AEAndreas Edel

Andreas Edel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andreas Edel has a total of 178 co-authors. Here are the top co-authors by number of shared publications:

  • Claudia Spies

    Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Department of Anesthesiology and Intensive Care Medicine (CCM | CVK), Augustenburger Platz 1, 13353 Berlin, Germany

    10 shared publications
  • Elias Grünewald

    Institute of Medical Informatics, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany

    4 shared publications
  • Felix Balzer

    Institute of Medical Informatics, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany

    4 shared publications
  • Jayanth Sreekanth

    Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Department of Anesthesiology and Intensive Care Medicine (CCM | CVK), Augustenburger Platz 1, 13353 Berlin, Germany

    4 shared publications
  • Nicolas Paul

    Department of Anesthesiology and Intensive Care Medicine (CCM/CVK), Charité – Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany

    4 shared publications
  • Anatol-Fiete Näher

    Digital Global Public Health, Hasso Plattner Institute, University of Potsdam, Potsdam, Germany

    3 shared publications

Latest Publications

  • Open Access

    Effect of Data Preprocessing Decisions on Sepsis-3 Labels in MIMIC-III and eICU-CRD: A Sensitivity Analysis

    by Falk Meyer-Eschenbach, Johannes V. Stoephasius, Anatol-Fiete Näher, Fabian Kohlbacher, Severin Kohler, Elias Grünewald, Nicolas Frey, Andreas Edel, Jon Barrenetxea, Felix Balzer, et al.

    Objective: Published Sepsis-3 detection rates range from 3.4 % to 65.2 % in MIMIC-III and from 9.8 % to 47.9 % in eICU-CRD. We tested whether data preprocessing decisions alone produce differences of this magnitude when data, cohort and sepsis definition are held fixed. Materials and Methods: Using the MIMIC-III and eICU-CRD databases we developed and applied a configurable pipeline (medalabel) that stepwise maps the databases into the OMOP Common Data Model, standardizes and cleans the data, and preprocesses them to compute Sepsis-3 labels. Each setting of the preprocessing represents one decision of published Sepsis-3 implementations, and settings can be freely combined. On fixed cohorts of first ICU stays (13,388 in MIMIC-III, 94,782 in eICU-CRD), we changed one setting of a reference configuration at a time (51 variants in five preprocessing domains) and compared detection rates and septic stays (Jaccard index) with the reference. We approximately reconstructed six published pipelines and combined the settings with the largest effects in pairs to test whether their effects add up. The time a value is measured can differ from the time it is documented and thus available for automated analysis. Beyond the usual retrospective view based on measurement time, the pipeline optionally combines both time points to simulate a real-time system. Results: The reference configuration labelled 31.5 % of ICU stays in MIMIC-III and 8.2 % in eICU-CRD as septic. Changing a single setting resulted in sepsis detection rates of 15.3-58.6 % in MIMIC-III and 4.6-17.2 % in eICU-CRD. The largest shifts from the reference, all in the same direction in both databases, came from the SOFA baseline, up to +27.1 percentage points (pp) in MIMIC-III and +9.0 pp in eICU-CRD, from disabling imputation (-16.3 and -2.5 pp), the temporal window (+12.6 and +5.3 pp) and aggregation (-10.1 and -0.8 pp); clinician-validated parameter sets had little effect (-4.8 and -1.1 pp). Even variants that changed the rate by less than 2 pp labelled partly different patients, with Jaccard indices as low as 0.67 in MIMIC-III and 0.56 in eICU-CRD (1 = identical septic stays). Reconstructions deviated from the published rates by 2-10 pp. Two settings applied together deviated from the sum of their single effects by 0.9-11.8 pp in MIMIC-III and by up to 4.9 pp in eICU-CRD. Simulating a real-time system lowered the MIMIC-III rate by 5.0 pp and delayed the label in 45 % of the stays that remained septic. Discussion: With the infection criterion held fixed, preprocessing decisions alone can produce a considerable part of the variation between published sepsis detection rates. Similar rates can stem from different patients, which makes studies and prediction models difficult to compare, and retrospective labels rely on values that a real-time system would not yet have. Conclusion: Sepsis-3 labels from health records are only comparable if their data preprocessing is known. Configurable pipelines allow quantifying the effect of these decisions, computing alternative labels on the same data and, in future, validating them against clinician-adjudicated cases.

