Taku Sakamoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Taku Sakamoto has a total of 150 co-authors. Here are the top co-authors by number of shared publications:
- Yutaka Saito
National Cancer Center Hospital, Tokyo, Japan
30 shared publications Takahisa Matsuda
Endoscopy Division, National Cancer Center Hospital, Tokyo, Japan
17 shared publications- Masayoshi Yamada
Endoscopy Division, National Cancer Center Hospital, Tokyo, Japan
13 shared publications - Takahisa Matsuda
Toho University Omori Medical Center, Japan
13 shared publications Takeshi Nakajima
Endoscopy Division, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan
13 shared publicationsYutaka Saito
Endoscopy Division, National Cancer Center Hospital
13 shared publications
Latest Publications
- Open Access
- 17 September 2026
- Published by Georg Thieme Verlag KG in Endoscopy
Diagnostic performance of the Japan Narrow-Band Imaging Expert Team and pit pattern classifications for small polyps using next-generation endoscopy
Background and study aims Optical diagnosis of small colorectal lesions is important for the potential implementation of “resect-and-discard” and “leave-in-situ” strategies. We evaluated the performance of the Japan Narrow-Band Imaging Expert Team (JNET) and pit pattern classifications in differentiating small adenomatous and serrated colorectal lesions using a modern high-definition endoscopy system (EVIS X1), with outcomes stratified by endoscopist expertise. Patients and methods This secondary analysis of the prospective multicenter deTXIon trial included 1,830 colorectal lesions for JNET evaluation, of which 92.9% measured <10 mm, and 1,601 lesions for pit pattern evaluation. Adenocarcinomas were excluded. Sensitivity, specificity, positive and negative predictive values, and likelihood ratios were calculated. To account for multiple lesions within the same patient, 95% confidence intervals (CIs) were estimated using a cluster bootstrap approach with patients as the resampling unit. Exploratory expert–non-expert differences in sensitivity, specificity, and negative predictive value were also estimated. Results JNET showed high diagnostic performance, with no clear between-group differences in sensitivity, specificity, or negative predictive value. For pit pattern classification, expert–non-expert differences were 5.01 percentage points for sensitivity (95% CI, 1.23–9.08) and 10.00 percentage points for negative predictive value (95% CI, 1.37–18.56). Conclusions JNET showed similar observed diagnostic performance across expertise levels, whereas pit pattern classification showed greater between-group differences in sensitivity and negative predictive value. These findings suggest that JNET may serve as a practical framework for routine optical diagnosis of small lesions.
- 17 September 2026
- Published by Georg Thieme Verlag KG in Endoscopy
Open AccessDiagnostic performance of the Japan Narrow-Band Imaging Expert Team and pit pattern classifications for small polyps using next-generation endoscopy
Background and study aims Optical diagnosis of small colorectal lesions is important for the potential implementation of “resect-and-discard” and “leave-in-situ” strategies. We evaluated the performance of the Japan Narrow-Band Imaging Expert Team (JNET) and pit pattern classifications in differentiating small adenomatous and serrated colorectal lesions using a modern high-definition endoscopy system (EVIS X1), with outcomes stratified by endoscopist expertise. Patients and methods This secondary analysis of the prospective multicenter deTXIon trial included 1,830 colorectal lesions for JNET evaluation, of which 92.9% measured <10 mm, and 1,601 lesions for pit pattern evaluation. Adenocarcinomas were excluded. Sensitivity, specificity, positive and negative predictive values, and likelihood ratios were calculated. To account for multiple lesions within the same patient, 95% confidence intervals (CIs) were estimated using a cluster bootstrap approach with patients as the resampling unit. Exploratory expert–non-expert differences in sensitivity, specificity, and negative predictive value were also estimated. Results JNET showed high diagnostic performance, with no clear between-group differences in sensitivity, specificity, or negative predictive value. For pit pattern classification, expert–non-expert differences were 5.01 percentage points for sensitivity (95% CI, 1.23–9.08) and 10.00 percentage points for negative predictive value (95% CI, 1.37–18.56). Conclusions JNET showed similar observed diagnostic performance across expertise levels, whereas pit pattern classification showed greater between-group differences in sensitivity and negative predictive value. These findings suggest that JNET may serve as a practical framework for routine optical diagnosis of small lesions.
