Caroline M. Komlo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Caroline M. Komlo has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
Prashanth Vallabhajosyula
Division of Cardiovascular Surgery, University of Pennsylvania, Philadelphia, Pennsylvania
8 shared publicationsWilson Y. Szeto
Division of Cardiovascular Surgery, University of Pennsylvania, Philadelphia, Pennsylvania
7 shared publications- Joseph E. Bavaria
University of Pennsylvania
6 shared publications - Prashanth Vallabhajosyula
Division of Cardiac Surgery, Department of Surgery, Yale School of Medicine, New Haven, CT 06519, USA
6 shared publications Joseph E. Bavaria
Division of Cardiovascular Surgery, University of Pennsylvania, Philadelphia, Pennsylvania
5 shared publicationsNimesh D. Desai
Division of Cardiovascular Surgery, University of Pennsylvania, Philadelphia, Pennsylvania
5 shared publications
Latest Publications
- 20 June 2023
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 17 (5) , 2305-2313
Endoaortic balloon occlusion versus transthoracic cross-clamp for totally endoscopic robotic mitral valve surgery: a retrospective cohort study
Endoaortic balloon occlusion (EABO) and transthoracic cross-clamping have been shown to have comparable safety profiles for aortic occlusion in minimally invasive mitral valve surgery (MIMVS). However, few studies have focused exclusively on the totally endoscopic robotic approach. We sought to compare outcomes for patients undergoing totally endoscopic robotic mitral valve surgery with aortic occlusion via EABO and transthoracic clamping after a period where EABO was unavailable required us to use the transthoracic clamp. Retrospective review identified 113 patients who underwent robotic mitral valve surgery at our facility between 2019 and 2021 with EABO (n = 71) or transthoracic clamping (n = 42). Relevant data were extracted and compared. Preoperative characteristics were similar other than a higher rate of coronary artery disease [EABO: 69.0% (49/71) vs clamp: 45.2% (19/42), p = .02] and chronic lung disease [EABO: 38.0% (27/71) vs clamp: 9.5% (4/42), p < .01] in the EABO group. Median percutaneous cardiopulmonary bypass time, operative time, and cross-clamp time were comparable. Similar rates of postoperative bleeding complications were observed, and no aortic complications were observed. One patient in each group underwent conversion to an open approach. 30-day mortality and readmission rates were comparable. EABO and transthoracic clamp were associated with similar bleeding and aortic outcomes, and mortality and readmission rates were comparable at thirty days postoperatively. Our findings support the comparable safety of the two techniques, which is well documented in studies encompassing all MIMVS techniques, within the specific context of the totally endoscopic robotic approach.
- 20 June 2023
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 17 (5) , 2305-2313
Endoaortic balloon occlusion versus transthoracic cross-clamp for totally endoscopic robotic mitral valve surgery: a retrospective cohort study
Endoaortic balloon occlusion (EABO) and transthoracic cross-clamping have been shown to have comparable safety profiles for aortic occlusion in minimally invasive mitral valve surgery (MIMVS). However, few studies have focused exclusively on the totally endoscopic robotic approach. We sought to compare outcomes for patients undergoing totally endoscopic robotic mitral valve surgery with aortic occlusion via EABO and transthoracic clamping after a period where EABO was unavailable required us to use the transthoracic clamp. Retrospective review identified 113 patients who underwent robotic mitral valve surgery at our facility between 2019 and 2021 with EABO (n = 71) or transthoracic clamping (n = 42). Relevant data were extracted and compared. Preoperative characteristics were similar other than a higher rate of coronary artery disease [EABO: 69.0% (49/71) vs clamp: 45.2% (19/42), p = .02] and chronic lung disease [EABO: 38.0% (27/71) vs clamp: 9.5% (4/42), p < .01] in the EABO group. Median percutaneous cardiopulmonary bypass time, operative time, and cross-clamp time were comparable. Similar rates of postoperative bleeding complications were observed, and no aortic complications were observed. One patient in each group underwent conversion to an open approach. 30-day mortality and readmission rates were comparable. EABO and transthoracic clamp were associated with similar bleeding and aortic outcomes, and mortality and readmission rates were comparable at thirty days postoperatively. Our findings support the comparable safety of the two techniques, which is well documented in studies encompassing all MIMVS techniques, within the specific context of the totally endoscopic robotic approach.
