Andrew D. Lachance
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Andrew D. Lachance has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
Jeffrey Lutton
Guthrie Robert Packer Hospital, Sayre, USA
5 shared publications- Joseph Y. Choi
Geisinger Commonwealth School of Medicine, Scranton, PA, USA
4 shared publications - Roman Steika
Department of Orthopaedic Surgery, Guthrie Clinic, Sayre, PA, USA
4 shared publications - Wonyong Lee
Department of Orthopaedic Surgery and Rehabilitation Medicine, The University of Chicago, Chicago, Illinois
4 shared publications - Frank Chessa
MaineHealth, Portland, ME, USA
3 shared publications Mason Stilwell
Guthrie Robert Packer Hospital, Sayre, USA
3 shared publications
Latest Publications
- 6 December 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 35 (5) , 1194-1200
Outcomes of modular diaphyseal vs. nonmodular metaphyseal reverse total shoulder arthroplasty stem for 3- and 4-part proximal humerus fractures
- 6 December 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 35 (5) , 1194-1200
Outcomes of modular diaphyseal vs. nonmodular metaphyseal reverse total shoulder arthroplasty stem for 3- and 4-part proximal humerus fractures
- 1 October 2025
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 15 (4)
Distal Femur Fracture Above a High Below-The-Knee Amputation Managed With Lateral Locking Plate
Case: We report the case of a patient with a below-the-knee amputation who sustained a complex femur fracture ipsilateral to his residual limb after a fall from height. His fracture was managed with a lateral locking plate of the distal femur for fixation. He was followed for 16 months; at 7 months, he demonstrated return to pretrauma functional status. Conclusion: Fixation of the distal femur with a lateral locking plate did not interfere with the patient's ability to wear a prosthesis and should be considered for managing “periprosthetic” femur fractures in those with a below-the-knee amputation to maintain prosthetic usage.
- 1 October 2025
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 15 (4)
Distal Femur Fracture Above a High Below-The-Knee Amputation Managed With Lateral Locking Plate
Case: We report the case of a patient with a below-the-knee amputation who sustained a complex femur fracture ipsilateral to his residual limb after a fall from height. His fracture was managed with a lateral locking plate of the distal femur for fixation. He was followed for 16 months; at 7 months, he demonstrated return to pretrauma functional status. Conclusion: Fixation of the distal femur with a lateral locking plate did not interfere with the patient's ability to wear a prosthesis and should be considered for managing “periprosthetic” femur fractures in those with a below-the-knee amputation to maintain prosthetic usage.
- Open Access
- 1 June 2025
- Published by Korean Shoulder and Elbow Society in Clinics in Shoulder and Elbow
- Vol. 28 (2) , 196-203
Five-year clinical outcomes of metal-backed, hybrid, and polyethylene glenoid components in total shoulder arthroplasty
Background: The glenoid components in total shoulder arthroplasty (TSA) are numerous and have both advantages and disadvantages. This study aimed to compare 5-year functional outcomes, patient-reported outcomes, and conversion rates between patients who underwent TSA using metal-backed glenoid (MBG), hybrid, and all-polyethylene glenoid components. Methods: The patients who were eligible for this study were retrospectively identified using electronic health records. The subjects underwent TSA performed by a fellowship-trained attending physician from November 2017 to December 2018 at a single institution. The inclusion criteria from 5-year follow-up data were adult-age patients (≥18 years old) who underwent TSA using MBG, hybrid, or all-polyethylene glenoid components. Results: A total of 77 patients was included: 44 patients with all-polyethylene glenoid components, 17 with hybrid glenoid components, and 16 with MBG components. The mean patient age was 66.9 years, with the all-polyethylene patients being significantly younger (P<0.001). The all-polyethylene glenoid patients experienced a significantly longer operative time at 120 minutes (P=0.005) compared to those with other components. At the 5-year follow-up, no significant difference was shown in American Shoulder and Elbow Surgeons (ASES) and visual analog scale scores. However, a trend was evident in which the all-polyethylene patients had lower ASES scores (all polyethylene 87.0 vs. hybrid 100.0 vs. 97.0 MBG, P=0.086). The hybrid components tended to require revision more often at 12% vs. 6.8% of polyethylene glenoid vs. 0% of MBGs (P=0.310). No dislocation was reported, and only two complications occurred, both in the all-polyethylene group (P=0.387). Conclusions: At 5-year follow-up, patient-reported outcomes were similar when utilizing MBG, all-polyethylene, and hybrid glenoid components. Given the similar outcomes, MBGs and hybrid glenoid components could be considered favorable or preferred for potential surgical ease in a revision setting with conversion to reverse TSA. Level of evidence: III.
