Abdelmalek Khezzar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Abdelmalek Khezzar has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Abdelfettah Boussaid
Université Constantine 1
2 shared publications - A. L. Nemmour
Laboratoire d'Electrotechnique LEC, Université Mentouri, Constantine, Algeria
1 shared publication - A.L. Nemmour
University Fréres Mentouri Constantine 1, Algeria
1 shared publication - Aïssa Rezzoug
College of Engineering, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh 11432, Saudi Arabia
1 shared publication - Fateh Mehazzem
Groupe ESIEE, Paris Est University, France
1 shared publication H. Chemali
Universit Mentouri-Constantine, Laboratoire d'Electrotechnique de Constantine, 25000 Constantine, Algria
1 shared publication
Latest Publications
- Open Access
- 2 July 2026
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 4,p. 40-46
Shunt active power filter with variable leaky least mean squares and multivariable filter phase-locked loop for fast harmonic compensation under non-ideal grid conditions
Introduction. The widespread adoption of power-electronic loads has made harmonic distortion a critical power-quality issue. shunt active power filters (SAPFs) remain the most versatile solution. Problem. The conventional harmonic compensation algorithms suffer from degraded filtering performance under non-ideal grid condition, while the conventional low-pass filters (LPFs) in instantaneous reactive power theory (p-q theory) create an unavoidable trade-off between transient speed and harmonic rejection. Goal. To develop an adaptive and efficient harmonic current compensation algorithm that can generate reference currents with rapid convergence and high accuracy under non-ideal grid conditions. Methodology. The proposed method combines a multivariable filter phase-locked loop (MVF-PLL) for precise extraction of instantaneous components normalized to unit amplitude (i.e., sinq, cosq) with a variable leaky least mean squares (VLLMS) adaptive filter for DC component extraction. The algorithm was tested in MATLAB/Simulink across five scenarios, including balanced and unbalanced voltages, variable loads, and voltage distortions. Experimental validation was conducted on a field-programmable gate array (FPGA) using real-time co-simulation and hardware implementation. Results. MATLAB/Simulink simulations and real-time FPGA implementation on a low-cost Spartan-6 board show that the proposed method reduces the 2–98 % rise time of the extracted DC active power from ≈ 12 ms (4th-order Butterworth LPF) to 0.6– 0.8 ms (93–95 % improvement) while maintaining source current total harmonic distortion below 4.92 % in the worst case fully compliant with IEEE 519. The extremely low computational cost makes the solution ideal for industrial controllers. Scientific novelty. This paper proposes a novel control strategy that replaces the traditional LPF with a single-coefficient VLLMS adaptive filter while ensuring robust positive-sequence synchronisation via an MVF-PLL. Practical value. The algorithm improves SAPF performance, reduces response time, and ensures stable operation across diverse grid scenarios, offering a reliable solution for industrial applications. References 24, tables 2, figures 15.
- 2 July 2026
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 4,p. 40-46
Open AccessShunt active power filter with variable leaky least mean squares and multivariable filter phase-locked loop for fast harmonic compensation under non-ideal grid conditions
Introduction. The widespread adoption of power-electronic loads has made harmonic distortion a critical power-quality issue. shunt active power filters (SAPFs) remain the most versatile solution. Problem. The conventional harmonic compensation algorithms suffer from degraded filtering performance under non-ideal grid condition, while the conventional low-pass filters (LPFs) in instantaneous reactive power theory (p-q theory) create an unavoidable trade-off between transient speed and harmonic rejection. Goal. To develop an adaptive and efficient harmonic current compensation algorithm that can generate reference currents with rapid convergence and high accuracy under non-ideal grid conditions. Methodology. The proposed method combines a multivariable filter phase-locked loop (MVF-PLL) for precise extraction of instantaneous components normalized to unit amplitude (i.e., sinq, cosq) with a variable leaky least mean squares (VLLMS) adaptive filter for DC component extraction. The algorithm was tested in MATLAB/Simulink across five scenarios, including balanced and unbalanced voltages, variable loads, and voltage distortions. Experimental validation was conducted on a field-programmable gate array (FPGA) using real-time co-simulation and hardware implementation. Results. MATLAB/Simulink simulations and real-time FPGA implementation on a low-cost Spartan-6 board show that the proposed method reduces the 2–98 % rise time of the extracted DC active power from ≈ 12 ms (4th-order Butterworth LPF) to 0.6– 0.8 ms (93–95 % improvement) while maintaining source current total harmonic distortion below 4.92 % in the worst case fully compliant with IEEE 519. The extremely low computational cost makes the solution ideal for industrial controllers. Scientific novelty. This paper proposes a novel control strategy that replaces the traditional LPF with a single-coefficient VLLMS adaptive filter while ensuring robust positive-sequence synchronisation via an MVF-PLL. Practical value. The algorithm improves SAPF performance, reduces response time, and ensures stable operation across diverse grid scenarios, offering a reliable solution for industrial applications. References 24, tables 2, figures 15.
- Open Access
- 1 January 2021
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 4,p. 53-63
AN EFFECTIVE CONTROL ALGORITHM FOR DYNAMIC VOLTAGE RESTORER UNDER SYMMETRICAL AND ASYMMETRICAL GRID VOLTAGE CONDITIONS
Introduction. Voltage sag, which is associated to a transitory drop in the root mean square voltage characterizing an electrical source network. During these perturbations, the corresponding electronic customers and devices will suffer from serious operating troubles causing dangerous damages. Purpose. In order to attenuate this disturbance effects, the Controlled Dynamic Voltage Restorer constitutes a very interesting solution among many others that have been proposed. The novelty of the proposed work consists in presenting an enhanced algorithm to control efficiently the dynamic voltage restorer when voltage sag is suddenly occurred. Methods. The proposed algorithm is based on an instantaneous phase locked loop using a multi variable filter to synthesize unitary signals involved in compensation voltages computation relative to the sag apparition. Practical value. A detailed study concerning typical voltage sag, which is consolidated by simulation and experimental results, is conducted to show the used algorithm's effectiveness to cancel the corresponding voltage sag. References 44, table 1, figures 16.