  • Open Access

    Variability in automated sepsis case detection: a systematic analysis of implementation methods in clinical data repositories

    by Falk Meyer-Eschenbach, René Schmiedler, Johannes von Stoephasius, Camille Zhang, Luis Kronfli, Nicolas Frey, Anatol-Fiete Näher, Jacques Ehret, Johanna Nothacker, Christof von Kalle, et al.

    Objective: To systematically review and characterize methodological heterogeneity in sepsis case detection using the Medical Information Mart for Intensive Care III (MIMIC-III) and eICU-CRD databases. Materials and Methods: We conducted a PRISMA-guided systematic review of PubMed and Web of Science (publication years 2016-2024). Studies were eligible if they applied the SOFA-based Sepsis-3 definition to MIMIC-III or eICU-CRD, provided at least one explicit label-calculation detail, reported a traceable detection rate, and met further criteria detailed in the PRISMA flow diagram. We classified each study by study type and unit of analysis (patients, admissions, or ICU stays) and extracted methodological details on sepsis case detection across 6 domains. For studies with available source code, we additionally examined code structure and repository dependencies to identify methodological decisions across these domains. Results: Of 396 publications screened, 64 met inclusion criteria and 12 provided source code. Sepsis detection rates ranged from 3.4% to 65.2% in MIMIC-III and from 9.8% to 47.9% in eICU-CRD. Substantial variability persisted among studies using identical cohort definitions within both databases (MIMIC-III: 16.9%-42.2%; eICU-CRD: 13.9%-31.4%). In a generalized linear mixed model, between-study heterogeneity was extreme (overall τ²≈0.79; 95% prediction interval for a new study’s detection rate 5%–63%), and study-level characteristics—including database, study type, infection detection method, code availability, and unit of analysis—explained only a small proportion of this variance (≈9%), with no characteristic reaching statistical significance. The overall proportion of studies reporting methodological details varied by domain: SOFA calculation (53.1%), infection detection methods (42.2%), temporal windows (37.5%), aggregation methods (26.6%), and missing-data handling (17.2%). Source code analysis identified 321 implementation decisions, revealing heterogeneity in baseline SOFA definitions (SOFA = 0 vs dynamic baseline), temporal windows (infection-centered vs ICU-admission-centered) and infection detection methods (antibiotic-culture matching vs APACHE-based diagnosis). Dependencies among several MIMIC-III repositories suggested propagation of implementation decisions across studies. Discussion: Clinically validated sepsis definitions yield substantially different detection rates across studies using identical datasets. Statistical modeling showed that this variability is driven almost entirely by between-study implementation differences rather than sampling error or study characteristics. Conclusion: To improve reproducibility in sepsis research and the robustness of sepsis prediction models, we recommend standardized reporting of sepsis case detection methodology and the publication of version-controlled source code.

  • Open Access

    rhythmCI: an R package for rhythm detection using harmonic regression amplitude confidence intervals

    by Jayanth Sreekanth, Andreas Edel, Claudia Spies, Sandro Andreotti, Bharath Ananthasubramaniam

