Iván Domingo Muñoz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Iván Domingo Muñoz has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Oliver Jäkel
German Cancer Research Center
9 shared publications - Jeppe Brage Christensen
Paul Scherrer Institute (PSI)
8 shared publications - Eduardo Gardenali Yukihara
Paul Scherrer Institute (PSI)
7 shared publications - José Vedelago
Department of Radiation Oncology, University Hospital Heidelberg, Im Neuenheimer Feld 672, Heidelberg, BW, 69120, GERMANY
6 shared publications - Christina Stengl
Division of Medical Physics in Radiation Oncology, German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg, Heidelberg, BW, 69120, GERMANY
5 shared publications Armin Runz
Division of Medical Physics in Radiation Oncology German Cancer Research Center (DKFZ) Heidelberg Germany
3 shared publications
Latest Publications
- 5 June 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (14) , 145006
Water calorimetry-based beam quality correction factors for carbon and helium ion beams
Objective. To determine beam quality correction factors, kQ, in single-layer scanned carbon and helium ion beams using water calorimetry, thereby reducing uncertainties in dosimetry for light ion therapy. Approach. Water calorimetry measurements were performed under harmonized conditions at two synchrotron-based ion beam therapy centers (MedAustron, Austria and HIT, Germany). Measurements were conducted in the plateau region of single-layer scanned beams. Carbon ion beams covered nominal energies from 213.4 to 402.8 MeV/u, while helium ion beams were measured at 196.3 and 198.8 MeV/u. Multiple cylindrical (IBA FC65-G, PTW 30013) and plane-parallel (IBA PPC05, PPC40; PTW 34001, 34045) ionization chamber types were investigated. Results. kQ-factors were determined with standard uncertainties of approximately 1%, depending on chamber type and measurement condition. For all investigated chambers, inter-center agreement was observed within the combined standard uncertainties. Chamber-to-chamber variability was below 0.5% for chamber types for which two samples were available, except for the IBA PPC05, for which differences up to 1% were observed. For carbon ion beams, the measured kQ-factors are consistent with previously published water calorimetry-based results. However, systematic deviations up to 3% persist between experimentally determined and Monte Carlo-derived kQ values. The measured kQ-factors for helium ions show trends that are broadly similar to those observed in carbon ion beams across all chamber types. Significance. This work expands the experimental kQ-database for light ions by providing new carbon ion data and the first experimental kQ-factors for helium ion beams. These results provide essential experimental data for future refinement of dosimetry recommendations, and highlight persistent discrepancies between the experimental and Monte Carlo-based kQ-factors that require further investigation.
- 5 June 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (14) , 145006
Water calorimetry-based beam quality correction factors for carbon and helium ion beams
Objective. To determine beam quality correction factors, kQ, in single-layer scanned carbon and helium ion beams using water calorimetry, thereby reducing uncertainties in dosimetry for light ion therapy. Approach. Water calorimetry measurements were performed under harmonized conditions at two synchrotron-based ion beam therapy centers (MedAustron, Austria and HIT, Germany). Measurements were conducted in the plateau region of single-layer scanned beams. Carbon ion beams covered nominal energies from 213.4 to 402.8 MeV/u, while helium ion beams were measured at 196.3 and 198.8 MeV/u. Multiple cylindrical (IBA FC65-G, PTW 30013) and plane-parallel (IBA PPC05, PPC40; PTW 34001, 34045) ionization chamber types were investigated. Results. kQ-factors were determined with standard uncertainties of approximately 1%, depending on chamber type and measurement condition. For all investigated chambers, inter-center agreement was observed within the combined standard uncertainties. Chamber-to-chamber variability was below 0.5% for chamber types for which two samples were available, except for the IBA PPC05, for which differences up to 1% were observed. For carbon ion beams, the measured kQ-factors are consistent with previously published water calorimetry-based results. However, systematic deviations up to 3% persist between experimentally determined and Monte Carlo-derived kQ values. The measured kQ-factors for helium ions show trends that are broadly similar to those observed in carbon ion beams across all chamber types. Significance. This work expands the experimental kQ-database for light ions by providing new carbon ion data and the first experimental kQ-factors for helium ion beams. These results provide essential experimental data for future refinement of dosimetry recommendations, and highlight persistent discrepancies between the experimental and Monte Carlo-based kQ-factors that require further investigation.
