Eric Buffle
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Eric Buffle has a total of 89 co-authors. Here are the top co-authors by number of shared publications:
- Dominik Obrist
University of Bern
4 shared publications Christian Seiler
Department of Cardiology, University Hospital of Bern, Bern, Switzerland
3 shared publicationsAthanasios Papadis
Department of Cardiology, University Hospital of Bern, Bern, Switzerland
2 shared publications- Christian Seiler
Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
2 shared publications Christoph Gräni
Department of Cardiology, University Hospital of Bern, Bern, Switzerland
2 shared publicationsMichael Stucki
2 shared publications
Latest Publications
- Open Access
- 13 May 2026
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 64 (2) , 515-523
Quantification of Tricuspid Valve Regurgitation With 2D and 4D ‐Flow MRI : Comparison of Different Methods in Adult Patients With Ebstein's Anomaly
Background: Ebstein's anomaly (EA) is a congenital heart disorder involving tricuspid valve dysplasia and right heart abnormalities resulting in severe tricuspid regurgitation (TR). Multiple techniques assess regurgitation severity, but their correlation with EA severity markers remains unclear. Purpose: To compare MRI techniques for quantifying TR and regurgitant volume (RVol) in adults with EA. Study Type: Retrospective. Subjects: Thirty‐three adult patients with EA (15 males/18 females). Field Strength/Sequence: 3T or 1.5‐Tesla, 2D‐phase contrast (2D‐PC gradient echo) and 4D‐flow (gradient echo). Assessment: RVol was measured using three methods: (1) 2D‐indirect: subtraction of systolic pulmonary artery (PA) forward flow (2D‐PC) from functional right ventricular stroke volume (fRVSV); (2) 4D‐indirect: subtraction of PA systolic forward flow from tricuspid diastolic forward flow using 4D‐flow; (3) 4D‐direct: direct jet measurement with 4D‐flow. Correlations were evaluated between RVol and severity markers (left ventricular ejection fraction [LVEF], functional right ventricular end‐diastolic volume [fRVEDV], fRV/LV ratio, severity index volume, total right/left volume index, fRVEF). Statistical Tests: Pearson or Spearman correlation coefficients ( p < 0.05) significant. Results: The 4D‐direct method had the highest correlation with the mean RVol (2D‐indirect: r = 0.93, 4D‐indirect: r = 0.93; 4D‐direct: r = 0.95) and with severity markers: total right/left volume index (0.84, 0.64, 0.87), the fRVEDV (0.66, 0.58, 0.71), fRV/LVratio (0.81, 0.75, 0.87), and severity index volume (0.45, 0.59, 0.66). Data Conclusion: 4D‐flow enables intrinsic RVol quantification independent of fRV segmentation, with the direct jet method outperforming indirect approaches. Level of Evidence: 3. Technical Efficacy: Stage 2.
- 13 May 2026
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 64 (2) , 515-523
Open AccessQuantification of Tricuspid Valve Regurgitation With 2D and 4D ‐Flow MRI : Comparison of Different Methods in Adult Patients With Ebstein's Anomaly
Background: Ebstein's anomaly (EA) is a congenital heart disorder involving tricuspid valve dysplasia and right heart abnormalities resulting in severe tricuspid regurgitation (TR). Multiple techniques assess regurgitation severity, but their correlation with EA severity markers remains unclear. Purpose: To compare MRI techniques for quantifying TR and regurgitant volume (RVol) in adults with EA. Study Type: Retrospective. Subjects: Thirty‐three adult patients with EA (15 males/18 females). Field Strength/Sequence: 3T or 1.5‐Tesla, 2D‐phase contrast (2D‐PC gradient echo) and 4D‐flow (gradient echo). Assessment: RVol was measured using three methods: (1) 2D‐indirect: subtraction of systolic pulmonary artery (PA) forward flow (2D‐PC) from functional right ventricular stroke volume (fRVSV); (2) 4D‐indirect: subtraction of PA systolic forward flow from tricuspid diastolic forward flow using 4D‐flow; (3) 4D‐direct: direct jet measurement with 4D‐flow. Correlations were evaluated between RVol and severity markers (left ventricular ejection fraction [LVEF], functional right ventricular end‐diastolic volume [fRVEDV], fRV/LV ratio, severity index volume, total right/left volume index, fRVEF). Statistical Tests: Pearson or Spearman correlation coefficients ( p < 0.05) significant. Results: The 4D‐direct method had the highest correlation with the mean RVol (2D‐indirect: r = 0.93, 4D‐indirect: r = 0.93; 4D‐direct: r = 0.95) and with severity markers: total right/left volume index (0.84, 0.64, 0.87), the fRVEDV (0.66, 0.58, 0.71), fRV/LVratio (0.81, 0.75, 0.87), and severity index volume (0.45, 0.59, 0.66). Data Conclusion: 4D‐flow enables intrinsic RVol quantification independent of fRV segmentation, with the direct jet method outperforming indirect approaches. Level of Evidence: 3. Technical Efficacy: Stage 2.
