Kanghyun Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Kanghyun Kim has a total of 123 co-authors. Here are the top co-authors by number of shared publications:
- Roarke Horstmeyer
Department of Biomedical Engineering, Duke University, Durham, USA
16 shared publications - Kevin C. Zhou
Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, USA
10 shared publications - Lucas Kreiss
Department of Biomedical Engineering, Duke University, Durham, NC, USA
9 shared publications - Mark Harfouche
Ramona Optics, Inc
9 shared publications Paul Reamey
9 shared publicationsAmey Chaware
8 shared publications
Latest Publications
- Open Access
- 15 September 2026
- Published by Elsevier in Cell Reports Methods
Parallelized bright-field and fluorescence imaging platform for organoids
- 15 September 2026
- Published by Elsevier in Cell Reports Methods
Open AccessParallelized bright-field and fluorescence imaging platform for organoids
- Top Cited PapersOpen Access
- 23 January 2026
- Published by Springer Nature in Communications Biology
- Vol. 9 (1)
High-throughput multi-camera array microscope platform for automated 3D behavioral analysis of swimming zebrafish larvae
Understanding the behavioral and morphological dynamics of moving model organisms like the zebrafish larvae requires accurate, high-throughput 3D analysis. However, traditional single-view 2D video tracking fails to capture the full scope of natural 3D movements and postural dynamics. Here, we present a novel high-throughput 24-camera array microscope with a co-designed “mirrored well plate" that allows for snapshot imaging of up to 48 wells over a 118 mm × 82 mm field of view from two orthogonal directions (i.e., a top-view and side-view). Accurate 3D position estimation and tracking is achieved with an efficient machine learning algorithm that scales well to high-throughput measurements. The proposed approach automates parallelized 3D model organism behavioral analysis, providing 3D skeletal tracking, swim bladder morphological dynamics, and kinematics of up to 48 swimming zebrafish larvae at up to several hundred frames per second. The result is an efficient and scalable solution for high-throughput 3D behavioral studies with broad compatibility with standard workflows across laboratories and procedures working with pharmacology, toxicology, and neuroscience.
- 23 January 2026
- Published by Springer Nature in Communications Biology
- Vol. 9 (1)
Top Cited PapersOpen AccessHigh-throughput multi-camera array microscope platform for automated 3D behavioral analysis of swimming zebrafish larvae
Understanding the behavioral and morphological dynamics of moving model organisms like the zebrafish larvae requires accurate, high-throughput 3D analysis. However, traditional single-view 2D video tracking fails to capture the full scope of natural 3D movements and postural dynamics. Here, we present a novel high-throughput 24-camera array microscope with a co-designed “mirrored well plate" that allows for snapshot imaging of up to 48 wells over a 118 mm × 82 mm field of view from two orthogonal directions (i.e., a top-view and side-view). Accurate 3D position estimation and tracking is achieved with an efficient machine learning algorithm that scales well to high-throughput measurements. The proposed approach automates parallelized 3D model organism behavioral analysis, providing 3D skeletal tracking, swim bladder morphological dynamics, and kinematics of up to 48 swimming zebrafish larvae at up to several hundred frames per second. The result is an efficient and scalable solution for high-throughput 3D behavioral studies with broad compatibility with standard workflows across laboratories and procedures working with pharmacology, toxicology, and neuroscience.
- Open Access
- 18 December 2025
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 8 (1) , 015025
Semi-supervised virtual staining using learned-illumination Fourier ptychography for high-speed label-free histopathology
Virtual staining techniques enable the digital transformation of label-free images into clinically standardized stained images. However, the high costs and time involved in generating labeled datasets for training, combined with the absence of accelerated inference pipelines for high-throughput histopathology workflows remain major challenges to their widespread adoption in clinical practice. To overcome these limitations, we present a hardware-software co-designed system that integrates high-speed Fourier ptychographic microscopy with learned illumination, supported by a semi-supervised learning framework. Our end-to-end approach employs a learned multiplexed illumination strategy that significantly reduces acquisition time while maintaining high spatial resolution across a wide field of view. On the algorithmic side, a multi-stage neural network decouples phase reconstruction from colorization, and a contrastive learning framework further generalize the virtual staining by encouraging the network to focus on intrinsic tissue features rather than absorption-induced variations. Extensive experimental results confirm the effectiveness of our method, demonstrating accurate virtual staining of label-free images while providing a scalable and cost-effective alternative to traditional histochemical staining.
