Konstantinos Stergiaropoulos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Konstantinos Stergiaropoulos has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Lukas Siebler
Institute for Building Energetics, Thermotechnology and Energy Storage (IGTE), University of Stuttgart
3 shared publications - Maurizio Calandri
Institute for Building Energetics, Thermotechnology and Energy Storage (IGTE), University of Stuttgart, Stuttgart, Baden-Württemberg, Germany
3 shared publications - Torben Rathje
Institute for Building Energetics, Thermotechnology and Energy Storage (IGTE), University of Stuttgart, Stuttgart, Germany
3 shared publications - Bernhard Richter
Freiburger Institut für Musikermedizin (FIM), Hochschule für Musik und Universitätsklinikum Freiburg, Freiburg, Deutschland
2 shared publications - Claudia Spahn
University of Music Freiburg, Medical Faculty University Freiburg, University Clinic Freiburg
2 shared publications - Harald Drück
University of Stuttgart
2 shared publications
Latest Publications
- Open Access
- 5 June 2026
- Published by TIB Open Publishing in International Sustainable Energy Conference - Proceedings
- Vol. 2
An Approach for a Discursive Transformation of Energy Systems Using Aggregated Building Models
Aggregated building models are defined as Urban Building Energy Models (UBEM) in which model complexity is reduced through the use of aggregated buildings characterized by building archetypes. These models are important tools for analyzing heating, cooling, and electricity demand at district- to city-level. An extended aggregated building model that refines national building archetypes on local building archetypes is proposed. Stakeholder surveys, as part of a toolbox, are used to collect input data for the characteristics of buildings and energy supply systems, as well as user behavior. The use of local building archetypes derived from this data increases the validity of the results compared to the use of national building archetypes. The methodology to generate local building archetypes based on data from stakeholder surveys is presented.
- 5 June 2026
- Published by TIB Open Publishing in International Sustainable Energy Conference - Proceedings
- Vol. 2
Open AccessAn Approach for a Discursive Transformation of Energy Systems Using Aggregated Building Models
Aggregated building models are defined as Urban Building Energy Models (UBEM) in which model complexity is reduced through the use of aggregated buildings characterized by building archetypes. These models are important tools for analyzing heating, cooling, and electricity demand at district- to city-level. An extended aggregated building model that refines national building archetypes on local building archetypes is proposed. Stakeholder surveys, as part of a toolbox, are used to collect input data for the characteristics of buildings and energy supply systems, as well as user behavior. The use of local building archetypes derived from this data increases the validity of the results compared to the use of national building archetypes. The methodology to generate local building archetypes based on data from stakeholder surveys is presented.
- Open Access
- 3 June 2026
- Published by TIB Open Publishing in International Sustainable Energy Conference - Proceedings
- Vol. 2
Effects of Heat Saving Measures on Thermal Comfort in an Office Building in Germany
This paper reports findings from a real-world laboratory that examined heat saving potential and room comfort under a range of single room control heating strategies in a fifty person office building with small shared office rooms. Overall room comfort was found to be determined by thermal comfort, by measured indoor air temperatures above 18 ◦C and by users’ perception of the weather. Visual, acoustic and respiratory factors were hardly found to influence overall room comfort. The strategies evaluated comprised no pre-heating to up to 90 minutes of pre-heating before the anticipated arrival of users. None of the strategies produced a marked reduction in reported thermal comfort, whereas heat savings of 9 to 51 % relative to a conventional heating control strategy were achieved.
- 3 June 2026
- Published by TIB Open Publishing in International Sustainable Energy Conference - Proceedings
- Vol. 2
Open AccessEffects of Heat Saving Measures on Thermal Comfort in an Office Building in Germany
This paper reports findings from a real-world laboratory that examined heat saving potential and room comfort under a range of single room control heating strategies in a fifty person office building with small shared office rooms. Overall room comfort was found to be determined by thermal comfort, by measured indoor air temperatures above 18 ◦C and by users’ perception of the weather. Visual, acoustic and respiratory factors were hardly found to influence overall room comfort. The strategies evaluated comprised no pre-heating to up to 90 minutes of pre-heating before the anticipated arrival of users. None of the strategies produced a marked reduction in reported thermal comfort, whereas heat savings of 9 to 51 % relative to a conventional heating control strategy were achieved.