    Background: Circadian clocks are evolutionarily conserved systems that orchestrate daily rhythms in human physiology, tissue behavior, and cellular function. In circadian research, the NanoString nCounter platform has emerged as a robust alternative to microarray and RNA sequencing. However, raw instrument output requires specialized preprocessing to handle technical noise. Furthermore, while harmonic regression is widely used to detect periodic signals in biological time-series data, evaluating rhythmicity remains highly challenging in clinical studies characterized by sparse sampling and small sample sizes. Results: To address these limitations, we developed rhythmCI, an easy-to-use R package that integrates established normalization methods with a complete workflow for circadian data analysis. The package incorporates a bootstrapping procedure to estimate confidence intervals for harmonic regression amplitudes, offering a statistically transparent way to quantify rhythmicity in small-cohort studies. rhythmCI provides an end-to-end workflow for NanoString nCounter data, including automated preprocessing, normalization, and visualization. We evaluated the utility and accuracy of the package using synthetic time-series data generated with the Simphony framework, demonstrating that rhythmCI produces interpretable and reliable rhythmicity classifications under controlled simulation conditions. Conclusions: rhythmCI bridges a critical gap in circadian bioinformatics by offering a reliable method to characterize periodicity under challenging experimental designs typical of clinical research. By streamlining NanoString workflows and improving the statistical rigor of rhythm detection in small datasets, rhythmCI enhances the accessibility and reliability of circadian biology analysis.

  • Open Access

    Proteome signatures in ICU patients with COVID-19 and acute brain dysfunction: an observational cohort study

    by Andreas Edel, Jayanth Sreekanth, Florian Kurth, Markus Ralser, Vadim Demichev, Michael Mülleder, Eric Blanc, Claudia Spies

    Deep sedation and delirium are common in COVID-19 intensive care unit (ICU) patients. Biomarkers for prediction, detection, and monitoring are missing. Unbiased omics analyses are warranted to gain a systems biology view on pathophysiology. This prospective observational satellite study analysed the proteome signatures of COVID-19 ICU patients with and without acute brain dysfunction (ABD). Conducted in university hospital ICUs between March 2020 and September 2021, patients of legal age with a positive SARS-CoV-2 test were screened daily for deep sedation and delirium. Blood samples were taken thrice weekly. In total, 457 samples were analysed using data-independent acquisition mass spectrometry to determine protein levels. A mixed-effects regression model was developed to identify proteins significantly influenced by ABD, accounting for sex, age and illness severity as confounders. This model also aimed to determine proteins that were either up- or downregulated in association with ABD. Additionally, an enrichment analysis was conducted to examine the biological pathways linked to these ABD-associated proteins. Among 360 patients, 69 were analysed for protein profiling; 42 (60.9%) had ABD at ICU admission [deep sedation: (33; 47,8%); delirium (9; 13%)]. Of 204 proteins, deep sedation markedly shaped the proteomic profile, with 23 proteins uniquely distinguishing it from delirium and no ABD, and 21 proteins were shared across both ABD states. Four proteins (SERPINF1, C1QB, C1QC, PPBP) were specific to delirium, while three (GSN, C1S, PON1) differed across all groups. APOC3 displayed a distinct gradient, highest in delirium and lowest in deep sedation. Pathways involved coagulation, immune response, and lipid metabolism: deep sedation was characterized by complement and coagulation signatures, whereas delirium was also linked to lipid-related processes. The enrichment pathway analysis revealed “Network map of SARS-CoV-2 signalling” (M42569/WP5115) in deep sedation, and “Homeostatic process” (M17351) in delirium. We identified proteomic signatures in COVID-19 ICU patients with ABD, including up- and downregulated proteins. These findings may provide potential biomarker candidates for the assessment of ABD risk and its underlying causes. They could represent a further step towards the development of personalized, causative treatments for delirium and its monitoring in the ICU. Trial registration: The study was retrospectively registered in the German Clinical Trials Register (DRKS00021688 May 13, 2020).

  • Open Access

    Personalised energy targeting during venovenous ECMO: serial assessment of resting energy expenditure reveals phase-dependent metabolic demand and systematic discordance with predictive equations

    by Sarah K. Wilke, Niklas Behnel, Steffen Weber-Carstens, Andreas Edel, Michael Müller, Arne Mahlau, Robert Falk, Martin Ruß, Tobias Wollersheim

