Benjamin Bube
Research Subjects
Benjamin Bube has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Ana María Lara Palma
University of Burgos
3 shared publications - Bruno Baruque
Universidad de Burgos
3 shared publications Heinrich Georg Klocke
1 shared publication- Heinrich Georg Klocke
TH Kln University, Spain
1 shared publication - Heinrich Klocke
Faculty of Computer Science and Engineering Science, University of Applied Sciences Cologne, Gummersbach, Germany
1 shared publication
Latest Publications
- Open Access
- 6 September 2022
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 10 (9) , e35727
Wearable Devices in Diving: Scoping Review
Background: Wearables and their benefits for the safety and well-being of users have been widely studied and have had an enormous impact on the general development of these kinds of devices. Yet, the extent of research into the use and impact of wearable devices in the underwater environment is comparatively low. In the past 15 years, there has been an increased interest in research into wearables that are used underwater, as the use of such wearables has steadily grown over time. However, there has so far been no clear indication in the literature about the direction in which efforts for the design and construction of underwater wearable devices are developing. Therefore, the analysis presented in this scoping review establishes a good and powerful basis for the further development and orientation of current underwater wearables within the field. Objective: In this scoping review, we targeted wearable devices for underwater use to make a comprehensive map of their capabilities and features and discuss the general direction of the development of underwater wearables and the orientation of research into novel prototypes of these kinds of devices. Methods: In September 2021, we conducted an extensive search for existing literature on 4 databases and for grey literature to identify developed prototypes and early-stage products that were described and tested in water, could be worn and interacted with (eg, displays, buttons, etc), and were fully functional without external equipment. The studies were written in English, came from peer-reviewed academic sources, and were published between 2005 and 2021. We reviewed each title and The data extraction process was carried out by one author and verified by another author. Results: In total, 36 relevant studies were included. Among these, 4 different categories were identified; 18 studies dealt primarily with safety devices, 9 dealt with underwater communication devices, 7 dealt with head-up displays, and 2 dealt with underwater human-computer interaction approaches. Although the safety devices seemed to have gained the most interest at the time of this study, a clear trend toward underwater communication wearables was identified. Conclusions: This review sought to provide a first insight into the possibilities and challenges of the technologies that have been used in and for wearable devices that are meant for use in the underwater environment. Among these, underwater communication technologies have had the most significant influence on future developments. Moreover, a topic that has not received enough attention but should be further addressed is human-computer interaction. By developing underwater wearables that cover 2 or more of the technology categories that we identified, the extent of the benefits of such devices can be significantly increased in the future.
- 6 September 2022
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 10 (9) , e35727
Open AccessWearable Devices in Diving: Scoping Review
Background: Wearables and their benefits for the safety and well-being of users have been widely studied and have had an enormous impact on the general development of these kinds of devices. Yet, the extent of research into the use and impact of wearable devices in the underwater environment is comparatively low. In the past 15 years, there has been an increased interest in research into wearables that are used underwater, as the use of such wearables has steadily grown over time. However, there has so far been no clear indication in the literature about the direction in which efforts for the design and construction of underwater wearable devices are developing. Therefore, the analysis presented in this scoping review establishes a good and powerful basis for the further development and orientation of current underwater wearables within the field. Objective: In this scoping review, we targeted wearable devices for underwater use to make a comprehensive map of their capabilities and features and discuss the general direction of the development of underwater wearables and the orientation of research into novel prototypes of these kinds of devices. Methods: In September 2021, we conducted an extensive search for existing literature on 4 databases and for grey literature to identify developed prototypes and early-stage products that were described and tested in water, could be worn and interacted with (eg, displays, buttons, etc), and were fully functional without external equipment. The studies were written in English, came from peer-reviewed academic sources, and were published between 2005 and 2021. We reviewed each title and The data extraction process was carried out by one author and verified by another author. Results: In total, 36 relevant studies were included. Among these, 4 different categories were identified; 18 studies dealt primarily with safety devices, 9 dealt with underwater communication devices, 7 dealt with head-up displays, and 2 dealt with underwater human-computer interaction approaches. Although the safety devices seemed to have gained the most interest at the time of this study, a clear trend toward underwater communication wearables was identified. Conclusions: This review sought to provide a first insight into the possibilities and challenges of the technologies that have been used in and for wearable devices that are meant for use in the underwater environment. Among these, underwater communication technologies have had the most significant influence on future developments. Moreover, a topic that has not received enough attention but should be further addressed is human-computer interaction. By developing underwater wearables that cover 2 or more of the technology categories that we identified, the extent of the benefits of such devices can be significantly increased in the future.