- Open Access
- 17 April 2026
- Published by TIB Open Publishing in International Sustainable Energy Conference - Proceedings
- Vol. 2
Development of Improved Heat Sources for a New Generation of Cold District Heating Systems
Cold district heating systems offer the opportunity to utilize low temperature heat sources for the heat supply of buildings. They are often operated in combination with thermal energy stores and heat pumps. In this publication air-brine-collectors and an ice store are investigated experimentally to improve the heat transfer and therefore increase the efficiency of connected heat pumps due to higher source temperatures. Firstly, several investigations with an experimental ice store were performed. On the one hand, the heat transfer capacity of the heat exchanger in the ice store could be increased significantly in regeneration periods. On the other hand, the heat transfer capacity of the heat exchanger could also be increased by 62 % in extraction periods during dynamically alternating extraction and regeneration periods compared to continuous extraction without dynamical alternation. Secondly, the effect of ice formation around the heat exchanger pipes and fins of an air-brine-collector on the heat transfer was investigated. Therefore, a PVT air-brine-collector was installed in a climate chamber and operated under boundary conditions supporting ice formation by a factor of approximately 3 compared to boundary conditions at a real system in southern Germany. During 21 hours of ice formation the heat transfer capacity decreased by 36 % due to increasing thermal resistances caused by various influencing factors like ice formation and a decreasing volume flow rate. Based on analytical calculations of the thermal resistances it is assumed that limited air convection due to increased ice formation between the fins of the heat exchanger has the most significant influence on the heat transfer between heat transfer medium and ambient air.
- 17 April 2026
- Published by TIB Open Publishing in International Sustainable Energy Conference - Proceedings
- Vol. 2
Open AccessDevelopment of Improved Heat Sources for a New Generation of Cold District Heating Systems
Cold district heating systems offer the opportunity to utilize low temperature heat sources for the heat supply of buildings. They are often operated in combination with thermal energy stores and heat pumps. In this publication air-brine-collectors and an ice store are investigated experimentally to improve the heat transfer and therefore increase the efficiency of connected heat pumps due to higher source temperatures. Firstly, several investigations with an experimental ice store were performed. On the one hand, the heat transfer capacity of the heat exchanger in the ice store could be increased significantly in regeneration periods. On the other hand, the heat transfer capacity of the heat exchanger could also be increased by 62 % in extraction periods during dynamically alternating extraction and regeneration periods compared to continuous extraction without dynamical alternation. Secondly, the effect of ice formation around the heat exchanger pipes and fins of an air-brine-collector on the heat transfer was investigated. Therefore, a PVT air-brine-collector was installed in a climate chamber and operated under boundary conditions supporting ice formation by a factor of approximately 3 compared to boundary conditions at a real system in southern Germany. During 21 hours of ice formation the heat transfer capacity decreased by 36 % due to increasing thermal resistances caused by various influencing factors like ice formation and a decreasing volume flow rate. Based on analytical calculations of the thermal resistances it is assumed that limited air convection due to increased ice formation between the fins of the heat exchanger has the most significant influence on the heat transfer between heat transfer medium and ambient air.
- Open Access
- 24 April 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (9) , 4741
Post-Occupancy Evaluation in High-Rise Apartment Buildings in Vietnam
As part of the CAMaRSEC research project, long-term indoor environmental measurements with accompanying occupant surveys were conducted over one year in 49 households in 15 high-rise residential apartment buildings in Hanoi, Vietnam. A comprehensive analysis of the collected data revealed differences in the indoor environment and energy consumption patterns during the operational phase of the buildings, as well as their correlation with diverse occupant behaviors. In addition, by comparing subjective thermal evaluations based on occupant surveys with predictions based on comfort models, the limitations of existing models in predicting the thermal sensations of local people were identified. Furthermore, the findings indicated that the apartment building design standard in Vietnam underestimates the thermal adaptation of occupants, which may lead to significant building performance gaps. Larger scale surveys and measurements are required to provide sufficient databases to refine local building design standards, especially for mixed-mode buildings.
- 24 April 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (9) , 4741
Open AccessPost-Occupancy Evaluation in High-Rise Apartment Buildings in Vietnam
As part of the CAMaRSEC research project, long-term indoor environmental measurements with accompanying occupant surveys were conducted over one year in 49 households in 15 high-rise residential apartment buildings in Hanoi, Vietnam. A comprehensive analysis of the collected data revealed differences in the indoor environment and energy consumption patterns during the operational phase of the buildings, as well as their correlation with diverse occupant behaviors. In addition, by comparing subjective thermal evaluations based on occupant surveys with predictions based on comfort models, the limitations of existing models in predicting the thermal sensations of local people were identified. Furthermore, the findings indicated that the apartment building design standard in Vietnam underestimates the thermal adaptation of occupants, which may lead to significant building performance gaps. Larger scale surveys and measurements are required to provide sufficient databases to refine local building design standards, especially for mixed-mode buildings.
