VSVictoria V. Suchkova

Victoria V. Suchkova

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Victoria V. Suchkova has a total of 48 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Influence of Carbon Nanotube Hydrodynamic Radius on Electrical Conductivity in Photoresists

    by Mikhail S. Savelyev, Ekaterina P. Otsupko, Victoria V. Suchkova, Kristina D. Popovich, Pavel N. Vasilevsky, Sergey V. Selishchev, Alexander Yu. Gerasimenko

    Tuning the electrical properties of biocompatible materials with minimal amounts of nanofiller presents a significant challenge in neuroimplant development. This study investigates the influence of single-walled carbon nanotube (SWCNT) agglomerate size on the electrical conductivity of a bioinspired biopolymer composite. The composites were fabricated via photolithography. We analyzed the effect of ultrasonic homogenization on the size distribution of SWCNT bundles. Our results demonstrate that the degree of nanotube dispersion is critical for determining electrical conductivity. The highest conductivity was achieved with an average bundle size of 95 µm and a defect level of no more than 0.143, as measured by the ID/IG+ band ratio using Raman spectroscopy. We attribute this to the formation of an interconnected percolation network within the biopolymer matrix. These findings demonstrate a viable approach for controlling the conductive properties of bioinspired composites.

  • Open Access

    Effect of Ultrasonic Treatment of Dispersed Carbon Nanocomposite Media on the Formation, Electrical Conductivity, and Degradation of a Hydrogel for Metallic Stimulation Electrodes

    by Mikhail Savelyev, Artem Kuksin, Denis Murashko, Ekaterina Otsupko, Victoria Suchkova, Kristina Efremova, Pavel Vasilevsky, Ulyana Kurilova, Sergey Selishchev, Alexander Gerasimenko

    This study investigates the impact of ultrasonic treatment on the deagglomeration of aggregates of single-walled carbon nanotubes (SWCNTs) and reduced graphene oxide (rGO). The aim of the research is to enhance the electrical conductivity of a biopolymer hydrogel designed for coating metallic neurostimulation electrodes. Biocompatible coating materials are essential for the safe long-term function of implants within the body, enabling the transmission of nerve impulses to external devices for signal conversion and neurostimulation. Dynamic light scattering (DLS) was employed to monitor the dispersion state, in conjunction with measurements of specific electrical conductivity. The mass loss and swelling capacity were evaluated over an 80-day period to account for the effects of degradation during in vitro studies. Samples of flexible–elastic hydrogels for electrodes with complex geometry were formed by the photopolymerization of a photopolymerizable medium, similar to a photoresist. Analysis of the dependence of temperature and normalized optical transmittance on the duration of laser photopolymerization made it possible to determine the optimal polymerization temperature for the photopolymerizable medium as −28 °C. This temperature regime ensures maximum reproducibility of hydrogel formation and eliminates the presence of unpolymerized areas. The article presents a biopolymer hydrogel with SWCNTs and rGO nanoparticles in a 1:1 ratio. It was found that sufficient specific electrical conductivity is achieved using SWCNTs with a characteristic hydrodynamic radius of R = 490 nm and rGO with R = 210 nm (sample Col/BSA/CS/Eosin Y/SWCNTs (490 nm)/rGO 4). The photopolymerized hydrogel 4 demonstrated sufficient biocompatibility, exceeding the control sample by 16%. According to the results of in vitro studies over 80 days, this sample exhibited moderate degradation of 45% while retaining its swelling ability. The swelling degree decreased by 50% compared to the initial value of 170%. The presented hydrogel 4 is a promising coating material for implantable metallic neurostimulation electrodes, enhancing their stability in the physiological environment.


