MDMarcin Demkow

Marcin Demkow

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Marcin Demkow has a total of 93 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Stroke and Recurrent Thrombosis of the Coronary Arteries Probably due to Patent Foramen Ovale and Antebrachial Vein Thrombosis in Patient with STEMI – Case Report

    by Anna Konopka, Karolina Marzec, Katarzyna Paschalis-Purtak, Marcin Demkow, Joanna Zalewska, Elżbieta Smaga, Ilona Michałowska

    74- years old woman with history of cryptogenic stroke in 2010 (during hospitalisation at neurological department possible reasons of stroke were excluded at that time), with less than one year history of paroxysmal atrial fibrillation (AF) treated with apixaban, hypertension, diabetes type II, hypothyreotocsicosis and obesity was admitted to our hospital twice. For the first time admitted due to ST segment elevation myocardial infarction (STEMI) and episode of AF. Coronary angiography revealed occlusion of left circumflex coronary (LCX) artery and percutaneous coronary intervention (PCI) with stent implantation was performed. Conversions of AF episodes to sinus rhythm were spontaneous. Patient was discharged home and admitted once again three days after discharge. STEMI of anterior wall and a new episode of AF was diagnosed. Immediate plain old balloon angioplasty (POBA) with implantation of an additional stent in left anterior descending coronary artery (LAD) was performed. Sixty minutes after procedure, the patient developed symptoms of mild right-sided pyramidal syndrome and slight aphasia. Patient’s status was assessed on 3 points according to the National Institutes of Health Stroke Scale (NIHSS) and patient was not qualified for thrombolysis and mechanical thrombectomy of cerebral artery. Four days after symptoms of stroke, CT did not reveal new significant lesions of the brain and 8-th days after stroke aphasia almost completely disappeared. Thrombus in the left atrium appendage was excluded and patent foramen ovale (PFO) with left to right flow was revealed. Due to the risk of reverse flow as a possible reason of strokes (now and 15 years ago) and recurrent thromboembolisation of coronary arteries and presence of thromboembolisation of antebrachial vein the successful occlusion of PFO with Amplatzer Septal Occluder was performed. In good condition, patient was discharged home.

  • CT in Transcatheter-delivered Treatment of Valvular Heart Disease

    by Piotr Nikodem Rudzinski, Jonathon A. Leipsic, U. Joseph Schoepf, Dariusz Dudek, Florian Schwarz, Martin Andreas, Adriana Zlahoda-Huzior, Christian Thilo, Matthias Renker, Jeremy R. Burt, et al.

    There is an increasing role of cardiovascular imaging techniques in the transcatheter delivered treatment of valvular heart disease. Minimally invasive strategies to treat valvular heart disease have emerged over the past 2 decades. The use of transcatheter aortic valve replacement in the treatment of severe aortic stenosis, for...


  • Predictors of outcome in the ISCHEMIA-CKD trial: Anatomy versus ischemia

    by Kevin R. Bainey, Jerome L. Fleg, Judith S. Hochman, Dennis F. Kunichoff, Rebecca Anthopolos, Alexander M. Chernyavskiy, Marcin Demkow, Juan-Manuel Lopez-Quijano, Jorge Escobedo, Kian Keong Poh, et al.


  • Intravascular ultrasound for peri-procedural geometric orifice area measurement during transcatheter pulmonary valve replacement

    by L Kalinczuk, O Wozniak, G S Mintz, K Rynkiewicz, W Skotarczka, K Zielinski, I Michalowska, K Biernacka, W Ruzyllo, M Demkow

