Kunzan Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kunzan Liu has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Sixian You
Research Laboratory of Electronics, MIT, Cambridge, MA 02139, USA
7 shared publications - Li-Yu Yu
Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA, USA
4 shared publications - Linglong Dai
Department of Electronic Engineering and the State Key Laboratory of Space Network and Communications, Tsinghua University, Beijing, China
4 shared publications Honghao Cao
3 shared publications- Honghao Cao
Research Laboratory of Electronics, MIT, Cambridge, MA 02139, USA
3 shared publications Jiashu Han
3 shared publications
Latest Publications
- 27 April 2026
- Published by Springer Nature in Nature Methods
- Vol. 23 (5) , 1024-1036
Self-localized ultrafast pencil beam for volumetric multiphoton imaging
The formation of organized optical states in multidimensional systems is crucial for understanding light-matter interaction and advancing light-shaping technologies. Here we report the observation of a self-localized, ultrafast pencil beam near the critical power in a standard multimode fiber. We demonstrate that self-focusing, traditionally considered detrimental, facilitates a nonlinear spatiotemporal localized state with a sidelobe-suppressed Bessel-like profile and markedly improved stability. Generated simply by an on-axis Gaussian launch, this beam is readily integrated into standard multiphoton microscopes. We applied this self-localized beam to two-photon imaging of mouse enteric nervous systems, where it outperformed conventional Bessel beams through reduced sidelobes and enhanced aberration resilience. Lastly, we monitored transferrin uptake dynamics in a live human blood-brain barrier model using minute-resolved three-dimensional scans, revealing spatiotemporal heterogeneity across different cell types. Our findings offer a robust approach for generating ultrafast pencil beams, enabling high-throughput three-dimensional biosystem imaging to elucidate biological transport pathways.
- 27 April 2026
- Published by Springer Nature in Nature Methods
- Vol. 23 (5) , 1024-1036
Self-localized ultrafast pencil beam for volumetric multiphoton imaging
The formation of organized optical states in multidimensional systems is crucial for understanding light-matter interaction and advancing light-shaping technologies. Here we report the observation of a self-localized, ultrafast pencil beam near the critical power in a standard multimode fiber. We demonstrate that self-focusing, traditionally considered detrimental, facilitates a nonlinear spatiotemporal localized state with a sidelobe-suppressed Bessel-like profile and markedly improved stability. Generated simply by an on-axis Gaussian launch, this beam is readily integrated into standard multiphoton microscopes. We applied this self-localized beam to two-photon imaging of mouse enteric nervous systems, where it outperformed conventional Bessel beams through reduced sidelobes and enhanced aberration resilience. Lastly, we monitored transferrin uptake dynamics in a live human blood-brain barrier model using minute-resolved three-dimensional scans, revealing spatiotemporal heterogeneity across different cell types. Our findings offer a robust approach for generating ultrafast pencil beams, enabling high-throughput three-dimensional biosystem imaging to elucidate biological transport pathways.
