  • Open Access

    Optical principles of high-speed fluorescence lifetime imaging microscopy for flow cytometry

    by Hiroshi Kanno

    Fluorescence lifetime imaging microscopy (FLIM) has emerged as a powerful tool in biology and medicine, as it can circumvent experimental artifacts inherent to conventional fluorescence-intensity-based measurements. However, FLIM has traditionally suffered from limited imaging speed, primarily due to the requirement for time-resolved fluorescence detection. Recently, we developed a high-speed FLIM approach and demonstrated the acquisition of more than 10,000 cell images per second. This review introduces the key optical aspects underlying this high-speed FLIM to a broad readership. Specifically, simultaneous multi-point fluorescence lifetime measurement is achieved by generating and exploiting spatially dispersed, intensity-modulated dual-beam arrays. This unique excitation scheme enables efficient acceleration of FLIM while mitigating frequency-dependent bias arising from multi-component fluorescence lifetimes. The developed high-speed FLIM and FLIM-based flow cytometry are expected to serve as versatile imaging platforms for a wide range of biomedical applications.

  • Open Access

    Single-pixel imaging flow cytometry for biomedical research

    by Hiroshi Kanno, Zhiying Liu, Rio Sato, Hidenori Endo, Kuniyasu Niizuma, Keisuke Goda

    High-throughput single-cell analysis and screening have become essential tools in life science research. Imaging flow cytometry, in particular, enables large-scale image-based profiling of heterogeneous cell populations, allowing statistical analysis of cellular morphology, subcellular features, and functional responses. However, its analytical capability is often limited by the use of conventional two-dimensional (2D) image sensors. In this review, we highlight recent advances in single-pixel imaging flow cytometry, which replaces 2D image sensors with single-pixel photodetectors. This approach offers advantages in sensitivity, flexibility, and speed in imaging system design and has been implemented in various optical configurations to achieve high-throughput single-cell imaging. We first introduce its key techniques, then outline representative biomedical applications, including cancer and COVID-19 research, and finally discuss current limitations and prospects for future developments. Single-pixel imaging flow cytometry is expected to serve as a versatile platform supporting both basic and translational studies in diverse biomedical applications.


  • Open Access

    High-speed fluorescence lifetime imaging microscopy: techniques, applications, and prospects

    by Hiroshi Kanno, Fan Li, Jongchan Park, Hidenori Endo, Kuniyasu Niizuma, Liang Gao, Keisuke Goda

    Fluorescence lifetime imaging microscopy (FLIM) has been gaining increasing attention due to its capability to provide robust, accurate, and quantitative measurements, surpassing conventional intensity-based fluorescence microscopy.1 – 3 Unlike fluorescence intensity, which is influenced by factors such as fluorophore concentration, photobleaching, and excitation laser intensity, fluorescence lifetime remains largely independent of these variables, ensuring precise and reproducible imaging under varying experimental conditions.1,4 Moreover, fluorescence lifetime is highly sensitive to the microenvironment of fluorescent molecules, particularly when their structural properties are inherently dynamic or chemically engineered to respond to specific stimuli.1,4 For example, FliptR,5 commercially known as Flipper-TR,6 undergoes conformational changes in response to cell membrane tension, allowing the measurement of this parameter through changes in fluorescence lifetime. This unique capability enables FLIM to correlate fluorescence lifetime with key physiological factors such as pH,7,8 temperature,9,10 viscosity,11 – 13 ion concentrations,14,15 and metabolic states,16 – 18 facilitating in-depth studies of both intracellular and extracellular environments with high spatial resolution. Furthermore, fluorescence lifetime can serve as an additional dimension for distinguishing fluorescent molecules with overlapping emission spectra, thus enabling advanced multi-color imaging.19 – 21 These features make FLIM a powerful and reliable imaging tool across a wide range of fields, including cell biology, biophysics, and neurology.22


  • Open Access

    Direct evaluation of antiplatelet therapy in coronary artery disease by comprehensive image-based profiling of circulating platelets

    by Kazutoshi Hirose, Satoshi Kodera, Masako Nishikawa, Masataka Sato, Yuqi Zhou, Hongqian Zhang, Shun Minatsuki, Junichi Ishida, Norifumi Takeda, Huidong Wang, et al.

    Coronary artery disease (CAD) is a leading cause of death globally. Antiplatelet therapy remains crucial in preventing and treating CAD-associated thrombotic complications, but it concurrently amplifies the risk of bleeding. Unfortunately, traditional platelet function measurement methods cannot directly evaluate its efficacy and safety. Here we demonstrate comprehensive image-based profiling of circulating platelets to directly observe thrombotic conditions and assess antiplatelet therapy in CAD patients. Deep learning-based analysis of whole blood samples from 207 CAD patients revealed elevated concentrations of circulating platelet aggregates, especially in acute versus chronic coronary syndrome patients. It also indicated a regimen-dependent reduction in these concentrations upon treatment with antiplatelet drugs, thereby verifying the direct efficacy of the therapy. Notably, consistent concentrations of these aggregates were found in both venous and arterial blood, suggesting venous blood as a reliable therapy efficacy indicator, despite CAD’s arterial nature. These findings support personalized and improved antiplatelet therapy in CAD management.


  • Open Access

    Publisher Correction: High-throughput fluorescence lifetime imaging flow cytometry

    by Hiroshi Kanno, Kotaro Hiramatsu, Hideharu Mikami, Atsushi Nakayashiki, Shota Yamashita, Arata Nagai, Kohki Okabe, Fan Li, Fei Yin, Keita Tominaga, et al.