- Open Access
- 24 January 2026
- Published by Elsevier in Radiation Measurements
- Vol. 192
Characterization of lithium fluoride fluorescent nuclear track detectors for linear energy transfer measurements in light-ion beams using confocal microscopy
- 24 January 2026
- Published by Elsevier in Radiation Measurements
- Vol. 192
Open AccessCharacterization of lithium fluoride fluorescent nuclear track detectors for linear energy transfer measurements in light-ion beams using confocal microscopy
- Open Access
- 24 October 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (21) , 215008
Achieving high-resolution spatial mapping of dose and linear energy transfer in ion-beam therapy
Objective. We present a novel detector system capable of simultaneously obtaining two-dimensional (2D) dose and linear energy transfer (LET) maps from Al 2 O 3 films of sizes up to ( 190 × 190 ) mm 2 using optically stimulated luminescence (OSL). Approach. The system is based on the OSL from doped Al 2 O 3 films measured using pulsed stimulation and time-resolved OSL detection. The system was calibrated in 1 H-, 4 He-, and 12 C-ion beams. The minimal detectable dose (MDD), response homogeneity, pixel cross-stimulation, and precision were also investigated. To demonstrate the system’s performance, 2D maps of dose and LET of a proton Bragg curve were measured. Main results. The system was demonstrated to be capable of obtaining absorbed dose and LET 2D maps with a spatial resolution set to ( 1.0 × 1.0 ) mm 2 . The system was calibrated over a clinically relevant range of LET values and characterized through assessment of MDD ( < 25 mGy), readout protocols, response homogeneity, precision, and relative detector efficiency. Dose and LET were found to be measurable with precisions of 3.2% and 10%, respectively. Significance. To our knowledge, this is the first passive detector system capable of measuring LET and dose simultaneously in 2D with a 1.0 mm 2 spatial resolution requiring no prior information. Such properties are required to experimentally validate simulated dose and LET distributions in ion-beam therapy, paving the way for sub-mm mapping of radiation-induced relative biological effectiveness.
- 24 October 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (21) , 215008
Open AccessAchieving high-resolution spatial mapping of dose and linear energy transfer in ion-beam therapy
Objective. We present a novel detector system capable of simultaneously obtaining two-dimensional (2D) dose and linear energy transfer (LET) maps from Al 2 O 3 films of sizes up to ( 190 × 190 ) mm 2 using optically stimulated luminescence (OSL). Approach. The system is based on the OSL from doped Al 2 O 3 films measured using pulsed stimulation and time-resolved OSL detection. The system was calibrated in 1 H-, 4 He-, and 12 C-ion beams. The minimal detectable dose (MDD), response homogeneity, pixel cross-stimulation, and precision were also investigated. To demonstrate the system’s performance, 2D maps of dose and LET of a proton Bragg curve were measured. Main results. The system was demonstrated to be capable of obtaining absorbed dose and LET 2D maps with a spatial resolution set to ( 1.0 × 1.0 ) mm 2 . The system was calibrated over a clinically relevant range of LET values and characterized through assessment of MDD ( < 25 mGy), readout protocols, response homogeneity, precision, and relative detector efficiency. Dose and LET were found to be measurable with precisions of 3.2% and 10%, respectively. Significance. To our knowledge, this is the first passive detector system capable of measuring LET and dose simultaneously in 2D with a 1.0 mm 2 spatial resolution requiring no prior information. Such properties are required to experimentally validate simulated dose and LET distributions in ion-beam therapy, paving the way for sub-mm mapping of radiation-induced relative biological effectiveness.