- Open Access
- 7 January 2022
- Published by JMIR Publications Inc. in JMIR Preprints
Wearable devices in diving: A systematic review (Preprint)
BACKGROUND Wearable devices have grown enormously in importance in recent years. While wearables have generally been well studied, they have not yet been discussed in the underwater environment. OBJECTIVE The reason for this systematic review was to systematically search for the wearables for underwater operation used in the scientific literature, to make a comprehensive map of their capabilities and features, and to discuss the general direction of development. METHODS In September 2021, we conducted an extensively search of existing literature in the largest databases using keywords. For this purpose, only articles were used that contained a wearable or device that can be used in diving. Only articles in English were considered, as well as peer-reviewed articles. RESULTS In the 36 relevant studies that were found, four device categories could be identified: safety devices, underwater communication devices, head-up displays and underwater human-computer interaction devices. CONCLUSIONS The possibilities and challenges of the respective technologies were considered and evaluated separately. Underwater communication has the most significant influence on future developments. Another topic that has not received enough attention is human-computer interaction.
- 7 January 2022
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessWearable devices in diving: A systematic review (Preprint)
BACKGROUND Wearable devices have grown enormously in importance in recent years. While wearables have generally been well studied, they have not yet been discussed in the underwater environment. OBJECTIVE The reason for this systematic review was to systematically search for the wearables for underwater operation used in the scientific literature, to make a comprehensive map of their capabilities and features, and to discuss the general direction of development. METHODS In September 2021, we conducted an extensively search of existing literature in the largest databases using keywords. For this purpose, only articles were used that contained a wearable or device that can be used in diving. Only articles in English were considered, as well as peer-reviewed articles. RESULTS In the 36 relevant studies that were found, four device categories could be identified: safety devices, underwater communication devices, head-up displays and underwater human-computer interaction devices. CONCLUSIONS The possibilities and challenges of the respective technologies were considered and evaluated separately. Underwater communication has the most significant influence on future developments. Another topic that has not received enough attention is human-computer interaction.
- 26 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Consumer Electronics Magazine
- Vol. 11 (5) , 94-100
Wearable Freedive Computer With Acoustic Communication
The spread and performance of freedivers have increased enormously in recent years. In addition to the ever-increasing depth, diving time also increases. Due to this, even relative beginners dive into depths in the no longer visible area. Regardless of the depth or duration of the dive, the freediver needs to be continuously monitored so that the safety freediver can react quickly. To address this problem, we present a prototype that we call Wearable apnea divecomputer with acoustic communication (WADAC). The device collects and displays basic data about a dive, is easily expandable and enables digital underwater communication between several of them. At the time of writing this contribution, the data that can be transmitted consists on depth, time, heart rate and temperature. The prototype is waterproof to 250 m and enables a data transmission range of 200 m regardless of direction. Results from tests in the water with the help of a subsequent Usability Evaluation Questionnaire (UEQ) showed, based on 14 subjects, that the interest and novelty towards the WADAC compared with 452 other products is significant.
- 26 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Consumer Electronics Magazine
- Vol. 11 (5) , 94-100
Wearable Freedive Computer With Acoustic Communication
The spread and performance of freedivers have increased enormously in recent years. In addition to the ever-increasing depth, diving time also increases. Due to this, even relative beginners dive into depths in the no longer visible area. Regardless of the depth or duration of the dive, the freediver needs to be continuously monitored so that the safety freediver can react quickly. To address this problem, we present a prototype that we call Wearable apnea divecomputer with acoustic communication (WADAC). The device collects and displays basic data about a dive, is easily expandable and enables digital underwater communication between several of them. At the time of writing this contribution, the data that can be transmitted consists on depth, time, heart rate and temperature. The prototype is waterproof to 250 m and enables a data transmission range of 200 m regardless of direction. Results from tests in the water with the help of a subsequent Usability Evaluation Questionnaire (UEQ) showed, based on 14 subjects, that the interest and novelty towards the WADAC compared with 452 other products is significant.