Garrhett Glenn Via
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Garrhett Glenn Via has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- David Anthony Brueggeman
Wright State University Department of Orthopaedic Surgery, 1 Wyoming St., Dayton, OH, 45409, USA
6 shared publications - Andrew William Froehle
Department of Orthopaedic Surgery, Wright State University Boonshoft School of Medicine, Dayton, USA
5 shared publications David A. Brueggeman
Department of Orthopedic Surgery, Wright State University, Dayton, USA
4 shared publicationsJennifer L. Jerele
3 shared publications- Joseph Gabriel Lyons
Wright State University Boonshoft School of Medicine
3 shared publications Andrew D. Schneider
Department of Orthopedic Surgery, Wright State Boonshoft School of Medicine, Dayton, OH
2 shared publications
Latest Publications
- Open Access
- 29 July 2025
- Published by Elsevier in Journal of Clinical Orthopaedics and Trauma
- Vol. 69, 103142
Fascia iliaca compartment block and pericapsular nerve group block effect on opioid consumption in hip fracture patients
- 29 July 2025
- Published by Elsevier in Journal of Clinical Orthopaedics and Trauma
- Vol. 69, 103142
Open AccessFascia iliaca compartment block and pericapsular nerve group block effect on opioid consumption in hip fracture patients
- Open Access
- 11 September 2023
- Published by Elsevier in Journal of Orthopaedic Reports
- Vol. 2 (4)
Monotherapeutic cefotetan surgical prophylaxis: Current evidence and practice for orthopaedic surgeons
- 11 September 2023
- Published by Elsevier in Journal of Orthopaedic Reports
- Vol. 2 (4)
Open AccessMonotherapeutic cefotetan surgical prophylaxis: Current evidence and practice for orthopaedic surgeons
- 29 May 2023
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 49 (12) , 1272.e1-1272.e7
Automating Patient-Reported Outcome Measures Following Hand Surgery
- 29 May 2023
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 49 (12) , 1272.e1-1272.e7
Automating Patient-Reported Outcome Measures Following Hand Surgery
- Open Access
- 17 November 2022
- Published by Elsevier in Journal of Orthopaedic Reports
- Vol. 2 (1)
Bone fluorescence and fluorescence-guided debridement in orthopaedic surgery: Current evidence and practice
- 17 November 2022
- Published by Elsevier in Journal of Orthopaedic Reports
- Vol. 2 (1)
Open AccessBone fluorescence and fluorescence-guided debridement in orthopaedic surgery: Current evidence and practice
- Open Access
- 1 November 2022
- Published by Springer Nature in Arthroplasty
- Vol. 4 (1) , 1-11
Funding has no effect on clinical outcomes of total joint arthroplasty emerging technologies: a systematic review of bibliometrics and conflicts of interest
Background: The use of new total joint arthroplasty technologies, including patient-specific implants/instrumentation (PSI), computer-assisted (CA), and robotic-assisted (RA) techniques, is increasing. There is an ongoing debate regarding the value provided and potential concerns about conflicts of interest (COI). Methods: PRISMA guidelines were followed. PubMed, MEDLINE, and Web of Science databases were searched for total hip and knee arthroplasties, unicompartmental knee arthroplasties (UKA), PSI, CA, and RA. Bibliometric data, financial COI, clinical/functional scores, and patient-reported outcomes were assessed. Results: Eighty-seven studies were evaluated, with 35 (40.2%) including at least one author reporting COI, and 13 (14.9%) disclosing industry funding. COI and industry funding had no significant effects on outcomes (P = 0.682, P = 0.447), and there were no significant effects of conflicts or funding on level of evidence (P = 0.508, P = 0.826). Studies in which author(s) disclosed COI had significantly higher relative citation ratio (RCR) and impact factor (IF) than those without (P < 0.001, P = 0.032). Subanalysis demonstrated RA and PSI studies were more likely to report COI or industry funding (P = 0.045). RA (OR = 6.31, 95% CI: 1.61–24.68) and UKA (OR = 9.14, 95% CI: 1.43–58.53) had higher odds of reporting favorable outcomes than PSI. Conclusions: Author COIs (about 40%) may be lower than previously reported in orthopedic technologies/techniques reviews. Studies utilizing RA and PSI were more likely to report COI, while RA and UKA studies were more likely to report favorable outcomes than PSI. No statistically significant association between the presence of COIs and/or industry funding and the frequency of favorable outcomes or study level of evidence was found. Level of evidence: Level V Systematic Review
