Shupeng Su
Shupeng Su has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Huiqin Zhao
Hebei Hongshan National Observatory on Thick Sediments and Seismic Hazards, Xingtai, China
3 shared publicationsShuanggui Chen
Gansu Lanzhou Geophysics National Observation and Research Station, Lanzhou, China
2 shared publicationsBo Li
Baoding Central Seismic Station of Hebei Province, Baoding, China
1 shared publicationDe-Qiang Liu
Hebei Hongshan National Observatory on Thick Sediments and Seismic Hazards, Xingtai, China
1 shared publicationDeqiang Liu
Baoding Central Seismic Station of Hebei Province
1 shared publicationFeng-Long Mao
Hebei Hongshan National Observatory on Thick Sediments and Seismic Hazards, Xingtai, China
1 shared publication
Latest Publications
- 1 September 2023
- Published by Springer Nature in Applied Geophysics
- Vol. 20 (3) , 324-333
Correction method for secular variation in the main geomagnetic field using a field seismogeomagnetic survey
- 1 September 2023
- Published by Springer Nature in Applied Geophysics
- Vol. 20 (3) , 324-333
Correction method for secular variation in the main geomagnetic field using a field seismogeomagnetic survey
- 22 August 2023
- Published by Pleiades Publishing Ltd in Journal of Volcanology and Seismology
- Vol. 17 (4) , 338-351
Observation and Research of Field Seismomagnetic Monitoring Experimental Areas in the Capital Region of China
To explore an efficient approach refining seismomagnetic information through magnetic field survey technology, the author introduces the seismomagnetic monitoring system of the capital region in China. It includes field measurement techniques, data processing methods and application performance. The variation characteristics of the crustal magnetic field and seismomagnetic information in this area are systematically calculated and statistically analyzed based on the geomagnetic data products of the X, Y, and Z components. The results show that the mean amplitudes of X, Y and Z of the crustal magnetic field in the study area are 1.87, 1.90, and 1.39 nT, and the mean square deviations are 2.41, 2.48, and 1.94 nT, respectively. The epicenters of future large earthquakes will mostly lie near the “0” value line of crustal magnetic field variation with very low amplitude, which X, Y and Z elements are 18.7, 45.5 and 53.9% of the mean values in the survey area, respectively, and rise obviously after the earthquake. There is a high correlation between the location of the epicenter and the anomalous region of low spatial variation ratio of geomagnetic field secular variation.
- 22 August 2023
- Published by Pleiades Publishing Ltd in Journal of Volcanology and Seismology
- Vol. 17 (4) , 338-351
Observation and Research of Field Seismomagnetic Monitoring Experimental Areas in the Capital Region of China
To explore an efficient approach refining seismomagnetic information through magnetic field survey technology, the author introduces the seismomagnetic monitoring system of the capital region in China. It includes field measurement techniques, data processing methods and application performance. The variation characteristics of the crustal magnetic field and seismomagnetic information in this area are systematically calculated and statistically analyzed based on the geomagnetic data products of the X, Y, and Z components. The results show that the mean amplitudes of X, Y and Z of the crustal magnetic field in the study area are 1.87, 1.90, and 1.39 nT, and the mean square deviations are 2.41, 2.48, and 1.94 nT, respectively. The epicenters of future large earthquakes will mostly lie near the “0” value line of crustal magnetic field variation with very low amplitude, which X, Y and Z elements are 18.7, 45.5 and 53.9% of the mean values in the survey area, respectively, and rise obviously after the earthquake. There is a high correlation between the location of the epicenter and the anomalous region of low spatial variation ratio of geomagnetic field secular variation.
- 14 December 2022
- Published by Pleiades Publishing Ltd in Izvestiya, Physics of the Solid Earth
- Vol. 58 (6) , 981-991
Taylor Polynomial Spatial Reference Field Method for Field Geomagnetic Diurnal Variation Reduction
This study addresses the problems and shortcomings of the traditional field geomagnetic diurnal variation reduction method, the single-observatory reference method, by applying the Taylor polynomial model to establish a spatial reference field for diurnal variation reduction based on geomagnetic network data and comparing the results of the two methods. The findings are as follows: 1. The Taylor polynomial spatial reference field method can effectively describe the spatial distribution pattern of the geomagnetic field, and its results are more accurate and reliable than those of the single-observatory reference method. 2. The results obtained by the proposed method are more uniform and stable than those obtained by the single-observatory reference method, and they are closer to the theoretical shape of Earth’s crustal magnetic field changes. 3. While applying the proposed method on earthquakes, it optimizes the display of seismomagnetic information and has good application values.
