RZRu Zhang

Ru Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ru Zhang has a total of 46 co-authors. Here are the top co-authors by number of shared publications:

  • Kun Qian

    State Key Laboratory of Systems Medicine for Cancer, School of Biomedical Engineering, Institute of Medical Robotics and Shanghai Academy of Experimental Medicine, Shanghai Jiao Tong University, Shanghai, 200030, P. R. China

    7 shared publications
  • Wei Xu

    School of Biomedical Engineering, Med-X Research Institute , Shanghai Jiao Tong University , Shanghai 200030 , P. R. China

    5 shared publications
  • Jingjing Wan

    School of Chemistry and Molecular Engineering , East China Normal University , Shanghai 200241 , P. R. China

    3 shared publications
  • Lin Huang

    School of Biomedical Engineering Shanghai Jiao Tong University Shanghai 200030 China

    3 shared publications
  • Xuming Sun

    School of Biomedical Engineering Shanghai Jiao Tong University Shanghai 200030 China

    3 shared publications
  • Biao Le

    NanoLite Systems Austin TX 78795 USA

    2 shared publications

Latest Publications

  • Open Access

    Diagnosis and prognosis of myocardial infarction on a plasmonic chip

    by Wei Xu, Lin Wang, Ru Zhang, Xuming Sun, Lin Huang, Haiyang Su, Xunbin Wei, Chia-Chun Chen, Jiatao Lou, Hongjie Dai, et al.

    Cardiovascular diseases lead to 31.5% of deaths globally, and particularly myocardial infarction (MI) results in 7.4 million deaths per year. Diagnosis of MI and monitoring for prognostic use are critical for clinical management and biomedical research, which require advanced tools with accuracy and speed. Herein, we developed a plasmonic gold nano-island (pGold) chip assay for diagnosis and monitoring of MI. On-chip microarray analysis of serum biomarkers (e.g., cardiac troponin I) afforded up to 130-fold enhancement of near-infrared fluorescence for ultra-sensitive and quantitative detection within controlled periods, using 10 μL of serum only. The pGold chip assay achieved MI diagnostic sensitivity of 100% and specificity of 95.54%, superior to the standard chemiluminescence immunoassay in cardiovascular clinics. Further, we monitored biomarker concentrations regarding percutaneous coronary intervention for prognostic purpose. Our work demonstrated a designed approach using plasmonic materials for enhanced diagnosis and monitoring for prognostic use towards point-of-care testing.


  • Label-Free Electrochemical Sensor for CD44 by Ligand-Protein Interaction

    by Ru Zhang, Chandrababu Rejeeth, Wei Xu, Chuanying Zhu, Xiyuan Liu, Jingjing Wan, Mawei Jiang, Kun Qian

    Detection of biomarkers in bio-systems plays a key role in advanced bio-diagnostics for research and clinical use. Design of new analytical platforms is challenging and in demand, addressing molecular capture and subsequent quanti-tation. Herein, we developed a label-free electrochemical sensor for CD44 by ligand-protein interaction. We assembled car-bon nanotube composites on the electrode to enhance electronic conductivity by 6.2-fold and reduce over-potential with a shift of 77 mV. We conjugated hyaluronic acid (HA) to the surface of carbon nanotubes via electrostatic interaction be-tween HA and poly (diallyldimethylammonium chloride) (PDDA). Consequently, we performed direct electrochemical sens-ing of CD44 with dynamic range of 0.01-100 ng/mL and detection limit of 5.94 pg/mL without any post-labeling for ampli-fication, comparable to the best current results. The sensor also displayed high selectivity, reproducibility with relative stand-ard deviation (RSD, n=5) of 2.57%, and long-term stability for 14 days. We demonstrated applications of sensor in detection of human serum and cancer cells. Our work guides the development of more sensor types by ligand-protein interactions and contributes to design of interfaces in given bio-systems for diagnosis.


  • Magnetic “Squashing” of Circulating Tumor Cells on Plasmonic Substrates for Ultrasensitive NIR Fluorescence Detection

    by Ru Zhang, Biao Le, Wei Xu, Kai Guo, Xuming Sun, Haiyang Su, Lin Huang, Jingyi Huang, Ting Shen, Tao Liao, et al.

