Michele Girardi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Michele Girardi has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Nicolò
Department of Movement, Human and Health Sciences, University of Rome “Foro Italico”, Rome, Italy
8 shared publications - Chiara Gattoni
The Lundquist Institute for Biomedical Innovation at Harbor-UCLA Medical Center, Torrance, USA
7 shared publications - Massimo Sacchetti
Department of Movement, Human and Health Sciences, University of Rome “Foro Italico”, Rome, Italy
7 shared publications - Carlo Capelli
Department of Pathophysiology and Transplantation, Section of Physiology, University of Milano, Milano, Italy
6 shared publications - Carrie Ferguson
The Lundquist Institute for Biomedical Innovation at Harbor-UCLA Medical Center , Torrance, CA
6 shared publications - Samuele Maria Marcora
Department of Quality of Life Studies, University of Bologna, Rimini, Italy
5 shared publications
Latest Publications
- 14 September 2026
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 58 (10S)
Changes In Lung Mechanics, Ventilatory Demand And Expiratory Flow Limitation With Healthy Aging
Was not provided for this article.
- 14 September 2026
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 58 (10S)
Changes In Lung Mechanics, Ventilatory Demand And Expiratory Flow Limitation With Healthy Aging
Was not provided for this article.
- 2 July 2026
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 126 (10) , 5379-5396
Effects of normobaric hypoxia and hyperthermia on ventilatory responses to high-intensity interval training bouts
Respiratory frequency (fR) and tidal volume (VT) show distinct responses during high-intensity interval training (HIIT) bouts, yet the underlying mechanisms remain unclear. We investigated the effects of hypoxia and hyperthermia on ventilatory responses to HIIT bouts. Ten recreationally trained males (mean ± SD: peak oxygen uptake: 3.98 ± 0.62 L/min, age: 28 ± 6 years) performed the same HIIT protocol to exhaustion in three randomized conditions: normobaric hypoxia (HYP, 15% O2), hyperthermia (HOT, 35 °C, 40% humidity), and control (CON, 18 °C and 40% humidity). Work-recovery phases (30-30 s) were performed at 109% of peak power output from a prior incremental test and 50 W, respectively. Time-to-exhaustion (TTE) differed (P < 0.05) across CON (18.0 ± 4.4 min), HYP (9.4 ± 2.8 min), and HOT (12.6 ± 3.1 min) conditions. Iso-time fR was associated with changes in TTE and positively correlated with perceived exertion (P < 0.001; r = 0.85) and aural temperature (P < 0.001; r = 0.58). On average, fR increased during the work phase and decreased during recovery, primarily driving pulmonary ventilation ([Formula: see text]) during work-recovery alternations. Conversely, VT showed a smaller and opposite response, with higher values during recovery. VT plateaued in all conditions, but higher values were observed in HYP versus CON and HOT, accompanied by higher capillary blood lactate levels and lower blood oxygen saturation. fR is associated with changes in exercise tolerance irrespective of the environmental conditions tested and is more closely related to perceived exertion than to aural temperature. fR primarily drives the [Formula: see text] response to high-intensity work-recovery alternations, while VT appears fine-tuned on fR levels and the magnitude of metabolic inputs.
- 2 July 2026
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 126 (10) , 5379-5396
Effects of normobaric hypoxia and hyperthermia on ventilatory responses to high-intensity interval training bouts
Respiratory frequency (fR) and tidal volume (VT) show distinct responses during high-intensity interval training (HIIT) bouts, yet the underlying mechanisms remain unclear. We investigated the effects of hypoxia and hyperthermia on ventilatory responses to HIIT bouts. Ten recreationally trained males (mean ± SD: peak oxygen uptake: 3.98 ± 0.62 L/min, age: 28 ± 6 years) performed the same HIIT protocol to exhaustion in three randomized conditions: normobaric hypoxia (HYP, 15% O2), hyperthermia (HOT, 35 °C, 40% humidity), and control (CON, 18 °C and 40% humidity). Work-recovery phases (30-30 s) were performed at 109% of peak power output from a prior incremental test and 50 W, respectively. Time-to-exhaustion (TTE) differed (P < 0.05) across CON (18.0 ± 4.4 min), HYP (9.4 ± 2.8 min), and HOT (12.6 ± 3.1 min) conditions. Iso-time fR was associated with changes in TTE and positively correlated with perceived exertion (P < 0.001; r = 0.85) and aural temperature (P < 0.001; r = 0.58). On average, fR increased during the work phase and decreased during recovery, primarily driving pulmonary ventilation ([Formula: see text]) during work-recovery alternations. Conversely, VT showed a smaller and opposite response, with higher values during recovery. VT plateaued in all conditions, but higher values were observed in HYP versus CON and HOT, accompanied by higher capillary blood lactate levels and lower blood oxygen saturation. fR is associated with changes in exercise tolerance irrespective of the environmental conditions tested and is more closely related to perceived exertion than to aural temperature. fR primarily drives the [Formula: see text] response to high-intensity work-recovery alternations, while VT appears fine-tuned on fR levels and the magnitude of metabolic inputs.
