Fabrice Seguin

Fabrice Seguin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Fabrice Seguin has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Scintillation in Liquid Xenon for Gamma-Ray Medical Imaging: From Single Time-over-Threshold to Multi-Time-over-Threshold PMT Signal Measurements

    by Quentin Lainé, Nicolas Beaupere, Dingbang Cai, Eric Morteau, Fabrice Seguin, Dominique Thers, Cyril Lahuec

    In this paper, a new light event acquisition chain in a three-gamma liquid xenon prototype for medical nuclear imaging is presented. The prototype implements the Multi-Time-Over-Threshold (MTOT) method. This method surpasses the Single-Time-Over-Threshold (STOT) by precisely determining both the number of vacuum ultraviolet (VUV) photons detected by each photomultiplier tube (PMT) and their arrival times for light signal measurement. Based on both the experimental and simulated results, the MTOT method achieved a 70% improvement in reconstructing photoelectrons (PEs) and enhanced the precision of the arrival time estimation by 20–30% compared with STOT. These results will enable an upgrade of the XEMIS2 (Xenon Medical Imaging System) camera, improving its performance as the imaged activity increases.

  • Open Access

    Multipurpose Bio-Monitored Integrated Circuit in a Contact Lens Eye-Tracker

    by Loïc Massin, Cyril Lahuec, Fabrice Seguin, Vincent Nourrit, Jean-Louis de Bougrenet de la Tocnaye

    We present the design, fabrication, and test of a multipurpose integrated circuit (Application Specific Integrated Circuit) in AMS 0.35 µm Complementary Metal Oxide Semiconductor technology. This circuit is embedded in a scleral contact lens, combined with photodiodes enabling the gaze direction detection when illuminated and wirelessly powered by an eyewear. The gaze direction is determined by means of a centroid computation from the measured photocurrents. The ASIC is used simultaneously to detect specific eye blinking sequences to validate target designations, for instance. Experimental measurements and validation are performed on a scleral contact lens prototype integrating four infrared photodiodes, mounted on a mock-up eyeball, and combined with an artificial eyelid. The eye-tracker has an accuracy of 0.2°, i.e., 2.5 times better than current mobile video-based eye-trackers, and is robust with respect to process variations, operating time, and supply voltage. Variations of the computed gaze direction transmitted to the eyewear, when the eyelid moves, are detected and can be interpreted as commands based on blink duration or using blinks alternation on both eyes.