Emily N. Boice
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Emily N. Boice has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Eric J. Snider
Expeditionary Medical Systems Department, U.S. Army Institute of Surgical Research, JBSA Fort Sam Houston, San Antonio, TX 78234, USA
14 shared publications - Sofia I. Hernandez Torres
U.S. Army Institute of Surgical Research, JBSA Fort Sam Houston, San Antonio, TX 78234, USA
10 shared publications - David Berard
Organ Support and Automation Technologies Group, U.S. Army Institute of Surgical Research, JBSA Fort Sam Houston, San Antonio, TX 78234, USA
9 shared publications - Guy Avital
Israel Defense Forces Medical Corps, Ramat Gan, Israel
9 shared publications - Saul J. Vega
U.S. Army Institute of Surgical Research, JBSA Fort Sam Houston, San Antonio, TX 78234, USA
5 shared publications - Charles F. Schwarten
Air Force Research Laboratory, Joint Base San Antonio, Fort Sam Houston, Texas, United States
2 shared publications
Latest Publications
- Open Access
- 11 February 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31  (05) , 1-18
Corneal dose response from exposure to a Q-switched laser at a central wavelength of 1645 nm using a rabbit model
SignificanceLaser safety studies of the eye are well documented for visible wavelength and continuous wave lasers. There are fewer experimental results for infrared wavelengths and pulsed lasers.AimWe aim to fill the gap at 1645 nm for single nanosecond pulse duration exposures of rabbit cornea and determine the threshold radiant exposure to generate lesions 50% of the time (estimated dose ED50).ApproachImages of the cornea during exposures were acquired using slit lamp microscopy and optical coherence tomography. A histological analysis helped provide dosimetry relationships with morphology and mechanisms of the damage.ResultsWe measured the energy ED50 value at 3.86±0.085 mJ utilizing the slit lamp biomicroscopy. Incorporating the experimental spot size diameter, this corresponds to a peak radiant exposure of 102 J/cm2. By contrast, the average radiant exposure ED50 over a 1-mm diameter limiting aperture as per the ANSI Z.136 convention was 0.49 J/cm2. Additional analysis via optical coherence tomography (OCT) and histology examined the severity and degree of damage.ConclusionThis experimental approach performed well to characterize damage and identify damage thresholds to inform the laser safety standard community of the accuracy of current exposure limits.
- 11 February 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31  (05) , 1-18
Open AccessCorneal dose response from exposure to a Q-switched laser at a central wavelength of 1645 nm using a rabbit model
SignificanceLaser safety studies of the eye are well documented for visible wavelength and continuous wave lasers. There are fewer experimental results for infrared wavelengths and pulsed lasers.AimWe aim to fill the gap at 1645 nm for single nanosecond pulse duration exposures of rabbit cornea and determine the threshold radiant exposure to generate lesions 50% of the time (estimated dose ED50).ApproachImages of the cornea during exposures were acquired using slit lamp microscopy and optical coherence tomography. A histological analysis helped provide dosimetry relationships with morphology and mechanisms of the damage.ResultsWe measured the energy ED50 value at 3.86±0.085 mJ utilizing the slit lamp biomicroscopy. Incorporating the experimental spot size diameter, this corresponds to a peak radiant exposure of 102 J/cm2. By contrast, the average radiant exposure ED50 over a 1-mm diameter limiting aperture as per the ANSI Z.136 convention was 0.49 J/cm2. Additional analysis via optical coherence tomography (OCT) and histology examined the severity and degree of damage.ConclusionThis experimental approach performed well to characterize damage and identify damage thresholds to inform the laser safety standard community of the accuracy of current exposure limits.
- 4 December 2025
- Published by Laser Institute of America in Journal of Laser Applications
- Vol. 38  (1)
Retinal dose response from exposure to the supercontinuum generated by a near-infrared femtosecond laser
Ultrashort pulse lasers are currently used in a variety of applications, including laser eye surgery. The 2022 revision to the American National Standards Institute laser safety standards includes maximum permissible exposures for pulses as short as 100 femtoseconds at ultraviolet, visible, and infrared wavelengths. However, the ocular laser safety standards do not consider nonlinear optical effects resulting from the interaction of ocular tissues with femtosecond pulses. The generation of broadband white light, or supercontinuum, is one example of a nonlinear optical effect resulting from the interaction of a femtosecond pulse with water. We have demonstrated supercontinuum generation within the eye of anesthetized porcine subjects and reported the median effective dose for laser-induced in vivo retinal damage from the supercontinuum generated by single femtosecond pulses at central wavelengths of 1325 and 1350 nm. We used a single near-infrared femtosecond pulse to determine the pulse energies that generated a supercontinuum within the eye and resulted in retinal alterations. We are now in a position to report our result for 1375 nm and on the histological analysis of the injuries. The results of this study will inform the laser safety standards’ community about hazards to the eye due to the supercontinuum generated by nonlinear effects in the aqueous media of the eye.
