XCXiaoping Chen

Xiaoping Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiaoping Chen has a total of 42 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Electrochemically Driven Luminescence without Liquid Electrolyte: A Sensing Platform via Eutectic Gallium−Indium Solid-State Junctions

    by Shi Huang, Zhiping Song, Weiqiang Yang, Jiancong Ni, Zhenyu Lin, Christian A. Nijhuis, Xiaoping Chen

    Electrochemiluminescence (ECL) is a powerful sensing technique but typically relies on liquid electrolytes and multi-electrode configurations, limiting device miniaturization and integration. Here, we report a solid-state electrochemically driven luminescent sensing platform based on two-electrode junctions comprising an indium tin oxide bottom electrode, a Ru(bpy)32+−TPrA@Nafion active layer (TPrA: tripropylamine), and a soft eutectic gallium−indium (EGaIn) top electrode. Nafion serves as a porous host matrix that immobilizes the luminophore and co-reactant while facilitating analyte uptake, whereas EGaIn provides a simple conformal electrical contact for solid-state operation. Despite the absence of a liquid electrolyte during electrical excitation, the junctions retain key characteristics of classical Ru(bpy)32+ electrochemistry. The luminescence is enhanced by the co-reactant TPrA and quenched by dopamine (DA), enabling quantitative sensing based on modulation of the emission intensity. The platform exhibits a linear response to dopamine over a concentration range of 1.0 × 10−10−1.0 × 10−4 M with a detection limit of 5.1 × 10−11 M, together with excellent reproducibility, selectivity, operational stability, and satisfactory recovery in human serum samples. These results demonstrate that ECL-inspired sensing chemistry can be implemented in a solid-state device architecture, providing a promising strategy for integrated luminescent sensing platforms and miniaturized analytical devices.

  • An i-Motif Conformational Transition Synergizing with pH-Responsive Reduced Graphene Oxide Field-Effect Transistor for Urease Activity Sensing

    by Huan Ju, Xiangna Ni, Yanqi Tan, Zhiping Song, Xiaoping Chen, Jiancong Ni, Zhenyu Lin, Weiqiang Yang

    Urease serves as a key diagnostic biomarker, whose abnormal activity is closely associated with oral diseases such as caries and periodontitis. However, detecting trace urease in saliva remains technically challenging. In this work, we report for the first time a C4-rGO-FET biosensor by integrating a conformation-switchable C4-DNA probe with an electrochemically reduced graphene oxide field-effect transistor. The sensing mechanism relies on the pH-induced conformational transition of C4-DNA between a folded i-motif and an unfolded state, which effectively modulates the interfacial charge and thus the carrier distribution in the rGO channel, resulting in a measurable shift in the Dirac point voltage (VCNP). The designed sensor exhibits significantly enhanced pH response (51.57 mV/pH) and reduces the Debye shielding effect. Upon urease-catalyzed hydrolysis of urea, the resulting local pH increase triggers a positive VCNP shift, enabling highly sensitive detection of urease activity. The biosensor demonstrates a wide linear range (1–500 U/L), a low detection limit (0.18 U/L), and good reproducibility. Moreover, it performs reliably in spiked human saliva samples, highlighting its strong potential for point-of-care testing and real-time monitoring in clinical diagnostics.

  • Parallel Bipolar Electrode Array Modified by Hetero-Charged Silica Nanochannels for Ratiometric Electrochemiluminescence Detection of Escherichia coli Lysed by T4 Phage

    by Weiqiang Yang, Qiaoling Fang, Huan Ju, Yanqi Tan, Zhiping Song, Xiaoping Chen, Jiancong Ni, Zhenyu Lin

    Development of user-friendly biosensors for bacterial detection remains a critical concern in public health. The bipolar electrode-based electrochemiluminescence (BPE-ECL) systems are distinguished by their inherent spatial separation of sensing and reporting functions, representing a promising approach for biosensor development. This work innovatively presents a parallel BPE-ECL biosensor, wherein the cathodes are interdigitally inserted and the anodes are functionalized with vertically ordered mesoporous silica films (VMSFs) bearing negative and positive charges, to achieve dual-channel ratiometric ECL detection. The infection of Escherichia coli (E. coli) by T4 phage induces host cell lysis, resulting in a significant increase in the surrounding conductivity. This conductivity alteration within the sensing cell of VMSFs/pBPE-ECL leads to a decrease in the ECL signal of Ru(bpy)32+/TPrA in detection channel 1 and an increase in the ECL signal of Luminol/H2O2 in detection channel 2 independently, due to the enhanced polarization of the BPEs and the nanoconfinement effects of hetero-charged silica nanochannels on the ECL luminophors. By using the ratio of ECL intensities (ILu/IRu) from the two detection channels, E. coli can be detected with improved accuracy and resistance to interference. This biosensing approach is operationally straightforward, avoiding complicated probe immobilization or modification, rendering it a user-friendly platform for bacterial detection. Moreover, by replacing the specific phage-bacteria lysis bioreaction, this biosensing platform could be used for various bacterial detections, highlighting its promising applications.


