SPSandipan Pati

Sandipan Pati

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sandipan Pati has a total of 245 co-authors. Here are the top co-authors by number of shared publications:

  • Ganne Chaitanya

    Department of Neurology, McGovern Medical School, University of Texas Health Science Center, Houston, TX, United States

    21 shared publications
  • Emilia Toth

    Department of Neurology, University of Alabama at Birmingham, Birmingham, AL, United States

    18 shared publications
  • Adeel Ilyas

    Department of Neurosurgery, UAB Heersink School of Medicine, Birmingham, AL, USA

    10 shared publications
  • Diana Pizarro

    Department of Neurology, University of Alabama at Birmingham

    10 shared publications
  • Karthi Balasubramanian

    Department of Electronics and Communication Engineering, Amrita School of Engineering, Coimbatore, Amrita Vishwa Vidyapeetham, Coimbatore, India

    8 shared publications
  • Kristen O. Riley

    Department of Neurological Surgery University of Alabama at Birmingham Birmingham Alabama USA

    7 shared publications

Latest Publications

  • Open Access

    Moving beyond spike detection: High frequency‐driven masking improves seizure onset zone localization in intracranial electroencephalography

    by Amir Hossein Ayyoubi, Behrang Fazli Besheli, Valentina Hrtonova, Jhan Luke Okkabaz, Chandra Prakash Swamy, Zhiyi Sha, Jay Gavvala, Nicholas Gregg, Thomas R. Henry, Sandipan Pati, et al.

    Objective: Interictal epileptiform spikes (IESs) are widely used biomarkers of epileptogenic tissue in presurgical epilepsy evaluation. However, their reliability for seizure onset zone (SOZ) localization in high‐density intracranial electroencephalography (iEEG) remains inconsistent. It is underexplored whether this variability reflects methodological differences across detection algorithms or a limitation of IESs as a biomarker. This study evaluates whether IES detection alone provides sufficient spatial specificity for accurate SOZ localization in iEEG. Methods: We systematically benchmarked eight established IES detection algorithms using iEEG recordings from 35 patients with drug‐resistant focal epilepsy. To provide a clinically meaningful reference, algorithm performance was evaluated against the clinically defined SOZ. To refine detection outputs and move beyond only IES detection, we applied masking strategies to isolate informative IES subsets based on rate, amplitude, frequency, and co‐occurrence with high‐frequency oscillations (HFOs). Conceptually, masking acts as a spatial refinement strategy that progressively restricts diffuse IES activity to more focal, pathologically relevant event populations. Results: Despite substantial variability in detection characteristics, SOZ localization performance (ratio of events originating from SOZ divided by total number of events) converged within a narrow range (.23–.51), suggesting that IESs exhibit an intrinsic ceiling in SOZ localization performance when used alone. Amplitude‐based masking yielded modest improvements, whereas frequency‐based masking reduced performance. In contrast, IES‐HFO co‐occurrence markedly improved localization, particularly when combined with rate‐based masking, achieving a median SOZ localization ratio of .89, exceeding IESs (.37) and HFOs (.63) evaluated independently. Significance: These findings demonstrate that IES‐based SOZ localization may require moving beyond detection‐only approaches. The integration of informed, biomarker‐driven masking strategies provides a more robust framework for identifying the activity most relevant to the epileptogenic network and paves the way for future incorporation into the clinical decision‐making pipeline.

  • Open Access

    Structural Covariance Networks From T1-MRI for Epilepsy Diagnosis: A Graph-Theoretical and Machine Learning Approach

    by K. C. Gurukarthi, K. C. Gurukumar, K. R. Rashmika, Biswambhar Rakshit, Sandipan Pati, Karthi Balasubramanian

  • Open Access

    Symbolic and Compression-Based Complexity in EEG: Benchmarking Frameworks and Thalamic Applications

    by Poornima Mohan, Sandipan Pati, Karthi Balasubramanian

    This work explores the use of symbolic and compression-based complexity measures for analysis of scalp and deep brain EEG signals, with a focus on thalamic EEG. We review symbolizing strategies, entropy based measures (permutation entropy (PE), dispersion entropy(DispEn)) and compression based metrics (Lempel-Ziv complexity (LZC) and Effort-to-Compress (ETC)) and their applicability to scalp EEG, stereo-electroencephalography (SEEG), and thalamic EEG are studied. Due to constraints in data accessibility, signal nonstationarity and variability in annotated data, adopting these methods for thalamic EEG analysis poses a significant challenge. To address this, a theoretical benchmarking facility is developed comprising of chaotic signal models, surrogate testing, and stochastic models. Further, the effects of preprocessing filtering, segmentation and transforms application are studied with respect to the symbolization process and metric analysis. By integrating concepts from nonlinear dynamical systems, we propose to develop a framework that goes beyond descriptive complexity measures and bridges the gaps between symbol encoding, phase space embedding, and deep brain dynamics. Our goal is to establish complexity analysis of symbolic EEG as a rigorous and clinically relevant framework for characterizing and interpreting brain dynamics, especially for deep brain structures.