  • Open Access

    Application of Reduced Graphene Oxide in Biocompatible Composite for Improving Its Specific Electrical Conductivity

    by Mikhail Savelyev, Artem Kuksin, Ekaterina Otsupko, Victoria Suchkova, Kristina Popovich, Pavel Vasilevsky, Ulyana Kurilova, Sergey Selishchev, Alexander Gerasimenko

    The reduced graphene oxide (rGO) combination in association with the single-walled carbon nanotubes (SWCNTs) in a dispersion minimizes the number of carbon particles to obtain a hydrogel with the same level of specific conductivity. When developing neuroimplants intended to restore damaged neural networks or modulate pain transmission, biocompatibility and the permeability of stimulating currents are key requirements. The specific conductivity of the resulting hydrogels with the addition of different carbon nanoparticles was 19 mS/cm (1-SWCNTs), 17 mS/cm (2-rGO), and 35 mS/cm (3-SWCNTs/rGO). The results confirm the possibility of regulating the degradation time. Colorimetric assay for assessing cell metabolic activity (MTT) assay using the Neuro 2A cell line showed sufficient biocompatibility for the amount of SWCNTs and rGO used.

  • Open Access

    Modern trends in laser non-invasive reconstruction of biological tissues

    by V. V. Suchkova, D. I. Ryabkin, L. Yang, D. V. Telyshev, A. Yu. Gerasimenko

    The article focuses on contemporary methodologies for laser-based, non-invasive reconstruction of biological tissues. It examines the mechanisms of laser-tissue interaction, including photothermal processes and the formation of new molecular bonds. A range of laser systems – neodymium-doped yttriumaluminum garnet laser (Nd:YAG laser), carbon dioxide laser (CO2 laser), diode and their applications in vascular, micro- and plastic surgery are analyzed. The analysis is further enriched by a discussion of bioorganic solders, such as albumin and indocyanine green, and nanomaterials that have been shown to enhance bond strength and reduce thermal damage. Examples of successful applications of the technology for vascular and nerve repair, wound sealing, and plastic surgery are provided. Finally, future prospects are highlighted, including temperature control systems and personalized approaches. The text emphasizes the potential of laser methods as a minimally invasive alternative to traditional surgery.

  • Open Access

    Formation of Neurointerfaces Based on Electrically Conductive Biopolymers by Two-Photon Polymerization Method

    by Mikhail S. Savelyev, Artem V. Kuksin, Denis T. Murashko, Ekaterina P. Otsupko, Victoria V. Suchkova, Kristina D. Popovich, Pavel N. Vasilevsky, Yulia O. Vasilevskaya, Ulyana E. Kurilova, Elena M. Eganova, et al.

    Preventing false signals of phantom pain after limb amputation is crucial. The development of neurointerfaces capable of bidirectional information exchange between the brain and external devices, along with long-term use, is a key research priority. The main problem with existing devices lies in the potential formation of scar tissue and the death of adjacent neurons. To address this issue, a polymer composite based on new composition: chitosan, bovine serum albumin, single-walled carbon nanotubes, and Eosin Y, which was created for the fabrication of a neurointerface. A polymer composite of the required shape was formed by two-photon polymerization. In studying its nonlinear optical properties, the new effect of phase self-modulation was discovered, which is observed after exposure to laser radiation prior to the formation of the composite. The time of appearance of diffraction rings was measured. This allowed optimization of laser parameters—scanner speed and intensity. The resulting homogeneous composite exhibited a specific conductivity of 20 mS × cm−1, sufficient for electrophysiological signal transmission.


  • Comparative evaluation of tissue fusion efficacy in laser-assisted flap plasty (Experimental study)

    by K.A. Galichenko, D.I. Ryabkin, V.V. Suchkova, K.D. Blinov, S.S. Dydykin, A.L. Istranov, E.A. Gerasimenko, A.V. Igrunkova, S.P. Timoshkin, I.N. Sorokvasha, et al.