- 4 December 2025
- Published by Laser Institute of America in Journal of Laser Applications
- Vol. 38  (1)
Retinal dose response from exposure to the supercontinuum generated by a near-infrared femtosecond laser
Ultrashort pulse lasers are currently used in a variety of applications, including laser eye surgery. The 2022 revision to the American National Standards Institute laser safety standards includes maximum permissible exposures for pulses as short as 100 femtoseconds at ultraviolet, visible, and infrared wavelengths. However, the ocular laser safety standards do not consider nonlinear optical effects resulting from the interaction of ocular tissues with femtosecond pulses. The generation of broadband white light, or supercontinuum, is one example of a nonlinear optical effect resulting from the interaction of a femtosecond pulse with water. We have demonstrated supercontinuum generation within the eye of anesthetized porcine subjects and reported the median effective dose for laser-induced in vivo retinal damage from the supercontinuum generated by single femtosecond pulses at central wavelengths of 1325 and 1350 nm. We used a single near-infrared femtosecond pulse to determine the pulse energies that generated a supercontinuum within the eye and resulted in retinal alterations. We are now in a position to report our result for 1375 nm and on the histological analysis of the injuries. The results of this study will inform the laser safety standards’ community about hazards to the eye due to the supercontinuum generated by nonlinear effects in the aqueous media of the eye.
- Open Access
- 2 October 2022
- Published by MDPI AG in Journal of Imaging
- Vol. 8  (10) , 270
Using an Ultrasound Tissue Phantom Model for Hybrid Training of Deep Learning Models for Shrapnel Detection
Tissue phantoms are important for medical research to reduce the use of animal or human tissue when testing or troubleshooting new devices or technology. Development of machine-learning detection tools that rely on large ultrasound imaging data sets can potentially be streamlined with high quality phantoms that closely mimic important features of biological tissue. Here, we demonstrate how an ultrasound-compliant tissue phantom comprised of multiple layers of gelatin to mimic bone, fat, and muscle tissue types can be used for machine-learning training. This tissue phantom has a heterogeneous composition to introduce tissue level complexity and subject variability in the tissue phantom. Various shrapnel types were inserted into the phantom for ultrasound imaging to supplement swine shrapnel image sets captured for applications such as deep learning algorithms. With a previously developed shrapnel detection algorithm, blind swine test image accuracy reached more than 95% accuracy when training was comprised of 75% tissue phantom images, with the rest being swine images. For comparison, a conventional MobileNetv2 deep learning model was trained with the same training image set and achieved over 90% accuracy in swine predictions. Overall, the tissue phantom demonstrated high performance for developing deep learning models for ultrasound image classification.
- 2 October 2022
- Published by MDPI AG in Journal of Imaging
- Vol. 8  (10) , 270
Open AccessUsing an Ultrasound Tissue Phantom Model for Hybrid Training of Deep Learning Models for Shrapnel Detection
Tissue phantoms are important for medical research to reduce the use of animal or human tissue when testing or troubleshooting new devices or technology. Development of machine-learning detection tools that rely on large ultrasound imaging data sets can potentially be streamlined with high quality phantoms that closely mimic important features of biological tissue. Here, we demonstrate how an ultrasound-compliant tissue phantom comprised of multiple layers of gelatin to mimic bone, fat, and muscle tissue types can be used for machine-learning training. This tissue phantom has a heterogeneous composition to introduce tissue level complexity and subject variability in the tissue phantom. Various shrapnel types were inserted into the phantom for ultrasound imaging to supplement swine shrapnel image sets captured for applications such as deep learning algorithms. With a previously developed shrapnel detection algorithm, blind swine test image accuracy reached more than 95% accuracy when training was comprised of 75% tissue phantom images, with the rest being swine images. For comparison, a conventional MobileNetv2 deep learning model was trained with the same training image set and achieved over 90% accuracy in swine predictions. Overall, the tissue phantom demonstrated high performance for developing deep learning models for ultrasound image classification.