- 18 April 2023
- Published by Elsevier in Journal of Surgical Research
- Vol. 289, 35-41
Feasibility of Postoperative Day One or Day Two Discharge After Robotic Cardiac Surgery
- 18 April 2023
- Published by Elsevier in Journal of Surgical Research
- Vol. 289, 35-41
Feasibility of Postoperative Day One or Day Two Discharge After Robotic Cardiac Surgery
- 24 November 2022
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 37 (12) , 4803-4807
Routine endoscopic robotic cardiac tumor resection using an 8‐mm working port and percutaneous cannulation
Prior studies have demonstrated robotic excision of cardiac tumors as a safe and effective treatment option. The procedure is performed with five incisions: three robotic arm ports, one atrial retractor port, and one working port. We report our unique initial experience in robotic tumor removal. To our knowledge, this is one of the first reports demonstrating cardiac myxoma and fibroelastoma removal with use of exclusively 8-mm ports. All data for robotic cardiac tumor resection at our institution from June 2019 to December 2021 were retrospectively collected; 18 cases were included, including 13 cardiac myxomas and five fibroelastomas. Baseline demographics, intraoperative characteristics, and surgical outcomes were recorded. Descriptive statistics were calculated; continuous variables were reported as median [interquartile range], and categorical variables were reported as percentages. Median patient age was 64 [55, 70] years old. The cohort consisted of primarily female (67%) and white (83%) patients. Median body mass index was 26.3 [23.0, 31.5] kg/m2 . 11% of patients were current tobacco users and 50% had hypertension. All patients underwent myxoma or fibroelastoma removal with the use of five 8-mm robotic ports. Each patient underwent percutaneous cannulation via the femoral arteries. Aortic occlusion was achieved via an endoaortic balloon (67%) or transthoracic cross-clamp (33%). Cross-clamp time was 30 [26, 41] minutes. Concomitant procedures performed during myxoma removal included patent foramen ovale closure (28%), mitral valve repair (8%), left atrial appendage closure (8%), Cox-maze procedure (6%), and coronary artery bypass grafting (6%). All cardiac tumors were packaged with use of the endo-bag and subsequently removed through the working port. Maximal myxoma and fibroelastoma diameters were 2.5 [1.7, 3.5] and 0.6 [0.4, 0.7] cm, respectively. Procedural cardiopulmonary bypass time was 77 [65, 84] minutes. No intraoperative mortality, reoperation for bleeding, or postoperative cardiac issues were recorded. One in-hospital mortality occurred as the result of a thrombotic event in the context of a hypercoagulable state unrelated to the patient's operation. No other mortalities were observed at 30 days. Hospital length of stay was 4.5 [3.0, 7.8] days. In our study, the robotic platform facilitated safe and effective cardiac tumor excision. Our results highlight the efficacy of 8-mm port sizing and the concurrent use of other minimally invasive techniques, including percutaneous cannulation, in this patient population. In general, patients prefer the least invasive treatment option available. Our findings emphasize the importance of training cardiac surgeons to perform robotic procedures using the least invasive means possible to provide patients with various options for their treatment.
- 24 November 2022
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 37 (12) , 4803-4807
Routine endoscopic robotic cardiac tumor resection using an 8‐mm working port and percutaneous cannulation
Prior studies have demonstrated robotic excision of cardiac tumors as a safe and effective treatment option. The procedure is performed with five incisions: three robotic arm ports, one atrial retractor port, and one working port. We report our unique initial experience in robotic tumor removal. To our knowledge, this is one of the first reports demonstrating cardiac myxoma and fibroelastoma removal with use of exclusively 8-mm ports. All data for robotic cardiac tumor resection at our institution from June 2019 to December 2021 were retrospectively collected; 18 cases were included, including 13 cardiac myxomas and five fibroelastomas. Baseline demographics, intraoperative characteristics, and surgical outcomes were recorded. Descriptive statistics were calculated; continuous variables were reported as median [interquartile range], and categorical variables were reported as percentages. Median patient age was 64 [55, 70] years old. The cohort consisted of primarily female (67%) and white (83%) patients. Median body mass index was 26.3 [23.0, 31.5] kg/m2 . 