- 18 December 2025
- Published by IOP Publishing in Journal of Physics: Photonics
- Vol. 8 (1) , 015025
Open AccessSemi-supervised virtual staining using learned-illumination Fourier ptychography for high-speed label-free histopathology
Virtual staining techniques enable the digital transformation of label-free images into clinically standardized stained images. However, the high costs and time involved in generating labeled datasets for training, combined with the absence of accelerated inference pipelines for high-throughput histopathology workflows remain major challenges to their widespread adoption in clinical practice. To overcome these limitations, we present a hardware-software co-designed system that integrates high-speed Fourier ptychographic microscopy with learned illumination, supported by a semi-supervised learning framework. Our end-to-end approach employs a learned multiplexed illumination strategy that significantly reduces acquisition time while maintaining high spatial resolution across a wide field of view. On the algorithmic side, a multi-stage neural network decouples phase reconstruction from colorization, and a contrastive learning framework further generalize the virtual staining by encouraging the network to focus on intrinsic tissue features rather than absorption-induced variations. Extensive experimental results confirm the effectiveness of our method, demonstrating accurate virtual staining of label-free images while providing a scalable and cost-effective alternative to traditional histochemical staining.
- Open Access
Parallelized Brightfield and Fluorescence Imaging of Organoids Using a Scalable Multi-Camera Platform
Organoid viability, maturation, and growth is commonly assayed through brightfield and fluorescence microscopy using a single objective lens. However, standard microscopic imaging systems pose significant limitations for high-throughput applications, particularly in large-scale experiments where simultaneous imaging of multiple organoids requires increased throughput. There is a strong need for systems that can capture organoid growth rapidly and consistently while minimizing disturbances to culture conditions. Here, we present a novel multi-camera array scanner (MCAS) that parallelizes imaging through the simultaneous use of 48 objective lenses and sensors, resulting in a 95% reduction in acquisition times compared to commercial high-content imagers. We demonstrate and validate this system in multiple well plate formats, in both 2D and 3D neural cell cultures, and in brightfield and fluorescence. The MCAS improves efficiency for measuring organoid growth rates, assessing responses to morphogens and drugs, and measuring viral transduction efficiency. Together, these findings establish the MCAS as a scalable and versatile imaging platform for rapid phenotyping in organoid research.
Open AccessParallelized Brightfield and Fluorescence Imaging of Organoids Using a Scalable Multi-Camera Platform
Organoid viability, maturation, and growth is commonly assayed through brightfield and fluorescence microscopy using a single objective lens. However, standard microscopic imaging systems pose significant limitations for high-throughput applications, particularly in large-scale experiments where simultaneous imaging of multiple organoids requires increased throughput. There is a strong need for systems that can capture organoid growth rapidly and consistently while minimizing disturbances to culture conditions. Here, we present a novel multi-camera array scanner (MCAS) that parallelizes imaging through the simultaneous use of 48 objective lenses and sensors, resulting in a 95% reduction in acquisition times compared to commercial high-content imagers. We demonstrate and validate this system in multiple well plate formats, in both 2D and 3D neural cell cultures, and in brightfield and fluorescence. The MCAS improves efficiency for measuring organoid growth rates, assessing responses to morphogens and drugs, and measuring viral transduction efficiency. Together, these findings establish the MCAS as a scalable and versatile imaging platform for rapid phenotyping in organoid research.