    Objective. The current study aimed to compare the quality of tissue connection in flap plastic surgery using laser exposure and a traditional surgical suture in the experiment. Material and methods. The experiment was conducted in male Wistar rats. Skin defect was modeled on the withers. The hair was removed, followed by skin excision and closure with skin flaps according to Grose and Werner method. Eighteen laboratory animals were divided into 2 groups, each group contained 9 animals: 1 — control with plastic surgery with counter flaps, performed by connecting the edges of the wound with single-row interrupted sutures, 2 — experimental with plastic surgery with counter flaps, connected with biological solder under the laser radiation. The gadget for laser connection of biological tissues was provided by the Laboratory of Biomedical Nanotechnologies of the Institute of Biomedical Systems of the National Research University. On days 7, 14 and 21, the animals were sacrificed; the tensile strength of the suture, the morphology, and cosmetic characteristics of the wound were examined. Results. Local application of laser exposure with auxiliary materials of biological solder based on bovine serum albumin, collagen, indocyanine green, single-walled carbon nanotubes, and water did not cause mortality of animals in the groups. On day 7, the tensile strength yielded to the interrupted joint and amounted to 1.8±0.2 MPa, while by day 14 it amounted to 3.2±0.5 MPa and was comparable to the interrupted suture 3.4±0.5 MPa, respectively. Regarding the cosmetic characteristics of the scar on the SCAR scale on day 21, the total score for the nodal connection with skin grafting was 4 points, while with the laser connection it was 1. Conclusions. In plastic surgery, laser connection of wound edges with opposing flaps does not yield to the nodal connection in healing time of the surgical wound and strength on day 14. Also, it reduces the area of the scar and improves the cosmetic characteristics of the postoperative region on day 21.


  • Open Access

    Laser-Formed Sensors with Electrically Conductive MWCNT Networks for Gesture Recognition Applications

    by Natalia A. Nikitina, Dmitry I. Ryabkin, Victoria V. Suchkova, Artem V. Kuksin, Evgeny S. Pyankov, Levan P. Ichkitidze, Aleksey V. Maksimkin, Evgeny P. Kitsyuk, Ekaterina A. Gerasimenko, Dmitry V. Telyshev, et al.

    Currently, an urgent need in the field of wearable electronics is the development of flexible sensors that can be attached to the human body to monitor various physiological indicators and movements. In this work, we propose a method for forming an electrically conductive network of multi-walled carbon nanotubes (MWCNT) in a matrix of silicone elastomer to make stretchable sensors sensitive to mechanical strain. The electrical conductivity and sensitivity characteristics of the sensor were improved by using laser exposure, through the effect of forming strong carbon nanotube (CNT) networks. The initial electrical resistance of the sensors obtained using laser technology was ~3 kOhm (in the absence of deformation) at a low concentration of nanotubes of 3 wt% in composition. For comparison, in a similar manufacturing process, but without laser exposure, the active material had significantly higher values of electrical resistance, which was ~19 kOhm in this case. The laser-fabricated sensors have a high tensile sensitivity (gauge factor ~10), linearity of >0.97, a low hysteresis of 2.4%, tensile strength of 963 kPa, and a fast strain response of 1 ms. The low Young’s modulus values of ~47 kPa and the high electrical and sensitivity characteristics of the sensors made it possible to fabricate a smart gesture recognition sensor system based on them, with a recognition accuracy of ~94%. Data reading and visualization were performed using the developed electronic unit based on the ATXMEGA8E5-AU microcontroller and software. The obtained results open great prospects for the application of flexible CNT sensors in intelligent wearable devices (IWDs) for medical and industrial applications.


  • Open Access

    Reconstruction of Soft Biological Tissues Using Laser Soldering Technology with Temperature Control and Biopolymer Nanocomposites

    by Alexander Yu. Gerasimenko, Elena A. Morozova, Dmitry I. Ryabkin, Alexey Fayzullin, Svetlana V. Tarasenko, Victoria V. Molodykh, Evgeny S. Pyankov, Mikhail S. Savelyev, Elena A. Sorokina, Alexander Y. Rogalsky, et al.