- Open Access
- 17 February 2026
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 126 (3) , 1303
Correction: The effects of one-night sleep deprivation and one-night recovery sleep on endurance cycling performance
- 17 February 2026
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 126 (3) , 1303
Open AccessCorrection: The effects of one-night sleep deprivation and one-night recovery sleep on endurance cycling performance
- Open Access
- 25 July 2025
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 126 (3) , 1287-1302
The effects of one-night sleep deprivation and one-night recovery sleep on endurance cycling performance
Purpose: Sleep deprivation (SD) seems to impair endurance performance. However, little research is available on the effects of SD in the context of repeated bouts of endurance exercise. The effect of recovery sleep on endurance performance is also poorly understood. Methods: Twenty-six male amateur cyclists/triathletes (mean ± SD: age 30.5 ± 8.8 yr, $$\dot{\text{V}}{\mathrm{O}}$$ 2peak 55.3 ± 4.9 mL/kg/min) were randomly allocated to SD and CONTROL groups and tested over 3 consecutive days. After baseline testing (day 1), the SD group did not sleep for 25 h (day 2) and slept normally the following night (day 3). The CONTROL group slept normally throughout the experiment. Endurance performance was assessed during 40-min moderate-intensity constant-workload cycling and 20-min time trial. Electroencephalography, questionnaires, and psychomotor vigilance task were used to assess sleepiness and vigilance before cycling. Ratings of perceived exertion (RPE), Feeling scale (FS), heart rate (HR), and blood lactate were assessed during cycling. Results: Sleepiness and vigilance were impaired after SD ( p < 0.05), but returned to baseline after recovery sleep. RPE ( p = 0.023) and FS ( p = 0.013) assessed during the 40-min cycling were negatively affected by SD, but returned to baseline after recovery sleep. HR and blood lactate were not affected by SD. No significant interaction effect was observed on time-trial work. Conclusion: In the context of 3 consecutive days of endurance cycling, 25-h SD negatively affected moderate-intensity performance through higher RPE, but did not affect the 20-min time trial. One-night recovery sleep was sufficient to restore moderate-intensity endurance cycling performance.- 25 July 2025
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 126 (3) , 1287-1302
Open AccessThe effects of one-night sleep deprivation and one-night recovery sleep on endurance cycling performance
Purpose: Sleep deprivation (SD) seems to impair endurance performance. However, little research is available on the effects of SD in the context of repeated bouts of endurance exercise. The effect of recovery sleep on endurance performance is also poorly understood. Methods: Twenty-six male amateur cyclists/triathletes (mean ± SD: age 30.5 ± 8.8 yr, $$\dot{\text{V}}{\mathrm{O}}$$ 2peak 55.3 ± 4.9 mL/kg/min) were randomly allocated to SD and CONTROL groups and tested over 3 consecutive days. After baseline testing (day 1), the SD group did not sleep for 25 h (day 2) and slept normally the following night (day 3). The CONTROL group slept normally throughout the experiment. Endurance performance was assessed during 40-min moderate-intensity constant-workload cycling and 20-min time trial. Electroencephalography, questionnaires, and psychomotor vigilance task were used to assess sleepiness and vigilance before cycling. Ratings of perceived exertion (RPE), Feeling scale (FS), heart rate (HR), and blood lactate were assessed during cycling. Results: Sleepiness and vigilance were impaired after SD ( p < 0.05), but returned to baseline after recovery sleep. RPE ( p = 0.023) and FS ( p = 0.013) assessed during the 40-min cycling were negatively affected by SD, but returned to baseline after recovery sleep. HR and blood lactate were not affected by SD. No significant interaction effect was observed on time-trial work. Conclusion: In the context of 3 consecutive days of endurance cycling, 25-h SD negatively affected moderate-intensity performance through higher RPE, but did not affect the 20-min time trial. One-night recovery sleep was sufficient to restore moderate-intensity endurance cycling performance. - Open Access
- 21 February 2025
- Published by Wiley in Experimental Physiology
- Vol. 110 (6) , 790-797
Breath‐by‐breath measurement of alveolar gas exchange must preserve mass balance and conform to a physiological definition of a breath
