diagnosis

    by José Wittor de Macêdo Santos, Benito K. Benitez, Daniel Baumhoer, Daphne Schönegg, Thomas Schrepfer, Andreas. A. Mueller, Florian M. Thieringer

    Background: Intraosseous myofibroma of the jaw is a rare neoplasm of mesenchymal origin with limited comprehensive understanding. It typically affects patients in the first two decades of life with a male predilection. Case presentation: This study presents a rare case of myofibroma mimicking an odontogenic lesion in a 2-year-old boy. The patient presented with an incidental finding of a painless swelling of the right mandibular ramus of unknown etiology. Imaging analysis revealed a solid, expansile lesion adjacent to the germinal zone of the right mandibular first molar. Histopathologic analysis and immunohistochemistry after incisional biopsy suggested a possible central odontogenic fibroma, and the patient underwent total enucleation, leading to the final diagnosis of intraosseous myofibroma. Follow-up examinations showed no evidence of recurrence. Conclusions: This report contributes to the understanding of myofibroma in pediatric patients and underscores the critical role of meticulous histopathologic examination for effective surgical planning and optimal patient outcomes.


  • Open Access

    Patient-specific beta-tricalcium phosphate scaffold for customized alveolar ridge augmentation: a case report

    by Daphne Schönegg, Harald Essig, Adib Al-Haj Husain, Franz E. Weber, Silvio Valdec

    Background: Beta-tricalcium phosphate (β-TCP) is a biocompatible ceramic material widely used in the field of oral regeneration. Due to its excellent biological and mechanical properties, it is increasingly utilized for alveolar ridge augmentation or guided bone regeneration (GBR). With recent advances in computer-aided design and manufacturing (CAD/CAM), β-TCP can now be used in the form of digitally designed patient-specific scaffolds for customized bone regeneration (CBR) of advanced defects in a two-stage implant therapy concept. In this case report following the CARE case report guidelines, we present a novel application of a patient-specific β-TCP scaffold in pre-implant mandibular alveolar ridge augmentation. Case presentation: A 63-year-old female patient with significant horizontal bone loss in the posterior mandible was treated with a custom β-TCP scaffold in the context of a two-stage backward-planned implant therapy. Cone-beam computed tomography nine months after augmentation showed successful integration of the scaffold into the surrounding bone, allowing implant placement. Follow-up until two years after initial surgery showed excellent oral and peri-implant health. Conclusions: This case highlights the potential of patient-specific β-TCP scaffolds for alveolar ridge augmentation and their advantage over traditional techniques, including avoidance of xeno-, allo-, and autografts. The results provide encouraging evidence for their use in clinical practice. Patient-specific β-TCP scaffolds may be a promising alternative for clinicians seeking to provide their patients with safe, predictable, and effective alveolar ridge augmentation results in customized bone regeneration procedures.


  • Surgical treatment of nasal fractures may benefit from intraoperative 3D imaging

    by Jan Hafner, Maximilian Eberhard Hermann Wagner, Priska Heinz, Daphne Schönegg, Harald Essig, Michael Blumer


  • Open Access

    Magnetic resonance imaging in dental implant surgery: a systematic review

    by Adib Al-Haj Husain, Marina Zollinger, Bernd Stadlinger, Mutlu Özcan, Sebastian Winklhofer, Nadin Al-Haj Husain, Daphne Schönegg, Marco Piccirelli, Silvio Valdec

    Purpose: To comprehensively assess the existing literature regarding the rapidly evolving in vivo application of magnetic resonance imaging (MRI) for potential applications, benefits, and challenges in dental implant surgery. Methods: Electronic and manual searches were conducted in PubMed MEDLINE, EMBASE, Biosis, and Cochrane databases by two reviewers following the PICOS search strategy. This involved using medical subject headings (MeSH) terms, keywords, and their combinations. Results: Sixteen studies were included in this systematic review. Of the 16, nine studies focused on preoperative planning and follow-up phases, four evaluated image-guided implant surgery, while three examined artifact reduction techniques. The current literature highlights several MRI protocols that have recently investigated and evaluated the in vivo feasibility and accuracy, focusing on its potential to provide surgically relevant quantitative and qualitative parameters in the assessment of osseointegration, peri-implant soft tissues, surrounding anatomical structures, reduction of artifacts caused by dental implants, and geometric accuracy relevant to implant placement. Black Bone and MSVAT-SPACE MRI, acquired within a short time, demonstrate improved hard and soft tissue resolution and offer high sensitivity in detecting pathological changes, making them a valuable alternative in targeted cases where CBCT is insufficient. Given the data heterogeneity, a meta-analysis was not possible. Conclusions: The results of this systematic review highlight the potential of dental MRI, within its indications and limitations, to provide perioperative surgically relevant parameters for accurate placement of dental implants. Graphical


