Amro Obeid
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Amro Obeid has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Ramadan Awad
Department of Physics, Faculty of Science, Beirut Arab University, Beirut, Lebanon
5 shared publicationsMohamed S. Badawi
Physics Department, Faculty of Science, Alexandria University, Alexandria, Egypt; Department of Physics, Faculty of Science, Beirut Arab University, Beirut, Lebanon
4 shared publicationsMohamad Roumie
Lebanese Atomic Energy Commission, National Council for Scientific Research, Beirut, Lebanon
2 shared publicationsBalaa Hanna El
Lebanese Atomic Energy Commission, National Council for Scientific Research, Beirut, Lebanon
1 shared publicationHanna EL Balaa
Lebanese Atomic Energy Commission, National Council for Scientific Research, Beirut, Lebanon
1 shared publication- Khulud Habanjar
Department of Physics, Beirut Arab University, Beirut, Lebanon
1 shared publication
Latest Publications
- Open Access
- 1 January 2024
- Published by National Library of Serbia in Nuclear Technology and Radiation Protection
- Vol. 39 (3) , 199-211
Gamma-ray attenuation characteristics of polypropylene filled with nano-sized and bulk Bi2O3 and CuO
Polypropylene was produced using compression molding and combined with bulk Bi2O3/CuO, and Bi2O3/CuO nanocomposites at various filler weight fractions (0%, 5%, 10%, 15%, and 20%). Gamma-ray energies from four radioactive sources (241Am, 133Ba, 137Cs, and 60Co), ranging from 59.53 keV to 1332.5 keV, were used to evaluate the radiation attenuation capabilities of the new PP/Bi2O3/CuO polymer composite. Parameters such as the mass attenuation coefficients, total molecular cross-section, effective atomic cross-section, total electronic cross-section, electron density, effective atomic number, half-value layer, tenth value layer, and relaxation length were examined. The results underscored the significant influence of both the size and weight fraction of Bi2O3/CuO fillers on the gamma-ray shielding ability of the polypropylene composite, particularly at lower gamma-ray energy levels. Pure lead, a traditional and widely used shielding material, was used as a reference to assess the effectiveness of the polypropylene composite's half-value layer. Polypropylene composites incorporating nano-sized Bi2O3/CuO exhibited notable improvements in attenuation parameters, highlighting their potential for radiation protection and gamma-ray shielding applications.
- 1 January 2024
- Published by National Library of Serbia in Nuclear Technology and Radiation Protection
- Vol. 39 (3) , 199-211
Open AccessGamma-ray attenuation characteristics of polypropylene filled with nano-sized and bulk Bi2O3 and CuO
Polypropylene was produced using compression molding and combined with bulk Bi2O3/CuO, and Bi2O3/CuO nanocomposites at various filler weight fractions (0%, 5%, 10%, 15%, and 20%). Gamma-ray energies from four radioactive sources (241Am, 133Ba, 137Cs, and 60Co), ranging from 59.53 keV to 1332.5 keV, were used to evaluate the radiation attenuation capabilities of the new PP/Bi2O3/CuO polymer composite. Parameters such as the mass attenuation coefficients, total molecular cross-section, effective atomic cross-section, total electronic cross-section, electron density, effective atomic number, half-value layer, tenth value layer, and relaxation length were examined. The results underscored the significant influence of both the size and weight fraction of Bi2O3/CuO fillers on the gamma-ray shielding ability of the polypropylene composite, particularly at lower gamma-ray energy levels. Pure lead, a traditional and widely used shielding material, was used as a reference to assess the effectiveness of the polypropylene composite's half-value layer. Polypropylene composites incorporating nano-sized Bi2O3/CuO exhibited notable improvements in attenuation parameters, highlighting their potential for radiation protection and gamma-ray shielding applications.