- Open Access
- 1 January 2025
- Published by Wiley in Indoor Air
- Vol. 2025 (1)
Ventilation Effectiveness: Overview of Terminology and Analysis of Influencing Parameters
Ventilation effectiveness evaluates the performance of ventilation systems by assessing air exchange and contaminant removal. Optimising ventilation effectiveness in mechanical ventilation systems reduces the required supply airflow rate while maintaining adequate indoor air quality. This review clarifies inconsistent definitions of ventilation effectiveness in standards and literature and provides a comprehensive overview of terms, definitions, and relevant parameters. The review also analyses the influence of variable and building‐fixed parameters on ventilation effectiveness using data from selected studies. Contaminant position and supply/exhaust position had the greatest impact on ventilation effectiveness, with maximum absolute changes of 2.1 and 0.94, respectively. Variable parameters, such as air change rate and temperature difference, showed moderate mean absolute changes of 0.28 and 0.15 but significant maximum deviations of 0.85 and 0.4. Building‐fixed parameters, including room size and aspect ratio, showed the least influence, with mean absolute changes below 0.1. These results highlight the importance of parameter interactions, such as short‐circuit flows caused by higher air velocities. In EN 16798‐1:2022, design values for required airflow are based on a ventilation effectiveness of 1. However, the analysis shows large variations around this value, indicating potential deficits in air quality and opportunities for energy savings. This review highlights the need for holistic system design and consideration of parameter interactions to optimise energy efficiency and air quality.
- 1 January 2025
- Published by Wiley in Indoor Air
- Vol. 2025 (1)
Open AccessVentilation Effectiveness: Overview of Terminology and Analysis of Influencing Parameters
Ventilation effectiveness evaluates the performance of ventilation systems by assessing air exchange and contaminant removal. Optimising ventilation effectiveness in mechanical ventilation systems reduces the required supply airflow rate while maintaining adequate indoor air quality. This review clarifies inconsistent definitions of ventilation effectiveness in standards and literature and provides a comprehensive overview of terms, definitions, and relevant parameters. The review also analyses the influence of variable and building‐fixed parameters on ventilation effectiveness using data from selected studies. Contaminant position and supply/exhaust position had the greatest impact on ventilation effectiveness, with maximum absolute changes of 2.1 and 0.94, respectively. Variable parameters, such as air change rate and temperature difference, showed moderate mean absolute changes of 0.28 and 0.15 but significant maximum deviations of 0.85 and 0.4. Building‐fixed parameters, including room size and aspect ratio, showed the least influence, with mean absolute changes below 0.1. These results highlight the importance of parameter interactions, such as short‐circuit flows caused by higher air velocities. In EN 16798‐1:2022, design values for required airflow are based on a ventilation effectiveness of 1. However, the analysis shows large variations around this value, indicating potential deficits in air quality and opportunities for energy savings. This review highlights the need for holistic system design and consideration of parameter interactions to optimise energy efficiency and air quality.
- Open Access
- 20 July 2023
- Published by Springer Nature in BMC Public Health
- Vol. 23 (1) , 1-19
A coupled experimental and statistical approach for an assessment of SARS-CoV-2 infection risk at indoor event locations
Indoor event locations are particularly affected by the SARS-CoV-2 pandemic. At large venues, only incomplete risk assessments exist, whereby no suitable measures can be derived. In this study, a physical and data-driven statistical model for a comprehensive infection risk assessment has been developed. At venues displacement ventilation concepts are often implemented. Here simplified theoretical assumptions fail for the prediction of relevant airflows for airborne transmission processes. Thus, with locally resolving trace gas measurements infection risks are computed more detailed. Coupled with epidemiological data such as incidences, vaccination rates, test sensitivities, and audience characteristics such as masks and age distribution, predictions of new infections (mean), situational R-values (mean), and individual risks on- and off-seat can be achieved for the first time. Using the Stuttgart State Opera as an example, the functioning of the model and its plausibility are tested and a sensitivity analysis is performed with regard to masks and tests. Besides a reference scenario on 2022-11-29, a maximum safety scenario with an obligation of FFP2 masks and rapid antigen tests as well as a minimum safety scenario without masks and tests are investigated. For these scenarios the new infections (mean) are 10.6, 0.25 and 13.0, respectively. The situational R-values (mean) – number of new infections caused by a single infectious person in a certain situation – are 2.75, 0.32 and 3.39, respectively. Besides these results a clustered consideration divided by age, masks and whether infections occur on-seat or off-seat are presented. In conclusion this provides an instrument that can enable policymakers and operators to take appropriate measures to control pandemics despite ongoing mass gathering events.