    Laser soldering is a current biophotonic technique for the surgical recovery of the integrity of soft tissues. This technology involves the use of a device providing laser exposure to the cut edges of the wound with a solder applied. The proposed solder consisted of an aqueous dispersion of biopolymer albumin (25 wt.%), single-walled carbon nanotubes (0.1 wt.%) and exogenous indocyanine green chromophore (0.1 wt.%). Under laser exposure, the dispersion transforms into a nanocomposite due to the absorption of radiation and its conversion into heat. The nanocomposite is a frame structure of carbon nanotubes in a biopolymer matrix, which provides adhesion of the wound edges and the formation of a strong laser weld. A new laser device based on a diode laser (808 nm) has been developed to implement the method. The device has a temperature feedback system based on a bolometric infrared matrix sensor. The system determines the hottest area of the laser weld and adjusts the current supplied to the diode laser to maintain the preset laser heating temperature. The laser soldering technology made it possible to heal linear defects (cuts) in the skin of laboratory animals (rabbits) without the formation of a fibrotic scar compared to the control (suture material). The combined use of a biopolymer nanocomposite solder and a laser device made it possible to achieve a tensile strength of the laser welds of 4 ± 0.4 MPa. The results of the experiment demonstrated that the addition of single-walled carbon nanotubes to the solder composition leads to an increase in the ultimate tensile strength of the laser welds by 80%. The analysis of regenerative and morphological features in the early stages (1–3 days) after surgery revealed small wound gaps, a decrease in inflammation, the absence of microcirculatory disorders and an earlier epithelization of laser welds compared to the control. On the 10th day after the surgical operation, the laser weld was characterized by a thin cosmetic scar and a continuous epidermis covering the defect. An immunohistochemical analysis proved the absence of myofibroblasts in the area of the laser welds.


  • Open Access

    Flexible Strain-Sensitive Silicone-CNT Sensor for Human Motion Detection

    by Natalia A. Demidenko, Artem V. Kuksin, Victoria V. Molodykh, Evgeny S. Pyankov, Levan P. Ichkitidze, Victoria A. Zaborova, Alexandr A. Tsymbal, Svetlana A. Tkachenko, Hassan Shafaei, Ekaterina Diachkova, et al.

    This article describes the manufacturing technology of biocompatible flexible strain-sensitive sensor based on Ecoflex silicone and multi-walled carbon nanotubes (MWCNT). The sensor demonstrates resistive behavior. Structural, electrical, and mechanical characteristics are compared. It is shown that laser radiation significantly reduces the resistance of the material. Through laser radiation, electrically conductive networks of MWCNT are formed in a silicone matrix. The developed sensor demonstrates highly sensitive characteristics: gauge factor at 100% elongation −4.9, gauge factor at 90° bending −0.9%/deg, stretchability up to 725%, tensile strength 0.7 MPa, modulus of elasticity at 100% 46 kPa, and the temperature coefficient of resistance in the range of 30–40 °C is −2 × 10−3. There is a linear sensor response (with 1 ms response time) with a low hysteresis of ≤3%. An electronic unit for reading and processing sensor signals based on the ATXMEGA8E5-AU microcontroller has been developed. The unit was set to operate the sensor in the range of electrical resistance 5–150 kOhm. The Bluetooth module made it possible to transfer the received data to a personal computer. Currently, in the field of wearable technologies and health monitoring, a vital need is the development of flexible sensors attached to the human body to track various indicators. By integrating the sensor with the joints of the human hand, effective movement sensing has been demonstrated.


  • Open Access

    Method for dynamic measurement of thermal diffusivity during laser soldering of biological tissues

    by D I Ryabkin, V V Molodykh, A Yu. Gerasimenko

    In this paper, we propose a method for dynamic measurement of the thermal diffusivity coefficient during laser soldering of biological tissues. The method is based on modelling the function of temperature dependence on time during cooling of biological tissue after exposure to laser radiation. The simulation is carried out by solving the heat equation for a homogeneous biological tissue and the absence of external heat sources. The desired value of the thermal diffusivity coefficient was determined by optimizing the residual functional of the temperature functions from time obtained experimentally and by solving the thermal diffusivity equation. Experiments were carried out to measure the thermal diffusivity coefficient by the proposed method for myocardial and skin tissues at maximum heating temperatures of 40, 50, 60 °C. The measured values of the thermal diffusivity coefficient for the myocardium are in the range from 2.3 to 2.7 m2/s*10-6, and for the skin from 1.5 to 1.7 m2/s*10-6.