11% of patients were current tobacco users and 50% had hypertension. All patients underwent myxoma or fibroelastoma removal with the use of five 8-mm robotic ports. Each patient underwent percutaneous cannulation via the femoral arteries. Aortic occlusion was achieved via an endoaortic balloon (67%) or transthoracic cross-clamp (33%). Cross-clamp time was 30 [26, 41] minutes. Concomitant procedures performed during myxoma removal included patent foramen ovale closure (28%), mitral valve repair (8%), left atrial appendage closure (8%), Cox-maze procedure (6%), and coronary artery bypass grafting (6%). All cardiac tumors were packaged with use of the endo-bag and subsequently removed through the working port. Maximal myxoma and fibroelastoma diameters were 2.5 [1.7, 3.5] and 0.6 [0.4, 0.7] cm, respectively. Procedural cardiopulmonary bypass time was 77 [65, 84] minutes. No intraoperative mortality, reoperation for bleeding, or postoperative cardiac issues were recorded. One in-hospital mortality occurred as the result of a thrombotic event in the context of a hypercoagulable state unrelated to the patient's operation. No other mortalities were observed at 30 days. Hospital length of stay was 4.5 [3.0, 7.8] days. In our study, the robotic platform facilitated safe and effective cardiac tumor excision. Our results highlight the efficacy of 8-mm port sizing and the concurrent use of other minimally invasive techniques, including percutaneous cannulation, in this patient population. In general, patients prefer the least invasive treatment option available. Our findings emphasize the importance of training cardiac surgeons to perform robotic procedures using the least invasive means possible to provide patients with various options for their treatment.
- 1 September 2022
- Published by AME Publishing Company in ASVIDE
- Vol. 9, 184
How I perform totally percutaneous robotic mitral valve repair.
- 1 September 2022
- Published by AME Publishing Company in ASVIDE
- Vol. 9, 184
How I perform totally percutaneous robotic mitral valve repair.
- Open Access
- 30 June 2021
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 36 (10) , 3860-3861
Showcasing the lateral approach for robotic aortic and mitral valve surgery: Does one approach fit it all?
- 30 June 2021
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 36 (10) , 3860-3861
Open AccessShowcasing the lateral approach for robotic aortic and mitral valve surgery: Does one approach fit it all?
- 30 May 2021
- Published by Hindawi Limited in Journal of Cardiac Surgery
- Vol. 36 (9) , 3163-3165
Commentary: Sternotomy closure in high‐risk patients: Is longitudinal rigid sternal fixation the optimal approach?
Click on the article title to read more.
- 30 May 2021
- Published by Hindawi Limited in Journal of Cardiac Surgery
- Vol. 36 (9) , 3163-3165
Commentary: Sternotomy closure in high‐risk patients: Is longitudinal rigid sternal fixation the optimal approach?
Click on the article title to read more.
- 12 February 2021
- Published by Wiley in Artificial Organs
- Vol. 45 (4) , 332-335
On the path to permanent artificial heart technology: Greater energy independence is paramount
- 12 February 2021
- Published by Wiley in Artificial Organs
- Vol. 45 (4) , 332-335
On the path to permanent artificial heart technology: Greater energy independence is paramount
- 6 August 2018
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 107 (1) , 68-75
Functional Outcomes of Type I Bicuspid Aortic Valve Repair With Annular Stabilization: Subcommissural Annuloplasty Versus External Subannular Aortic Ring
- 6 August 2018
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 107 (1) , 68-75
Functional Outcomes of Type I Bicuspid Aortic Valve Repair With Annular Stabilization: Subcommissural Annuloplasty Versus External Subannular Aortic Ring
- 10 July 2017
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 32 (8) , 494-499
Central cannulation strategy for extent I thoracoabdominal aneurysm repair of chronic type B aortic dissection