- Open Access
- 8 May 2025
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 34, 100775
Dose assessment in moving targets and organs at risk during carbon ion therapy for pancreatic cancer with respiratory gating
- 8 May 2025
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 34, 100775
Open AccessDose assessment in moving targets and organs at risk during carbon ion therapy for pancreatic cancer with respiratory gating
- Open Access
- 13 August 2024
- Published by Elsevier in Radiation Measurements
- Vol. 177
Optically stimulated luminescence detectors for LET determination and dosimetry in ion beam therapy
- 13 August 2024
- Published by Elsevier in Radiation Measurements
- Vol. 177
Open AccessOptically stimulated luminescence detectors for LET determination and dosimetry in ion beam therapy
- Open Access
- 21 June 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (13) , 135004
Assessment of fluence- and dose-averaged linear energy transfer with passive luminescence detectors in clinical proton beams
Objective. This work investigates the use of passive luminescence detectors to determine different types of averaged linear energy transfer ( LET ― ) for the energies relevant to proton therapy. The experimental results are compared to reference values obtained from Monte Carlo simulations. Approach. Optically stimulated luminescence detectors (OSLDs), fluorescent nuclear track detectors (FNTDs), and two different groups of thermoluminescence detectors (TLDs) were irradiated at four different radiation qualities. For each irradiation, the fluence- ( LET ― f ) and dose-averaged LET ( LET ― d ) were determined. For both quantities, two sub-types of averages were calculated, either considering the contributions from primary and secondary protons or from all protons and heavier, charged particles. Both simulated and experimental data were used in combination with a phenomenological model to estimate the relative biological effectiveness (RBE). Main results. All types of LET ― could be assessed with the luminescence detectors. The experimental determination of LET ― f is in agreement with reference data obtained from simulations across all measurement techniques and types of averaging. On the other hand, LET ― d can present challenges as a radiation quality metric to describe the detector response in mixed particle fields. However, excluding secondaries heavier than protons from the LET ― d calculation, as their contribution to the luminescence is suppressed by ionization quenching, leads to equal accuracy between LET ― f and LET ― d . Assessment of RBE through the experimentally determined LET ― d values agrees with independently acquired reference values, indicating that the investigated detectors can determine LET ― with sufficient accuracy for proton therapy. Significance. OSLDs, TLDs, and FNTDs can be used to determine LET ― and RBE in proton therapy. With the capability to determine dose through ionization quenching corrections derived from LET ― , OSLDs and TLDs can simultaneously ascertain dose, LET ― , and RBE. This makes passive detectors appealing for measurements in phantoms to facilitate validation of clinical treatment plans or experiments related to proton therapy.
- 21 June 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (13) , 135004
Open AccessAssessment of fluence- and dose-averaged linear energy transfer with passive luminescence detectors in clinical proton beams
Objective. This work investigates the use of passive luminescence detectors to determine different types of averaged linear energy transfer ( LET ― ) for the energies relevant to proton therapy. The experimental results are compared to reference values obtained from Monte Carlo simulations. Approach. Optically stimulated luminescence detectors (OSLDs), fluorescent nuclear track detectors (FNTDs), and two different groups of thermoluminescence detectors (TLDs) were irradiated at four different radiation qualities. For each irradiation, the fluence- ( LET ― f ) and dose-averaged LET ( LET ― d ) were determined. For both quantities, two sub-types of averages were calculated, either considering the contributions from primary and secondary protons or from all protons and heavier, charged particles. Both simulated and experimental data were used in combination with a phenomenological model to estimate the relative biological effectiveness (RBE). Main results. All types of LET ― could be assessed with the luminescence detectors. The experimental determination of LET ― f is in agreement with reference data obtained from simulations across all measurement techniques and types of averaging. On the other hand, LET ― d can present challenges as a radiation quality metric to describe the detector response in mixed particle fields. However, excluding secondaries heavier than protons from the LET ― d calculation, as their contribution to the luminescence is suppressed by ionization quenching, leads to equal accuracy between LET ― f and LET ― d . Assessment of RBE through the experimentally determined LET ― d values agrees with independently acquired reference values, indicating that the investigated detectors can determine LET ― with sufficient accuracy for proton therapy. Significance. OSLDs, TLDs, and FNTDs can be used to determine LET ― and RBE in proton therapy. With the capability to determine dose through ionization quenching corrections derived from LET ― , OSLDs and TLDs can simultaneously ascertain dose, LET ― , and RBE. This makes passive detectors appealing for measurements in phantoms to facilitate validation of clinical treatment plans or experiments related to proton therapy.