  • Charge transport of phosphonate self-assembled monolayers across large-area molecular junctions

    by Shi Huang, Qianqian Guo, Jiancong Ni, Zhenyu Lin, Xiaoping Chen

    Molecular junctions consisting of ITO bottom electrode, PO 3 (CH 2 ) n H monolayer, and EGaIn top electrode were fabricated and electrically characterized, exhibiting a tunneling decay coefficient of ∼0.90 n −1 and dielectric constant values of 2.28–2.60.

  • Exploring Tunneling Decay Coefficient of Self-Assembled Monolayers of Alkanethiolates via Electrochemical Impedance Spectroscopy

    by Ning Liu, Yusen Wang, Zhiping Song, Weiqiang Yang, Jiancong Ni, Xiaoping Chen, Zhenyu Lin

    Understanding the charge transfer and dielectric properties of organic monolayers in electrochemical systems is still challenging because these two properties are intertwined by variables including monolayer structure, electrolyte type, and concentration. The tunneling decay coefficient (β) reflects the evolution of molecular resistance vs length in a circuit. In this work, we applied electrochemical impedance spectroscopy (EIS) to characterize self-assembled monolayers (SAMs) of S(CH2)n-1CH3 (nC = 4, 6, 8, 10, and 12) on Au electrodes in both redox Fe(CN)63-/4- and nonredox NaClO4 electrolytes. We found that decreasing the concentration of Fe(CN)63-/4- (CFe) from 100 to 1.0 mM led to increases in solution resistance (RS) from ∼3.3 to 17.0 Ω·cm2, log-resistance of SAM from 1.62 to 5.04 Ω·cm2 for nC = 12, and a 63% increase in β from 0.51 to 0.83 nC-1; the dielectric constant of the SAM (εr) decreased with nC while remaining almost constant at different CFe. EIS in the nonredox NaClO4 electrolyte showed a low β value of 0.62 nC-1. Low CFe of 1.0-10 mM was optimal for precise electrochemical characterizations of short and compact SAMs with a 2.5 Å variation in molecular thickness. Our study contributes to a better understanding of how the electrolyte and monolayer-modified barrier affect the charge transfer across SAM-electrode interfaces and the dielectric response of SAM, in electrochemical and biological sensing applications.

  • Bimetallic-Doped Metal–Organic Gel for Efficient Electrochemiluminescence: Staircase-Mediated Energy Transfer and Applications in Epinephrine Detection

    by Jiancong Ni, Ya Xiong, Guiyun Zhang, Xiaoping Chen, Zhenyu Lin, Weiqiang Yang

    This study presents the development of a novel bimetallic-doped metal-organic gel (Tb-Eu-MOG) synthesized by codoping terbium (Tb(III)) and europium (Eu(III)) with the Hcptpy ligand and explores its application in electrochemiluminescence (ECL) for sensitive detection of epinephrine (EP). The Tb-Eu-MOG exhibits unique petal nanoflower-like morphology and remarkable ECL signals, attributed to the dual sensitization effects of Tb(III) and Eu(III) on the Hcptpy ligand. The Tb(III) doping facilitates energy transfer and enhances ECL efficiency through a staircase effect. The Tb-Eu-MOG/K2S2O8 system demonstrates a high ECL intensity, which is significantly quenched in the presence of EP due to its competitive consumption of SO4•- radicals. The ECL intensity shows a linear correlation with the logarithmic concentration of EP in the range of 1.0 × 10-10 to 1.0 × 10-3 M, with a detection limit as low as 48 pM. This work not only expands the potential applications of bimetallic MOGs in the ECL field but also provides insights into the relationship between the central metal ion and the ligand, which is crucial for ECL detection. The alignment of orbital energy levels between the central metal ion and the ligand is identified as a significant mechanism for enhancing ECL. This research offers a promising strategy for the design of highly efficient ECL luminophores and broadens the scope of sensing applications.