    Detection of circulating tumor cells (CTCs) in patient's blood is an important approach to cancer diagnosis and prognosis, but has been challenging due to the rarity of cells. Here, a magnetic‐enhanced capturing of CTCs onto a plasmonic gold (pGOLD) chip, through a microfluidic immunomagnetic method, is demonstrated. Owing to the squashed/flattened morphology of cancer cells by magnetic forces and the resulting close proximity of near‐infrared (NIR) labels on cells to the pGOLD surface, an ultrahigh NIR fluorescence enhancement of ≈50–120‐fold is observed, drastically enhancing the ability of CTC detection, imaging, and analysis. Fluorescence enhanced, multiplexed protein biomarkers detection of CTCs is conducted for cancer cell spiked samples as well as CTCs in cancer patient's blood. Low CTC concentrations are detected down to ≈1 cell mL−1 with capture efficiency up to ≈90%. Mechanical manipulation of cells by magnetic and other forces on plasmonic substrates represents a promising approach to ultrasensitive bio‐analytical applications.


  • Combined immunomagnetic capture coupled with ultrasensitive plasmonic detection of circulating tumor cells in blood

    by Weiyu Shen, Yi Song, Alison Burklund, Biao Le, Ru Zhang, Lijie Wang, Yong Xi, Kun Qian, Ting Shen, John X. J. Zhang

    We demonstrate enhanced on-chip circulating tumor cell (CTC) detection through the incorporation of plasmonic-enhanced near-infrared (NIR) fluorescence screening. Specifically, the performance of plasmonic gold coated chips was evaluated on our previously reported immunomagnetic CTC capture system and compared to the performance of a regular chip. Three main performance metrics were evaluated: capture efficiency, capture reproducibility, and clinical efficacy. Use of the plasmonic chip to capture SK-BR-3 cells in PBS, resulted in a capture efficiency of 82%, compared to 76% with a regular chip. Both chips showed excellent capture reproducibility for all three cells lines evaluated (MCF-7, SK-BR-3, Colo 205) in both PBS and peripheral blood, with R2 values ranging from 0.983 to 0.996. Finally, performance of the plasmonic chip was evaluated on thirteen peripheral blood samples in patients with both breast and prostate cancer. The regular chip detected 2–8 cells per 5 mL of blood, while the plasmonic chip detected 8–85 cells per 5 mL of blood in parallel samples. In summary, we successfully demonstrate improved CTC capture and detection capabilities through use of plasmonic-enhanced near-infrared (NIR) fluorescence screening in both in vitro and ex vivo experiments. This work not only has the potential to improve clinical outcomes though improved CTC analysis, but also demonstrates successful interface design between plasmonic materials and cell capture for bioanalytical applications.


  • Detection and Inhibition of Bacteria on a Dual‐Functional Silver Platform

    by Vadanasundari Vedarethinam, Lin Huang, Wei Xu, Ru Zhang, Deepanjali D. Gurav, Xuming Sun, Jing Yang, Ruoping Chen, Kun Qian

    Detection and inhibition of bacteria are universally required in clinics and daily life for health care. Developing a dual‐functional material is challenging and in demand, engaging advanced applications for both defined bioanalysis and targeted biotoxicity. Herein, magnetic silver nanoshells are designed as a multifunctional platform for the detection and inhibition of bacteria. The optimized magnetic silver nanoshells enable direct laser desorption/ionization mass spectrometry based metabolic analysis of bacteria (≈10 µL−1), in complex biofluids. The serum infection process (0–10 h) is monitored by statistics toward clinical classification. Moreover, magnetic silver nanoshells facilitate surface adhesion on bacteria due to nanoscale surface roughness and thus display long‐term antibacterial effects. Bacteria metabolism is studied with metabolic biomarkers (e.g., malate and lysine) identified during inhibition, showing cell membrane destruction and dysfunctional protein synthesis mechanisms. This work not only guides the design of material‐based approaches for bioanalysis and biotoxicity, but contributes to bacteria‐related diagnosis by using specific metabolic biomarkers for sensitive detection and new insights by monitoring metabolomic change of bacteria for antibacterial applications.


  • Open Access

    Metabolic Fingerprinting on a Plasmonic Gold Chip for Mass Spectrometry Based in Vitro Diagnostics

    by Xuming Sun, Lin Huang, Ru Zhang, Wei Xu, Jingyi Huang, Deepanjali D. Gurav, Vadanasundari Vedarethinam, Ruoping Chen, Jiatao Lou, Qian Wang, et al.