    Large imaging filed intravascular ultrasound (IVUS) offering superior online tomographic perspective and visual accuracy could guide transcatheter pulmonary valve replacement (TPVR) for right ventricular outflow tract (RVOT) insufficiency. It is unknown whether geometric orifice area (GOA) measured by IVUS corresponds with effective orifice area (EOA) measure by transthoracic echocardiography (TTE) after successful TPVR. To compare minimal inner-leaflets cross-sectional area delineated in systole (min GOA) measured by IVUS versus EOA calculated = right ventricle stroke volume (measured in baseline cardiac magnetic resonance) / pulmonary valve velocity time integral (measured early post-procedure by Vivid e95). After successful TPVR a 10MHz Vision PV 0.035" (60mm imaging field) IVUS catheter was slowly pulled from the distal pulmonary artery to the right ventricle with continuous imaging of RVOT. IVUS measurements included inner-valve dimension for several evenly spaced cross-sections along the entire length and perpendicular to RVOT long axis. Measured were outer-frame diameters (minimal and maximal) and its cross-sectional area, and cross-sectional area of the visual orifice (min GOA) identified exclusively at the coaptation site (Fig 1). There were 11 pts (median age 30 [25–36] yrs, 4 ♀, all but one with Tetralogy of Fallot) who had undergone prior corrective surgery (5 transannular patch, 2 bioprosthetic valve or 4 pulmonary homograft). Overall, 176 cross-sections were analyzed. Overall, min GOA measured 3.7±1.0cm2, and was 68%±9% of the valve-outer area (5.5±1.5cm2). It was substantially larger than calculated EOA (3.7±1.0cm2 vs 2.0±0.5cm2; p<0.001). The ratio of max/min GOA diameter was 1.11±0.11 signifying low eccentricity and was not related to EAO. After successful balloon-expandable valve implantation to treat RVOT insufficiency, geometric orifice dimension was significantly smaller then outer valve frame dimension. Visual measure of geometric orifice area during the procedure using IVUS documented its circularity and indicated that it was larger than EOA calculated upon functional measure. IVUS visualization of ES3. IVUS visualization of ES3.

  • Impact of annular and cusps calcification on occurrence of paravalvular leak after transcatheter aortic valve replacement with intra- versus supra-annular devices

    by I Michalowska, L Kalinczuk, M Dabrowski, Z Chmielak, K Zielinski, G.S Mintz, M Swierczewski, M Kumor, P Tyczynski, J Pregowski, et al.

    Introduction: Severe annular and valve cusps calcification is frequent among patients treated with transcatheter aortic valve replacement (TAVR). Severe annular calcification increases the risk of paravalvular leak (PVL) and was associated with worse outcomes. Whether it is accompanied by an independent effect of calcifications localized on cusps and whether the impact of cusps/annular calcification depends on supra vs intra-annular valve design is unknown. Purpose: To assess the impact of cusps/annular calcifications on occurrence of moderate PVL after successful TAVR with devices of either intra- or supra-annular design. Methods: 282 consecutive patients (80.3±7.6 yrs, 63% female) with baseline 384-slice CT scan were successfully treated with TAVR between Jul 2012 and Oct 2017, either with intra-annular or supra-annular devices. Severe annular calcification (clear protrusion) and severe cusps calcification (Rosenhek 4 score) were identified using a Syngo Via. Results: 138 (48.9%) patients were treated with intra-annular and 144 (51.15) with supra-annular devices. Whereas severe annular calcification was similar (23.9% vs 20.1%), there was more severe cusps calcification among intra-annular valves (52.9% vs 41.7%, p=0.073). Intra-annular devices were used less frequently among bicuspid aortic valves, were also of smaller diameter, less frequently deployed after pre-dilation, and less frequently post-dilated. Post-procedure mean aortic gradient tended to be higher among intra-annular devices. Moderate PVL was less frequent among intra- vs supra-annular valves (14.5% vs 34.0%, p<0.001). However, PVL occurrence was higher (30.3%) among those (33/138, 23.9%) treated with an intra-annular valve who had severe annular calcification vs 9.5% in pts treated with an intra-annular TAVR who did not have severe annular calcification (p=0.008) unlike in patients treated with a supra-annular valve who had a high frequency of PVL with or without severe annular calcium (37.9% vs 33.0%). After excluding patients with severe annular calcium (n=62, 22%), moderate PVL was similar between those with vs without severe cusp calcification whether treated with intra- or supra-annular valves (11.8% vs 7.4% and 29.3% vs 35.1%, respectively). Combined VARC-2 safety endpoints plus 2-yr mortality occurrence were lower for intra- vs supra-annular devices (30.4% vs 43.8%, p=0.026). Conclusions: Moderate PVL after intra-annular TAVR device deployment occurs in 30% of patients with protruding annular calcification. Severe cusps calcification unaccompanied by annular calcium was not associated with PVL occurrence. Higher frequency of moderate PVL (34%) seen after supra-annular valve deployment appears to be related to other parameters rather than presence of severe annular or cusps calcification. Funding Acknowledgement: Type of funding source: None