- Open Access
Simultaneous Label-free Imaging of Nucleolar Dynamics and Subcellular Metabolic Shifts Across Tissue Contexts
The nucleolus is essential for ribosome biogenesis and for regulating cellular responses to growth and stress, and its relationship to cellular metabolic activity and functional state highlights its potential as a biomarker of cellular health. However, challenges in contrast multiplexing and high-resolution isotropic three-dimensional (3D) imaging hinder the non-invasive, simultaneous assessment of nucleolar activity and subcellular metabolic maps across different tissue contexts, especially in complex 3D environments. To fully harness the nucleolus’s potential as a biomarker and diagnostic target, we present a multimodal imaging platform that combines third harmonic generation (THG) imaging with metabolic autofluorescence of NAD(P)H and FAD to study structural and metabolic nucleolar dynamics. Enabled by a high-power multimode fiber source and an axial deblurring network, we achieved ∼ 400 nm isotropic resolution in deep 3D imaging and confirmed the high accuracy of our method for label-free nucleolus identification using co-registered immunostaining and electron microscopy. To establish the biological relevance of our approach, we demonstrate that nucleolar stress leads to an unexpected depletion of NADH across cellular compartments. Furthermore, in the human endometrium—where nucleolar dynamics are central to the tissue’s response to progesterone—our label-free imaging strategy delineated endometrial structures in freshly excised tissues and revealed that progesterone treatment induces distinct changes in nucleolar translocation and metabolic adaptation in organoids derived from diseased patients compared to controls. This capacity to non-invasively visualize and quantify features of the nucleolus and its local metabolic microenvironment at single-cell resolution in human tissues—and dynamically track these changes over time in patient-derived organoids—provides a powerful tool for uncovering the roles of the nucleolus in development, disease progression, and therapeutic response. Together, these findings establish our platform as a significant advance for both fundamental research and organelle-based tissue diagnostics.
Open AccessSimultaneous Label-free Imaging of Nucleolar Dynamics and Subcellular Metabolic Shifts Across Tissue Contexts
The nucleolus is essential for ribosome biogenesis and for regulating cellular responses to growth and stress, and its relationship to cellular metabolic activity and functional state highlights its potential as a biomarker of cellular health. However, challenges in contrast multiplexing and high-resolution isotropic three-dimensional (3D) imaging hinder the non-invasive, simultaneous assessment of nucleolar activity and subcellular metabolic maps across different tissue contexts, especially in complex 3D environments. To fully harness the nucleolus’s potential as a biomarker and diagnostic target, we present a multimodal imaging platform that combines third harmonic generation (THG) imaging with metabolic autofluorescence of NAD(P)H and FAD to study structural and metabolic nucleolar dynamics. Enabled by a high-power multimode fiber source and an axial deblurring network, we achieved ∼ 400 nm isotropic resolution in deep 3D imaging and confirmed the high accuracy of our method for label-free nucleolus identification using co-registered immunostaining and electron microscopy. To establish the biological relevance of our approach, we demonstrate that nucleolar stress leads to an unexpected depletion of NADH across cellular compartments. Furthermore, in the human endometrium—where nucleolar dynamics are central to the tissue’s response to progesterone—our label-free imaging strategy delineated endometrial structures in freshly excised tissues and revealed that progesterone treatment induces distinct changes in nucleolar translocation and metabolic adaptation in organoids derived from diseased patients compared to controls. This capacity to non-invasively visualize and quantify features of the nucleolus and its local metabolic microenvironment at single-cell resolution in human tissues—and dynamically track these changes over time in patient-derived organoids—provides a powerful tool for uncovering the roles of the nucleolus in development, disease progression, and therapeutic response. Together, these findings establish our platform as a significant advance for both fundamental research and organelle-based tissue diagnostics.
- 10 March 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (6) , 12269-12287
Learned, uncertainty-driven adaptive acquisition for photon-efficient scanning microscopy
Scanning microscopy systems, such as confocal and multiphoton microscopy, are powerful imaging tools for probing deep into biological tissue. However, scanning systems have an inherent trade-off between acquisition time, field of view, phototoxicity, and image quality. This often results in noisy measurements when fast, large field of view, and/or gentle imaging is needed. Deep learning could be used to denoise noisy microscopy measurements, but these algorithms can be prone to hallucination, which can be disastrous for medical and scientific applications. We propose a method to simultaneously denoise and predict pixel-wise uncertainty for scanning microscopy systems, improving algorithm trustworthiness and providing statistical guarantees for deep learning predictions. Furthermore, we propose to leverage this learned, pixel-wise uncertainty to drive an adaptive acquisition technique that rescans only the most uncertain regions of a sample, saving time and reducing the total light dose to the sample. We demonstrate our method on experimental confocal and multiphoton microscopy systems, showing that our uncertainty maps can pinpoint hallucinations in the deep learned predictions. Finally, with our adaptive acquisition technique, we demonstrate up to 16× reduction in acquisition time and total light dose while successfully recovering fine features in the sample and reducing hallucinations. We are the first to demonstrate distribution-free uncertainty quantification for a denoising task with real experimental data and the first to propose adaptive acquisition based on reconstruction uncertainty.