- Open Access
High-throughput multi-camera array microscope platform for automated 3D behavioral analysis of swimming zebrafish larvae
Understanding the behavioral and morphological dynamics of moving model organisms like the zebrafish larvae requires accurate, high-throughput 3D analysis. However, traditional single-view 2D video tracking fails to capture the full scope of natural 3D movements and postural dynamics. Here, we present a novel high-throughput 24-camera array microscope with a co-designed “mirrored well plate” that allows for snapshot imaging of up to 48 wells over a 118 mm × 82 mm field of view from two orthogonal directions (i.e., a top-view and side-view). Accurate 3D position estimation and tracking is achieved with an efficient machine learning algorithm that scales well to high-throughput measurements. The proposed approach automates parallelized 3D model organism behavioral analysis, providing 3D skeletal tracking, swim bladder morphological dynamics, and kinematics of up to 48 swimming zebrafish larvae at up to several hundred frames per second. The result is an efficient and scalable solution for high-throughput 3D behavioral studies with broad compatibility with standard workflows across laboratories and procedures working with pharmacology, toxicology, and neuroscience.
Open AccessHigh-throughput multi-camera array microscope platform for automated 3D behavioral analysis of swimming zebrafish larvae
Understanding the behavioral and morphological dynamics of moving model organisms like the zebrafish larvae requires accurate, high-throughput 3D analysis. However, traditional single-view 2D video tracking fails to capture the full scope of natural 3D movements and postural dynamics. Here, we present a novel high-throughput 24-camera array microscope with a co-designed “mirrored well plate” that allows for snapshot imaging of up to 48 wells over a 118 mm × 82 mm field of view from two orthogonal directions (i.e., a top-view and side-view). Accurate 3D position estimation and tracking is achieved with an efficient machine learning algorithm that scales well to high-throughput measurements. The proposed approach automates parallelized 3D model organism behavioral analysis, providing 3D skeletal tracking, swim bladder morphological dynamics, and kinematics of up to 48 swimming zebrafish larvae at up to several hundred frames per second. The result is an efficient and scalable solution for high-throughput 3D behavioral studies with broad compatibility with standard workflows across laboratories and procedures working with pharmacology, toxicology, and neuroscience.
- Open Access
- 30 June 2025
- Published by SPIE-Intl Soc Optical Eng in Advanced Photonics Nexus
- Vol. 4 (04) , 1-15
Fourier lightfield multiview stereoscope for large field-of-view 3D imaging in microsurgical settings
We present the Fourier lightfield multiview stereoscope (FiLM-Scope). This imaging device combines concepts from Fourier lightfield microscopy and multiview stereo imaging to capture high-resolution 3D videos over large fields of view. The FiLM-Scope optical hardware consists of a multicamera array, with 48 individual microcameras, placed behind a high-throughput primary lens. This allows the FiLM-Scope to simultaneously capture 48 unique 12.8 megapixel images of a 28×37 mm field-of-view, from unique angular perspectives over a 21 deg×29 deg range, with down to 22 μm lateral resolution. We also describe a self-supervised algorithm to reconstruct 3D height maps from these images. Our approach demonstrates height accuracy down to 11 μm. To showcase the utility of our system, we perform tool tracking over the surface of an ex vivo rat skull and visualize the 3D deformation in stretching human skin, with videos captured at up to 100 frames per second. The FiLM-Scope has the potential to improve 3D visualization in a range of microsurgical settings.
- 30 June 2025
- Published by SPIE-Intl Soc Optical Eng in Advanced Photonics Nexus
- Vol. 4 (04) , 1-15
Open AccessFourier lightfield multiview stereoscope for large field-of-view 3D imaging in microsurgical settings
We present the Fourier lightfield multiview stereoscope (FiLM-Scope). This imaging device combines concepts from Fourier lightfield microscopy and multiview stereo imaging to capture high-resolution 3D videos over large fields of view. The FiLM-Scope optical hardware consists of a multicamera array, with 48 individual microcameras, placed behind a high-throughput primary lens. This allows the FiLM-Scope to simultaneously capture 48 unique 12.8 megapixel images of a 28×37 mm field-of-view, from unique angular perspectives over a 21 deg×29 deg range, with down to 22 μm lateral resolution. We also describe a self-supervised algorithm to reconstruct 3D height maps from these images. Our approach demonstrates height accuracy down to 11 μm. To showcase the utility of our system, we perform tool tracking over the surface of an ex vivo rat skull and visualize the 3D deformation in stretching human skin, with videos captured at up to 100 frames per second. The FiLM-Scope has the potential to improve 3D visualization in a range of microsurgical settings.
