HHHui Han

Hui Han

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hui Han has a total of 47 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Applying a Radiation Therapy Volume Analysis Pipeline to Determine the Utility of Spectroscopic MRI-Guided Adaptive Radiation Therapy for Glioblastoma

    by Anuradha G. Trivedi, Su Hyun Kim, Karthik K. Ramesh, Alexander S. Giuffrida, Brent D. Weinberg, Eric A. Mellon, Lawrence R. Kleinberg, Peter B. Barker, Hui Han, Hui-Kuo G. Shu, et al.

    Accurate radiation therapy (RT) targeting is crucial for glioblastoma treatment but may be challenging using clinical imaging alone due to the infiltrative nature of glioblastomas. Precise targeting by whole-brain spectroscopic MRI, which maps tumor metabolites including choline (Cho) and N-acetylaspartate (NAA), can quantify early treatment-induced molecular changes that other traditional modalities cannot measure. We developed a pipeline to determine how spectroscopic MRI changes during early RT are associated with patient outcomes to provide insight into the utility of adaptive RT planning. Data were obtained from a study (NCT03137888) where glioblastoma patients received high-dose RT guided by the pre-RT Cho/NAA twice normal (Cho/NAA ≥ 2x) volume, and received spectroscopic MRI scans pre- and mid-RT. Overlap statistics between pre- and mid-RT scans were used to quantify metabolic activity changes after two weeks of RT. Log-rank tests were used to quantify the relationship between imaging metrics and patient overall and progression-free survival (OS/PFS). Patients with lower Jaccard/Dice coefficients had longer PFS (p = 0.045 for both), and patients with lower Jaccard/Dice coefficients had higher OS trending towards significance (p = 0.060 for both). Cho/NAA ≥ 2x volumes changed significantly during early RT, putting healthy tissue at risk of irradiation, and warranting further study into using adaptive RT planning.


  • Open Access

    A Novel Approach to Determining Tumor Progression Using a Three-Site Pilot Clinical Trial of Spectroscopic MRI-Guided Radiation Dose Escalation in Glioblastoma

    by Karthik K. Ramesh, Vicki Huang, Jeffrey Rosenthal, Eric A. Mellon, Mohammed Goryawala, Peter B. Barker, Saumya S. Gurbani, Anuradha G. Trivedi, Alexander S. Giuffrida, Eduard Schreibmann, et al.

    Glioblastoma (GBM) is a fatal disease, with poor prognosis exacerbated by difficulty in assessing tumor extent with imaging. Spectroscopic MRI (sMRI) is a non-contrast imaging technique measuring endogenous metabolite levels of the brain that can serve as biomarkers for tumor extension. We completed a three-site study to assess survival benefits of GBM patients when treated with escalated radiation dose guided by metabolic abnormalities in sMRI. Escalated radiation led to complex post-treatment imaging, requiring unique approaches to discern tumor progression from radiation-related treatment effect through our quantitative imaging platform. The purpose of this study is to determine true tumor recurrence timepoints for patients in our dose-escalation multisite study using novel methodology and to report on median progression-free survival (PFS). Follow-up imaging for all 30 trial patients were collected, lesion volumes segmented and graphed, and imaging uploaded to our platform for visual interpretation. Eighteen months post-enrollment, the median PFS was 16.6 months with a median time to follow-up of 20.3 months. With this new treatment paradigm, incidence rate of tumor recurrence one year from treatment is 30% compared to 60–70% failure under standard care. Based on the delayed tumor progression and improved survival, a randomized phase II trial is under development (EAF211).


  • Value of multimodal MRI radiomics and machine learning in predicting staging liver fibrosis and grading inflammatory activity

    by Huanhuan Wei, Zehua Shao, Fangfang Fu, Xuan Yu, Yaping Wu, Yan Bai, Wei Wei, Nan Meng, Kewei Liu, Hui Han, et al.

    Objective: To evaluate the value of radiomics models created based on non-contrast enhanced T 1 weighted (T 1W) and T 2W fat-saturated (T 2WFS) images for staging hepatic fibrosis (HF) and grading inflammatory activity. Methods and materials: Data of 280 patients with pathologically confirmed HF and 48 healthy volunteers were included. The participants were divided into the training set and the test set at the proportion of 4:1 by the random seed method. We used the Pyradiomics software to extract radiomics features, and then use the least absolute shrinkage and selection operator to select the optimal subset. Finally, we used the stochastic gradient descent classifier to build the prediction models. DeLong test was used to compare the diagnostic performance of the models. Receiver operating characteristics was used to evaluate the prediction ability of the models. Results: The diagnostic efficiency of the models based on T 1W & T 2WFS images were the highest (all p < 0.05). When discriminating significant fibrosis (≥ F2), there were significant differences in the AUCs between the machine learning models based on T 1W and T 2WFS images (p < 0.05), but there were no significant differences in area under the receiver operating characteristic curves between the two models in other groups (all p > 0.05). Conclusion: The radiomics models built on T 1W and T 2WFS images are effective in assessing HF and inflammatory activity. Advances in knowledge: Based on conventional MR sequences that are readily available in the clinic, namely unenhanced T 1W and T 2W images. Radiomics can be used for diagnosis and differential diagnosis of liver fibrosis staging and inflammatory activity grading.


  • Open Access

    Ultra-Homogeneous B0 field for High-Field Body Magnetic Resonance Imaging with Unified Shim-RF Coils

    by Hsin-Jung Yang, Fardad Serry, Peng Hu, Zhaoyang Fan, Hyunsuk Shim, Anthony Christodoulou, Nan Wang, Alan Kwan, Yibin Xie, Yuheng Huang, et al.

    High-field magnetic resonance imaging (MRI, 3.0T and above) offers numerous advantages for imaging the human body over lower-field strengths. However, it suffers from unwanted fast spatially-varying main (B0 ) fields caused by the susceptibility mismatch at the tissue interfaces. When this is combined with the anatomical complexity of the human body, undesirable image artifacts can become damaging as they can compromise potential image contrasts, limit the use of accelerated imaging, and interfere with clinical interpretation. Consequently, these limitations restrict the effective utilization of high-field body MRI and emphasize the need for a major improvement in B0 field homogeneity to take full advantage of the ever increased B0 field. Here we introduce a Unified shim-RF Coil (UNIC) to overcome this existing bottleneck by transcending the conventional low-efficiency, distantly located B0 shim coils. UNIC allows a shim array to be freely allotted and seamlessly integrated into a standard surface RF coil, thus maximizing both the performance of RF receive sensitivity and effective B0 shimming. We demonstrate the capacity of the UNIC approach through detailed characterization of the coil design, prototyping a body coil integrating the UNIC features, and conducting in-vivo imaging of deep organs adjacent to the lung. Our studies provide evidence that UNIC enables homogeneous B0 fields in the liver and the heart, where strong image artifacts are known to occur, and hence facilitate the acquisition of unprecedented image quality in a clinical 3.0T scanner. Further, UNIC’s design is practical as it overcomes one of the most, if not the most, critical limitations of the state-of-the-art high-field MRI with minimal changes to the current MRI hardware architecture. Accordingly, the proposed technique offers opportunities for major advancements in noninvasive imaging of deep organs with high-field imaging in a way it has not been possible thus far.