- 20 July 2023
- Published by Springer Nature in BMC Public Health
- Vol. 23 (1) , 1-19
Open AccessA coupled experimental and statistical approach for an assessment of SARS-CoV-2 infection risk at indoor event locations
Indoor event locations are particularly affected by the SARS-CoV-2 pandemic. At large venues, only incomplete risk assessments exist, whereby no suitable measures can be derived. In this study, a physical and data-driven statistical model for a comprehensive infection risk assessment has been developed. At venues displacement ventilation concepts are often implemented. Here simplified theoretical assumptions fail for the prediction of relevant airflows for airborne transmission processes. Thus, with locally resolving trace gas measurements infection risks are computed more detailed. Coupled with epidemiological data such as incidences, vaccination rates, test sensitivities, and audience characteristics such as masks and age distribution, predictions of new infections (mean), situational R-values (mean), and individual risks on- and off-seat can be achieved for the first time. Using the Stuttgart State Opera as an example, the functioning of the model and its plausibility are tested and a sensitivity analysis is performed with regard to masks and tests. Besides a reference scenario on 2022-11-29, a maximum safety scenario with an obligation of FFP2 masks and rapid antigen tests as well as a minimum safety scenario without masks and tests are investigated. For these scenarios the new infections (mean) are 10.6, 0.25 and 13.0, respectively. The situational R-values (mean) – number of new infections caused by a single infectious person in a certain situation – are 2.75, 0.32 and 3.39, respectively. Besides these results a clustered consideration divided by age, masks and whether infections occur on-seat or off-seat are presented. In conclusion this provides an instrument that can enable policymakers and operators to take appropriate measures to control pandemics despite ongoing mass gathering events.
- Open Access
- 8 September 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (18) , 11300
Experimental Methods of Investigating Airborne Indoor Virus-Transmissions Adapted to Several Ventilation Measures
This study introduces a principle that unifies two experimental methods for evaluating airborne indoor virus-transmissions adapted to several ventilation measures. A first-time comparison of mechanical/natural ventilation and air purification with regard to infection risks is enabled. Effortful computational fluid dynamics demand detailed boundary conditions for accurate calculations of indoor airflows, which are often unknown. Hence, a suitable, simple and generalized experimental set up for identifying the spatial and temporal infection risk for different ventilation measures is more qualified even with unknown boundary conditions. A trace gas method is suitable for mechanical and natural ventilation with outdoor air exchange. For an accurate assessment of air purifiers based on filtration, a surrogate particle method is appropriate. The release of a controlled rate of either trace gas or particles simulates an infectious person releasing virus material. Surrounding substance concentration measurements identify the neighborhood exposure. One key aspect of the study is to prove that the requirement of concordant results of both methods is fulfilled. This is the only way to ensure that the comparison of different ventilation measures described above is reliable. Two examples (a two-person office and a classroom) show how practical both methods are and how the principle is applicable for different types and sizes of rooms.
- 8 September 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (18) , 11300
Open AccessExperimental Methods of Investigating Airborne Indoor Virus-Transmissions Adapted to Several Ventilation Measures
This study introduces a principle that unifies two experimental methods for evaluating airborne indoor virus-transmissions adapted to several ventilation measures. A first-time comparison of mechanical/natural ventilation and air purification with regard to infection risks is enabled. Effortful computational fluid dynamics demand detailed boundary conditions for accurate calculations of indoor airflows, which are often unknown. Hence, a suitable, simple and generalized experimental set up for identifying the spatial and temporal infection risk for different ventilation measures is more qualified even with unknown boundary conditions. A trace gas method is suitable for mechanical and natural ventilation with outdoor air exchange. For an accurate assessment of air purifiers based on filtration, a surrogate particle method is appropriate. The release of a controlled rate of either trace gas or particles simulates an infectious person releasing virus material. Surrounding substance concentration measurements identify the neighborhood exposure. One key aspect of the study is to prove that the requirement of concordant results of both methods is fulfilled. This is the only way to ensure that the comparison of different ventilation measures described above is reliable. Two examples (a two-person office and a classroom) show how practical both methods are and how the principle is applicable for different types and sizes of rooms.