    Background: In patients receiving extracorporeal membrane oxygenation (ECMO), metabolic demand varies dynamically across the disease course, while conventional indirect calorimetry in ECMO patients underestimates measured energy expenditure (measured EE) because a substantial proportion of gas exchange occurs across the membrane lung. Specialised protocols can overcome this limitation and measure EE directly during ECMO. However, no adult study has yet compared serial measured EE measurements with concurrent energy intake to assess feeding equipoise or to quantify the temporal variability that personalised nutrition must address. Methods: Post-hoc analysis of prospectively collected data from 9 adult patients receiving venovenous ECMO for acute respiratory distress syndrome at Charité — Universitätsmedizin Berlin. Measured-EE was assessed using the MEEP protocol (75 valid measurements). Feeding equipoise was assessed as the ratio of actual energy intake to measured EE (equipoise: 80–110%). Discordance analysis compared measurement-based classification with hypothetical ESPEN-guided nutrition (25 kcal/kg/day) using adjusted body weight (primary) and actual body weight (sensitivity analysis). Results: Median measured EE was 1923 kcal/day (interquartile range, 1594–2222). The ECMO circuit accounted for 60.5% ± 18.2% of total gas exchange. Feeding equipoise was achieved on only 30 of 75 measurement days (40%); patients were overfed on 44% and underfed on 16%. ESPEN 25 kcal/kg/day with adjusted body weight misclassified feeding equipoise on 55% of days (concordance 45%); actual body weight yielded concordance of 49%. The respiratory quotient (0.908 ± 0.131) did not correlate with the feeding ratio (ρ = 0.024). Conclusion: Both actual feeding practice and standard predictive equations failed to match measured energy requirements regardless of body weight choice. The substantial intra-individual measured EE variability and the progressive decline in extracorporeal gas exchange contribution support a phase-specific, personalised approach guided by serial assessment of measured EE rather than static weight-based targets.

  • Open Access

    The impact of an intensive care telemedicine program on weaning from invasive ventilation: a secondary analysis of the ERIC trial

    by Moritz F. Adam, Julius J. Grunow, Andreas Edel, Karin Steinecke, Friederike S. Schuster, Claudia D. Spies, Björn Weiss, Nicolas Paul

    Background: ICU patients commonly require invasive mechanical ventilation. Although weaning from ventilation is crucial for patient outcomes, it is commonly not performed according to guideline recommendations. We investigated if a complex telemedicine intervention improves the weaning process and outcomes. Methods: This is a secondary analysis of the stepped-wedge cluster-randomized controlled Enhanced Recovery after Intensive Care (ERIC) trial, which was conducted among ten clusters of ICUs in the metropolitan area of Berlin, Germany. ERIC examined the impact of a complex telemedicine intervention, which included daily telemedicine rounding by an intensivist and ICU nurse, on the adherence to eight quality indicators of ICU care. We analyzed patients who received invasive mechanical ventilation for at least two consecutive days and at least one spontaneous breathing trial (SBT). We investigated the impact of the intervention on the weaning process and weaning outcomes using descriptive statistics and mixed-effects regressions. Results: Of 1,463 patients enrolled in the trial, 308 patients were analyzed (control condition: 55; intervention condition: 253). Patients in the intervention group received significantly more SBTs than patients in the control group (51% vs 27% of the patient days; p < 0.001). There was no difference between the groups with respect to the weaning classification ( p = 0.21), weaning success rate (28% vs 36%; p = 0.32), and time from the first SBT to successful weaning (2 [IQR 1, 5] vs 4 [IQR 1, 13] days; p = 0.12). The median time of invasive mechanical ventilation of successfully weaned patients was significantly shorter in the intervention than in the control group (7 [IQR 4, 10] vs 9 [IQR 6, 20] days; p = 0.031). In our multivariable regressions, the intervention was not associated with weaning success (OR for weaning failure: 1.45 [95%-CI 0.71–2.95]; p = 0.302), but with a shorter time between the first SBT and successful weaning (β = 0.56 [0.32–0.98]; p = 0.042). Conclusions: Although ICU telemedicine did not improve the weaning success rate, our findings indicate that it facilitates the exploitation of existing weaning potential by ensuring more frequent SBTs and thereby shortening ventilation duration of successfully weaned patients. The study is the first to highlight the potential of telemedicine to enhance ICU weaning practices. Registration: www.ClinicalTrials.gov (Identifier: NCT03671447; first submitted on August 22, 2018).