- Open Access
- 17 April 2024
- Published by Wiley in Medical Physics
- Vol. 51 (8) , 5618-5631
Dosimetric study for breathing‐induced motion effects in an abdominal pancreas phantom for carbon ion mini‐beam radiotherapy
Background: Particle mini‐beam therapy exhibits promise in sparing healthy tissue through spatial fractionation, particularly notable for heavy ions, further enhancing the already favorable differential biological effectiveness at both target and entrance regions. However, breathing‐induced organ motion affects particle mini‐beam irradiation schemes since the organ displacements exceed the mini‐beam structure dimensions, decreasing the advantages of spatial fractionation.Purpose: In this study, the impact of breathing‐induced organ motion on the dose distribution was examined at the target and organs at risk(OARs) during carbon ion mini‐beam irradiation for pancreatic cancer.Methods: As a first step, the carbon ion mini‐beam pattern was characterized with Monte Carlo simulations. To analyze the impact of breathing‐induced organ motion on the dose distribution of a virtual pancreas tumor as target and related OARs, the anthropomorphic Pancreas Phantom for Ion beam Therapy (PPIeT) was irradiated with carbon ions. A mini‐beam collimator was used to deliver a spatially fractionated dose distribution. During irradiation, varying breathing motion amplitudes were induced, ranging from 5 to 15 mm. Post‐irradiation, the 2D dose pattern was analyzed, focusing on the full width at half maximum (FWHM), center‐to‐center distance (ctc), and the peak‐to‐valley dose ratio (PVDR).Results: The mini‐beam pattern was visible within OARs, while in the virtual pancreas tumor a more homogeneous dose distribution was achieved. Applied motion affected the mini‐beam pattern within the kidney, one of the OARs, reducing the PVDR from 3.78 0.12 to 1.478 0.070 for the 15 mm motion amplitude. In the immobile OARs including the spine and the skin at the back, the PVDR did not change within 3.4% comparing reference and motion conditions.Conclusions: This study provides an initial understanding of how breathing‐induced organ motion affects spatial fractionation during carbon ion irradiation, using an anthropomorphic phantom. A decrease in the PVDR was observed in the right kidney when breathing‐induced motion was applied, potentially increasing the risk of damage to OARs. Therefore, further studies are needed to explore the clinical viability of mini‐beam radiotherapy with carbon ions when irradiating abdominal regions.
- 17 April 2024
- Published by Wiley in Medical Physics
- Vol. 51 (8) , 5618-5631
Open AccessDosimetric study for breathing‐induced motion effects in an abdominal pancreas phantom for carbon ion mini‐beam radiotherapy
Background: Particle mini‐beam therapy exhibits promise in sparing healthy tissue through spatial fractionation, particularly notable for heavy ions, further enhancing the already favorable differential biological effectiveness at both target and entrance regions. However, breathing‐induced organ motion affects particle mini‐beam irradiation schemes since the organ displacements exceed the mini‐beam structure dimensions, decreasing the advantages of spatial fractionation.Purpose: In this study, the impact of breathing‐induced organ motion on the dose distribution was examined at the target and organs at risk(OARs) during carbon ion mini‐beam irradiation for pancreatic cancer.Methods: As a first step, the carbon ion mini‐beam pattern was characterized with Monte Carlo simulations. To analyze the impact of breathing‐induced organ motion on the dose distribution of a virtual pancreas tumor as target and related OARs, the anthropomorphic Pancreas Phantom for Ion beam Therapy (PPIeT) was irradiated with carbon ions. A mini‐beam collimator was used to deliver a spatially fractionated dose distribution. During irradiation, varying breathing motion amplitudes were induced, ranging from 5 to 15 mm. Post‐irradiation, the 2D dose pattern was analyzed, focusing on the full width at half maximum (FWHM), center‐to‐center distance (ctc), and the peak‐to‐valley dose ratio (PVDR).Results: The mini‐beam pattern was visible within OARs, while in the virtual pancreas tumor a more homogeneous dose distribution was achieved. Applied motion affected the mini‐beam pattern within the kidney, one of the OARs, reducing the PVDR from 3.78 0.12 to 1.478 0.070 for the 15 mm motion amplitude. In the immobile OARs including the spine and the skin at the back, the PVDR did not change within 3.4% comparing reference and motion conditions.Conclusions: This study provides an initial understanding of how breathing‐induced organ motion affects spatial fractionation during carbon ion irradiation, using an anthropomorphic phantom. A decrease in the PVDR was observed in the right kidney when breathing‐induced motion was applied, potentially increasing the risk of damage to OARs. Therefore, further studies are needed to explore the clinical viability of mini‐beam radiotherapy with carbon ions when irradiating abdominal regions.