- Open Access
Comparison of Detection Yields Between Texture and Color Enhancement Imaging Mode 1 and Mode 2 for Colorectal Lesions: A Post‐hoc Analysis of a Multicenter Observational Study
Objectives: Colonoscopy is a reliable technique for the detection, diagnosis, and treatment of adenomas and early cancer. Image‐enhanced endoscopy (IEE) is important for detecting colorectal lesions. Texture and color‐enhancement imaging (TXI) has recently emerged as a novel modality for IEE. Thus, TXI operates in two modes: mode 1 (TXI1) enhances the structure, color, and brightness, whereas mode 2 (TXI2) does not. We have previously reported the detection of colorectal adenomas using TXI. We aimed to determine the detection yields of TXI1 and TXI2 using the data from our previous study. Methods: We retrospectively analyzed the colonoscopy data from three institutions between August 2020 and January 2021. The patients were classified into two groups: TXI1 and TXI2. The mean number of adenomas detected per procedure (MAP), adenoma detection rate (ADR), and flat adenoma detection rate (FDR) were compared between groups. Results: The evaluations (95% confidence intervals) for the TXI1 versus TXI2 groups were as follows: MAP, 1.5 (1.3–1.7) versus 1.5 (1.3–1.7); ADR, 56.8% (47.3–65.9) versus 59.7% (50.3–68.6); and FDR, 68.6% (59.5–76.9) versus 63.9% (54.6–72.5), with no statistically significant differences between the groups. Conclusion: The detection rates of colorectal lesions were comparable between the TXI1 and TXI2 groups.
Open AccessComparison of Detection Yields Between Texture and Color Enhancement Imaging Mode 1 and Mode 2 for Colorectal Lesions: A Post‐hoc Analysis of a Multicenter Observational Study
Objectives: Colonoscopy is a reliable technique for the detection, diagnosis, and treatment of adenomas and early cancer. Image‐enhanced endoscopy (IEE) is important for detecting colorectal lesions. Texture and color‐enhancement imaging (TXI) has recently emerged as a novel modality for IEE. Thus, TXI operates in two modes: mode 1 (TXI1) enhances the structure, color, and brightness, whereas mode 2 (TXI2) does not. We have previously reported the detection of colorectal adenomas using TXI. We aimed to determine the detection yields of TXI1 and TXI2 using the data from our previous study. Methods: We retrospectively analyzed the colonoscopy data from three institutions between August 2020 and January 2021. The patients were classified into two groups: TXI1 and TXI2. The mean number of adenomas detected per procedure (MAP), adenoma detection rate (ADR), and flat adenoma detection rate (FDR) were compared between groups. Results: The evaluations (95% confidence intervals) for the TXI1 versus TXI2 groups were as follows: MAP, 1.5 (1.3–1.7) versus 1.5 (1.3–1.7); ADR, 56.8% (47.3–65.9) versus 59.7% (50.3–68.6); and FDR, 68.6% (59.5–76.9) versus 63.9% (54.6–72.5), with no statistically significant differences between the groups. Conclusion: The detection rates of colorectal lesions were comparable between the TXI1 and TXI2 groups.
- Open Access
Diagnostic Concordance Using Japan Narrow‐band Imaging Expert Team Classification for Diagnosing Colorectal Neoplasms: A Web‐based Diagnostic Concordance Study
Objectives: The Japan Narrow‐band Imaging Expert Team (JNET) classification is widely used for magnified endoscopic diagnosis of colorectal neoplasms. However, its diagnostic concordance, particularly among the core members who contributed to its development, has not been sufficiently evaluated. Therefore, this study aimed to assess the diagnostic concordance of the JNET classification among JNET core members using a web‐based image interpretation test. Methods: A total of 27 JNET core members performed a web‐based static image reading test in two separate sessions. Each image was classified according to the JNET criteria, and the diagnostic concordance rate (DCR) was analyzed. Cases were categorized as having high (≥80% consensus), moderate (70%–79% consensus), or low (85%) than for neoplastic lesions. In the first session, the DCR for neoplastic lesions was substantially lower, with 54% for low‐grade intramucosal neoplasia, 63% for high‐grade intramucosal neoplasia/T1a, and 52% for T1b. The classification of T1b lesions showed notable variability. Further, while secondary findings influenced classification, this remained an exploratory analysis rather than a primary outcome. Conclusions: While the JNET classification demonstrated high diagnostic concordance for SSL/HP, variability remained in neoplastic lesions, particularly in T1b cancer. These findings highlight the need for further refinement of the classification system to improve its diagnostic concordance in clinical practice.
