Anna Pukaluk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Anna Pukaluk has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Gerhard A. Holzapfel
Institute of Biomechanics, Graz University of Technology, Austria
7 shared publications - Gerhard Sommer
Institute of Biomechanics, Graz University of Technology, Austria
5 shared publications - Christian Viertler
Diagnostic and Research Institute of Pathology, Medical University of Graz, Austria
4 shared publications Heimo Wolinski
Institute of Molecular Biosciences, University of Graz, Austria; Field of Excellence BioHealth, University of Graz, Austria
4 shared publications- Peter Regitnig
Diagnostic and Research Institute of Pathology, Medical University of Graz, Graz, Austria
4 shared publications Alexander W. Caulk
Surgical, Medtronic, North Haven, CT, USA
3 shared publications
Latest Publications
- Open Access
Towards an understanding of injury in aortic tissue prior to actual failure: quantification of mechanically induced collagen damage using collagen hybridizing peptides
The development, validation, and optimization of endovascular aortic devices require quantitative assessment of tissue damage occurring during surgical interventions. Until now, this assessment—before complete failure—has been largely unfeasible for lack of a suitable methodology. Recently developed collagen hybridizing peptides (CHPs) allow selective detection of damage to collagen, the primary load-bearing constituent of the aortic wall. However, their application in large, mechanically loaded arteries has not yet been established. Therefore, we optimized an experimental workflow for large arteries that accounts for their energy-storage function and geometrical constraints; furthermore, we have characterized the tissue's autofluorescence and selected a suitable CHP fluorophore. Specimens from a single porcine aorta were examined using uniaxial tensile testing, histological analysis, fluorescence spectral analysis, confocal microscopy, and quantitative image analysis to present collagen damage as a function of tissue stretch. The workflow detected load-induced collagen damage before tissue failure, whereas histological evaluation showed no obvious load-induced disruption. Damage scores were comparable between the undeformed control and the specimen stretched by a factor of 1.2, while specimens stretched beyond 1.2 exhibited elevated scores. This pattern corresponded to higher complication rates with excessive stent oversizing. Furthermore, the proposed protocol can be adapted for ex vivo stent deployment experiments to compare collagen damage resulting from various aortic device designs and deployment conditions. Quantitative damage metrics could inform structurally motivated constitutive material models for computational simulations of endovascular interventions. Combined with histological and structural analyses, this workflow could also help link tissue composition—or organization—to individual susceptibility to damage.
Open AccessTowards an understanding of injury in aortic tissue prior to actual failure: quantification of mechanically induced collagen damage using collagen hybridizing peptides
The development, validation, and optimization of endovascular aortic devices require quantitative assessment of tissue damage occurring during surgical interventions. Until now, this assessment—before complete failure—has been largely unfeasible for lack of a suitable methodology. Recently developed collagen hybridizing peptides (CHPs) allow selective detection of damage to collagen, the primary load-bearing constituent of the aortic wall. However, their application in large, mechanically loaded arteries has not yet been established. Therefore, we optimized an experimental workflow for large arteries that accounts for their energy-storage function and geometrical constraints; furthermore, we have characterized the tissue's autofluorescence and selected a suitable CHP fluorophore. Specimens from a single porcine aorta were examined using uniaxial tensile testing, histological analysis, fluorescence spectral analysis, confocal microscopy, and quantitative image analysis to present collagen damage as a function of tissue stretch. The workflow detected load-induced collagen damage before tissue failure, whereas histological evaluation showed no obvious load-induced disruption. Damage scores were comparable between the undeformed control and the specimen stretched by a factor of 1.2, while specimens stretched beyond 1.2 exhibited elevated scores. This pattern corresponded to higher complication rates with excessive stent oversizing. Furthermore, the proposed protocol can be adapted for ex vivo stent deployment experiments to compare collagen damage resulting from various aortic device designs and deployment conditions. Quantitative damage metrics could inform structurally motivated constitutive material models for computational simulations of endovascular interventions. Combined with histological and structural analyses, this workflow could also help link tissue composition—or organization—to individual susceptibility to damage.