- Open Access
- 19 September 2022
- Published by MDPI AG in Journal of Imaging
- Vol. 8  (9) , 252
Evaluation of an Object Detection Algorithm for Shrapnel and Development of a Triage Tool to Determine Injury Severity
Emergency medicine in austere environments rely on ultrasound imaging as an essential diagnostic tool. Without extensive training, identifying abnormalities such as shrapnel embedded in tissue, is challenging. Medical professionals with appropriate expertise are limited in resource-constrained environments. Incorporating artificial intelligence models to aid the interpretation can reduce the skill gap, enabling identification of shrapnel, and its proximity to important anatomical features for improved medical treatment. Here, we apply a deep learning object detection framework, YOLOv3, for shrapnel detection in various sizes and locations with respect to a neurovascular bundle. Ultrasound images were collected in a tissue phantom containing shrapnel, vein, artery, and nerve features. The YOLOv3 framework, classifies the object types and identifies the location. In the testing dataset, the model was successful at identifying each object class, with a mean Intersection over Union and average precision of 0.73 and 0.94, respectively. Furthermore, a triage tool was developed to quantify shrapnel distance from neurovascular features that could notify the end user when a proximity threshold is surpassed, and, thus, may warrant evacuation or surgical intervention. Overall, object detection models such as this will be vital to compensate for lack of expertise in ultrasound interpretation, increasing its availability for emergency and military medicine.
- 19 September 2022
- Published by MDPI AG in Journal of Imaging
- Vol. 8  (9) , 252
Open AccessEvaluation of an Object Detection Algorithm for Shrapnel and Development of a Triage Tool to Determine Injury Severity
Emergency medicine in austere environments rely on ultrasound imaging as an essential diagnostic tool. Without extensive training, identifying abnormalities such as shrapnel embedded in tissue, is challenging. Medical professionals with appropriate expertise are limited in resource-constrained environments. Incorporating artificial intelligence models to aid the interpretation can reduce the skill gap, enabling identification of shrapnel, and its proximity to important anatomical features for improved medical treatment. Here, we apply a deep learning object detection framework, YOLOv3, for shrapnel detection in various sizes and locations with respect to a neurovascular bundle. Ultrasound images were collected in a tissue phantom containing shrapnel, vein, artery, and nerve features. The YOLOv3 framework, classifies the object types and identifies the location. In the testing dataset, the model was successful at identifying each object class, with a mean Intersection over Union and average precision of 0.73 and 0.94, respectively. Furthermore, a triage tool was developed to quantify shrapnel distance from neurovascular features that could notify the end user when a proximity threshold is surpassed, and, thus, may warrant evacuation or surgical intervention. Overall, object detection models such as this will be vital to compensate for lack of expertise in ultrasound interpretation, increasing its availability for emergency and military medicine.
- Open Access
- 11 September 2022
- Published by MDPI AG in Journal of Imaging
- Vol. 8  (9) , 249
Training Ultrasound Image Classification Deep-Learning Algorithms for Pneumothorax Detection Using a Synthetic Tissue Phantom Apparatus
Ultrasound (US) imaging is a critical tool in emergency and military medicine because of its portability and immediate nature. However, proper image interpretation requires skill, limiting its utility in remote applications for conditions such as pneumothorax (PTX) which requires rapid intervention. Artificial intelligence has the potential to automate ultrasound image analysis for various pathophysiological conditions. Training models require large data sets and a means of troubleshooting in real-time for ultrasound integration deployment, and they also require large animal models or clinical testing. Here, we detail the development of a dynamic synthetic tissue phantom model for PTX and its use in training image classification algorithms. The model comprises a synthetic gelatin phantom cast in a custom 3D-printed rib mold and a lung mimicking phantom. When compared to PTX images acquired in swine, images from the phantom were similar in both PTX negative and positive mimicking scenarios. We then used a deep learning image classification algorithm, which we previously developed for shrapnel detection, to accurately predict the presence of PTX in swine images by only training on phantom image sets, highlighting the utility for a tissue phantom for AI applications.