Tidal breathing in awake humans is variable. This variability causes changes in lung gas stores that affect gas exchange measurements. To overcome this, several algorithms provide solutions for breath‐by‐breath alveolar gas exchange measurement; however, there is no consensus on a physiologically robust method suitable for widespread application. A recent approach, the ‘independent‐breath’ (IND) algorithm, avoids the complexity of measuring breath‐by‐breath changes in lung volume by redefining what is meant by a ‘breath’. Specifically, it defines a single breathing cycle as the time between equal values of the / (or /) ratio, that is, the ratio of fractional concentrations of lung‐expired O2 (or CO2) and nitrogen (N2). These developments imply that the end of one breath is not, by necessity, aligned with the start of the next. Here we demonstrate how the use of the IND algorithm fails to conserve breath‐by‐breath mass balance of O2 and CO2 exchanged between the atmosphere and tissues (and vice versa). We propose a new term, within the IND algorithm, designed to overcome this limitation. We also present the far‐reaching implications of using algorithms based on alternative definitions of the breathing cycle, including challenges in measuring and interpreting the respiratory exchange ratio, pulmonary gas exchange efficiency, dead space fraction of the breath, control of breathing, and a broad spectrum of clinically relevant cardiopulmonary exercise testing variables. Therefore, we do not support the widespread adoption of currently available alternative definitions of the breathing cycle as a legitimate solution for breath‐by‐breath alveolar gas exchange measurement in research or clinical settings.
- 21 February 2025
- Published by Wiley in Experimental Physiology
- Vol. 110 (6) , 790-797
Open AccessBreath‐by‐breath measurement of alveolar gas exchange must preserve mass balance and conform to a physiological definition of a breath
Tidal breathing in awake humans is variable. This variability causes changes in lung gas stores that affect gas exchange measurements. To overcome this, several algorithms provide solutions for breath‐by‐breath alveolar gas exchange measurement; however, there is no consensus on a physiologically robust method suitable for widespread application. A recent approach, the ‘independent‐breath’ (IND) algorithm, avoids the complexity of measuring breath‐by‐breath changes in lung volume by redefining what is meant by a ‘breath’. Specifically, it defines a single breathing cycle as the time between equal values of the / (or /) ratio, that is, the ratio of fractional concentrations of lung‐expired O2 (or CO2) and nitrogen (N2). These developments imply that the end of one breath is not, by necessity, aligned with the start of the next. Here we demonstrate how the use of the IND algorithm fails to conserve breath‐by‐breath mass balance of O2 and CO2 exchanged between the atmosphere and tissues (and vice versa). We propose a new term, within the IND algorithm, designed to overcome this limitation. We also present the far‐reaching implications of using algorithms based on alternative definitions of the breathing cycle, including challenges in measuring and interpreting the respiratory exchange ratio, pulmonary gas exchange efficiency, dead space fraction of the breath, control of breathing, and a broad spectrum of clinically relevant cardiopulmonary exercise testing variables. Therefore, we do not support the widespread adoption of currently available alternative definitions of the breathing cycle as a legitimate solution for breath‐by‐breath alveolar gas exchange measurement in research or clinical settings.
- Open Access
- 31 January 2025
- Published by European Respiratory Society (ERS) in ERJ Open Research
- Vol. 11 (3)
Wasted ventilation in mild COPD: protocol for a clinical physiology and functional imaging study
Background: High ventilation–CO2output, signaling increased wasted ventilation in the physiological dead space (VDphys), has a dominant role in eliciting activity-related dyspnoea in subjects with COPD showing only mild airflow obstruction. Exposing the mechanisms driving wasted ventilation is key to advancing the field towards new therapeutic approaches to improve dyspnoea and exercise tolerance in this growing patient sub-population.Central hypothesis: Increased areas of high alveolar ventilation (V̇A)/capillary perfusion (Q̇c) due to impairedQ̇cin nonemphysematous, non-air trapping areas of the lungs add to any underlying emphysema to increase wasted ventilation and exertional dyspnoea in mild COPD.Methods: 40 patients (20 women) showing post-bronchodilator forced expiratory volume in 1 s ≥70% predicted and 20 sex- and age-matched controls will perform constant load exercise tests in a flutter-kicking device in the physiology laboratory and, in another visit, a magnetic resonance imaging (MRI) facility. Volumetric capnography will be used to breath-by-breath quantify rest and exerciseVDphys. Free-breathing, noncontrast proton MRI (phase-resolved functional lung (PREFUL))V̇A,Q̇candV̇A/Q̇c,maps will be co-registered to emphysema and air trapping severity and distribution as established by computed tomography (parametric response mapping).Study implications: Confirmation of the study's main hypothesis will provide the first evidence that increased wasted ventilation in dyspnoeic patients with mild COPD is not a mere consequence of emphysematous destruction being also reflective of impaired perfusion across apparently preserved lung tissue. This will set the stage for subsequent interventional studies geared to address this potentially treatable disease trait.