- Open Access
- 1 April 2025
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 12 (02) , 1-22
Beneath the surface: revealing deep-tissue blood flow in human subjects with massively parallelized diffuse correlation spectroscopy
SignificanceDiffuse correlation spectroscopy (DCS) allows label-free, non-invasive investigation of microvascular dynamics deep within tissue, such as cerebral blood flow (CBF). However, the signal-to-noise ratio (SNR) in DCS limits its effective cerebral sensitivity in adults, in which the depth to the brain, through the scalp and skull, is substantially larger than in infants.AimTherefore, we aim to increase its SNR and, ultimately, its sensitivity to CBF through new DCS techniques.ApproachWe present an in vivo demonstration of parallelized DCS (PDCS) to measure cerebral and muscular blood flow in healthy adults. Our setup employs an innovative array with hundreds of thousands single photon avalanche diodes (SPAD) in a 500×500 grid to boost SNR by averaging all independent pixel measurements. We tested this device on different total pixel counts and frame rates. A secondary, smaller array was used for reference measurements from shallower tissue at lower source-detector-separation (SDS).ResultsThe new system can measure pulsatile blood flow in cerebral and muscular tissue, at up to 4 cm SDS, while maintaining a similar measurement noise as compared with a previously published 32×32 PDCS system at 1.5 cm SDS. Data from a cohort of 15 adults provide strong experimental evidence for functional CBF activity during a cognitive memory task and allowed analysis of pulse markers. Additional control experiments on muscular blood flow in the forearm with a different technical configuration provide converging evidence for the efficacy of this technique.ConclusionsOur results outline successful PDCS measurements with large SPAD arrays to enable detect CBF in human adults. The ongoing development of SPAD camera technology is expected to result in larger and faster detectors in the future. In combination with new data processing techniques, tailored for the sparse signal of binary photon detection events in SPADs, this could lead to even greater SNR increase and ultimately greater depth sensitivity of PDCS.
- 1 April 2025
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 12 (02) , 1-22
Open AccessBeneath the surface: revealing deep-tissue blood flow in human subjects with massively parallelized diffuse correlation spectroscopy
SignificanceDiffuse correlation spectroscopy (DCS) allows label-free, non-invasive investigation of microvascular dynamics deep within tissue, such as cerebral blood flow (CBF). However, the signal-to-noise ratio (SNR) in DCS limits its effective cerebral sensitivity in adults, in which the depth to the brain, through the scalp and skull, is substantially larger than in infants.AimTherefore, we aim to increase its SNR and, ultimately, its sensitivity to CBF through new DCS techniques.ApproachWe present an in vivo demonstration of parallelized DCS (PDCS) to measure cerebral and muscular blood flow in healthy adults. Our setup employs an innovative array with hundreds of thousands single photon avalanche diodes (SPAD) in a 500×500 grid to boost SNR by averaging all independent pixel measurements. We tested this device on different total pixel counts and frame rates. A secondary, smaller array was used for reference measurements from shallower tissue at lower source-detector-separation (SDS).ResultsThe new system can measure pulsatile blood flow in cerebral and muscular tissue, at up to 4 cm SDS, while maintaining a similar measurement noise as compared with a previously published 32×32 PDCS system at 1.5 cm SDS. Data from a cohort of 15 adults provide strong experimental evidence for functional CBF activity during a cognitive memory task and allowed analysis of pulse markers. Additional control experiments on muscular blood flow in the forearm with a different technical configuration provide converging evidence for the efficacy of this technique.ConclusionsOur results outline successful PDCS measurements with large SPAD arrays to enable detect CBF in human adults. The ongoing development of SPAD camera technology is expected to result in larger and faster detectors in the future. In combination with new data processing techniques, tailored for the sparse signal of binary photon detection events in SPADs, this could lead to even greater SNR increase and ultimately greater depth sensitivity of PDCS.