Open AccessDiagnostic Concordance Using Japan Narrow‐band Imaging Expert Team Classification for Diagnosing Colorectal Neoplasms: A Web‐based Diagnostic Concordance Study
Objectives: The Japan Narrow‐band Imaging Expert Team (JNET) classification is widely used for magnified endoscopic diagnosis of colorectal neoplasms. However, its diagnostic concordance, particularly among the core members who contributed to its development, has not been sufficiently evaluated. Therefore, this study aimed to assess the diagnostic concordance of the JNET classification among JNET core members using a web‐based image interpretation test. Methods: A total of 27 JNET core members performed a web‐based static image reading test in two separate sessions. Each image was classified according to the JNET criteria, and the diagnostic concordance rate (DCR) was analyzed. Cases were categorized as having high (≥80% consensus), moderate (70%–79% consensus), or low (85%) than for neoplastic lesions. In the first session, the DCR for neoplastic lesions was substantially lower, with 54% for low‐grade intramucosal neoplasia, 63% for high‐grade intramucosal neoplasia/T1a, and 52% for T1b. The classification of T1b lesions showed notable variability. Further, while secondary findings influenced classification, this remained an exploratory analysis rather than a primary outcome. Conclusions: While the JNET classification demonstrated high diagnostic concordance for SSL/HP, variability remained in neoplastic lesions, particularly in T1b cancer. These findings highlight the need for further refinement of the classification system to improve its diagnostic concordance in clinical practice.
- Open Access
Advancements and limitations of image‐enhanced endoscopy in colorectal lesion diagnosis and treatment selection: A narrative review
Colorectal cancer (CRC) is a leading cause of cancer‐related mortality, highlighting the need for early detection and accurate lesion characterization. Traditional white‐light imaging has limitations in detecting lesions, particularly those with flat morphology or minimal color contrast with the surrounding mucosa. It also struggles to distinguish neoplastic from non‐neoplastic lesions. These limitations led to the development of image‐enhanced endoscopy (IEE). Image‐enhanced endoscopy modalities such as narrow‐band imaging, blue laser imaging, linked color imaging, and texture and color enhancement imaging enhance mucosal surface and vascular pattern visualization, thereby improving lesion detection and characterization. In contrast, red dichromatic imaging is primarily designed to enhance the visibility of deep blood vessels, making it particularly useful during therapeutic endoscopies, such as identifying bleeding sources and monitoring post‐treatment hemostasis. Although IEE enhances lesion detection and characterization, it remains limited in assessing submucosal invasion depth, which is a key factor in treatment decisions. Endoscopic submucosal dissection requires accurate prediction of invasion depth; however, IEE mainly reflects superficial features. Endoscopic ultrasound and artificial intelligence‐assisted diagnostics have emerged as complementary techniques for improving depth assessment and lesion classification. Additionally, IEE plays a critical role in detecting ulcerative colitis‐associated neoplasia (UCAN), which often presents with a flat morphology and indistinct borders. High‐definition chromoendoscopy and IEE modalities enhance detection; however, inflammation‐related changes limit diagnostic accuracy. Artificial intelligence and molecular biomarkers may improve UCAN diagnosis. This review examines the role of IEE in lesion detection and treatment selection, its limitations, and complementary techniques such as endoscopic ultrasound and artificial intelligence. We also explored pit pattern diagnosis using crystal violet staining and discussed emerging strategies to refine colorectal cancer screening and management.