- Open Access
Real-Time Grid Signal-Based Energy Flexibility of Heating Generation: A Methodology for Optimal Scheduling of Stratified Storage Tanks
Heat pumps coupled with thermal energy storage (TES) systems are seen as a promising technology for load management that can be used to shift peak loads to off-peak hours. Most of the existing model predictive control (MPC) studies on tariff-based load shifting deploying hot water tanks use simplified tank models. In this study, an MPC framework that accounts for transient thermal behavior (i.e., mixing and stratification) by applying energy (EMPC) and exergy (XMPC) analysis is proposed. A case study for an office building equipped with an air handling unit (AHU) revealed that the MPC strategy had a high load-shifting capacity: over 80% of the energy consumption took place during off-peak hours when there was an electricity surplus in the grid. An analysis of a typical day showed that the XMPC method was able to provide more appropriate stratification within the TES for all load characteristics. An annual exergy analysis demonstrated that, during cold months, energy degradation in the TES is mainly caused by exergy destruction due to irreversibility, while, during the transition to milder months, exergy loss dominates. Compared to the EMPC approach, the XMPC strategy achieves additional reductions of 18% in annual electricity consumption, 13% in operating costs, and almost 17% in emissions.
Open AccessReal-Time Grid Signal-Based Energy Flexibility of Heating Generation: A Methodology for Optimal Scheduling of Stratified Storage Tanks
Heat pumps coupled with thermal energy storage (TES) systems are seen as a promising technology for load management that can be used to shift peak loads to off-peak hours. Most of the existing model predictive control (MPC) studies on tariff-based load shifting deploying hot water tanks use simplified tank models. In this study, an MPC framework that accounts for transient thermal behavior (i.e., mixing and stratification) by applying energy (EMPC) and exergy (XMPC) analysis is proposed. A case study for an office building equipped with an air handling unit (AHU) revealed that the MPC strategy had a high load-shifting capacity: over 80% of the energy consumption took place during off-peak hours when there was an electricity surplus in the grid. An analysis of a typical day showed that the XMPC method was able to provide more appropriate stratification within the TES for all load characteristics. An annual exergy analysis demonstrated that, during cold months, energy degradation in the TES is mainly caused by exergy destruction due to irreversibility, while, during the transition to milder months, exergy loss dominates. Compared to the EMPC approach, the XMPC strategy achieves additional reductions of 18% in annual electricity consumption, 13% in operating costs, and almost 17% in emissions.
- Open Access
A Coupled Experimental and Statistical Approach for an Assessment of the Airborne Infection Risk in Event Locations
Operators of event locations are particularly affected by a pandemic. Resulting restrictions may cause uneconomical business. With previous models, only an incomplete quantitative risk assessments is possible, whereby no suitable restrictions can be derived. Hence, a mathematical and statistical model has been developed in order to link measurement data of substance dispersion in rooms with epidemiological data like incidences, reproduction numbers, vaccination rates and test qualities. This allows a first time overall assessment of airborne infection risks in large event locations. In these venues displacement ventilation concepts are often implemented. In this case simplified theoretical assumptions fail for the prediction of relevant airflows for infection processes. Thus, with locally resolving trace gas measurements and specific data of infection processes, individual risks can be computed more detailed. Via inclusion of many measurement positions, an assessment of entire event locations is possible. Embedding the overall model in a flexible application, daily updated epidemiological data allow latest calculations of expected new infections and individual risks of single visitors for a certain event. With this model, an instrument has been created that can help policymakers and operators to take appropriate measures and to check restrictions for their effect.
Open AccessA Coupled Experimental and Statistical Approach for an Assessment of the Airborne Infection Risk in Event Locations
Operators of event locations are particularly affected by a pandemic. Resulting restrictions may cause uneconomical business. With previous models, only an incomplete quantitative risk assessments is possible, whereby no suitable restrictions can be derived. Hence, a mathematical and statistical model has been developed in order to link measurement data of substance dispersion in rooms with epidemiological data like incidences, reproduction numbers, vaccination rates and test qualities. This allows a first time overall assessment of airborne infection risks in large event locations. In these venues displacement ventilation concepts are often implemented. In this case simplified theoretical assumptions fail for the prediction of relevant airflows for infection processes. Thus, with locally resolving trace gas measurements and specific data of infection processes, individual risks can be computed more detailed. Via inclusion of many measurement positions, an assessment of entire event locations is possible. Embedding the overall model in a flexible application, daily updated epidemiological data allow latest calculations of expected new infections and individual risks of single visitors for a certain event. With this model, an instrument has been created that can help policymakers and operators to take appropriate measures and to check restrictions for their effect.