  • Open Access

    High-throughput fluorescence lifetime imaging flow cytometry

    by Hiroshi Kanno, Kotaro Hiramatsu, Hideharu Mikami, Atsushi Nakayashiki, Shota Yamashita, Arata Nagai, Kohki Okabe, Fan Li, Fei Yin, Keita Tominaga, et al.

    Flow cytometry is a vital tool in biomedical research and laboratory medicine. However, its accuracy is often compromised by undesired fluctuations in fluorescence intensity. While fluorescence lifetime imaging microscopy (FLIM) bypasses this challenge as fluorescence lifetime remains unaffected by such fluctuations, the full integration of FLIM into flow cytometry has yet to be demonstrated due to speed limitations. Here we overcome the speed limitations in FLIM, thereby enabling high-throughput FLIM flow cytometry at a high rate of over 10,000 cells per second. This is made possible by using dual intensity-modulated continuous-wave beam arrays with complementary modulation frequency pairs for fluorophore excitation and acquiring fluorescence lifetime images of rapidly flowing cells. Moreover, our FLIM system distinguishes subpopulations in male rat glioma and captures dynamic changes in the cell nucleus induced by an anti-cancer drug. FLIM flow cytometry significantly enhances cellular analysis capabilities, providing detailed insights into cellular functions, interactions, and environments.


  • Open Access

    Real-time intelligent classification of COVID-19 and thrombosis via massive image-based analysis of platelet aggregates

    by Chenqi Zhang, Maik Herbig, Yuqi Zhou, Masako Nishikawa, Mohammad Shifat-E-Rabbi, Hiroshi Kanno, Ruoxi Yang, Yuma Ibayashi, Ting-Hui Xiao, Gustavo K. Rohde, et al.

    Microvascular thrombosis is a typical symptom of COVID-19 and shows similarities to thrombosis. Using a microfluidic imaging flow cytometer, we measured the blood of 181 COVID-19 samples and 101 non-COVID-19 thrombosis samples, resulting in a total of 6.3 million bright-field images. We trained a convolutional neural network to distinguish single platelets, platelet aggregates, and white blood cells and performed classical image analysis for each subpopulation individually. Based on derived single-cell features for each population, we trained machine learning models for classification between COVID-19 and non-COVID-19 thrombosis, resulting in a patient testing accuracy of 75%. This result indicates that platelet formation differs between COVID-19 and non-COVID-19 thrombosis. All analysis steps were optimized for efficiency and implemented in an easy-to-use plugin for the image viewer napari, allowing the entire analysis to be performed within seconds on mid-range computers, which could be used for real-time diagnosis.

  • Open Access

    Massive image-based single-cell profiling reveals high levels of circulating platelet aggregates in patients with COVID-19

    by Masako Nishikawa, Hiroshi Kanno, Yuqi Zhou, Ting-Hui Xiao, Takuma Suzuki, Yuma Ibayashi, Jeffrey Harmon, Shigekazu Takizawa, Kotaro Hiramatsu, Nao Nitta, et al.

    A characteristic clinical feature of COVID-19 is the frequent incidence of microvascular thrombosis. In fact, COVID-19 autopsy reports have shown widespread thrombotic microangiopathy characterized by extensive diffuse microthrombi within peripheral capillaries and arterioles in lungs, hearts, and other organs, resulting in multiorgan failure. However, the underlying process of COVID-19-associated microvascular thrombosis remains elusive due to the lack of tools to statistically examine platelet aggregation (i.e., the initiation of microthrombus formation) in detail. Here we report the landscape of circulating platelet aggregates in COVID-19 obtained by massive single-cell image-based profiling and temporal monitoring of the blood of COVID-19 patients (n = 110). Surprisingly, our analysis of the big image data shows the anomalous presence of excessive platelet aggregates in nearly 90% of all COVID-19 patients. Furthermore, results indicate strong links between the concentration of platelet aggregates and the severity, mortality, respiratory condition, and vascular endothelial dysfunction level of COVID-19 patients.


  • Open Access

    Zhiyi’s Understanding of the Relationship between the Lotus Sūtra and the Mahāyāna Mahāparinirvāṇa Sūtra: Including a Comparison with Jizang’s Understanding

    by Hiroshi Kanno

    According to the Five-period classification that prevailed during the Northern and Southern Dynasties, the Lotus sūtra does not expound the doctrine of the Buddha-nature or the eternal abiding of the Buddha. In this point the Lotus sūtra was regarded as inferior to the Nirvāṇa sūtra. Zhiyi and Jizang criticize this Five-period classification, arguing instead that the Lotus sūtra, like the Nirvana sūtra, also expounds the doctrine of the Buddha-­nature or the eternal abiding of the Buddha. If their argument is to be accepted, why did the Buddha preach the Nirvāṇa sūtra after the Lotus sūtra? This is the problem taken up for consideration by Zhiyi and Jizang.


  • Ultrafast fluorescence lifetime imaging microscopy by frequency-division multiplexing (Conference Presentation)

    by Hiroshi Kanno, Hideharu Mikami, Keisuke Goda

    We demonstrate ultrafast fluorescence lifetime imaging microscopy (FLIM) based on frequency-division multiplexing. As a proof-of-concept demonstration, we obtained images with fluorescence intensity and lifetime contrasts of MCF-7 breast cancer cells stained by SYTO16 at a record high frame rate of 16,000 fps, which is 100 times higher than that of previously reported FLIM techniques. Our method is expected to expand the utility of FLIM to quantitative analysis of rapid intracellular dynamics and high-throughput cell screening based on fluorescence lifetime images.