- 10 March 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (6) , 12269-12287
Learned, uncertainty-driven adaptive acquisition for photon-efficient scanning microscopy
Scanning microscopy systems, such as confocal and multiphoton microscopy, are powerful imaging tools for probing deep into biological tissue. However, scanning systems have an inherent trade-off between acquisition time, field of view, phototoxicity, and image quality. This often results in noisy measurements when fast, large field of view, and/or gentle imaging is needed. Deep learning could be used to denoise noisy microscopy measurements, but these algorithms can be prone to hallucination, which can be disastrous for medical and scientific applications. We propose a method to simultaneously denoise and predict pixel-wise uncertainty for scanning microscopy systems, improving algorithm trustworthiness and providing statistical guarantees for deep learning predictions. Furthermore, we propose to leverage this learned, pixel-wise uncertainty to drive an adaptive acquisition technique that rescans only the most uncertain regions of a sample, saving time and reducing the total light dose to the sample. We demonstrate our method on experimental confocal and multiphoton microscopy systems, showing that our uncertainty maps can pinpoint hallucinations in the deep learned predictions. Finally, with our adaptive acquisition technique, we demonstrate up to 16× reduction in acquisition time and total light dose while successfully recovering fine features in the sample and reducing hallucinations. We are the first to demonstrate distribution-free uncertainty quantification for a denoising task with real experimental data and the first to propose adaptive acquisition based on reconstruction uncertainty.
- Open Access
- 16 January 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-14
System- and sample-agnostic isotropic three-dimensional microscopy by weakly physics-informed, domain-shift-resistant axial deblurring
Three-dimensional subcellular imaging is essential for biomedical research, but the diffraction limit of optical microscopy compromises axial resolution, hindering accurate three-dimensional structural analysis. This challenge is particularly pronounced in label-free imaging of thick, heterogeneous tissues, where assumptions about data distribution (e.g. sparsity, label-specific distribution, and lateral-axial similarity) and system priors (e.g. independent and identically distributed noise and linear shift-invariant point-spread functions are often invalid. Here, we introduce SSAI-3D, a weakly physics-informed, domain-shift-resistant framework for robust isotropic three-dimensional imaging. SSAI-3D enables robust axial deblurring by generating a diverse, noise-resilient, sample-informed training dataset and sparsely fine-tuning a large pre-trained blind deblurring network. SSAI-3D is applied to label-free nonlinear imaging of living organoids, freshly excised human endometrium tissue, and mouse whisker pads, and further validated in publicly available ground-truth-paired experimental datasets of three-dimensional heterogeneous biological tissues with unknown blurring and noise across different microscopy systems.
- 16 January 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-14
Open AccessSystem- and sample-agnostic isotropic three-dimensional microscopy by weakly physics-informed, domain-shift-resistant axial deblurring
Three-dimensional subcellular imaging is essential for biomedical research, but the diffraction limit of optical microscopy compromises axial resolution, hindering accurate three-dimensional structural analysis. This challenge is particularly pronounced in label-free imaging of thick, heterogeneous tissues, where assumptions about data distribution (e.g. sparsity, label-specific distribution, and lateral-axial similarity) and system priors (e.g. independent and identically distributed noise and linear shift-invariant point-spread functions are often invalid. Here, we introduce SSAI-3D, a weakly physics-informed, domain-shift-resistant framework for robust isotropic three-dimensional imaging. SSAI-3D enables robust axial deblurring by generating a diverse, noise-resilient, sample-informed training dataset and sparsely fine-tuning a large pre-trained blind deblurring network. SSAI-3D is applied to label-free nonlinear imaging of living organoids, freshly excised human endometrium tissue, and mouse whisker pads, and further validated in publicly available ground-truth-paired experimental datasets of three-dimensional heterogeneous biological tissues with unknown blurring and noise across different microscopy systems.