    Current metabolic analysis is far from ideal to engage clinics and needs rationally designed materials and device. Here we developed a novel plasmonic chip for clinical metabolic fingerprinting. We first constructed a series of chips with gold nanoshells on the surface through controlled particle synthesis, dip-coating, and gold sputtering for mass production. We integrated the optimized chip with microarrays for laboratory automation and micro-/nanoscaled experiments, which afforded direct high-performance metabolic fingerprinting by laser desorption/ionization mass spectrometry using 500 nL of various biofluids and exosomes. Further we for the first time demonstrated on-chip in vitro metabolic diagnosis of early stage lung cancer patients using serum and exosomes. This work initiates a new bionanotechnology based platform for advanced metabolic analysis toward large-scale diagnostic use.


  • Extraction, detection, and profiling of serum biomarkers using designed Fe3O4@SiO2@HA core–shell particles

    by Chandrababu Rejeeth, Xuechao Pang, Ru Zhang, Wei Xu, Xuming Sun, Bin Liu, Jiatao Lou, Jingjing Wan, Hongchen Gu, Wei Yan, et al.

    Serum biomarkers in the form of proteins (e.g. cluster of differentiation-44 (CD44)) have been demonstrated to have high clinical sensitivity and specificity for disease diagnosis and prognosis. Owing to the high sample complexity and low molecular abundance in serum, the detection and profiling of biomarkers rely on efficient extraction by materials and devices, mostly using immunoassays via antibody-antigen recognition. Antibody-free approaches are promising and need to be developed for real-case applications in serum to address the limitations of antibody-based techniques in terms of robustness, expense, and throughput. In this work, we demonstrated a novel approach using hyaluronic acid (HA)-modified materials/devices for the extraction, detection, and profiling of serum biomarkers via ligand-protein interactions. We constructed Fe3O4@SiO2@HA particles with different sizes through layer-by-layer assembly and for the first time applied HA-functionalized particles in the facile extraction and sequence identification of CD44 in serum by mass spectrometry. We also first validated HA-CD44 binding through electrochemical sensing using HA-modified electrodes in both standard solutions and diluted serum samples, achieving a detection limit of ~0.6 ng/mL and a linear response range from 1 ng/mL to 10 μg/mL. Furthermore, we performed profiling of HA-binding serum proteome, providing a new preliminary benchmark for the construction of future databases, and we investigated selected surface chemistries of particles for the capture of proteins in serum. Our work not only resulted in the development of a platform technology for CD44 extraction/detection and HA-binding proteome identification, but also guided the design of ligand affinity-based approaches for antibody-free analysis of serum biomarkers towards diagnostic applications.


  • Open Access

    Assessment of duodenogastric reflux by combined continuous intragastric pH and bilirubin monitoring

    by Fei Dai, Jun Gong, Ru Zhang, Jin-Yan Luo, You-Ling Zhu, Xue-Qin Wang

    AIM: To assess the diagnostic value of a combination of continuous intragastric pH and bilirubin monitoring in the detection of duodenogastric reflux (DGR), and the effects of diet on the bilirubin absorbance. METHODS: 30 healthy volunteers were divided into two groups: standard diet group (Group 1) 18 cases, free diet group (Group 2) 12 cases. Each subjects were subjected to simultaneous 24 h intragastric pH and spectrophotometric bilirubin concentration monitoring (Bilitec 2000). RESULTS: There was no difference of preprandial phase bilirubin absorbance between two groups. The absorbance of postprandial phase was significantly increased in group 2 than group 1. There was no difference between preprandial phase and postprandial phase absorbance in group 1. Postprandial phase absorbance was significantly higher in group 2. In a comparison of bile reflux with intragastric pH during night time, there were 4 types of reflux: Simultaneous increase in absorbance and pH in only 19.6%, increase in bilirubin with unchanged pH 33.3%, pH increase with unchanged absorbance 36.3%, and both unchanged in 10.8%. Linear regression analysis showed no correlation between percentage total time of pH < 4 and percentage total time of absorbance > 0.14, r = 0.068, P < 0.05. CONCLUSION: Because of the dietary effect, high absorbance fluids or foods should be avoided in detection. Intragastric pH and bilirubin monitoring separately predict the presence of duodenal (and/or pancreatic) reflux and bile reflux. They can not substitute for each other. The detection of DGR is improved if the two parameters are combined simultaneously.