- 1 November 2022
- Published by Springer Nature in Arthroplasty
- Vol. 4 (1) , 1-11
Open AccessFunding has no effect on clinical outcomes of total joint arthroplasty emerging technologies: a systematic review of bibliometrics and conflicts of interest
Background: The use of new total joint arthroplasty technologies, including patient-specific implants/instrumentation (PSI), computer-assisted (CA), and robotic-assisted (RA) techniques, is increasing. There is an ongoing debate regarding the value provided and potential concerns about conflicts of interest (COI). Methods: PRISMA guidelines were followed. PubMed, MEDLINE, and Web of Science databases were searched for total hip and knee arthroplasties, unicompartmental knee arthroplasties (UKA), PSI, CA, and RA. Bibliometric data, financial COI, clinical/functional scores, and patient-reported outcomes were assessed. Results: Eighty-seven studies were evaluated, with 35 (40.2%) including at least one author reporting COI, and 13 (14.9%) disclosing industry funding. COI and industry funding had no significant effects on outcomes (P = 0.682, P = 0.447), and there were no significant effects of conflicts or funding on level of evidence (P = 0.508, P = 0.826). Studies in which author(s) disclosed COI had significantly higher relative citation ratio (RCR) and impact factor (IF) than those without (P < 0.001, P = 0.032). Subanalysis demonstrated RA and PSI studies were more likely to report COI or industry funding (P = 0.045). RA (OR = 6.31, 95% CI: 1.61–24.68) and UKA (OR = 9.14, 95% CI: 1.43–58.53) had higher odds of reporting favorable outcomes than PSI. Conclusions: Author COIs (about 40%) may be lower than previously reported in orthopedic technologies/techniques reviews. Studies utilizing RA and PSI were more likely to report COI, while RA and UKA studies were more likely to report favorable outcomes than PSI. No statistically significant association between the presence of COIs and/or industry funding and the frequency of favorable outcomes or study level of evidence was found. Level of evidence: Level V Systematic Review
- Open Access
- 18 October 2022
- Published by Elsevier in Journal of Orthopaedic Reports
- Vol. 1 (4)
Multifocal percutaneous pin fixation of talar neck fractures: An alternative to ORIF in the polytraumatized patient
- 18 October 2022
- Published by Elsevier in Journal of Orthopaedic Reports
- Vol. 1 (4)
Open AccessMultifocal percutaneous pin fixation of talar neck fractures: An alternative to ORIF in the polytraumatized patient
- 12 October 2022
- Published by Elsevier in Journal of Orthopaedics
- Vol. 34, 379-384
Effects of veterans’ mental health service-connections on patient-reported outcomes following total joint arthroplasty
- 12 October 2022
- Published by Elsevier in Journal of Orthopaedics
- Vol. 34, 379-384
Effects of veterans’ mental health service-connections on patient-reported outcomes following total joint arthroplasty
- 8 June 2022
- Published by Wolters Kluwer Health in Journal of Pediatric Orthopaedics
- Vol. 42 (7) , e767-e771
Screw Thread Configuration Has No Effect on Outcomes of In Situ Fixation for Stable Slipped Capital Femoral Epiphysis