- Open Access
- 13 December 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (50) , eadp2438
Deep and dynamic metabolic and structural imaging in living tissues
Label-free imaging through two-photon autofluorescence of NAD(P)H allows for nondestructive, high-resolution visualization of cellular activities in living systems. However, its application to thick tissues has been restricted by its limited penetration depth within 300 μm, largely due to light scattering. Here, we demonstrate that the imaging depth for NAD(P)H can be extended to more than 700 μm in living engineered human multicellular microtissues by adopting multimode fiber-based, low repetition rate, high peak power, three-photon excitation of NAD(P)H at 1100 nm. This is achieved by having more than 0.5 megawatts peak power at the band of 1100 ± 25 nm through adaptively modulating multimodal nonlinear pulse propagation with a compact fiber shaper. Moreover, the eightfold increase in pulse energy enables faster imaging of monocyte behaviors in the living multicellular models. These results represent a substantial advance for deep and dynamic imaging of intact living biosystems. The modular design is anticipated to allow wide adoption for demanding imaging applications, including cancer research, immune responses, and tissue engineering.
- 13 December 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (50) , eadp2438
Open AccessDeep and dynamic metabolic and structural imaging in living tissues
Label-free imaging through two-photon autofluorescence of NAD(P)H allows for nondestructive, high-resolution visualization of cellular activities in living systems. However, its application to thick tissues has been restricted by its limited penetration depth within 300 μm, largely due to light scattering. Here, we demonstrate that the imaging depth for NAD(P)H can be extended to more than 700 μm in living engineered human multicellular microtissues by adopting multimode fiber-based, low repetition rate, high peak power, three-photon excitation of NAD(P)H at 1100 nm. This is achieved by having more than 0.5 megawatts peak power at the band of 1100 ± 25 nm through adaptively modulating multimodal nonlinear pulse propagation with a compact fiber shaper. Moreover, the eightfold increase in pulse energy enables faster imaging of monocyte behaviors in the living multicellular models. These results represent a substantial advance for deep and dynamic imaging of intact living biosystems. The modular design is anticipated to allow wide adoption for demanding imaging applications, including cancer research, immune responses, and tissue engineering.
- Open Access
- 6 March 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-12
Spectral-temporal-spatial customization via modulating multimodal nonlinear pulse propagation
Multimode fibers (MMFs) are gaining renewed interest for nonlinear effects due to their high-dimensional spatiotemporal nonlinear dynamics and scalability for high power. High-brightness MMF sources with effective control of the nonlinear processes would offer possibilities in many areas from high-power fiber lasers, to bioimaging and chemical sensing, and to intriguing physics phenomena. Here we present a simple yet effective way of controlling nonlinear effects at high peak power levels. This is achieved by leveraging not only the spatial but also the temporal degrees of freedom during multimodal nonlinear pulse propagation in step-index MMFs, using a programmable fiber shaper that introduces time-dependent disorders. We achieve high tunability in MMF output fields, resulting in a broadband high-peak-power source. Its potential as a nonlinear imaging source is further demonstrated through widely tunable two-photon and three-photon microscopy. These demonstrations provide possibilities for technology advances in nonlinear optics, bioimaging, spectroscopy, optical computing, and material processing.