  • Open Access

    Wavelet analysis reveals non-stationary cardiovascular rhythms associated with delirium and deep sedation in ICU patients

    by Jayanth Sreekanth, Eduardo Salgado-Baez, Andreas Edel, Elias Gruenewald, Sophie K. Piper, Claudia Spies, Felix Balzer, Sebastian Daniel Boie

    Routine ICU data offers valuable insights into daily physiological rhythms. While traditional methods assume these cycles maintain fixed periods and amplitudes, their inherent variability requires dynamic estimation of instantaneous trends. Wavelet transform effectively resolves circadian oscillations, especially for frequently measured vital parameters. We present novel extensions to the Continuous Wavelet Transform (CWT) power spectral analysis to better detect and segment subtle temporal patterns. Using this approach, we uncover hidden circadian patterns in cardiovascular vitals such as Heart Rate (HR) and Mean Blood Pressure (MBP) measured over five days in a retrospective cohort of 855 ICU patients. By quantifying non-stationary rhythms, we identified diurnal and semi-diurnal oscillations varying in period and power according to delirium and deep sedation. Notably, HR exhibits a clear diurnal and semi-diurnal rhythm when delirium is absent. Overall, our framework supports the CWT as a powerful tool for analyzing complex physiological signals, particularly vital signs. Crucially, our findings suggest that cardiovascular rhythm disruption can be associated with ICU-related delirium and deep sedation.


  • Open Access

    Perspectives of nurses in outpatient intensive care facilities in Germany: A qualitative study

    by Susanne Jöbges, Maike Lucia Lyall, Henning Krampe, Claudia Denke, Clemens Hoffmann, Andreas Edel, Claudia Spies, Anna Balestra

  • Open Access

    Variability in Automated Sepsis Case Detection: A Systematic Analysis of Implementation Methods in Clinical Data Repositories

    by Falk Meyer-Eschenbach, René Schmiedler, Johannes V. Stoephasius, Camille Zhang, Luis Kronfli, Nicolas Frey, Anatol-Fiete Näher, Jacques Ehret, Johanna Nothacker, Christof von Kalle, et al.

    Objective: To systematically review and characterize methodological heterogeneity in sepsis case detection using the MIMIC-III and eICU-CRD databases. Materials and Methods: We conducted a PRISMA-guided systematic review of PubMed and Web of Science (publication years 2016–2024). We extracted methodological details on sepsis case detection across six domains: parameter coverage, temporal windows, aggregation methods, missing-data handling, SOFA calculation, and infection detection methods. For studies with available source code, we additionally examined code structure and repository dependencies to identify methodological decisions across these domains. Results: Of 396 publications screened, 64 met the inclusion criteria and 12 provided available source code. Sepsis detection rates ranged from 3.4% to 65.2% in MIMIC-III and from 9.8% to 47.9% in eICU-CRD. Substantial variability persisted among studies using identical cohort definitions within both databases (MIMIC-III: 16.9%–42.2%; eICU-CRD: 13.9%–31.4%). The overall proportion of studies reporting methodological details varied by domain: SOFA calculation (53.1%), infection detection methods (42.2%), temporal windows (37.5%), aggregation methods (26.6%) and missing-data handling (17.2%). Source code analysis identified 321 implementation decisions, revealing heterogeneity in baseline SOFA definitions (SOFA=0 vs dynamic baseline), temporal windows (infection-centered vs ICU-admission-centered) and infection detection methods (antibiotic-culture matching vs APACHE-based diagnosis). Dependencies among several MIMIC-III repositories suggested propagation of implementation decisions across studies. Discussion: Clinically validated sepsis definitions yield substantially different detection rates across studies using identical datasets, indicating heterogeneity in computational implementation. Conclusion: To improve reproducibility in sepsis research and the robustness of sepsis prediction models, we recommend standardized reporting of sepsis case detection methodology and the publication of version-controlled source code.