- 11 September 2022
- Published by MDPI AG in Journal of Imaging
- Vol. 8  (9) , 249
Open AccessTraining Ultrasound Image Classification Deep-Learning Algorithms for Pneumothorax Detection Using a Synthetic Tissue Phantom Apparatus
Ultrasound (US) imaging is a critical tool in emergency and military medicine because of its portability and immediate nature. However, proper image interpretation requires skill, limiting its utility in remote applications for conditions such as pneumothorax (PTX) which requires rapid intervention. Artificial intelligence has the potential to automate ultrasound image analysis for various pathophysiological conditions. Training models require large data sets and a means of troubleshooting in real-time for ultrasound integration deployment, and they also require large animal models or clinical testing. Here, we detail the development of a dynamic synthetic tissue phantom model for PTX and its use in training image classification algorithms. The model comprises a synthetic gelatin phantom cast in a custom 3D-printed rib mold and a lung mimicking phantom. When compared to PTX images acquired in swine, images from the phantom were similar in both PTX negative and positive mimicking scenarios. We then used a deep learning image classification algorithm, which we previously developed for shrapnel detection, to accurately predict the presence of PTX in swine images by only training on phantom image sets, highlighting the utility for a tissue phantom for AI applications.
- Open Access
- 27 August 2022
- Published by MDPI AG in Bioengineering
- Vol. 9  (9) , 420
Hardware-in-Loop Comparison of Physiological Closed-Loop Controllers for the Autonomous Management of Hypotension
Trauma and hemorrhage are leading causes of death and disability worldwide in both civilian and military contexts. The delivery of life-saving goal-directed fluid resuscitation can be difficult to provide in resource-constrained settings, such as in forward military positions or mass-casualty scenarios. Automated solutions for fluid resuscitation could bridge resource gaps in these austere settings. While multiple physiological closed-loop controllers for the management of hypotension have been proposed, to date there is no consensus on controller design. Here, we compare the performance of four controller types—decision table, single-input fuzzy logic, dual-input fuzzy logic, and proportional–integral–derivative using a previously developed hardware-in-loop test platform where a range of hemorrhage scenarios can be programmed. Controllers were compared using traditional controller performance metrics, but conclusions were difficult to draw due to inconsistencies across the metrics. Instead, we propose three aggregate metrics that reflect the target intensity, stability, and resource efficiency of a controller, with the goal of selecting controllers for further development. These aggregate metrics identify a dual-input, fuzzy-logic-based controller as the preferred combination of intensity, stability, and resource efficiency within this use case. Based on these results, the aggressively tuned dual-input fuzzy logic controller should be considered a priority for further development.
- 27 August 2022
- Published by MDPI AG in Bioengineering
- Vol. 9  (9) , 420
Open AccessHardware-in-Loop Comparison of Physiological Closed-Loop Controllers for the Autonomous Management of Hypotension
Trauma and hemorrhage are leading causes of death and disability worldwide in both civilian and military contexts. The delivery of life-saving goal-directed fluid resuscitation can be difficult to provide in resource-constrained settings, such as in forward military positions or mass-casualty scenarios. Automated solutions for fluid resuscitation could bridge resource gaps in these austere settings. While multiple physiological closed-loop controllers for the management of hypotension have been proposed, to date there is no consensus on controller design. Here, we compare the performance of four controller types—decision table, single-input fuzzy logic, dual-input fuzzy logic, and proportional–integral–derivative using a previously developed hardware-in-loop test platform where a range of hemorrhage scenarios can be programmed. Controllers were compared using traditional controller performance metrics, but conclusions were difficult to draw due to inconsistencies across the metrics. Instead, we propose three aggregate metrics that reflect the target intensity, stability, and resource efficiency of a controller, with the goal of selecting controllers for further development. These aggregate metrics identify a dual-input, fuzzy-logic-based controller as the preferred combination of intensity, stability, and resource efficiency within this use case. Based on these results, the aggressively tuned dual-input fuzzy logic controller should be considered a priority for further development.