Background: No consensus exists regarding the optimal surgical management of slipped capital femoral epiphysis (SCFE). Treatment goals include avoiding slip progression and sequelae such as avascular necrosis (AVN). Factors associated with surgical implants merit further research. This study investigates the effect of screw thread configuration and the number of screws on surgical outcomes. Methods: A total of 152 patients undergoing cannulated, stainless steel, in situ screw fixation of SCFE between January 2005 and April 2018 were included. Procedure laterality, screw number and thread configuration (partially threaded/fully threaded), bilateral diagnosis, Loder classification, final follow-up, patient demographics, and endocrinopathy history were analyzed. Primary outcomes were return to the operating room (ROR), AVN, hardware failure/removal, and femoroacetabular impingement (FAI). Results: Most patients received a single (86.2%), partially threaded (81.6%) screw; most were unilateral (67.8%) and stable (79.6%). Mean follow-up was 2.0±2.7 years, with a 15.8% rate of ROR, 5.3% exhibiting AVN, 6.6% exhibiting FAI, and 9.2% experiencing hardware failure/removal. Number of screws was the sole predictor of ROR [odds ratio (OR)=3.35, 95% confidence interval (CI): 1.18-9.49]. Unstable SCFE increased the odds of AVN (OR=38.44; 95% CI: 4.35-339.50) as did older age (OR=1.43, 95% CI: 1.01-2.03). Female sex increased risk for FAI (OR=4.87, 95% CI: 1.20-19.70), and bilateral SCFE elevated risk for hardware failure/removal versus unilateral SCFE (OR=4.41, 95% CI: 1.39-14.00). Screw thread configuration had no significant effect on any outcome (for each, P≥0.159). Conclusions: Rates of ROR, AVN, FAI, and hardware failure/removal did not differ between patients treated with partially threaded or fully threaded screws. The use of 2 screws was associated with an increased likelihood of ROR. These findings suggest that screw thread configuration has no impact on complication rates, whereas screw number may be an important consideration in SCFE fixation. Level of Evidence: Level III—retrospective cohort study.
- 8 June 2022
- Published by Wolters Kluwer Health in Journal of Pediatric Orthopaedics
- Vol. 42 (7) , e767-e771
Screw Thread Configuration Has No Effect on Outcomes of In Situ Fixation for Stable Slipped Capital Femoral Epiphysis
Background: No consensus exists regarding the optimal surgical management of slipped capital femoral epiphysis (SCFE). Treatment goals include avoiding slip progression and sequelae such as avascular necrosis (AVN). Factors associated with surgical implants merit further research. This study investigates the effect of screw thread configuration and the number of screws on surgical outcomes. Methods: A total of 152 patients undergoing cannulated, stainless steel, in situ screw fixation of SCFE between January 2005 and April 2018 were included. Procedure laterality, screw number and thread configuration (partially threaded/fully threaded), bilateral diagnosis, Loder classification, final follow-up, patient demographics, and endocrinopathy history were analyzed. Primary outcomes were return to the operating room (ROR), AVN, hardware failure/removal, and femoroacetabular impingement (FAI). Results: Most patients received a single (86.2%), partially threaded (81.6%) screw; most were unilateral (67.8%) and stable (79.6%). Mean follow-up was 2.0±2.7 years, with a 15.8% rate of ROR, 5.3% exhibiting AVN, 6.6% exhibiting FAI, and 9.2% experiencing hardware failure/removal. Number of screws was the sole predictor of ROR [odds ratio (OR)=3.35, 95% confidence interval (CI): 1.18-9.49]. Unstable SCFE increased the odds of AVN (OR=38.44; 95% CI: 4.35-339.50) as did older age (OR=1.43, 95% CI: 1.01-2.03). Female sex increased risk for FAI (OR=4.87, 95% CI: 1.20-19.70), and bilateral SCFE elevated risk for hardware failure/removal versus unilateral SCFE (OR=4.41, 95% CI: 1.39-14.00). Screw thread configuration had no significant effect on any outcome (for each, P≥0.159). Conclusions: Rates of ROR, AVN, FAI, and hardware failure/removal did not differ between patients treated with partially threaded or fully threaded screws. The use of 2 screws was associated with an increased likelihood of ROR. These findings suggest that screw thread configuration has no impact on complication rates, whereas screw number may be an important consideration in SCFE fixation. Level of Evidence: Level III—retrospective cohort study.