- 5 April 2023
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 197, 110790
Gamma-ray attenuation parameters of HDPE filled with different nano-size and Bulk WO3
- 5 April 2023
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 197, 110790
Gamma-ray attenuation parameters of HDPE filled with different nano-size and Bulk WO3
- 9 November 2022
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 137 (11) , 1-15
Attenuation parameters of HDPE filled with different nano-size and bulk WO3 for X-ray shielding applications
- 9 November 2022
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 137 (11) , 1-15
Attenuation parameters of HDPE filled with different nano-size and bulk WO3 for X-ray shielding applications
- 31 January 2022
- Published by Springer Nature in Journal of Inorganic and Organometallic Polymers and Materials
- Vol. 32 (4) , 1506-1519
Evaluation of the Effect of Different Nano-Size of WO3 on the Structural and Mechanical Properties of HDPE
- 31 January 2022
- Published by Springer Nature in Journal of Inorganic and Organometallic Polymers and Materials
- Vol. 32 (4) , 1506-1519
Evaluation of the Effect of Different Nano-Size of WO3 on the Structural and Mechanical Properties of HDPE
- 10 January 2022
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 43 (3) , 1-17
Evaluation of the Effect of Different Nano-Size of WO3 Addition on the Thermal Properties of HDPE Composite
- 10 January 2022
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 43 (3) , 1-17
Evaluation of the Effect of Different Nano-Size of WO3 Addition on the Thermal Properties of HDPE Composite
- Open Access
- 1 January 2021
- Published by National Library of Serbia in Nuclear Technology and Radiation Protection
- Vol. 36 (4) , 315-328
Effects of different nano size and bulk WO3 enriched by HDPE composites on attenuation of the X-ray narrow spectrum
The X-rays of the narrow-spectrum N-series ranging from 40 kV to 150 kV were used to determine the radiation attenuation ability of a new category of a polymer composite fabricated for shielding purposes. High density polyethylene was synthesized through a compression molding technique, and incorporated with various filler amounts (10, 15, 25, and 35 wt.%) of bulk micro-sized WO 3 (Sample A), two WO 3 nanoparticles 45 nm (Sample B), and 24 nm (Sample C). The WO 3 filler was identified and characterized using X-ray diffraction and a transmission electron microscope. The mass distribution of the chemical elements of the synthesized composites was determined by energy dispersive X-ray analysis. The obtained results of the different attenuation parameters revealed that the particle size and weight fraction of WO particles have an outstanding effect on the X-ray shielding ability of this composite. The 3 experimental measurements of the mass attenuation coefficients were compared to the theoretical values tabulated in the NIST databases XCOM and FFAST. The mass attenuation coefficient was increased with the increment of WO 3 wt.% as well as with the decrease of the WO 3 particle size. This improvement in the attenuation parameters of the NP(C) composite suggests their promising applications in radiation protection at the diagnostic level.
- 1 January 2021
- Published by National Library of Serbia in Nuclear Technology and Radiation Protection
- Vol. 36 (4) , 315-328
Open AccessEffects of different nano size and bulk WO3 enriched by HDPE composites on attenuation of the X-ray narrow spectrum
The X-rays of the narrow-spectrum N-series ranging from 40 kV to 150 kV were used to determine the radiation attenuation ability of a new category of a polymer composite fabricated for shielding purposes. High density polyethylene was synthesized through a compression molding technique, and incorporated with various filler amounts (10, 15, 25, and 35 wt.%) of bulk micro-sized WO 3 (Sample A), two WO 3 nanoparticles 45 nm (Sample B), and 24 nm (Sample C). The WO 3 filler was identified and characterized using X-ray diffraction and a transmission electron microscope. The mass distribution of the chemical elements of the synthesized composites was determined by energy dispersive X-ray analysis. The obtained results of the different attenuation parameters revealed that the particle size and weight fraction of WO particles have an outstanding effect on the X-ray shielding ability of this composite. The 3 experimental measurements of the mass attenuation coefficients were compared to the theoretical values tabulated in the NIST databases XCOM and FFAST. The mass attenuation coefficient was increased with the increment of WO 3 wt.% as well as with the decrease of the WO 3 particle size. This improvement in the attenuation parameters of the NP(C) composite suggests their promising applications in radiation protection at the diagnostic level.