- Open Access
- 7 August 2022
- Published by MDPI AG in Bioengineering
- Vol. 9  (8) , 373
An Automated Hardware-in-Loop Testbed for Evaluating Hemorrhagic Shock Resuscitation Controllers
Hemorrhage remains a leading cause of death, with early goal-directed fluid resuscitation being a pillar of mortality prevention. While closed-loop resuscitation can potentially benefit this effort, development of these systems is resource-intensive, making it a challenge to compare infusion controllers and respective hardware within a range of physiologically relevant hemorrhage scenarios. Here, we present a hardware-in-loop automated testbed for resuscitation controllers (HATRC) that provides a simple yet robust methodology to evaluate controllers. HATRC is a flow-loop benchtop system comprised of multiple PhysioVessels which mimic pressure-volume responsiveness for different resuscitation infusates. Subject variability and infusate switching were integrated for more complex testing. Further, HATRC can modulate fluidic resistance to mimic arterial resistance changes after vasopressor administration. Finally, all outflow rates are computer-controlled, with rules to dictate hemorrhage, clotting, and urine rates. Using HATRC, we evaluated a decision-table controller at two sampling rates with different hemorrhage scenarios. HATRC allows quantification of twelve performance metrics for each controller configuration and scenario, producing heterogeneous results and highlighting the need for controller evaluation with multiple hemorrhage scenarios. In conclusion, HATRC can be used to evaluate closed-loop controllers through user-defined hemorrhage scenarios while rating their performance. Extensive controller troubleshooting using HATRC can accelerate product development and subsequent translation.
- 7 August 2022
- Published by MDPI AG in Bioengineering
- Vol. 9  (8) , 373
Open AccessAn Automated Hardware-in-Loop Testbed for Evaluating Hemorrhagic Shock Resuscitation Controllers
Hemorrhage remains a leading cause of death, with early goal-directed fluid resuscitation being a pillar of mortality prevention. While closed-loop resuscitation can potentially benefit this effort, development of these systems is resource-intensive, making it a challenge to compare infusion controllers and respective hardware within a range of physiologically relevant hemorrhage scenarios. Here, we present a hardware-in-loop automated testbed for resuscitation controllers (HATRC) that provides a simple yet robust methodology to evaluate controllers. HATRC is a flow-loop benchtop system comprised of multiple PhysioVessels which mimic pressure-volume responsiveness for different resuscitation infusates. Subject variability and infusate switching were integrated for more complex testing. Further, HATRC can modulate fluidic resistance to mimic arterial resistance changes after vasopressor administration. Finally, all outflow rates are computer-controlled, with rules to dictate hemorrhage, clotting, and urine rates. Using HATRC, we evaluated a decision-table controller at two sampling rates with different hemorrhage scenarios. HATRC allows quantification of twelve performance metrics for each controller configuration and scenario, producing heterogeneous results and highlighting the need for controller evaluation with multiple hemorrhage scenarios. In conclusion, HATRC can be used to evaluate closed-loop controllers through user-defined hemorrhage scenarios while rating their performance. Extensive controller troubleshooting using HATRC can accelerate product development and subsequent translation.
- Open Access
- 5 August 2022
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 12  (8) , 1287
Development and Characterization of an Ex Vivo Testing Platform for Evaluating Automated Central Vascular Access Device Performance
Access to the central vasculature is critical for hemodynamic monitoring and for delivery of life-saving therapeutics during emergency medicine and battlefield trauma situations but requires skill often unavailable in austere environments. Automated central vascular access devices (ACVADs) using ultrasound and robotics are being developed. Here, we present an ex vivo lower-body porcine model as a testing platform for evaluation of vascular devices and compare its features to commercially available platforms. While the commercially available trainers were simpler to set-up and use, the scope of their utility was limited as they were unable to provide realistic anatomic, physiologic, and sonographic properties that were provided by the ex vivo model. However, the ex vivo model was more cumbersome to set-up and use. Overall, both have a place in the development and evaluation pipeline for ACVADs before testing on live animals, thus accelerating product development and translation.
- 5 August 2022
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 12  (8) , 1287
Open AccessDevelopment and Characterization of an Ex Vivo Testing Platform for Evaluating Automated Central Vascular Access Device Performance
Access to the central vasculature is critical for hemodynamic monitoring and for delivery of life-saving therapeutics during emergency medicine and battlefield trauma situations but requires skill often unavailable in austere environments. Automated central vascular access devices (ACVADs) using ultrasound and robotics are being developed. Here, we present an ex vivo lower-body porcine model as a testing platform for evaluation of vascular devices and compare its features to commercially available platforms. While the commercially available trainers were simpler to set-up and use, the scope of their utility was limited as they were unable to provide realistic anatomic, physiologic, and sonographic properties that were provided by the ex vivo model. However, the ex vivo model was more cumbersome to set-up and use. Overall, both have a place in the development and evaluation pipeline for ACVADs before testing on live animals, thus accelerating product development and translation.