- 17 January 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (2) , 617-627
Recording dynamic facial micro-expressions with a multi-focus camera array
We present a multi-camera array for capturing dynamic high-resolution videos of the human face. Compared to traditional single-camera configurations, our array of 54 individual cameras allows stitching of high-resolution composite video frames (709 megapixels total). In our novel multi-focus strategy, each camera in the array focuses on a unique object plane to resolve non-planar surfaces at a higher resolution than a standard single-lens camera design. By overcoming the standard resolution and depth-of-field (DOF) tradeoffs, we use our array design to capture video of macroscopically curved surfaces such as the human face at a lateral resolution of 26.14 ± 5.8 µm across a composite DOF of ∼43 mm that covers the entire face (85 cm2+ FOV). Compared to a single-focus configuration, this is almost a 10-fold increase in effective DOF. We demonstrate how our multi-focus camera array can capture dynamic facial expressions at microscopic resolution with relevance in several biomedical applications.
- 17 January 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (2) , 617-627
Recording dynamic facial micro-expressions with a multi-focus camera array
We present a multi-camera array for capturing dynamic high-resolution videos of the human face. Compared to traditional single-camera configurations, our array of 54 individual cameras allows stitching of high-resolution composite video frames (709 megapixels total). In our novel multi-focus strategy, each camera in the array focuses on a unique object plane to resolve non-planar surfaces at a higher resolution than a standard single-lens camera design. By overcoming the standard resolution and depth-of-field (DOF) tradeoffs, we use our array design to capture video of macroscopically curved surfaces such as the human face at a lateral resolution of 26.14 ± 5.8 µm across a composite DOF of ∼43 mm that covers the entire face (85 cm2+ FOV). Compared to a single-focus configuration, this is almost a 10-fold increase in effective DOF. We demonstrate how our multi-focus camera array can capture dynamic facial expressions at microscopic resolution with relevance in several biomedical applications.
- Open Access
- 1 March 2024
- Published by SPIE-Intl Soc Optical Eng in Advanced Photonics
- Vol. 6 (02) , 026004-11
Tensorial tomographic Fourier ptychography with applications to muscle tissue imaging
Quantitative phase imaging (QPI) is a well-known label-free microscopy approach that can detect phase delay introduced by semitransparent cells and tissue.1 Due in part to its ability to provide quantitative information about primarily transparent biological specimens with low phototoxicity, QPI has become an invaluable tool in scientific and clinical studies, including for monitoring neuronal firing2 and cancer cell line detection,3 to name a few. Besides scalar phase contrast, transparent specimens also exhibit alternative and important endogenous optical contrast mechanisms, including anisotropic properties such as material birefringence and orientation. Indeed, the orientation of molecular arrangements in lipid membranes can now be quantitatively monitored with polarization-sensitive microscopes for studying multi-organelle interactive activities.4,5 There are naturally a variety of polarization-sensitive microscope arrangements, including early analog designs,6,7 differential interference contrast (DIC) methods,8 and contemporary digital approaches that reconstruct quantitative specimen retardance and orientation.9 – 11 These methods have been applied to study small model organisms12,13 and to assist clinical diagnosis.14 – 17
- 1 March 2024
- Published by SPIE-Intl Soc Optical Eng in Advanced Photonics
- Vol. 6 (02) , 026004-11
Open AccessTensorial tomographic Fourier ptychography with applications to muscle tissue imaging
Quantitative phase imaging (QPI) is a well-known label-free microscopy approach that can detect phase delay introduced by semitransparent cells and tissue.1 Due in part to its ability to provide quantitative information about primarily transparent biological specimens with low phototoxicity, QPI has become an invaluable tool in scientific and clinical studies, including for monitoring neuronal firing2 and cancer cell line detection,3 to name a few. Besides scalar phase contrast, transparent specimens also exhibit alternative and important endogenous optical contrast mechanisms, including anisotropic properties such as material birefringence and orientation. Indeed, the orientation of molecular arrangements in lipid membranes can now be quantitatively monitored with polarization-sensitive microscopes for studying multi-organelle interactive activities.4,5 There are naturally a variety of polarization-sensitive microscope arrangements, including early analog designs,6,7 differential interference contrast (DIC) methods,8 and contemporary digital approaches that reconstruct quantitative specimen retardance and orientation.9 – 11 These methods have been applied to study small model organisms12,13 and to assist clinical diagnosis.14 – 17
- Open Access
- 7 December 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (12) , e0295711