Open AccessAdvancements and limitations of image‐enhanced endoscopy in colorectal lesion diagnosis and treatment selection: A narrative review
Colorectal cancer (CRC) is a leading cause of cancer‐related mortality, highlighting the need for early detection and accurate lesion characterization. Traditional white‐light imaging has limitations in detecting lesions, particularly those with flat morphology or minimal color contrast with the surrounding mucosa. It also struggles to distinguish neoplastic from non‐neoplastic lesions. These limitations led to the development of image‐enhanced endoscopy (IEE). Image‐enhanced endoscopy modalities such as narrow‐band imaging, blue laser imaging, linked color imaging, and texture and color enhancement imaging enhance mucosal surface and vascular pattern visualization, thereby improving lesion detection and characterization. In contrast, red dichromatic imaging is primarily designed to enhance the visibility of deep blood vessels, making it particularly useful during therapeutic endoscopies, such as identifying bleeding sources and monitoring post‐treatment hemostasis. Although IEE enhances lesion detection and characterization, it remains limited in assessing submucosal invasion depth, which is a key factor in treatment decisions. Endoscopic submucosal dissection requires accurate prediction of invasion depth; however, IEE mainly reflects superficial features. Endoscopic ultrasound and artificial intelligence‐assisted diagnostics have emerged as complementary techniques for improving depth assessment and lesion classification. Additionally, IEE plays a critical role in detecting ulcerative colitis‐associated neoplasia (UCAN), which often presents with a flat morphology and indistinct borders. High‐definition chromoendoscopy and IEE modalities enhance detection; however, inflammation‐related changes limit diagnostic accuracy. Artificial intelligence and molecular biomarkers may improve UCAN diagnosis. This review examines the role of IEE in lesion detection and treatment selection, its limitations, and complementary techniques such as endoscopic ultrasound and artificial intelligence. We also explored pit pattern diagnosis using crystal violet staining and discussed emerging strategies to refine colorectal cancer screening and management.
- Open Access
- 30 September 2024
- Published by The Korean Society of Gastrointestinal Endoscopy in Clinical Endoscopy
- Vol. 57 (5) , 628-636
Efficacy of hemostasis by gastroduodenal covered metal stent placement for hemorrhagic duodenal stenosis due to pancreatobiliary cancer invasion: a retrospective study
Background/Aims: Advanced pancreatic and biliary tract cancers can invade the duodenum and cause duodenal hemorrhagic stenosis. This study aimed to evaluate the efficacy of covered self-expandable metal stents in the treatment of cancer-related duodenal hemorrhage with stenosis.Methods: Between January 2014 and December 2016, metal stents were placed in 51 patients with duodenal stenosis. Among these patients, a self-expandable covered metal stent was endoscopically placed in 10 patients with hemorrhagic duodenal stenosis caused by pancreatobiliary cancer progression. We retrospectively analyzed the therapeutic efficacy of the stents by evaluating the technical and clinical success rates based on successful stent placement, degree of oral intake, hemostasis, stent patency, and overall survival.Results: The technical and clinical success rates were 100%. All 10 patients achieved a gastric outlet obstruction scoring system score of three within two weeks after the procedure and had no recurrence of melena. The median stent patency duration and overall survival after stent placement were 52 days (range, 20–220 days) and 66.5 days (range, 31–220 days), respectively.Conclusions: Endoscopic placement of a covered metal stent for hemorrhagic duodenal stenosis associated with pancreatic or biliary tract cancer resulted in duodenal hemostasis, recanalization, and improved quality of life.
- 30 September 2024
- Published by The Korean Society of Gastrointestinal Endoscopy in Clinical Endoscopy
- Vol. 57 (5) , 628-636
Open AccessEfficacy of hemostasis by gastroduodenal covered metal stent placement for hemorrhagic duodenal stenosis due to pancreatobiliary cancer invasion: a retrospective study
Background/Aims: Advanced pancreatic and biliary tract cancers can invade the duodenum and cause duodenal hemorrhagic stenosis. This study aimed to evaluate the efficacy of covered self-expandable metal stents in the treatment of cancer-related duodenal hemorrhage with stenosis.Methods: Between January 2014 and December 2016, metal stents were placed in 51 patients with duodenal stenosis. Among these patients, a self-expandable covered metal stent was endoscopically placed in 10 patients with hemorrhagic duodenal stenosis caused by pancreatobiliary cancer progression. We retrospectively analyzed the therapeutic efficacy of the stents by evaluating the technical and clinical success rates based on successful stent placement, degree of oral intake, hemostasis, stent patency, and overall survival.Results: The technical and clinical success rates were 100%. All 10 patients achieved a gastric outlet obstruction scoring system score of three within two weeks after the procedure and had no recurrence of melena. The median stent patency duration and overall survival after stent placement were 52 days (range, 20–220 days) and 66.5 days (range, 31–220 days), respectively.Conclusions: Endoscopic placement of a covered metal stent for hemorrhagic duodenal stenosis associated with pancreatic or biliary tract cancer resulted in duodenal hemostasis, recanalization, and improved quality of life.