  • Indicator-Free Detection of Hyaluronidase Based on a Conductivity-Regulated Bipolar Electrochemiluminescence Platform

    by Jiancong Ni, Xiaochun Xu, Bifang Yang, Liyang Liu, Weiqiang Yang, Xiaoping Chen, Guiping Chen, Qingxiang Wang, Zhenyu Lin

    Hyaluronidase (HAase) detection plays a critical role in cancer diagnosis and treatment. Most HAase biosensors require the incorporation of exogenous indicators into the sensing reaction for signal transduction, which might involve complex synthesis and modification procedures or potentially interfere with enzymatic activity. Herein, based on the fact that the electrochemiluminescence (ECL) can be regulated via a bipolar electrode (BPE) through the alteration of conductivity in the enzymatic reaction solution, we develop an indicator-free HAase biosensor based on the bipolar-based ECL (BP-ECL) platform. HAase degrades negatively charged macromolecular hyaluronic acid (HA) into small anionic fragments, thereby increasing the conductivity of the sensing solution. As a result, the variation of conductivity adjusts the voltage drop across the BPE and promotes electron transfer reactions at the anodic pole, thereby enhancing the ECL emission in the reporting cell. The HAase activity can be quantified by monitoring the ECL response modulation in the BP-ECL sensing platform. Given the optimal experimental conditions, the proposed BP-ECL biosensor showed a good linear relationship with the concentration of HAase in the range of 1∼60 U/mL and a detection limit of 0.13 U/mL. The developed HAase biosensor eliminates the need for exogenous indicators in bioreaction solutions and has been successfully applied for target detection in real samples with satisfactory performance.


  • Open Access

    Influence of anchoring group on charge transport across self-assembled monolayer-based molecular tunnel junctions

    by Qianqian Guo, Shi Huang, Xiaojiang Yu, Christian Albertus Nijhuis, Xiaoping Chen

    Predicting the charge transport rate, mechanism and the dielectric response of solid-state molecular electronics is challenging since these properties depend on many variables such as molecular backbone, electrode material, junction contact geometry, anchoring and terminal functional groups, and so on. Although the effects of anchoring group (X) on the conductance of single-molecule junctions have been widely investigated, in large-area junctions examples are rare although the latter makes it possible to also explore the role of dielectric properties on charge transport rates. Here we report a change of 2.5 orders of magnitude in the charge transport rate along with a factor of 3 change in the measured dielectric constant (ɛr) across monolayers of X(C6H4)nH with n=1 or 2 and X=-NO2, -SH, -NH2, -CN, and -Pyr. Our combined study involving current-voltage measurements and impedance spectroscopy allowed us to isolate the contact (RC) and monolayer resistance (RSAM), and found that the RC increased with the X order. This change in RC goes hand-in-hand with the shift of HOMO and LUMO energy levels with respect to the Fermi levels of the electrodes explaining the large observed change in charge transport rates. Surprisingly, the increase in tunneling rates (or decrease in RSAM) scales with ɛr. Our work provides new insights into the factors that influence the charge transport rates and dielectric responses of molecular junctions besides widely studied changes to the molecular backbone or terminal functional groups.


  • Open Access

    Supramolecular tunnelling junctions with robust high rectification based on assembly effects

    by Max Roemer, Xiaoping Chen, Yuan Li, Le-Jia Wang, Xiaojiang Yu, Pierre-André Cazade, Cameron Nickle, Romena Akter, Enrique Del Barco, Damien Thompson, et al.

    The performance of large-area molecular diodes can in rare cases approach the lower limit of commercial semiconductor devices but predictive structure–property design remains difficult as the rectification ratio (R) achieved by self-assembled monolayer (SAM) based diodes depends on several intertwined parameters. This paper describes a systematic approach to achieve high rectification in bisferrocenyl-based molecular diodes, HSCnFc–C≡C–Fc (n = 9-15) immobilised on metal surfaces (Ag, Au and Pt). Experiments supported by molecular dynamics simulations show that the molecular length and bottom electrode influence the SAM packing, which affects the breakdown voltage (VBD), the associated maximum R (Rmax), and the bias at which the Rmax is achieved (Vsat,R). From the electrical characterisation of the most stable Pt–SCnFc–C≡C–Fc//GaOx/EGaIn junctions, we found that VBD, Vsat,R, and Rmax all scale linearly with spacer length of Cn, and that Rmax for all the SAMs consistently exceeds the “Landauer limit” of 103. Our data shows that the robust switching of M–SCnFc–C≡C–Fc//GaOx/EGaIn junctions are the result of the combined optimisation of parameters involving the molecular structure, the type of metal substrate, and the applied operating conditions (bias window), to create stable and high-performance junctions.