- 1 January 2021
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 4,p. 53-63
Open AccessAN EFFECTIVE CONTROL ALGORITHM FOR DYNAMIC VOLTAGE RESTORER UNDER SYMMETRICAL AND ASYMMETRICAL GRID VOLTAGE CONDITIONS
Introduction. Voltage sag, which is associated to a transitory drop in the root mean square voltage characterizing an electrical source network. During these perturbations, the corresponding electronic customers and devices will suffer from serious operating troubles causing dangerous damages. Purpose. In order to attenuate this disturbance effects, the Controlled Dynamic Voltage Restorer constitutes a very interesting solution among many others that have been proposed. The novelty of the proposed work consists in presenting an enhanced algorithm to control efficiently the dynamic voltage restorer when voltage sag is suddenly occurred. Methods. The proposed algorithm is based on an instantaneous phase locked loop using a multi variable filter to synthesize unitary signals involved in compensation voltages computation relative to the sag apparition. Practical value. A detailed study concerning typical voltage sag, which is consolidated by simulation and experimental results, is conducted to show the used algorithm's effectiveness to cancel the corresponding voltage sag. References 44, table 1, figures 16.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 560-564
Analysis of stator current of dual-three phase induction motor drive under broken bar fault condition
This paper deals with the analysis of the effect of broken bars fault in stator currents spectrums of a dual three phase induction motor drives. The influence of the unbalanced current between to sets resulting from the leakage inductances and phase winding resistances unbalances on the well-known characteristic frequencies of broken bars and the rotor slot harmonic (RSH) is discussed. The results show that the use of (x, y) current controllers allows not only to provide better performance of dual three phase induction motor but also to avoid error in the assess fault severity. Experimental results have been presented to validate the analytical and simulation results.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 560-564
Analysis of stator current of dual-three phase induction motor drive under broken bar fault condition
This paper deals with the analysis of the effect of broken bars fault in stator currents spectrums of a dual three phase induction motor drives. The influence of the unbalanced current between to sets resulting from the leakage inductances and phase winding resistances unbalances on the well-known characteristic frequencies of broken bars and the rotor slot harmonic (RSH) is discussed. The results show that the use of (x, y) current controllers allows not only to provide better performance of dual three phase induction motor but also to avoid error in the assess fault severity. Experimental results have been presented to validate the analytical and simulation results.
- Open Access
- 20 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 61 (6) , 2942
Corrections to “Effects of the Simultaneous Presence of Static Eccentricity and Broken Rotor Bars on the Stator Current of Induction Machine” [May 14 2452-2463]
Due to an unfortunate omission, the above paper (ibid., vol. 61, no. 5, pp. 2452-2463, May 2014), was submitted and published with an incomplete list of authors. The full list of the authors of this paper is Mohamed Yazid Kaikaa, Marouane Hadjami, and Abdelmalek Khezzar. The third author, whose name was omitted from the original paper, is with the Laboratoire d'Electrotechnique de Constantine, Mentouri University of Constantine, 25000 Constantine, Algeria (e-mail: akhezzar@yahoo.fr). The photograph and biography of Prof. Khezzar are presented here.
- 20 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 61 (6) , 2942
Open AccessCorrections to “Effects of the Simultaneous Presence of Static Eccentricity and Broken Rotor Bars on the Stator Current of Induction Machine” [May 14 2452-2463]
Due to an unfortunate omission, the above paper (ibid., vol. 61, no. 5, pp. 2452-2463, May 2014), was submitted and published with an incomplete list of authors. The full list of the authors of this paper is Mohamed Yazid Kaikaa, Marouane Hadjami, and Abdelmalek Khezzar. The third author, whose name was omitted from the original paper, is with the Laboratoire d'Electrotechnique de Constantine, Mentouri University of Constantine, 25000 Constantine, Algeria (e-mail: akhezzar@yahoo.fr). The photograph and biography of Prof. Khezzar are presented here.
- 1 September 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 304-307
Experimental investigation of new indices of broken rotor bar in induction motor
Most of rotor related faults in three-phase induction motors are due to broken rotor bars and end-ring defects. Nowadays Inductions motors are more frequently used with inverters which make the diagnosis process more complicated. Furthermore, some manufacturers of induction machines mount converters (i.e. rectifier and inverter) directly onto the machine, which makes the stator current unattainable for diagnosis. In order to overcome these drawbacks, the authors propose to analyze new motor fault signatures in the supply line current of the inverter. Experimental and simulation results show a total agreement and confirm the effectiveness of the present study.
- 1 September 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 304-307
Experimental investigation of new indices of broken rotor bar in induction motor
Most of rotor related faults in three-phase induction motors are due to broken rotor bars and end-ring defects. Nowadays Inductions motors are more frequently used with inverters which make the diagnosis process more complicated. Furthermore, some manufacturers of induction machines mount converters (i.e. rectifier and inverter) directly onto the machine, which makes the stator current unattainable for diagnosis. In order to overcome these drawbacks, the authors propose to analyze new motor fault signatures in the supply line current of the inverter. Experimental and simulation results show a total agreement and confirm the effectiveness of the present study.
- 21 March 2010
- Published by Elsevier in Renewable Energy
- Vol. 35 (10) , 2375-2380
Advanced Backstepping controller for induction generator using multi-scalar machine model for wind power purposes
- 21 March 2010
- Published by Elsevier in Renewable Energy
- Vol. 35 (10) , 2375-2380