- Open Access
Exploratory investigation of virtual lesions in gastrointestinal endoscopy using a novel phase‐shift method for three‐dimensional shape measurement
Accurate measurement of the size of lesions or distances between any two points during endoscopic examination of the gastrointestinal tract is difficult owing to the fisheye lens used in endoscopy. To overcome this issue, we developed a phase‐shift method to measure three‐dimensional (3D) data on a curved surface, which we present herein. Our system allows the creation of 3D shapes on a curved surface by the phase‐shift method using a stripe pattern projected from a small projecting device to an object. For evaluation, 88 measurement points were inserted in porcine stomach tissue, attached to a half‐pipe jig, with an inner radius of 21 mm. The accuracy and precision of the measurement data for our shape measurement system were compared with the data obtained using an Olympus STM6 measurement microscope. The accuracy of the path length of a simulated protruded lesion was evaluated using a plaster model of the curved stomach and graph paper. The difference in height measures between the measurement microscope and measurement system data was 0.24 mm for the 88 measurement points on the curved surface of the porcine stomach. The error in the path length measurement for a lesion on an underlying curved surface was <1% for a 10‐mm lesion. The software was developed for the automated calculation of the major and minor diameters of each lesion. The accuracy of our measurement system could improve the accuracy of determining the size of lesions, whether protruded or depressed, regardless of the curvature of the underlying surface.
Open AccessExploratory investigation of virtual lesions in gastrointestinal endoscopy using a novel phase‐shift method for three‐dimensional shape measurement
Accurate measurement of the size of lesions or distances between any two points during endoscopic examination of the gastrointestinal tract is difficult owing to the fisheye lens used in endoscopy. To overcome this issue, we developed a phase‐shift method to measure three‐dimensional (3D) data on a curved surface, which we present herein. Our system allows the creation of 3D shapes on a curved surface by the phase‐shift method using a stripe pattern projected from a small projecting device to an object. For evaluation, 88 measurement points were inserted in porcine stomach tissue, attached to a half‐pipe jig, with an inner radius of 21 mm. The accuracy and precision of the measurement data for our shape measurement system were compared with the data obtained using an Olympus STM6 measurement microscope. The accuracy of the path length of a simulated protruded lesion was evaluated using a plaster model of the curved stomach and graph paper. The difference in height measures between the measurement microscope and measurement system data was 0.24 mm for the 88 measurement points on the curved surface of the porcine stomach. The error in the path length measurement for a lesion on an underlying curved surface was <1% for a 10‐mm lesion. The software was developed for the automated calculation of the major and minor diameters of each lesion. The accuracy of our measurement system could improve the accuracy of determining the size of lesions, whether protruded or depressed, regardless of the curvature of the underlying surface.
- Open Access
- 1 March 2024
- Published by Wolters Kluwer Health in Medicine
- Vol. 103 (9) , e36335
A novel predictive formula for highly accurate discrimination between truly Helicobacter pylori-uninfected and currently infected/spontaneously eradicated individuals for gastric cancer screening
The ABC classification, which categorizes gastric cancer risk based on serum Helicobacter pylori (H pylori) antibody and pepsinogen levels, has a limitation of potentially misclassifying high-risk individuals as low risk. To overcome the problem, we previously developed a 4-parameter predictive formula (age, serum H pylori antibody, PGI, and PGII) using logistic regression analysis to accurately identify low-risk truly H pylori-uninfected status. Our predictive formula demonstrated superior sensitivity and specificity in distinguishing between low-risk truly uninfected individuals and high-risk currently/spontaneously eradicated status individuals, compared to the modified ABC classification based on latex immunoassay kits (traditional 3-parameter model). This study aimed to revalidate the diagnostic accuracy of the predictive formula in a new and different study population. We applied the predictive formula to the target population and compared the sensitivity and specificity with those of the traditional 3-parameter model. A total of 788 enrollees were analyzed: 703 were classified as truly uninfected, 45 as currently infected, and 40 as spontaneously eradicated according to the results of stool antigen testing and endoscopic findings. The sensitivities and specificities of the predictive formula and the traditional 3-parameter model were 89.5% and 87.1% versus 89.8% and 80.0%, respectively. The specificity of the predictive formula was superior in the 70 to 89 age range and H pylori antibody < 3 U/mL groups. The predictive formula had higher specificity than the traditional 3-parameter model. The results should contribute to efficient gastric cancer screening by predicting H pylori infection status.