- Open Access
- 18 July 2022
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 12  (7) , 1168
Closed-Loop Controlled Fluid Administration Systems: A Comprehensive Scoping Review
Physiological Closed-Loop Controlled systems continue to take a growing part in clinical practice, offering possibilities of providing more accurate, goal-directed care while reducing clinicians’ cognitive and task load. These systems also provide a standardized approach for the clinical management of the patient, leading to a reduction in care variability across multiple dimensions. For fluid management and administration, the advantages of closed-loop technology are clear, especially in conditions that require precise care to improve outcomes, such as peri-operative care, trauma, and acute burn care. Controller design varies from simplistic to complex designs, based on detailed physiological models and adaptive properties that account for inter-patient and intra-patient variability; their maturity level ranges from theoretical models tested in silico to commercially available, FDA-approved products. This comprehensive scoping review was conducted in order to assess the current technological landscape of this field, describe the systems currently available or under development, and suggest further advancements that may unfold in the coming years. Ten distinct systems were identified and discussed.
- 18 July 2022
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 12  (7) , 1168
Open AccessClosed-Loop Controlled Fluid Administration Systems: A Comprehensive Scoping Review
Physiological Closed-Loop Controlled systems continue to take a growing part in clinical practice, offering possibilities of providing more accurate, goal-directed care while reducing clinicians’ cognitive and task load. These systems also provide a standardized approach for the clinical management of the patient, leading to a reduction in care variability across multiple dimensions. For fluid management and administration, the advantages of closed-loop technology are clear, especially in conditions that require precise care to improve outcomes, such as peri-operative care, trauma, and acute burn care. Controller design varies from simplistic to complex designs, based on detailed physiological models and adaptive properties that account for inter-patient and intra-patient variability; their maturity level ranges from theoretical models tested in silico to commercially available, FDA-approved products. This comprehensive scoping review was conducted in order to assess the current technological landscape of this field, describe the systems currently available or under development, and suggest further advancements that may unfold in the coming years. Ten distinct systems were identified and discussed.
- Open Access
- 15 July 2022
- Published by MDPI AG in Bioengineering
- Vol. 9  (7) , 319
Development of a Modular Tissue Phantom for Evaluating Vascular Access Devices
Central vascular access (CVA) may be critical for trauma care and stabilizing the casualty. However, it requires skilled personnel, often unavailable during remote medical situations and combat casualty care scenarios. Automated CVA medical devices have the potential to make life-saving therapeutics available in these resource-limited scenarios, but they must be properly designed. Unfortunately, currently available tissue phantoms are inadequate for this use, resulting in delayed product development. Here, we present a tissue phantom that is modular in design, allowing for adjustable flow rate, circulating fluid pressure, vessel diameter, and vessel positions. The phantom consists of a gelatin cast using a 3D-printed mold with inserts representing vessels and bone locations. These removable inserts allow for tubing insertion which can mimic normal and hypovolemic flow, as well as pressure and vessel diameters. Trauma to the vessel wall is assessed using quantification of leak rates from the tubing after removal from the model. Lastly, the phantom can be adjusted to swine or human anatomy, including modeling the entire neurovascular bundle. Overall, this model can better recreate severe hypovolemic trauma cases and subject variability than commercial CVA trainers and may potentially accelerate automated CVA device development.
- 15 July 2022
- Published by MDPI AG in Bioengineering
- Vol. 9  (7) , 319
Open AccessDevelopment of a Modular Tissue Phantom for Evaluating Vascular Access Devices
Central vascular access (CVA) may be critical for trauma care and stabilizing the casualty. However, it requires skilled personnel, often unavailable during remote medical situations and combat casualty care scenarios. Automated CVA medical devices have the potential to make life-saving therapeutics available in these resource-limited scenarios, but they must be properly designed. Unfortunately, currently available tissue phantoms are inadequate for this use, resulting in delayed product development. Here, we present a tissue phantom that is modular in design, allowing for adjustable flow rate, circulating fluid pressure, vessel diameter, and vessel positions. The phantom consists of a gelatin cast using a 3D-printed mold with inserts representing vessels and bone locations. These removable inserts allow for tubing insertion which can mimic normal and hypovolemic flow, as well as pressure and vessel diameters. Trauma to the vessel wall is assessed using quantification of leak rates from the tubing after removal from the model. Lastly, the phantom can be adjusted to swine or human anatomy, including modeling the entire neurovascular bundle. Overall, this model can better recreate severe hypovolemic trauma cases and subject variability than commercial CVA trainers and may potentially accelerate automated CVA device development.