- Open Access
- 2 March 2024
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 120 (1) , 205-215
Linear Energy Transfer Measurements and Estimation of Relative Biological Effectiveness in Proton and Helium Ion Beams Using Fluorescent Nuclear Track Detectors
- 2 March 2024
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 120 (1) , 205-215
Open AccessLinear Energy Transfer Measurements and Estimation of Relative Biological Effectiveness in Proton and Helium Ion Beams Using Fluorescent Nuclear Track Detectors
- 2 January 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (1) , 015027
A Monte Carlo study on the secondary neutron generation by oxygen ion beams for radiotherapy and its comparison to lighter ions
Objective. To study the secondary neutrons generated by primary oxygen beams for cancer treatment and compare the results to those from primary protons, helium, and carbon ions. This information can provide useful insight into the positioning of neutron detectors in phantom for future experimental dose assessments. Approach. Mono-energetic oxygen beams and spread-out Bragg peaks were simulated using the Monte Carlo particle transport codes FLUktuierende KAskade, tool for particle simulation, and Monte Carlo N-Particle, with energies within the therapeutic range. The energy and angular distribution of the secondary neutrons were quantified. Main results. The secondary neutron spectra generated by primary oxygen beams present the same qualitative trend as for other primary ions. The energy distributions resemble continuous spectra with one peak in the thermal/epithermal region, and one other peak in the fast/relativistic region, with the most probable energy ranging from 94 up to 277 MeV and maximum energies exceeding 500 MeV. The angular distribution of the secondary neutrons is mainly downstream-directed for the fast/relativistic energies, whereas the thermal/epithermal neutrons present a more isotropic propagation. When comparing the four different primary ions, there is a significant increase in the most probable energy as well as the number of secondary neutrons per primary particle when increasing the mass of the primaries. Significance. Most previous studies have only presented results of secondary neutrons generated by primary proton beams. In this work, secondary neutrons generated by primary oxygen beams are presented, and the obtained energy and angular spectra are added as supplementary material. Furthermore, a comparison of the secondary neutron generation by the different primary ions is given, which can be used as the starting point for future studies on treatment plan comparison and secondary neutron dose optimisation. The distal penumbra after the maximum dose deposition appears to be a suitable location for in-phantom dose assessments.
- 2 January 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (1) , 015027
A Monte Carlo study on the secondary neutron generation by oxygen ion beams for radiotherapy and its comparison to lighter ions
Objective. To study the secondary neutrons generated by primary oxygen beams for cancer treatment and compare the results to those from primary protons, helium, and carbon ions. This information can provide useful insight into the positioning of neutron detectors in phantom for future experimental dose assessments. Approach. Mono-energetic oxygen beams and spread-out Bragg peaks were simulated using the Monte Carlo particle transport codes FLUktuierende KAskade, tool for particle simulation, and Monte Carlo N-Particle, with energies within the therapeutic range. The energy and angular distribution of the secondary neutrons were quantified. Main results. The secondary neutron spectra generated by primary oxygen beams present the same qualitative trend as for other primary ions. The energy distributions resemble continuous spectra with one peak in the thermal/epithermal region, and one other peak in the fast/relativistic region, with the most probable energy ranging from 94 up to 277 MeV and maximum energies exceeding 500 MeV. The angular distribution of the secondary neutrons is mainly downstream-directed for the fast/relativistic energies, whereas the thermal/epithermal neutrons present a more isotropic propagation. When comparing the four different primary ions, there is a significant increase in the most probable energy as well as the number of secondary neutrons per primary particle when increasing the mass of the primaries. Significance. Most previous studies have only presented results of secondary neutrons generated by primary proton beams. In this work, secondary neutrons generated by primary oxygen beams are presented, and the obtained energy and angular spectra are added as supplementary material. Furthermore, a comparison of the secondary neutron generation by the different primary ions is given, which can be used as the starting point for future studies on treatment plan comparison and secondary neutron dose optimisation. The distal penumbra after the maximum dose deposition appears to be a suitable location for in-phantom dose assessments.