  • Open Access

    Compression-Based Complexity Analysis of Thalamic EEG Using Multiscale Preprocessing Techniques

    by Poornima Mohan, Karthi Balasubramanian, Nithin Nagaraj, Gayathri R. Prabhu, Sandipan Pati

    Quantifying the complexity of biomedical signals offers critical insight into underlying physiological and pathological dynamics. This study systematically evaluates compression-based complexity measures—Effort-to-Compress (ETC) and Lempel-Ziv Complexity (LZC)—and compares them with classical entropy-based metrics, including Shannon Entropy, Approximate Entropy (ApEn), Sample Entropy (SampEn), and Permutation Entropy (PermEn). Analyses were performed on both synthetic benchmark signals and clinical thalamic EEG recordings acquired during seizure and non-seizure states. Robustness was assessed under Gaussian, Laplacian, and powerline noise, with and without preprocessing via Discrete Wavelet Transform (DWT) and Differential Pulse Code Modulation (DPCM). ETC consistently demonstrated the highest discriminative power and noise resilience, achieving large effect sizes and classification accuracies exceeding 85% when combined with full-scale DWT preprocessing. In contrast, LZC performed reliably in raw data but degraded following multiscale transformations. Entropy-based measures such as SampEn and ApEn remained competitive under clean conditions yet were more sensitive to noise and preprocessing variability. These findings establish that no single complexity metric is universally optimal; rather, performance depends on signal modality, noise structure, and preprocessing design. For thalamic EEG-based seizure detection, ETC with DWT preprocessing provides a robust, interpretable, and parameter-free framework suitable for clinical and real-time neurophysiological applications.


  • Open Access

    A Taxonomy-Driven Survey of AI for Seizure Detection: Thalamic Signals, Phase Dynamics, and Translational Gaps

    by Bhargava Ganti, Karthi Balasubramanian, Sandipan Pati

    Seizure prediction and postictal recovery remain critical challenges in epilepsy care, particularly in real-world, resource-constrained settings. This survey presents a taxonomy-driven synthesis of 150+ peer-reviewed studies spanning seizure phase modeling, thalamic EEG biomarkers, edge inference, and clinical AI integration.We introduce an eight-axis framework covering neurophysiological foundations, machine learning advances, wearable inference pipelines, large language model (LLM) assistants, and privacy-preserving architectures. A key focus is the emerging role of thalamic stereo-EEG (sEEG) as a high-fidelity substrate for modeling seizure transitions and informing closed-loop interventions. Unlike prior reviews, this work explicitly unifies preictal and postictal phase dynamics with modern AI tools—such as federated learning, explainable deep learning, and agentic reasoning. We highlight gaps in dataset diversity, clinical interpretability, and cross-center generalization, while proposing a translational roadmap toward ethical, explainable, and deployment-ready seizure care.


  • Open Access

    Precision neuromodulation in epilepsy: from shared targets to personalized circuits

    by Sandipan Pati

    This scientific commentary refers to ‘Thalamocortical network neuromodulation for epilepsy’, by Agashe et al. (https://doi.org/10.1093/braincomms/fcaf270).


  • Open Access

    Complexity Measures in Biomedical Signal Analysis: A Clinically-Grounded Survey Across EEG, ECG, Intracranial Pressure, and Photoplethysmogram Modalities

    by Karthi Balasubramanian, Sree Ranjani Rajendran, Sandipan Pati

    Biomedical signals such as electroencephalogram (EEG), electrocardiogram (ECG), intracranial pressure (ICP), and photoplethysmogram (PPG) encode complex dynamical patterns that reflect the adaptive control of physiological systems. Complexity analysis—through entropy, compression, and causality metrics—has emerged as a critical tool for early diagnosis, risk prediction, and continuous monitoring in clinical and wearable settings. This review presents a clinically grounded synthesis of key complexity measures, including Sample Entropy (SampEn), Permutation Entropy (PE), Lempel–Ziv Complexity (LZC), and Effort-to-Compress (ETC), as well as causal inference techniques like Granger Causality, Transfer Entropy, and Compression–Complexity Causality (CCC). Applications across neurological and cardiovascular pathologies—such as epilepsy and sudden unexpected death in epilepsy (SUDEP)—are examined alongside signal-specific preprocessing, interpretability, and statistical validation strategies. We further evaluate the feasibility of deploying these measures in real-time on constrained hardware platforms—microcontrollers, FPGAs, and RISC–V-based SoCs—highlighting their suitability for embedded health systems and remote diagnostics. The review also explores synergistic integration with explainable machine learning, showing how complexity-informed features can enhance both performance and interpretability. By bridging signal complexity with hardware-aware deployment, ML transparency, and clinical translation, this work aims to guide the development of scalable, interpretable, and secure biomedical analytics for next-generation digital health systems.