- 6 March 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-12
Open AccessSpectral-temporal-spatial customization via modulating multimodal nonlinear pulse propagation
Multimode fibers (MMFs) are gaining renewed interest for nonlinear effects due to their high-dimensional spatiotemporal nonlinear dynamics and scalability for high power. High-brightness MMF sources with effective control of the nonlinear processes would offer possibilities in many areas from high-power fiber lasers, to bioimaging and chemical sensing, and to intriguing physics phenomena. Here we present a simple yet effective way of controlling nonlinear effects at high peak power levels. This is achieved by leveraging not only the spatial but also the temporal degrees of freedom during multimodal nonlinear pulse propagation in step-index MMFs, using a programmable fiber shaper that introduces time-dependent disorders. We achieve high tunability in MMF output fields, resulting in a broadband high-peak-power source. Its potential as a nonlinear imaging source is further demonstrated through widely tunable two-photon and three-photon microscopy. These demonstrations provide possibilities for technology advances in nonlinear optics, bioimaging, spectroscopy, optical computing, and material processing.
- 10 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Information Theory
- Vol. 69 (6) , 3795-3813
Sensing RISs: Enabling Dimension-Independent CSI Acquisition for Beamforming
Reconfigurable intelligent surfaces (RISs) are envisioned as a potentially transformative technology for future wireless communications. However, RISs’ inability to process signals and the attendant increased channel dimension have brought new challenges to RIS-assisted systems, including significantly increased pilot overhead required for channel estimation. To address these problems, several prior contributions that enhance the hardware architecture of RISs or develop algorithms to exploit the channels’ mathematical properties have been made, where the required pilot overhead is reduced to be proportional to the number of RIS elements. In this paper, we propose a dimension-independent channel state information (CSI) acquisition approach in which the required pilot overhead is independent of the number of RIS elements. Specifically, in contrast to traditional signal transmission methods, where signals from the base station (BS) and the users are transmitted in different time slots, we propose a novel method in which signals are transmitted from the BS and the user simultaneously during CSI acquisition. With this method, an electromagnetic interference random field (IRF) will be induced on the RIS, and we propose the structure of sensing RIS to capture its features. Moreover, we develop three algorithms for parameter estimation in this system, in which one of the proposed vM-EM algorithm is analyzed with the fixed-point perturbation method to obtain an asymptotic achievable bound. In addition, we also derive the Cramér-Rao lower bound (CRLB) and an asymptotic expression for characterizing the best possible performance of the proposed algorithms. Simulation results verify that our proposed signal transmission method and the corresponding algorithms can achieve dimension-independent CSI acquisition for beamforming.
- 10 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Information Theory
- Vol. 69 (6) , 3795-3813
Sensing RISs: Enabling Dimension-Independent CSI Acquisition for Beamforming
Reconfigurable intelligent surfaces (RISs) are envisioned as a potentially transformative technology for future wireless communications. However, RISs’ inability to process signals and the attendant increased channel dimension have brought new challenges to RIS-assisted systems, including significantly increased pilot overhead required for channel estimation. To address these problems, several prior contributions that enhance the hardware architecture of RISs or develop algorithms to exploit the channels’ mathematical properties have been made, where the required pilot overhead is reduced to be proportional to the number of RIS elements. In this paper, we propose a dimension-independent channel state information (CSI) acquisition approach in which the required pilot overhead is independent of the number of RIS elements. Specifically, in contrast to traditional signal transmission methods, where signals from the base station (BS) and the users are transmitted in different time slots, we propose a novel method in which signals are transmitted from the BS and the user simultaneously during CSI acquisition. With this method, an electromagnetic interference random field (IRF) will be induced on the RIS, and we propose the structure of sensing RIS to capture its features. Moreover, we develop three algorithms for parameter estimation in this system, in which one of the proposed vM-EM algorithm is analyzed with the fixed-point perturbation method to obtain an asymptotic achievable bound. In addition, we also derive the Cramér-Rao lower bound (CRLB) and an asymptotic expression for characterizing the best possible performance of the proposed algorithms. Simulation results verify that our proposed signal transmission method and the corresponding algorithms can achieve dimension-independent CSI acquisition for beamforming.