- Open Access
- 28 September 2026
- Published by Wiley in Advanced Science
- p. e77750
A General High‐Throughput Mucus Microrheology Platform for Quantitative and Scalable Mucus Phenotyping
Mucus mechanics regulate barrier, clearance, and transport functions across epithelial tissues, yet quantitative rheology remains difficult to scale because available assays require large volumes, specialized equipment, or extensive manual analysis. Here, a high‐throughput microrheology workflow based on Differential Dynamic Microscopy is established for frequency‐dependent measurements from 3 to 10 mucus samples and intact mucosal surfaces using standard epifluorescence microscopy. The workflow combines preloaded tracer chambers, controlled sample handling, short video acquisition, and automated analysis to reduce operator intervention while preserving sensitivity to mucus relaxation on 1–20 s time scales. Validation against shear rheometry and particle tracking in reconstituted mucin gels shows robust recovery of viscoelastic trends across mucus‐like material states. Applications in human airway epithelial air–liquid interface cultures resolve culture‐medium, age, donor, COPD, cigarette‐smoke, cystic‐fibrosis treatment, and IL‐13‐associated differences, including spatial heterogeneity in situ. Measurements of clinical cervical mucus further demonstrate parallel testing of scarce specimens and sensitivity to osmotic swelling. This platform provides a scalable route to quantitative mucus phenotyping for disease modeling, therapeutic testing, and future precision‐medicine studies.
- 28 September 2026
- Published by Wiley in Advanced Science
- p. e77750
Open AccessA General High‐Throughput Mucus Microrheology Platform for Quantitative and Scalable Mucus Phenotyping
Mucus mechanics regulate barrier, clearance, and transport functions across epithelial tissues, yet quantitative rheology remains difficult to scale because available assays require large volumes, specialized equipment, or extensive manual analysis. Here, a high‐throughput microrheology workflow based on Differential Dynamic Microscopy is established for frequency‐dependent measurements from 3 to 10 mucus samples and intact mucosal surfaces using standard epifluorescence microscopy. The workflow combines preloaded tracer chambers, controlled sample handling, short video acquisition, and automated analysis to reduce operator intervention while preserving sensitivity to mucus relaxation on 1–20 s time scales. Validation against shear rheometry and particle tracking in reconstituted mucin gels shows robust recovery of viscoelastic trends across mucus‐like material states. Applications in human airway epithelial air–liquid interface cultures resolve culture‐medium, age, donor, COPD, cigarette‐smoke, cystic‐fibrosis treatment, and IL‐13‐associated differences, including spatial heterogeneity in situ. Measurements of clinical cervical mucus further demonstrate parallel testing of scarce specimens and sensitivity to osmotic swelling. This platform provides a scalable route to quantitative mucus phenotyping for disease modeling, therapeutic testing, and future precision‐medicine studies.
- Open Access
- 31 May 2025
- Published by Elsevier in Acta Biomaterialia
- Vol. 201, 429-445
Native and decellularized porcine vena cava: Biomechanical and microstructural comparison
- 31 May 2025
- Published by Elsevier in Acta Biomaterialia
- Vol. 201, 429-445
Open AccessNative and decellularized porcine vena cava: Biomechanical and microstructural comparison
- Open Access
- 17 May 2025
- Published by Elsevier in Acta Biomaterialia
- Vol. 200, 265-282
A biomechanical comparative study of passive stomach tissue from pigs and humans
- 17 May 2025
- Published by Elsevier in Acta Biomaterialia
- Vol. 200, 265-282
Open AccessA biomechanical comparative study of passive stomach tissue from pigs and humans
- Open Access
A General High-throughput Mucus Microrheology Platform For Personalized Medicine
One-Sentence Summary: We here develop and validate an easy to implement, high-throughput microrheology platform to reliably quantify viscoelasticity in as little as 3 µL mucus droplet samples or intact mucosal surfaces based on Differential Dynamic Microscopy (DDM) that we demonstrate in a variety of in vitro and clinical applications. Mucus plays an integral role in the barrier function of many epithelial tissues, including respiratory, gastrointestinal, and reproductive systems. Understanding how mucus flow behavior, i.e., rheology, changes during disease progression and in response to treatments is of great interest for better differential diagnostics, pinpointing patient-specific disease mechanisms and respective personalized treatments. However, both basic and translational research of mucus rheology is greatly hampered by the lack of scalable and user-friendly rheology assays for the small volumes of mucus typically provided by in vitro respiratory models or from clinical samples. We report a streamlined, high-throughput, semi-automated mucus rheology approach, easy to implement for a variety of preclinical and clinical questions. It leverages Differential Dynamic Microscopy (DDM) to reliably measure the frequency-dependent microrheology of minuscule (3–10 µL-sized) mucus samples as well as in situ mucosal surfaces using standard epifluorescence microscopy. Overcoming complex and time-consuming user interventions of previous rheology and particle tracking routines, we achieve microrheology at the time scale of mucus relaxation (1–20 s), greatly reducing assay time. We validated our platform successfully in mucus samples and in situ mucosal surfaces: first in state-of-the-art air-liquid-interface (ALI) human respiratory cultures, where we compare mucus rheology of airway disease models and different culture conditions; second, assessing clinical samples of human patient cervical samples. Overall, our results add to an increasingly appreciated non-invasive, easy to use, body fluid-based personalized toolbox, with unprecedented opportunities for precision medicine and large-scale monitoring to further unveil functional roles of mucus in human health and disease.