- 14 December 2022
- Published by Pleiades Publishing Ltd in Izvestiya, Physics of the Solid Earth
- Vol. 58 (6) , 981-991
Taylor Polynomial Spatial Reference Field Method for Field Geomagnetic Diurnal Variation Reduction
This study addresses the problems and shortcomings of the traditional field geomagnetic diurnal variation reduction method, the single-observatory reference method, by applying the Taylor polynomial model to establish a spatial reference field for diurnal variation reduction based on geomagnetic network data and comparing the results of the two methods. The findings are as follows: 1. The Taylor polynomial spatial reference field method can effectively describe the spatial distribution pattern of the geomagnetic field, and its results are more accurate and reliable than those of the single-observatory reference method. 2. The results obtained by the proposed method are more uniform and stable than those obtained by the single-observatory reference method, and they are closer to the theoretical shape of Earth’s crustal magnetic field changes. 3. While applying the proposed method on earthquakes, it optimizes the display of seismomagnetic information and has good application values.
- 1 December 2022
- Published by Springer Nature in Applied Geophysics
- Vol. 19 (4) , 580-589
Longitude correction method for the field magnetic surveyed diurnal-variation correction
- 1 December 2022
- Published by Springer Nature in Applied Geophysics
- Vol. 19 (4) , 580-589
Longitude correction method for the field magnetic surveyed diurnal-variation correction
- 28 September 2022
- Published by Pleiades Publishing Ltd in Geomagnetism and Aeronomy
- Vol. 62 (5) , 657-662
Moving Superposition Method for Sq Extraction and the Effectiveness Evaluation
The superposed epoch analysis (SEA) method is a traditional extraction method for the solar quiet daily variation (Sq) and obtains the monthly Sq by the averages of the data on the international five quietest days (five Q-days) in one month. This study tried to optimize this method through two technical measures, increasing the number of calculation days and moving the calculation period day by day. To test the effectiveness of the new method, the observatory data were decomposed into Sq components and non-Sq components by the characteristic of Sq varying with local time (LT). The observatory data were reconstructed by correcting the Sq components for time differences. Then, the two Sq extraction methods were evaluated based on the correlation coefficient and mean square error (MSE) of the difference between the reconstructed data and the reference observatory data. Comparison with the traditional method showed that the correlation coefficients for the three factors H, D, and Z were improved by 0.0142, 0.0017, and 0.0235, and MSEs were improved by 0.24 nT, 0.03´, and 0.17 nT, respectively, indicating that the Sq results are more reasonable.
- 28 September 2022
- Published by Pleiades Publishing Ltd in Geomagnetism and Aeronomy
- Vol. 62 (5) , 657-662
Moving Superposition Method for Sq Extraction and the Effectiveness Evaluation
The superposed epoch analysis (SEA) method is a traditional extraction method for the solar quiet daily variation (Sq) and obtains the monthly Sq by the averages of the data on the international five quietest days (five Q-days) in one month. This study tried to optimize this method through two technical measures, increasing the number of calculation days and moving the calculation period day by day. To test the effectiveness of the new method, the observatory data were decomposed into Sq components and non-Sq components by the characteristic of Sq varying with local time (LT). The observatory data were reconstructed by correcting the Sq components for time differences. Then, the two Sq extraction methods were evaluated based on the correlation coefficient and mean square error (MSE) of the difference between the reconstructed data and the reference observatory data. Comparison with the traditional method showed that the correlation coefficients for the three factors H, D, and Z were improved by 0.0142, 0.0017, and 0.0235, and MSEs were improved by 0.24 nT, 0.03´, and 0.17 nT, respectively, indicating that the Sq results are more reasonable.
- Open Access
- 19 January 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (3) , 1005
Characteristics of Local Geomagnetic Field Variations and the Tectonic Stress Field Adjacent to the 21 May 2021, Ms 6.4 Yangbi Earthquake, Yunnan, China
The tectonic processes leading up to an earthquake and the occurrence of the earthquake itself will cause local changes in the geophysical field (geomagnetic field, stress field, etc.). In this paper, the variation characteristics of the tectonic stress field (TSF) and local geomagnetic field (LGF) before and after the Yangbi Ms 6.4 earthquake are studied. The regional stress tensor damping inversion method was used to invert the TSF using focal mechanism solutions (FMSs). The change characteristics of the TSF before and after the earthquake were analyzed. An annual variation model of the LGF was constructed, and the variation of the horizontal vector was analyzed. The azimuth and plunge of the maximum principal compressive stress axis of the TSF in the epicentral region before and after the earthquake were −4.4° and 2.7°, 172.7° and 6.6°, respectively. The variations in the declination, inclination and total intensity of the epicenter one year before and one month after the earthquake were −0.20′ (0.07′), 0.29′ (−0.12′), and −1.7 nT (−1.9 nT), respectively. The epicenter is located at the boundary of the “weak variation region” of the horizontal vector. This research is of great significance concerning the TSF background and incubation mechanism of earthquakes.