- 1 June 2025
- Published by Korean Shoulder and Elbow Society in Clinics in Shoulder and Elbow
- Vol. 28 (2) , 196-203
Open AccessFive-year clinical outcomes of metal-backed, hybrid, and polyethylene glenoid components in total shoulder arthroplasty
Background: The glenoid components in total shoulder arthroplasty (TSA) are numerous and have both advantages and disadvantages. This study aimed to compare 5-year functional outcomes, patient-reported outcomes, and conversion rates between patients who underwent TSA using metal-backed glenoid (MBG), hybrid, and all-polyethylene glenoid components. Methods: The patients who were eligible for this study were retrospectively identified using electronic health records. The subjects underwent TSA performed by a fellowship-trained attending physician from November 2017 to December 2018 at a single institution. The inclusion criteria from 5-year follow-up data were adult-age patients (≥18 years old) who underwent TSA using MBG, hybrid, or all-polyethylene glenoid components. Results: A total of 77 patients was included: 44 patients with all-polyethylene glenoid components, 17 with hybrid glenoid components, and 16 with MBG components. The mean patient age was 66.9 years, with the all-polyethylene patients being significantly younger (P<0.001). The all-polyethylene glenoid patients experienced a significantly longer operative time at 120 minutes (P=0.005) compared to those with other components. At the 5-year follow-up, no significant difference was shown in American Shoulder and Elbow Surgeons (ASES) and visual analog scale scores. However, a trend was evident in which the all-polyethylene patients had lower ASES scores (all polyethylene 87.0 vs. hybrid 100.0 vs. 97.0 MBG, P=0.086). The hybrid components tended to require revision more often at 12% vs. 6.8% of polyethylene glenoid vs. 0% of MBGs (P=0.310). No dislocation was reported, and only two complications occurred, both in the all-polyethylene group (P=0.387). Conclusions: At 5-year follow-up, patient-reported outcomes were similar when utilizing MBG, all-polyethylene, and hybrid glenoid components. Given the similar outcomes, MBGs and hybrid glenoid components could be considered favorable or preferred for potential surgical ease in a revision setting with conversion to reverse TSA. Level of evidence: III.
- 28 March 2025
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 107 (9) , 1034-1039
Total Ankle Arthroplasty in Obese Patients: An Ethical Analysis
- 28 March 2025
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 107 (9) , 1034-1039
Total Ankle Arthroplasty in Obese Patients: An Ethical Analysis
- Open Access
- 21 January 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-6
Robotic assisted TKA may allow for smaller polyethylene liner sizes compared to manual TKA with simultaneous removal of Hardware
Total knee arthroplasty (TKA) with hardware around the knee is a challenge to preserve bone while boney landmarks are distorted. Robotic assisted (RA) TKA may assist in simultaneous hardware removal and TKA due to preoperative planning and retention of bone. The aim of this study is to identify if there are differences in component fixation, component constraint and functional outcomes dependent during simultaneous removal of hardware (ROH) around the knee and TKA comparing RA-TKA to manual. A retrospective chart review was performed on patients undergoing simultaneous ROH and TKA over a 10-year period at a single institution. Patients were required to have at least 6 months of follow up. Data extracted included surgical technique, demographics, range of motion (ROM) at 1 year, complications, need for augments and utilization of revision components. There were a total of 31 simultaneous ROH and TKA found in the EMR that met inclusion criteria including 23 manual and 8 RA-TKA with ROH. RA-TKA patients had significantly smaller poly sizes (p = 0.017). There was a trend for decreased need for augments (p = 0.544) and stems (p = 0.315) in the RA-TKA group although this was not statistically significant. Postoperative flexion (p = 0.973) or extension (p = 0.351) at 1 year did not vary. Notably, one patient in the manual revision group required a hinged knee, and one manual patient required an MUA. Patients undergoing ROH and RA-TKA had a statistically significant decrease in poly size with a trend of less revision component utilization. RA may allow for more boney preservation via CT guided preoperative planning and precise boney cuts.