We evaluated the safety profile of a central cardiopulmonary bypass (CPB) cannulation strategy for repair of extent I thoracoabdominal aortic aneurysms (TAAA) with chronic type B dissection in comparison to traditional peripheral CPB cannulation strategies. Patients undergoing extent I TAAA repair for chronic type B dissection from 2002 to 2011 were retrospectively reviewed. Patients were grouped by their CPB cannulation strategy. Patients in Group I underwent central aortic cannulation (n = 28) through a left thoracotomy incision. The true lumen of the descending thoracic aorta was cannulated using an echocardiogram-guided Seldinger wire technique. The right atrium was directly accessed for venous drainage. In Group II (n = 31), arterial and venous cannulation of the femoral vessels was achieved using a left-sided groin incision. All patients underwent deep hypothermic circulatory arrest for proximal aortic reconstruction. Preoperative aortic dimensions (6.5 ± 0.79 cm in Group I vs 7.0 ± 1.15 cm in Group II p = 0.8) were similar between groups. CPB time (240 ± 37 min in Group I vs 174 ± 68 min in Group II p < 0.01) was significantly higher in the central cannulation group whereas circulatory arrest times (43 ± 5 min Group I vs 37 ± 7 min in Group II p = 0.1) were similar between the two groups. In-hospital 30-day mortality (N = 0, 0% in Group I; N = 2, 6.5% in Group II), stroke (N = 1, 3.5% in Group I; N = 0, 0% in Group II), paraplegia (N = 1, 3.5% in Group I; N = 1, 3.2% in Group II), reoperation for bleeding (N = 1, 3.5% in Group I; N = 1, 3.2% Group II), tracheostomy rate (N = 2, 7% in Group I; N = 3, 9.7% Group II), and mean length of stay (19 days in Group I vs 17 days in Group II) were similar (p > 0.05). Median follow-up was 3.6 ± 2.0 in Group I and 5.6 ± 2.6 years in Group II. Actuarial survival at 5 years was 84.6 % for Group I and 77.6% for Group II (p = 0.52). Central true lumen cannulation through a left thoracotomy incision for repair of extent I TAAA with chronic type B dissection is an acceptable approach with equivalent early and midterm outcomes compared to more standard femoral cannulation techniques. It may provide a safe alternative cannulation site for patients with diseased femoral vessels.
- 10 July 2017
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 32 (8) , 494-499
Central cannulation strategy for extent I thoracoabdominal aneurysm repair of chronic type B aortic dissection
We evaluated the safety profile of a central cardiopulmonary bypass (CPB) cannulation strategy for repair of extent I thoracoabdominal aortic aneurysms (TAAA) with chronic type B dissection in comparison to traditional peripheral CPB cannulation strategies. Patients undergoing extent I TAAA repair for chronic type B dissection from 2002 to 2011 were retrospectively reviewed. Patients were grouped by their CPB cannulation strategy. Patients in Group I underwent central aortic cannulation (n = 28) through a left thoracotomy incision. The true lumen of the descending thoracic aorta was cannulated using an echocardiogram-guided Seldinger wire technique. The right atrium was directly accessed for venous drainage. In Group II (n = 31), arterial and venous cannulation of the femoral vessels was achieved using a left-sided groin incision. All patients underwent deep hypothermic circulatory arrest for proximal aortic reconstruction. Preoperative aortic dimensions (6.5 ± 0.79 cm in Group I vs 7.0 ± 1.15 cm in Group II p = 0.8) were similar between groups. CPB time (240 ± 37 min in Group I vs 174 ± 68 min in Group II p < 0.01) was significantly higher in the central cannulation group whereas circulatory arrest times (43 ± 5 min Group I vs 37 ± 7 min in Group II p = 0.1) were similar between the two groups. In-hospital 30-day mortality (N = 0, 0% in Group I; N = 2, 6.5% in Group II), stroke (N = 1, 3.5% in Group I; N = 0, 0% in Group II), paraplegia (N = 1, 3.5% in Group I; N = 1, 3.2% in Group II), reoperation for bleeding (N = 1, 3.5% in Group I; N = 1, 3.2% Group II), tracheostomy rate (N = 2, 7% in Group I; N = 3, 9.7% Group II), and mean length of stay (19 days in Group I vs 17 days in Group II) were similar (p > 0.05). Median follow-up was 3.6 ± 2.0 in Group I and 5.6 ± 2.6 years in Group II. Actuarial survival at 5 years was 84.6 % for Group I and 77.6% for Group II (p = 0.52). Central true lumen cannulation through a left thoracotomy incision for repair of extent I TAAA with chronic type B dissection is an acceptable approach with equivalent early and midterm outcomes compared to more standard femoral cannulation techniques. It may provide a safe alternative cannulation site for patients with diseased femoral vessels.
- 1 October 2016
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 102 (4) , 1221-1228
Bicuspid Aortic Insufficiency With Aortic Root Aneurysm: Root Reimplantation Versus Bentall Root Replacement
- 1 October 2016
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 102 (4) , 1221-1228
Bicuspid Aortic Insufficiency With Aortic Root Aneurysm: Root Reimplantation Versus Bentall Root Replacement