- 19 January 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (3) , 1005
Open AccessCharacteristics of Local Geomagnetic Field Variations and the Tectonic Stress Field Adjacent to the 21 May 2021, Ms 6.4 Yangbi Earthquake, Yunnan, China
The tectonic processes leading up to an earthquake and the occurrence of the earthquake itself will cause local changes in the geophysical field (geomagnetic field, stress field, etc.). In this paper, the variation characteristics of the tectonic stress field (TSF) and local geomagnetic field (LGF) before and after the Yangbi Ms 6.4 earthquake are studied. The regional stress tensor damping inversion method was used to invert the TSF using focal mechanism solutions (FMSs). The change characteristics of the TSF before and after the earthquake were analyzed. An annual variation model of the LGF was constructed, and the variation of the horizontal vector was analyzed. The azimuth and plunge of the maximum principal compressive stress axis of the TSF in the epicentral region before and after the earthquake were −4.4° and 2.7°, 172.7° and 6.6°, respectively. The variations in the declination, inclination and total intensity of the epicenter one year before and one month after the earthquake were −0.20′ (0.07′), 0.29′ (−0.12′), and −1.7 nT (−1.9 nT), respectively. The epicenter is located at the boundary of the “weak variation region” of the horizontal vector. This research is of great significance concerning the TSF background and incubation mechanism of earthquakes.
- Open Access
- 2 August 2021
- Published by Springer Nature in Research Square
Study of the Correction Method of Secular Variation in the Main Geomagnetic Field by the Field Seismogeomagnetic Survey
The correction of the secular variation (SV) of the main geomagnetic field is a key link of field seismogeomagnetic data processing, and the current method relies on the observatory data for the relevant technical processing. To optimize the data products and obtain more accurate and reliable seismomagnetic information, this study adopted a new technical idea, which uses the repeated survey data from field stations to obtain the SV of the main geomagnetic field over the survey area by the weighted least-squares method, and compared the results with those of the current methods. The results were as follows: 1. The SV results of the main geomagnetic field produced by the new method are closer to those of the International Geomagnetic Reference Field (IGRF)_SV model. The mean square error (MSE) of the difference of the three elements F, D, and I between the new method and the IGRF_SV model is 10.7%, 47.0%, and 14.5% of that of the original method, respectively. 2. By applying the new SV correction method, more stable and reasonable variations in Earth’s crustal magnetic field can be obtained. The average amplitude of the Earth’s crustal magnetic field variation in the three elements F, D, and I is 28.5%, 55.4%, and 34.4 of the original results, the MSE is 59.1%, 56.5%, and 40.3% of the original results, and the mean gradient is 93.6%, 91.9%, and 97.0%, respectively. 3. In the processed results of the new method, the seismomagnetic information is clearly optimized, and the location of the epicenter is more consistent with the 0 value line of the Earth’s crustal magnetic field. The processed results of the new method are significantly better than those of the original method and have a higher application value.
- 2 August 2021
- Published by Springer Nature in Research Square
Open AccessStudy of the Correction Method of Secular Variation in the Main Geomagnetic Field by the Field Seismogeomagnetic Survey
The correction of the secular variation (SV) of the main geomagnetic field is a key link of field seismogeomagnetic data processing, and the current method relies on the observatory data for the relevant technical processing. To optimize the data products and obtain more accurate and reliable seismomagnetic information, this study adopted a new technical idea, which uses the repeated survey data from field stations to obtain the SV of the main geomagnetic field over the survey area by the weighted least-squares method, and compared the results with those of the current methods. The results were as follows: 1. The SV results of the main geomagnetic field produced by the new method are closer to those of the International Geomagnetic Reference Field (IGRF)_SV model. The mean square error (MSE) of the difference of the three elements F, D, and I between the new method and the IGRF_SV model is 10.7%, 47.0%, and 14.5% of that of the original method, respectively. 2. By applying the new SV correction method, more stable and reasonable variations in Earth’s crustal magnetic field can be obtained. The average amplitude of the Earth’s crustal magnetic field variation in the three elements F, D, and I is 28.5%, 55.4%, and 34.4 of the original results, the MSE is 59.1%, 56.5%, and 40.3% of the original results, and the mean gradient is 93.6%, 91.9%, and 97.0%, respectively. 3. In the processed results of the new method, the seismomagnetic information is clearly optimized, and the location of the epicenter is more consistent with the 0 value line of the Earth’s crustal magnetic field. The processed results of the new method are significantly better than those of the original method and have a higher application value.