- 31 January 2025
- Published by European Respiratory Society (ERS) in ERJ Open Research
- Vol. 11 (3)
Open AccessWasted ventilation in mild COPD: protocol for a clinical physiology and functional imaging study
Background: High ventilation–CO2output, signaling increased wasted ventilation in the physiological dead space (VDphys), has a dominant role in eliciting activity-related dyspnoea in subjects with COPD showing only mild airflow obstruction. Exposing the mechanisms driving wasted ventilation is key to advancing the field towards new therapeutic approaches to improve dyspnoea and exercise tolerance in this growing patient sub-population.Central hypothesis: Increased areas of high alveolar ventilation (V̇A)/capillary perfusion (Q̇c) due to impairedQ̇cin nonemphysematous, non-air trapping areas of the lungs add to any underlying emphysema to increase wasted ventilation and exertional dyspnoea in mild COPD.Methods: 40 patients (20 women) showing post-bronchodilator forced expiratory volume in 1 s ≥70% predicted and 20 sex- and age-matched controls will perform constant load exercise tests in a flutter-kicking device in the physiology laboratory and, in another visit, a magnetic resonance imaging (MRI) facility. Volumetric capnography will be used to breath-by-breath quantify rest and exerciseVDphys. Free-breathing, noncontrast proton MRI (phase-resolved functional lung (PREFUL))V̇A,Q̇candV̇A/Q̇c,maps will be co-registered to emphysema and air trapping severity and distribution as established by computed tomography (parametric response mapping).Study implications: Confirmation of the study's main hypothesis will provide the first evidence that increased wasted ventilation in dyspnoeic patients with mild COPD is not a mere consequence of emphysematous destruction being also reflective of impaired perfusion across apparently preserved lung tissue. This will set the stage for subsequent interventional studies geared to address this potentially treatable disease trait.
- 1 November 2024
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 137 (5) , 1130-1144
A novel method for determining ventilatory and gas exchange dynamics during exercise: the “chirp” waveform
We investigated the ability of a novel waveform to extract exercise ventilatory and gas exchange dynamics. In the chirp waveform, work rate fluctuates sinusoidally with constant amplitude as sinusoidal period decreases progressively over 30 min of exercise. In a study of 31 healthy individuals and patients with COPD, comparison of exercise dynamics derived from chirp to those from stepwise waveforms suggests that the chirp waveform is a promising method for derivation of exercise response dynamics.
- 1 November 2024
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 137 (5) , 1130-1144
A novel method for determining ventilatory and gas exchange dynamics during exercise: the “chirp” waveform
We investigated the ability of a novel waveform to extract exercise ventilatory and gas exchange dynamics. In the chirp waveform, work rate fluctuates sinusoidally with constant amplitude as sinusoidal period decreases progressively over 30 min of exercise. In a study of 31 healthy individuals and patients with COPD, comparison of exercise dynamics derived from chirp to those from stepwise waveforms suggests that the chirp waveform is a promising method for derivation of exercise response dynamics.
- 1 October 2024
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 56 (10S) , 1140
Sensitivity And Specificity Of Geometric Techniques To Identify Expiratory Flow Limitation During Exercise
- 1 October 2024
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 56 (10S) , 1140
Sensitivity And Specificity Of Geometric Techniques To Identify Expiratory Flow Limitation During Exercise
- 1 April 2024
- Published by American Physiological Society in American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
- Vol. 326 (4) , R331-R332
Reply to Francescato and Cettolo
- 1 April 2024
- Published by American Physiological Society in American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
- Vol. 326 (4) , R331-R332
Reply to Francescato and Cettolo