Open AccessA General High-throughput Mucus Microrheology Platform For Personalized Medicine
One-Sentence Summary: We here develop and validate an easy to implement, high-throughput microrheology platform to reliably quantify viscoelasticity in as little as 3 µL mucus droplet samples or intact mucosal surfaces based on Differential Dynamic Microscopy (DDM) that we demonstrate in a variety of in vitro and clinical applications. Mucus plays an integral role in the barrier function of many epithelial tissues, including respiratory, gastrointestinal, and reproductive systems. Understanding how mucus flow behavior, i.e., rheology, changes during disease progression and in response to treatments is of great interest for better differential diagnostics, pinpointing patient-specific disease mechanisms and respective personalized treatments. However, both basic and translational research of mucus rheology is greatly hampered by the lack of scalable and user-friendly rheology assays for the small volumes of mucus typically provided by in vitro respiratory models or from clinical samples. We report a streamlined, high-throughput, semi-automated mucus rheology approach, easy to implement for a variety of preclinical and clinical questions. It leverages Differential Dynamic Microscopy (DDM) to reliably measure the frequency-dependent microrheology of minuscule (3–10 µL-sized) mucus samples as well as in situ mucosal surfaces using standard epifluorescence microscopy. Overcoming complex and time-consuming user interventions of previous rheology and particle tracking routines, we achieve microrheology at the time scale of mucus relaxation (1–20 s), greatly reducing assay time. We validated our platform successfully in mucus samples and in situ mucosal surfaces: first in state-of-the-art air-liquid-interface (ALI) human respiratory cultures, where we compare mucus rheology of airway disease models and different culture conditions; second, assessing clinical samples of human patient cervical samples. Overall, our results add to an increasingly appreciated non-invasive, easy to use, body fluid-based personalized toolbox, with unprecedented opportunities for precision medicine and large-scale monitoring to further unveil functional roles of mucus in human health and disease.
- Open Access
- 16 December 2024
- Published by Elsevier in Acta Biomaterialia
- Vol. 192, 101-118
Implications of compressive loading of the stomach wall: Interplay between mechanical deformation and microstructure
- 16 December 2024
- Published by Elsevier in Acta Biomaterialia
- Vol. 192, 101-118
Open AccessImplications of compressive loading of the stomach wall: Interplay between mechanical deformation and microstructure
- Open Access
- 22 February 2024
- Published by Elsevier in Acta Biomaterialia
- Vol. 178, 1-12
Multimodal experimental studies of the passive mechanical behavior of human aortas: Current approaches and future directions
- 22 February 2024
- Published by Elsevier in Acta Biomaterialia
- Vol. 178, 1-12
Open AccessMultimodal experimental studies of the passive mechanical behavior of human aortas: Current approaches and future directions
- Open Access
- 19 November 2023
- Published by Elsevier in Acta Biomaterialia
- Vol. 173, 167-183
Biomechanical characterization of the passive porcine stomach
- 19 November 2023
- Published by Elsevier in Acta Biomaterialia
- Vol. 173, 167-183
Open AccessBiomechanical characterization of the passive porcine stomach
- Open Access
- 21 February 2023
- Published by Elsevier in Acta Biomaterialia
- Vol. 161, 154-169
Changes in the microstructure of the human aortic adventitia under biaxial loading investigated by multi-photon microscopy
- 21 February 2023
- Published by Elsevier in Acta Biomaterialia
- Vol. 161, 154-169
Open AccessChanges in the microstructure of the human aortic adventitia under biaxial loading investigated by multi-photon microscopy
- Open Access
- 12 August 2022
- Published by Elsevier in Acta Biomaterialia
- Vol. 151, 396-413
Changes in the microstructure of the human aortic medial layer under biaxial loading investigated by multi-photon microscopy
- 12 August 2022
- Published by Elsevier in Acta Biomaterialia
- Vol. 151, 396-413
Open AccessChanges in the microstructure of the human aortic medial layer under biaxial loading investigated by multi-photon microscopy