Automated, high-throughput quantification of EGFP-expressing neutrophils in zebrafish by machine learning and a highly-parallelized microscope
Normal development of the immune system is essential for overall health and disease resistance. Bony fish, such as the zebrafish (Danio rerio), possess all the major immune cell lineages as mammals and can be employed to model human host response to immune challenge. Zebrafish neutrophils, for example, are present in the transparent larvae as early as 48 hours post fertilization and have been examined in numerous infection and immunotoxicology reports. One significant advantage of the zebrafish model is the ability to affordably generate high numbers of individual larvae that can be arrayed in multi-well plates for high throughput genetic and chemical exposure screens. However, traditional workflows for imaging individual larvae have been limited to low-throughput studies using traditional microscopes and manual analyses. Using a newly developed, parallelized microscope, the Multi-Camera Array Microscope (MCAM™), we have optimized a rapid, high-resolution algorithmic method to count fluorescently labeled cells in zebrafish larvae in vivo. Using transgenic zebrafish larvae, in which neutrophils express EGFP, we captured 18 gigapixels of images across a full 96-well plate, in 75 seconds, and processed the resulting datastream, counting individual fluorescent neutrophils in all individual larvae in 5 minutes. This automation is facilitated by a machine learning segmentation algorithm that defines the most in-focus view of each larva in each well after which pixel intensity thresholding and blob detection are employed to locate and count fluorescent cells. We validated this method by comparing algorithmic neutrophil counts to manual counts in larvae subjected to changes in neutrophil numbers, demonstrating the utility of this approach for high-throughput genetic and chemical screens where a change in neutrophil number is an endpoint metric. Using the MCAM™ we have been able to, within minutes, acquire both enough data to create an automated algorithm and execute a biological experiment with statistical significance. Finally, we present this open-source software package which allows the user to train and evaluate a custom machine learning segmentation model and use it to localize zebrafish and analyze cell counts within the segmented region of interest. This software can be modified as needed for studies involving other zebrafish cell lineages using different transgenic reporter lines and can also be adapted for studies using other amenable model species.
- 7 December 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (12) , e0295711
Open AccessAutomated, high-throughput quantification of EGFP-expressing neutrophils in zebrafish by machine learning and a highly-parallelized microscope
Normal development of the immune system is essential for overall health and disease resistance. Bony fish, such as the zebrafish (Danio rerio), possess all the major immune cell lineages as mammals and can be employed to model human host response to immune challenge. Zebrafish neutrophils, for example, are present in the transparent larvae as early as 48 hours post fertilization and have been examined in numerous infection and immunotoxicology reports. One significant advantage of the zebrafish model is the ability to affordably generate high numbers of individual larvae that can be arrayed in multi-well plates for high throughput genetic and chemical exposure screens. However, traditional workflows for imaging individual larvae have been limited to low-throughput studies using traditional microscopes and manual analyses. Using a newly developed, parallelized microscope, the Multi-Camera Array Microscope (MCAM™), we have optimized a rapid, high-resolution algorithmic method to count fluorescently labeled cells in zebrafish larvae in vivo. Using transgenic zebrafish larvae, in which neutrophils express EGFP, we captured 18 gigapixels of images across a full 96-well plate, in 75 seconds, and processed the resulting datastream, counting individual fluorescent neutrophils in all individual larvae in 5 minutes. This automation is facilitated by a machine learning segmentation algorithm that defines the most in-focus view of each larva in each well after which pixel intensity thresholding and blob detection are employed to locate and count fluorescent cells. We validated this method by comparing algorithmic neutrophil counts to manual counts in larvae subjected to changes in neutrophil numbers, demonstrating the utility of this approach for high-throughput genetic and chemical screens where a change in neutrophil number is an endpoint metric. Using the MCAM™ we have been able to, within minutes, acquire both enough data to create an automated algorithm and execute a biological experiment with statistical significance. Finally, we present this open-source software package which allows the user to train and evaluate a custom machine learning segmentation model and use it to localize zebrafish and analyze cell counts within the segmented region of interest. This software can be modified as needed for studies involving other zebrafish cell lineages using different transgenic reporter lines and can also be adapted for studies using other amenable model species.