  • Open Access

    Preoperative imaging in third molar surgery — A prospective comparison of X-ray-based and radiation-free magnetic resonance orthopantomography

    by Adib Al-Haj Husain, Dominik A. Oechslin, Bernd Stadlinger, Sebastian Winklhofer, Mutlu Özcan, Daphne Schönegg, Nadin Al-Haj Husain, Stefan Sommer, Marco Piccirelli, Silvio Valdec


  • Open Access

    Radioactive nanosized colloids and indocyanine green identify the same sentinel lymph nodes in oral squamous cell carcinoma

    by Lukas Hingsammer, Daphne Schönegg, Thomas Gander, Martin Lanzer

    Purpose: Near-infrared fluorescence imaging using indocyanine green (ICG) combined with radioactive markers has the potential to improve sentinel lymph-node (SLN) mapping in oral squamous cell carcinoma (OSCC). This study aimed to evaluate the ability of 99mTc and ICG in identifying the sentinel lymph nodes in patients with early stage OSCC. Methods: Data were collected prospectively, and a retrospective analysis of 15 patients with early stage OSCC and a cN0 neck was performed. All patients received peritumoral injection of 99mTc the day before surgery and ICG was administered intraoperatively. Intentionally, the application of the two different tracers were done by two different physicians with varying degrees of experience. The number of identified lymph nodes positive for 99mTc and ICG, the overlap or possible discrepancies of both methods, and the time until fluorescence signals of ICG were detected were noted. Results: In all patients, a 100% agreement in sentinel lymph-node identification was achieved, regardless of both the exact location of the peritumoral injection and the experience of the injecting surgeon. Time until ICG accumulation in the sentinel lymph node was consistently found to be between 1 and 3 min. Conclusion: ICG constitutes a viable and useful addition to 99mTc for intraoperative sentinel lymph-node detection in this study.


  • Open Access

    Two-screw osteosynthesis of the mandibular condylar head with different screw materials: a finite element analysis

    by Daphne Schönegg, Andreas Koch, Günter T. Müller, Michael Blumer, Maximilian E. H. Wagner

    This study compared the biomechanical behavior of titanium, magnesium, and polylactic acid screws for two-screw osteosynthesis of mandibular condylar head fractures using finite element analysis. Von Mises stress distribution, fracture displacement, and fragment deformation were evaluated. Titanium screws performed the best in terms of carrying the highest load, resulting in the least fracture displacement and fragment deformation. Magnesium screws showed intermediate results, while PLA screws were found to be unsuitable with stress values exceeding their tensile strength. These findings suggest that magnesium alloys could be considered a suitable alternative to titanium screws in mandibular condylar head osteosynthesis.


  • Open Access

    MR-orthopantomography in operative dentistry and oral and maxillofacial surgery: a proof of concept study

    by Adib Al-Haj Husain, Valérie Schmidt, Silvio Valdec, Bernd Stadlinger, Sebastian Winklhofer, Daphne Schönegg, Stefan Sommer, Mutlu Özcan, Nadin Al-Haj Husain, Marco Piccirelli

    This prospective study aimed to present, compare, and evaluate the suitability of five different magnetic resonance imaging (MRI) protocols (3D double-echo steady-state (DESS), 3D fast spin echo short-tau inversion recovery (SPACE-STIR), 3D fast spin echo spectral attenuated inversion recovery (SPACE-SPAIR), volumetric interpolated breath-hold examination (T1-VIBE-Dixon), and ultrashort echo time (UTE)) and for orthopantomogram (OPG)-like MRI reconstructions using a novel mandibular coil. Three readers assessed MR-OPGs of 21 volunteers regarding technical image quality (4, excellent; 0, severely reduced), susceptibility to artifacts (3, absence; 0, massive), and visualization of anatomical structures in the oral cavity and surrounding skeletal structures (4, fine details visible; 0, no structures visible). Average image quality was good (3.29 ± 0.83) for all MRI protocols, with UTE providing the best image quality (3.52 ± 0.62) and no to minor artifacts (2.56 ± 0.6). Full diagnostic interpretability of the osseous structures is best in VIBE-Dixon and UTE MR-OPGs. DESS provided excellent visualization of the finest details of the nervous tissue (3.95 ± 0.22). Intra-reader and inter-reader agreement between the readers was good to excellent for all protocols (ICCs 0.812–0.957). MR-OPGs provide indication-specific accurate imaging of the oral cavity and could contribute to the early detection of pathologies, staging, and radiological follow-up of oral and maxillofacial diseases.