- Open Access
Sensing RISs: Enabling Dimension-Independent CSI Acquisition for Beamforming
Reconfigurable intelligent surfaces (RISs) are envisioned as a potentially transformative technology for future wireless communications. However, RISs' inability to process signals and the attendant increased channel dimension have brought new challenges to RIS-assisted systems, including significantly increased pilot overhead required for channel estimation. To address these problems, several prior contributions that enhance the hardware architecture of RISs or develop algorithms to exploit the channels' mathematical properties have been made, where the required pilot overhead is reduced to be proportional to the number of RIS elements. In this paper, we propose a dimension-independent channel state information (CSI) acquisition approach in which the required pilot overhead is independent of the number of RIS elements. Specifically, in contrast to traditional signal transmission methods, where signals from the base station (BS) and the users are transmitted in different time slots, we propose a novel method in which signals are transmitted from the BS and the user simultaneously during CSI acquisition. With this method, an electromagnetic interference random field (IRF) will be induced on the RIS, and we propose the structure of sensing RIS to capture its features. Moreover, we develop three algorithms for parameter estimation in this system, in which one of the proposed vM-EM algorithm is analyzed with the fixed-point perturbation method to obtain an asymptotic achievable bound. In addition, we also derive the Cram\'er-Rao lower bound (CRLB) and an asymptotic expression for characterizing the best possible performance of the proposed algorithms. Simulation results verify that our proposed signal transmission method and the corresponding algorithms can achieve dimension-independent CSI acquisition for beamforming.
Open AccessSensing RISs: Enabling Dimension-Independent CSI Acquisition for Beamforming
Reconfigurable intelligent surfaces (RISs) are envisioned as a potentially transformative technology for future wireless communications. However, RISs' inability to process signals and the attendant increased channel dimension have brought new challenges to RIS-assisted systems, including significantly increased pilot overhead required for channel estimation. To address these problems, several prior contributions that enhance the hardware architecture of RISs or develop algorithms to exploit the channels' mathematical properties have been made, where the required pilot overhead is reduced to be proportional to the number of RIS elements. In this paper, we propose a dimension-independent channel state information (CSI) acquisition approach in which the required pilot overhead is independent of the number of RIS elements. Specifically, in contrast to traditional signal transmission methods, where signals from the base station (BS) and the users are transmitted in different time slots, we propose a novel method in which signals are transmitted from the BS and the user simultaneously during CSI acquisition. With this method, an electromagnetic interference random field (IRF) will be induced on the RIS, and we propose the structure of sensing RIS to capture its features. Moreover, we develop three algorithms for parameter estimation in this system, in which one of the proposed vM-EM algorithm is analyzed with the fixed-point perturbation method to obtain an asymptotic achievable bound. In addition, we also derive the Cram\'er-Rao lower bound (CRLB) and an asymptotic expression for characterizing the best possible performance of the proposed algorithms. Simulation results verify that our proposed signal transmission method and the corresponding algorithms can achieve dimension-independent CSI acquisition for beamforming.
- 1 January 2023
- Published by Optica Publishing Group
- Vol. 100, ITu5E.4
Adaptive Fiber Source for High-Speed Label-Free Multimodal Multiphoton Microscopy
We propose a label-free multimodal multiphoton microscopy platform using a multimode fiber (MMF) source with adaptive optimization using a fiber shaper. Imaging results have shown the effectiveness of optimizing the MMF source and the potential of this platform as a versatile tool for bioimaging.
- 1 January 2023
- Published by Optica Publishing Group
- Vol. 100, ITu5E.4
Adaptive Fiber Source for High-Speed Label-Free Multimodal Multiphoton Microscopy
We propose a label-free multimodal multiphoton microscopy platform using a multimode fiber (MMF) source with adaptive optimization using a fiber shaper. Imaging results have shown the effectiveness of optimizing the MMF source and the potential of this platform as a versatile tool for bioimaging.