Qi Zhang
Qi Zhang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Hongguang Pan
College of Electrical and Control Engineering, Xi’an University of Science and Technology, Xi’an, China
2 shared publications - Haoqian Song
State Key Laboratory of Multimodal Artificial Intelligence Systems, Institute of Automation, Chinese Academy of Sciences, Beijing, China
1 shared publication - Jingyuan Zhang
College of Electrical and Control Engineering, Xi’an University of Science and Technology, Xi’an, China
1 shared publication - Wenyu Mi
National Key Laboratory of Human-Machine Hybrid Augmented Intelligence, the National Engineering Research Center for Visual Information and Applications, and the Institute of Artificial Intelligence and Robotics, Xian Jiaotong University, Xian, China
1 shared publication - Xuebin Qin
College of Electrical and Control Engineering, Xi’an University of Science And Technology, Xi’an 710054, China
1 shared publication - Yunpeng Fu
College of Electrical and Control Engineering, Xi’an University of Science and Technology, Xi’an, China
1 shared publication
Latest Publications
- 23 December 2022
- Published by Springer Nature in Cognitive Neurodynamics
- Vol. 18 (1) , 147-164
The decoder design and performance comparative analysis for closed-loop brain–machine interface system
Brain–machine interface (BMI) can convert electroencephalography signals (EEGs) into the control instructions of external devices, and the key of control performance is the accuracy and efficiency of decoder. However, the performance of different decoders obtaining control instructions from complex and variable EEG signals is very different and irregular in the different neural information transfer model. Aiming at this problem, the off-line and on-line performance of eight decoders based on the improved single-joint information transmission (SJIT) model is compared and analyzed in this paper, which can provide a theoretical guidance for decoder design. Firstly, in order to avoid the different types of neural activities in the decoding process on the decoder performance, eight decoders based on the improved SJIT model are designed. And then the off-line decoding performance of these decoders is tested and compared. Secondly, a closed-loop BMI system which combining by the designed decoder and the random forest encoder based on the improved SJIT model is constructed. Finally, based on the constructed closed-loop BMI system, the on-line decoding performance of decoders is compared and analyzed. The results show that the LSTM-based decoder has better on-line decoding performance than others in the improved SJIT model.
- 23 December 2022
- Published by Springer Nature in Cognitive Neurodynamics
- Vol. 18 (1) , 147-164
The decoder design and performance comparative analysis for closed-loop brain–machine interface system
Brain–machine interface (BMI) can convert electroencephalography signals (EEGs) into the control instructions of external devices, and the key of control performance is the accuracy and efficiency of decoder. However, the performance of different decoders obtaining control instructions from complex and variable EEG signals is very different and irregular in the different neural information transfer model. Aiming at this problem, the off-line and on-line performance of eight decoders based on the improved single-joint information transmission (SJIT) model is compared and analyzed in this paper, which can provide a theoretical guidance for decoder design. Firstly, in order to avoid the different types of neural activities in the decoding process on the decoder performance, eight decoders based on the improved SJIT model are designed. And then the off-line decoding performance of these decoders is tested and compared. Secondly, a closed-loop BMI system which combining by the designed decoder and the random forest encoder based on the improved SJIT model is constructed. Finally, based on the constructed closed-loop BMI system, the on-line decoding performance of decoders is compared and analyzed. The results show that the LSTM-based decoder has better on-line decoding performance than others in the improved SJIT model.
- 11 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Human-Machine Systems
- Vol. 52 (5) , 877-893
Review of Closed-Loop Brain–Machine Interface Systems From a Control Perspective
In recent years, brain–machine interface (BMI) technology has made great progress in controlling external devices and restoring motor function for people with disabilities. To better optimize BMI system performance, in this article, we summarize and describe a universal closed-loop BMI system framework and review the latest developments over the past ten years from a control perspective. First, the basic BMI systems with open-loop and closed-loop structures are introduced in chronological order. Second, the units of the universal closed-loop BMI system, i.e., the decoder, encoder, and auxiliary controller, are reviewed and summarized in terms of principles, categories, and algorithms. Finally, from research and practical perspectives, the importance of biomimetic brain models, great challenges, and future developments are discussed based on current progress. With this analysis of the universal closed-loop framework, this review can provide necessary theoretical guidance for the research and development of BMI systems.
- 11 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Human-Machine Systems
- Vol. 52 (5) , 877-893
Review of Closed-Loop Brain–Machine Interface Systems From a Control Perspective
In recent years, brain–machine interface (BMI) technology has made great progress in controlling external devices and restoring motor function for people with disabilities. To better optimize BMI system performance, in this article, we summarize and describe a universal closed-loop BMI system framework and review the latest developments over the past ten years from a control perspective. First, the basic BMI systems with open-loop and closed-loop structures are introduced in chronological order. Second, the units of the universal closed-loop BMI system, i.e., the decoder, encoder, and auxiliary controller, are reviewed and summarized in terms of principles, categories, and algorithms. Finally, from research and practical perspectives, the importance of biomimetic brain models, great challenges, and future developments are discussed based on current progress. With this analysis of the universal closed-loop framework, this review can provide necessary theoretical guidance for the research and development of BMI systems.