- 1 March 2024
- Published by Wolters Kluwer Health in Medicine
- Vol. 103 (9) , e36335
Open AccessA novel predictive formula for highly accurate discrimination between truly Helicobacter pylori-uninfected and currently infected/spontaneously eradicated individuals for gastric cancer screening
The ABC classification, which categorizes gastric cancer risk based on serum Helicobacter pylori (H pylori) antibody and pepsinogen levels, has a limitation of potentially misclassifying high-risk individuals as low risk. To overcome the problem, we previously developed a 4-parameter predictive formula (age, serum H pylori antibody, PGI, and PGII) using logistic regression analysis to accurately identify low-risk truly H pylori-uninfected status. Our predictive formula demonstrated superior sensitivity and specificity in distinguishing between low-risk truly uninfected individuals and high-risk currently/spontaneously eradicated status individuals, compared to the modified ABC classification based on latex immunoassay kits (traditional 3-parameter model). This study aimed to revalidate the diagnostic accuracy of the predictive formula in a new and different study population. We applied the predictive formula to the target population and compared the sensitivity and specificity with those of the traditional 3-parameter model. A total of 788 enrollees were analyzed: 703 were classified as truly uninfected, 45 as currently infected, and 40 as spontaneously eradicated according to the results of stool antigen testing and endoscopic findings. The sensitivities and specificities of the predictive formula and the traditional 3-parameter model were 89.5% and 87.1% versus 89.8% and 80.0%, respectively. The specificity of the predictive formula was superior in the 70 to 89 age range and H pylori antibody < 3 U/mL groups. The predictive formula had higher specificity than the traditional 3-parameter model. The results should contribute to efficient gastric cancer screening by predicting H pylori infection status.
- Open Access
- 31 January 2024
- Published by Korean Association for the Study of Intestinal Diseases in Intestinal Research
- Vol. 22 (1) , 92-103
Association of colonic metaplasia of goblet cells and endoscopic phenotypes of the J pouch in patients with ulcerative colitis: a retrospective pilot study
Background/Aims: Mucosal adaptation of the ileum toward colonic epithelium has been reported in pouchitis in ulcerative colitis (UC); however, the clinical characteristics, endoscopic findings, and outcomes in patients with pouchitis with ileal mucosal adaptation are poorly understood.Methods: This was a single-center retrospective study comprising UC patients treated by proctocolectomy with ileal pouch-anal anastomosis who had undergone pouchoscopy at the University of Tsukuba Hospital between 2005 and 2022. Endoscopic phenotypes were evaluated according to the Chicago classification. High-iron diamine staining (HID) was performed to identify sulfomucin (colon-type mucin)-producing goblet cells (GCs) in pouch biopsies. We compared clinical data between patients with (high HID group) and without > 10% sulfomucin-producing GCs in at least one biopsy (low HID group).Results: We reviewed 390 endoscopic examination reports from 50 patients. Focal inflammation was the most common phenotype (78%). Five patients (10%) required diverting ileostomy. Diffuse inflammation and fistula were significant risk factors for diverting ileostomy. The median proportion of sulfomucin-producing GCs on histological analysis of 82 pouch biopsies from 23 patients was 9.9% (range, 0%–93%). The duration of disease was significantly greater in the high HID group compared to the low HID group. The median percentage of sulfomucin-producing GCs was significantly higher in patients with diffuse inflammation or fistula compared to other endoscopic phenotypes (14% vs. 6.0%, P= 0.011).Conclusions: Greater proportions of sulfomucin-producing GCs were observed in endoscopic phenotypes associated with poor outcomes in UC, indicating patients with pouchitis showing colonic metaplasia of GCs may benefit from early interventions.