- 21 January 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-6
Open AccessRobotic assisted TKA may allow for smaller polyethylene liner sizes compared to manual TKA with simultaneous removal of Hardware
Total knee arthroplasty (TKA) with hardware around the knee is a challenge to preserve bone while boney landmarks are distorted. Robotic assisted (RA) TKA may assist in simultaneous hardware removal and TKA due to preoperative planning and retention of bone. The aim of this study is to identify if there are differences in component fixation, component constraint and functional outcomes dependent during simultaneous removal of hardware (ROH) around the knee and TKA comparing RA-TKA to manual. A retrospective chart review was performed on patients undergoing simultaneous ROH and TKA over a 10-year period at a single institution. Patients were required to have at least 6 months of follow up. Data extracted included surgical technique, demographics, range of motion (ROM) at 1 year, complications, need for augments and utilization of revision components. There were a total of 31 simultaneous ROH and TKA found in the EMR that met inclusion criteria including 23 manual and 8 RA-TKA with ROH. RA-TKA patients had significantly smaller poly sizes (p = 0.017). There was a trend for decreased need for augments (p = 0.544) and stems (p = 0.315) in the RA-TKA group although this was not statistically significant. Postoperative flexion (p = 0.973) or extension (p = 0.351) at 1 year did not vary. Notably, one patient in the manual revision group required a hinged knee, and one manual patient required an MUA. Patients undergoing ROH and RA-TKA had a statistically significant decrease in poly size with a trend of less revision component utilization. RA may allow for more boney preservation via CT guided preoperative planning and precise boney cuts.
- Open Access
- 19 September 2024
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 5 (2) , 216-221
Ethical considerations in shoulder arthroplasty in patients who are obese
- 19 September 2024
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 5 (2) , 216-221
Open AccessEthical considerations in shoulder arthroplasty in patients who are obese
- 6 August 2024
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 144 (8) , 3565-3571
Suction drain usage has no benefit following revision total hip and knee arthroplasty
Introduction The use of drains after primary total joint arthroplasty (TJA) has shown little benefit. Few studies have investigated drain usage after revision TJA. The purpose of this study was to determine whether utilizing suction drains is beneficial for patients undergoing revision arthroplasty. Materials and methods We performed a comprehensive literature review utilizing the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines from the PubMed, Embase, Web of Science, and Cochrane Library. Inclusion criteria of this review were all original articles written in English investigating the efficacy and safety of closed suction drainage in revision TKA or THA, reporting at least one of the following outcome measures: (1) estimated blood loss (EBL), (2) perioperative hemoglobin change, (3) needs for transfusion, (4) postoperative infection, and (5) wound complications. Articles were excluded if they are not available in English or they included case reports, systematic reviews, comments, editorials, surveys, or animal studies prior to July 22, 2023. A total of six studies met inclusion criteria. In total, 655 patients had a drain while 1765 patients did not have a drain after revision total hip or knee arthroplasty. Primary outcomes included for meta-analysis included estimated blood loss (EBL), postoperative hemoglobin, need for transfusion. Other data extracted includes postoperative infections, and wound complications. Results Six studies met the inclusion criteria. In total, 655 patients had drains, while 1765 patients did not after revision total hip or knee arthroplasty. The average age of the patients was 66.1+/- 3.4 years, and the average BMI was 30.3 +/-0.8. There was no difference in postoperative infections (p = 0.14), wound complications (p = 0.621) or need for transfusion (p = 0.521) between the two groups. There was also no difference in EBL (Hedges’ g CI[-3.52, 2.77]) or postoperative Hb (Hedges’ g CI[-1.65, 2.41]) between patients with and without drains. Conclusions Our results do not show any benefit from drain placement after revision total hip or knee arthroplasty. With the increased cost, time and need for drain removal, this is likely an unnecessary intervention. Level of evidence Level III, systematic review and meta-analysis.