  • Open Access

    Slow Gamma Suppression Correlates with Therapeutic Response to Anterior Thalamic Deep Brain Stimulation in Intractable Epilepsy

    by Zachary T Sanger, Xinbing Zhang, Thomas Lisko, Hafsa Farooqi, Steffen Ventz, Sandipan Pati, Thomas Henry, David Darrow, Michael Park, Theoden I Netoff, et al.

    In drug-resistant epilepsy patients who undergo anterior thalamic deep brain stimulation (ANT-DBS), efficacy is assessed months after therapy initiation and clinicians have no guidance when choosing stimulation parameters due to the lack of real-time biomarkers. Here, we identified acute and chronic suppression of slow gamma oscillations (SGOs) (20–50Hz) in the ANT as a novel electrophysiological biomarker correlated with therapeutic response. Through analysis of an ongoing prospective ANT-DBS parameter optimization trial (N=11), 6/7 participants exhibiting SGOs were responders. Progressive suppression (“gamma fade”) of SGOs under chronic stimulation correlated with long-term seizure reduction in 5/6 responders. Acute stimulation in-clinic with multiple settings suppressed SGOs in 4/5 responders, challenging fixed-programming paradigms, with only one responder using the clinical gold standard parameters at the last follow-up visit. These findings establish SGO suppression as a potential multiscale biomarker for responder identification, parameter titration, and therapeutic tracking for precise, biomarker-guided intervention.


  • Open Access

    Time‐Frequency Fingerprint Analysis in SEEG Source‐Space to Identify the Epileptogenic Zone

    by Yash Shashank Vakilna, Deniz Atilgan, Johnson Hampson, Chinmay Chinara, Takfarinas Medani, Richard M. Leahy, Nuria Lacuey, Samden D. Lhatoo, Sandipan Pati, John C. Mosher, et al.

    This case study highlights the application of seizure fingerprint analysis in the source‐space of stereo‐EEG (SEEG) data to accurately localize the epileptogenic zone (EZ) in patients with complex cortical malformations. A 25‐year‐old female with extensive bilateral perisylvian polymicrogyria (PMG) presented with intractable focal seizures. The source‐level analysis performed in Brainstorm using the sLORETA imaging algorithm subsequently showed EZ fingerprint analysis. The patient underwent MR‐guided laser interstitial thermal therapy (LITT), targeting the identified EZ, resulting in postoperative seizure freedom with minimal complications. Extending the analysis from the sensor‐space to the source‐space could further enhance surgical planning and improve outcomes in complex epilepsy cases.


  • Open Access

    Inter-seizure variability in thalamic recruitment and its implications for precision thalamic neuromodulation

    by Pariya Salami, Angelique C. Paulk, Daniel J. Soper, Pierre Bourdillon, Peter N. Hadar, Omar A. Alamoudi, Nathaniel D. Sisterson, R. Mark Richardson, Sandipan Pati, Sydney S. Cash

    Background Thalamic stimulation is a promising approach to controlling seizures in patients with intractable epilepsy. It does not, however, provide good control for everyone. A big issue is that the role of the thalamus in seizure organization and propagation is unclear. When using responsive stimulation devices, they must detect seizure activity before sending stimulation. So, it’s important to know which parts of the thalamus are involved in different seizures. Methods To better choose thalamic targets for stimulation, we studied how different seizures spread to each stimulation target. Expert reviews and automated tools were used to identify seizure spread recorded from invasive recordings. We categorized seizures based on how they start and spread, and determined whether seizures reached thalamic areas early or late. We used generalized linear models (GLM) to evaluate which seizure properties are predictive of time of spread to the thalamus, testing effect significance using Wald tests. Results We show that seizures with <2 Hz synchronized-spiking patterns do not spread early to the thalamus, while seizures starting with faster activity (<20 Hz) spread early to all thalamic areas. Most importantly, seizures that begin broadly across the brain quickly recruit the centromedian and pulvinar areas, suggesting these may be better stimulation targets in such cases. Alternatively, seizures that start deep in the temporal lobe tend to involve the anterior part of the thalamus, meaning the centromedian might not be the best choice for those seizures. Conclusions Our results suggest that by analyzing electrical activity during seizures, we can better predict which parts of the thalamus are involved. This could lead to more effective stimulation treatments for people with epilepsy.