- 31 January 2024
- Published by Korean Association for the Study of Intestinal Diseases in Intestinal Research
- Vol. 22 (1) , 92-103
Open AccessAssociation of colonic metaplasia of goblet cells and endoscopic phenotypes of the J pouch in patients with ulcerative colitis: a retrospective pilot study
Background/Aims: Mucosal adaptation of the ileum toward colonic epithelium has been reported in pouchitis in ulcerative colitis (UC); however, the clinical characteristics, endoscopic findings, and outcomes in patients with pouchitis with ileal mucosal adaptation are poorly understood.Methods: This was a single-center retrospective study comprising UC patients treated by proctocolectomy with ileal pouch-anal anastomosis who had undergone pouchoscopy at the University of Tsukuba Hospital between 2005 and 2022. Endoscopic phenotypes were evaluated according to the Chicago classification. High-iron diamine staining (HID) was performed to identify sulfomucin (colon-type mucin)-producing goblet cells (GCs) in pouch biopsies. We compared clinical data between patients with (high HID group) and without > 10% sulfomucin-producing GCs in at least one biopsy (low HID group).Results: We reviewed 390 endoscopic examination reports from 50 patients. Focal inflammation was the most common phenotype (78%). Five patients (10%) required diverting ileostomy. Diffuse inflammation and fistula were significant risk factors for diverting ileostomy. The median proportion of sulfomucin-producing GCs on histological analysis of 82 pouch biopsies from 23 patients was 9.9% (range, 0%–93%). The duration of disease was significantly greater in the high HID group compared to the low HID group. The median percentage of sulfomucin-producing GCs was significantly higher in patients with diffuse inflammation or fistula compared to other endoscopic phenotypes (14% vs. 6.0%, P= 0.011).Conclusions: Greater proportions of sulfomucin-producing GCs were observed in endoscopic phenotypes associated with poor outcomes in UC, indicating patients with pouchitis showing colonic metaplasia of GCs may benefit from early interventions.
- Open Access
- 1 January 2023
- Published by Association for Computational Linguistics (ACL)
- p. 4795-4809
Predicting Numerals in Text Using Nearest Neighbor Language Models
Taku Sakamoto, Akiko Aizawa. Findings of the Association for Computational Linguistics: ACL 2023. 2023.
- 1 January 2023
- Published by Association for Computational Linguistics (ACL)
- p. 4795-4809
Open AccessPredicting Numerals in Text Using Nearest Neighbor Language Models
Taku Sakamoto, Akiko Aizawa. Findings of the Association for Computational Linguistics: ACL 2023. 2023.
- Open Access
Unexpected adhesive bowel obstruction after endoscopic submucosal dissection of early sigmoid colon cancer
Various complications of colorectal endoscopic submucosal dissection (ESD) have been reported, including bleeding, penetration, perforation, and coagulation syndrome. However, the occurrence of bowel obstruction after ESD is rare. We report a case of adhesive bowel obstruction after ESD for a laterally spreading tumor in the sigmoid colon. The 35‐mm tumor was successfully removed by ESD without intraoperative complications. The patient had a fever, lower abdominal pain, and a small amount of bloody stool the day after ESD. Endoscopy revealed minor bleeding from the ESD scar, which was treated by hemostatic clips. Pathological analysis showed adenocarcinoma was exposed to the vertical margin; therefore, the resection was non‐curative. At 39 days after ESD and 36 days after discharge, the patient had abdominal pain and nausea. She was readmitted with a diagnosis of adhesive bowel obstruction. Conservative treatment was ineffective; therefore, she underwent sigmoidectomy combined with partial resection of the small intestine because of small intestinal stenosis caused by inflammation. The pathological examination showed localized peritonitis around the sigmoid colon where ESD was performed. There was more fibrosis along the serous surface of the small intestine than on the sigmoid colon. We concluded that there was a micro‐perforation that could not be detected by endoscopy or physical examination. This case indicates that adhesive bowel obstruction may occur as a complication of ESD.
Open AccessUnexpected adhesive bowel obstruction after endoscopic submucosal dissection of early sigmoid colon cancer
Various complications of colorectal endoscopic submucosal dissection (ESD) have been reported, including bleeding, penetration, perforation, and coagulation syndrome. However, the occurrence of bowel obstruction after ESD is rare. We report a case of adhesive bowel obstruction after ESD for a laterally spreading tumor in the sigmoid colon. The 35‐mm tumor was successfully removed by ESD without intraoperative complications. The patient had a fever, lower abdominal pain, and a small amount of bloody stool the day after ESD. Endoscopy revealed minor bleeding from the ESD scar, which was treated by hemostatic clips. Pathological analysis showed adenocarcinoma was exposed to the vertical margin; therefore, the resection was non‐curative. At 39 days after ESD and 36 days after discharge, the patient had abdominal pain and nausea. She was readmitted with a diagnosis of adhesive bowel obstruction. Conservative treatment was ineffective; therefore, she underwent sigmoidectomy combined with partial resection of the small intestine because of small intestinal stenosis caused by inflammation. The pathological examination showed localized peritonitis around the sigmoid colon where ESD was performed. There was more fibrosis along the serous surface of the small intestine than on the sigmoid colon. We concluded that there was a micro‐perforation that could not be detected by endoscopy or physical examination. This case indicates that adhesive bowel obstruction may occur as a complication of ESD.