- Open Access
- 11 December 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (24) , 245013
A phantom to simulate organ motion and its effect on dose distribution in carbon ion therapy for pancreatic cancer
Objective . Carbon ion radiotherapy is a promising radiation technique for malignancies like pancreatic cancer. However, organs’ motion imposes challenges for achieving homogeneous dose delivery. In this study, an anthropomorphic P ancreas P hantom for I on-b e am T herapy (PPIeT) was developed to simulate breathing and gastrointestinal motion during radiotherapy. Approach . The developed phantom contains a pancreas, two kidneys, a duodenum, a spine and a spinal cord. The shell of the organs was 3D printed and filled with agarose-based mixtures. Hounsfield Units (HU) of PPIeTs’ organs were measured by CT. The pancreas motion amplitude in cranial-caudal (CC) direction was evaluated from patients’ 4D CT data. Motions within the obtained range were simulated and analyzed in PPIeT using MRI. Additionally, GI motion was mimicked by changing the volume of the duodenum and quantified by MRI. A patient-like treatment plan was calculated for carbon ions, and the phantom was irradiated in a static and moving condition. Dose measurements in the organs were performed using an ionization chamber and dosimetric films. Main results . PPIeT presented tissue equivalent HU and reproducible breathing-induced CC displacements of the pancreas between (3.98 ± 0.36) mm and a maximum of (18.19 ± 0.44) mm. The observed maximum change in distance of (14.28 ± 0.12) mm between pancreas and duodenum was consistent with findings in patients. Carbon ion irradiation revealed homogenous coverage of the virtual tumor at the pancreas in static condition with a 1% deviation from the treatment plan. Instead, the dose delivery during motion with the maximum amplitude yielded an underdosage of 21% at the target and an increased uncertainty by two orders of magnitude. Significance . A dedicated phantom was designed and developed for breathing motion assessment of dose deposition during carbon ion radiotherapy. PPIeT is a unique tool for dose verification in the pancreas and its organs at risk during end-to-end tests.
- 11 December 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (24) , 245013
Open AccessA phantom to simulate organ motion and its effect on dose distribution in carbon ion therapy for pancreatic cancer
Objective . Carbon ion radiotherapy is a promising radiation technique for malignancies like pancreatic cancer. However, organs’ motion imposes challenges for achieving homogeneous dose delivery. In this study, an anthropomorphic P ancreas P hantom for I on-b e am T herapy (PPIeT) was developed to simulate breathing and gastrointestinal motion during radiotherapy. Approach . The developed phantom contains a pancreas, two kidneys, a duodenum, a spine and a spinal cord. The shell of the organs was 3D printed and filled with agarose-based mixtures. Hounsfield Units (HU) of PPIeTs’ organs were measured by CT. The pancreas motion amplitude in cranial-caudal (CC) direction was evaluated from patients’ 4D CT data. Motions within the obtained range were simulated and analyzed in PPIeT using MRI. Additionally, GI motion was mimicked by changing the volume of the duodenum and quantified by MRI. A patient-like treatment plan was calculated for carbon ions, and the phantom was irradiated in a static and moving condition. Dose measurements in the organs were performed using an ionization chamber and dosimetric films. Main results . PPIeT presented tissue equivalent HU and reproducible breathing-induced CC displacements of the pancreas between (3.98 ± 0.36) mm and a maximum of (18.19 ± 0.44) mm. The observed maximum change in distance of (14.28 ± 0.12) mm between pancreas and duodenum was consistent with findings in patients. Carbon ion irradiation revealed homogenous coverage of the virtual tumor at the pancreas in static condition with a 1% deviation from the treatment plan. Instead, the dose delivery during motion with the maximum amplitude yielded an underdosage of 21% at the target and an increased uncertainty by two orders of magnitude. Significance . A dedicated phantom was designed and developed for breathing motion assessment of dose deposition during carbon ion radiotherapy. PPIeT is a unique tool for dose verification in the pancreas and its organs at risk during end-to-end tests.