- 6 August 2024
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 144 (8) , 3565-3571
Suction drain usage has no benefit following revision total hip and knee arthroplasty
Introduction The use of drains after primary total joint arthroplasty (TJA) has shown little benefit. Few studies have investigated drain usage after revision TJA. The purpose of this study was to determine whether utilizing suction drains is beneficial for patients undergoing revision arthroplasty. Materials and methods We performed a comprehensive literature review utilizing the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines from the PubMed, Embase, Web of Science, and Cochrane Library. Inclusion criteria of this review were all original articles written in English investigating the efficacy and safety of closed suction drainage in revision TKA or THA, reporting at least one of the following outcome measures: (1) estimated blood loss (EBL), (2) perioperative hemoglobin change, (3) needs for transfusion, (4) postoperative infection, and (5) wound complications. Articles were excluded if they are not available in English or they included case reports, systematic reviews, comments, editorials, surveys, or animal studies prior to July 22, 2023. A total of six studies met inclusion criteria. In total, 655 patients had a drain while 1765 patients did not have a drain after revision total hip or knee arthroplasty. Primary outcomes included for meta-analysis included estimated blood loss (EBL), postoperative hemoglobin, need for transfusion. Other data extracted includes postoperative infections, and wound complications. Results Six studies met the inclusion criteria. In total, 655 patients had drains, while 1765 patients did not after revision total hip or knee arthroplasty. The average age of the patients was 66.1+/- 3.4 years, and the average BMI was 30.3 +/-0.8. There was no difference in postoperative infections (p = 0.14), wound complications (p = 0.621) or need for transfusion (p = 0.521) between the two groups. There was also no difference in EBL (Hedges’ g CI[-3.52, 2.77]) or postoperative Hb (Hedges’ g CI[-1.65, 2.41]) between patients with and without drains. Conclusions Our results do not show any benefit from drain placement after revision total hip or knee arthroplasty. With the increased cost, time and need for drain removal, this is likely an unnecessary intervention. Level of evidence Level III, systematic review and meta-analysis.
- 5 June 2024
- Published by Elsevier in Foot and Ankle Surgery
- Vol. 30 (8) , 621-629
The comparison of postoperative outcomes in Morton's neuroma excision between plantar versus dorsal approach: A systematic review and meta-analysis
- 5 June 2024
- Published by Elsevier in Foot and Ankle Surgery
- Vol. 30 (8) , 621-629
The comparison of postoperative outcomes in Morton's neuroma excision between plantar versus dorsal approach: A systematic review and meta-analysis
- Open Access
- 3 June 2024
- Published by Wolters Kluwer Health in Techniques in Orthopaedics
- Vol. 39 (4) , 95-99
Management of Unstable Pediatric Distal Radius Fractures With a 2-Pin External Fixator and a Short Arm Cast: Technique and Case Series
Introduction: Pediatric distal radius fractures that are unacceptably aligned and undergo closed reduction are often redisplaced when immobilized in a cast alone without additional fixation. Percutaneous pinning, plate and screw fixation, and 4-pin wrist joint and physis-spanning external fixation constructs have previously been described to achieve and maintain reduction. Technique and Results: We successfully treated and followed 12 consecutive pediatric patients presenting with malaligned, nonphyseal distal radius fractures that were reduced and held with a 2-pin external fixation construct that did not extend distal to the physis, supplemented by a short arm cast. No complications were encountered in this series of patients. Conclusion: Two-pin external fixation is an alternative solution for completely displaced or markedly angulated pediatric distal radius fractures.
- 3 June 2024
- Published by Wolters Kluwer Health in Techniques in Orthopaedics
- Vol. 39 (4) , 95-99
Open AccessManagement of Unstable Pediatric Distal Radius Fractures With a 2-Pin External Fixator and a Short Arm Cast: Technique and Case Series
Introduction: Pediatric distal radius fractures that are unacceptably aligned and undergo closed reduction are often redisplaced when immobilized in a cast alone without additional fixation. Percutaneous pinning, plate and screw fixation, and 4-pin wrist joint and physis-spanning external fixation constructs have previously been described to achieve and maintain reduction. Technique and Results: We successfully treated and followed 12 consecutive pediatric patients presenting with malaligned, nonphyseal distal radius fractures that were reduced and held with a 2-pin external fixation construct that did not extend distal to the physis, supplemented by a short arm cast. No complications were encountered in this series of patients. Conclusion: Two-pin external fixation is an alternative solution for completely displaced or markedly angulated pediatric distal radius fractures.