Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tiago Coelho-Magalhães has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Numerical-Optimal-Control-Compliant Muscle Model for Electrically Evoked Contractions

    by Tiago Coelho-Magalhães, Christine Azevedo-Coste, François Bailly

    In this paper, an existing physiological muscle model that predicts muscular force in response to electrical stimulation is adapted to be compatible with gradient-based optimization, in particular with numerical optimal control/estimation problems. The objective is to integrate biomechanical models with those that correlate muscle force generation with electrical pulses from a physiological perspective, with the aim of achieving optimal stimulation patterns in activities assisted by functional electrical stimulation. To this end, the activation dynamics of the original model, initially constrained to a stimulation train of predefined and constant length, is reformulated to account for stimulation sequences that dynamically change over time. This is typically necessary to simulate complex motions, which would otherwise be impossible to achieve with the earliest formulation. To identify the model parameters, experimental torque data of 3 participants with spinal cord injury performing electrically evoked isometric quadriceps contractions at different knee angles are used. We then employ an optimal control framework to demonstrate the model’s ability to predict knee torques and the possibility of achieving optimized stimulation patterns in simulation for controlling muscle force and knee extension. Our results reveal that the identified model allows accurate prediction of knee torque and optimization of stimulation patterns while satisfying the system’s dynamics at the skeletal and physiological muscle levels. This proof of concept is a first step towards physiological muscle model-based control of functional electrical stimulation to achieve movements that best exploit an individual’s physiological and biomechanical characteristics.


  • Open Access

    Development of a High-Power Capacity Open Source Electrical Stimulation System to Enhance Research into FES-Assisted Devices: Validation of FES Cycling

    by Tiago Coelho-Magalhães, Emerson Fachin-Martins, Andressa Silva, Christine Azevedo Coste, Henrique Resende-Martins

    Since the first Cybathlon 2016, when twelve teams competed in the FES bike race, we have witnessed a global effort towards the development of stimulation and control strategies to improve FES-assisted devices, particularly for cycling, as a means to practice a recreational physical activity. As a result, a set of technical notes and research paved the way for many other studies and the potential behind FES-assisted cycling has been consolidated. However, engineering research needs instrumented devices to support novel developments and enable precise assessment. Therefore, some researchers struggle to develop their own FES-assisted devices or find it challenging to implement their instrumentation using commercial devices, which often limits the implementation of advanced control strategies and the possibility to connect different types of sensor. In this regard, we hypothesize that it would be advantageous for some researchers in our community to enjoy access to an entire open-source FES platform that allows different control strategies to be implemented, offers greater adaptability and power capacity than commercial devices, and can be used to assist different functional activities in addition to cycling. Hence, it appears to be of interest to make our proprietary electrical stimulation system an open-source device and to prove its capabilities by addressing all the aspects necessary to implement a FES cycling system. The high-power capacity stimulation device is based on a constant current topology that allows the creation of biphasic electrical pulses with amplitude, width, and frequency up to 150 mA, 1000 µs, and 100 Hz, respectively. A mobile application (Android) was developed to set and modify the stimulation parameters of up to eight stimulation channels. A proportional-integral controller was implemented for cadence tracking with the aim to improve the overall cycling performance. A volunteer with complete paraplegia participated in the functional testing of the system. He was able to cycle indoors for 45 min, accomplish distances of more than 5 km using a passive cycling trainer, and pedal 2400 m overground in 32 min. The results evidenced the capacity of our FES cycling system to be employed as a cycling tool for individuals with spinal cord injury. The methodological strategies used to improve FES efficiency suggest the possibility of maximizing pedaling duration through more advanced control techniques.