  • Open Access

    Elective versus rescue balloon aortic valvuloplasty for critical aortic stenosis

    by Paweł Tyczyński, Zbigniew Chmielak, Maciej Dąbrowski, Jarosław Skowroński, Krzysztof Kukuła, Patrycjusz Stokłosa, Marcin Demkow, Miłosz Marona, Witold Śmigielski, Janina Stępińska, et al.

    DOI: 10.33963/KP.15299, Published online: April 17, 2020, Authors: Paweł Tyczyński, Zbigniew Chmielak, Maciej Dąbrowski, Jarosław Skowroński, Krzysztof Kukuła, Patrycjusz Stokłosa, Marcin Demkow, Miłosz Marona, Witold Śmigielski, Janina Stępińska, Tomasz Hryniewiecki, Adam Witkowski


  • Open Access

    Long-term survival improvement with acute kidney recovery after successful transcatheter aortic valve replacement

    by Łukasz Kalińczuk, Kamil Zieliński, Zbigniew Chmielak, Gary S. Mintz, Maciej Dąbrowski, Ilona Kowalik, Mariusz Kłopotowski, Marcin Demkow, Tomasz Hryniewiecki, Ilona Michałowska, et al.

    DOI: 10.20452/pamw.15540, Published online: July 30, 2020, Authors: Łukasz Kalińczuk, Kamil Zieliński, Zbigniew Chmielak, Gary S. Mintz, Maciej Dąbrowski, Ilona Kowalik, Mariusz Kłopotowski, Marcin Demkow, Tomasz Hryniewiecki, Ilona Michałowska, Adam Witkowski

  • Open Access

    Severe Course of Peripartum Cardiomyopathy and Subsequent Recovery in a Patient with a Novel TTN Gene-Truncating Mutation

    by Karolina E. Kryczka, Zofia Dzielińska, Maria Franaszczyk, Izabela Wojtkowska, Jan Henzel, Mateusz Śpiewak, Janina Stępińska, Zofia T. Bilińska, Rafał Płoski, Marcin Demkow

    BACKGROUND:Peripartum cardiomyopathy (PPCM) is a potentially life-threatening, pregnancy-associated cause of heart failure affecting previously healthy women. Recent research suggests a possible role of 16-kDa prolactin in promoting cardiomyocyte dam...


  • The prevalence and characteristics of intra-atrial right coronary artery anomaly in 9,284 patients referred for coronary computed tomography angiography

    by Maksymilian P. Opolski, Jerzy Pregowski, Mariusz Kruk, Adam D. Staruch, Adam Witkowski, Marcin Demkow, Tomasz Hryniewiecki, Piotr Michalek, Witold Ruzyllo, Cezary Kepka


  • Impact of Different Re-stenting Strategies on Expansion of a Drug-Eluting Stent Implanted to Treat Bare-Metal Stent Restenosis

    by Łukasz Kalińczuk, Marcin Demkow, Gary S. Mintz, Krzysztof Cedro, Artur Dębski, Michał Ciszewski, Andrzej Ciszewski, Mariusz Kruk, Maciej Karcz, Grzegorz Warmiński, et al.