- 1 April 2026
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 330 (4) , H1331-H1339
Relative aortic valve stiffness: a new parameter quantifying aortic stenosis
Aortic stenosis (AS) quantification relies on transvalvular gradients or aortic valve opening area (AVA). We present a new quantification method for AS based on new modeling of the aortic valve opening behavior. We fitted a sigmoid relation between flow rate and AVA and retrieved the “relative aortic valve stiffness” (rAVS). We could demonstrate its superior association with clinical endpoints compared with previous models in AS and provide a simple tool for its calculation using echocardiography.
- 1 April 2026
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 330 (4) , H1331-H1339
Relative aortic valve stiffness: a new parameter quantifying aortic stenosis
Aortic stenosis (AS) quantification relies on transvalvular gradients or aortic valve opening area (AVA). We present a new quantification method for AS based on new modeling of the aortic valve opening behavior. We fitted a sigmoid relation between flow rate and AVA and retrieved the “relative aortic valve stiffness” (rAVS). We could demonstrate its superior association with clinical endpoints compared with previous models in AS and provide a simple tool for its calculation using echocardiography.
- Open Access
- 23 December 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Imaging Methods and Practice
- Vol. 4 (1)
Measurement of turbulent kinetic energy with colour Doppler echocardiography and particle tracing velocimetry in an ex-vivo aortic stenosis model
Introduction: Grading of aortic stenosis (AS) is paramount to determine the ideal timing for aortic valve replacement. However, echocardiographic assessment of AS is challenging and subject to inaccuracy. Increased turbulent kinetic energy (TKE) in the aorta, created by a restricted opening stenotic aortic valve, could serve as a new marker for assessing AS severity. However, in this contest, TKE evaluated with ultrasound colour Doppler have not yet been clinically validated. Methods and results: Porcine aortic valves were tested ex-vivo in a left heart mock loop under various flowrates (1, 2.5, and 4 L/min) and three stiffness grades (SGa, SGb, SGc as native, stiffer, and stiffest stiffness grade, respectively). Reference TKE values were obtained using backlight particle tracking velocimetry. In parallel, TKE was estimated from ultrasound colour Doppler measurements by computing the local spatial fluctuations of blood flow velocities. Transvalvular pressure gradients were evaluated both with continuous wave Doppler and pressure sensors (PGaolv). At 4 L/min, pressure gradients with continuous wave Doppler for SGc reached severe AS levels (41 mmHg ± 14). Both TKE measurement methods, adjusted for flow rates, increased significantly across all stiffness grades and distinguished between severe (SGc) and non-severe (SGa and SGb) AS. Conclusion: In this ex-vivo AS model, both TKE measurement methods successfully differentiated severe from non-severe AS. These findings underscore the potential importance of ultrasound colour Doppler echocardiography in estimating energy loss through turbulence, paving the way for the development of a new diagnostic tool for grading AS severity.
- 23 December 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Imaging Methods and Practice
- Vol. 4 (1)
Open AccessMeasurement of turbulent kinetic energy with colour Doppler echocardiography and particle tracing velocimetry in an ex-vivo aortic stenosis model
Introduction: Grading of aortic stenosis (AS) is paramount to determine the ideal timing for aortic valve replacement. However, echocardiographic assessment of AS is challenging and subject to inaccuracy. Increased turbulent kinetic energy (TKE) in the aorta, created by a restricted opening stenotic aortic valve, could serve as a new marker for assessing AS severity. However, in this contest, TKE evaluated with ultrasound colour Doppler have not yet been clinically validated. Methods and results: Porcine aortic valves were tested ex-vivo in a left heart mock loop under various flowrates (1, 2.5, and 4 L/min) and three stiffness grades (SGa, SGb, SGc as native, stiffer, and stiffest stiffness grade, respectively). Reference TKE values were obtained using backlight particle tracking velocimetry. In parallel, TKE was estimated from ultrasound colour Doppler measurements by computing the local spatial fluctuations of blood flow velocities. Transvalvular pressure gradients were evaluated both with continuous wave Doppler and pressure sensors (PGaolv). At 4 L/min, pressure gradients with continuous wave Doppler for SGc reached severe AS levels (41 mmHg ± 14). Both TKE measurement methods, adjusted for flow rates, increased significantly across all stiffness grades and distinguished between severe (SGc) and non-severe (SGa and SGb) AS. Conclusion: In this ex-vivo AS model, both TKE measurement methods successfully differentiated severe from non-severe AS. These findings underscore the potential importance of ultrasound colour Doppler echocardiography in estimating energy loss through turbulence, paving the way for the development of a new diagnostic tool for grading AS severity.
- Open Access
- 6 November 2025
- Published by Oxford University Press (OUP) in Interdisciplinary CardioVascular and Thoracic Surgery
- Vol. 40 (11)
Haemodynamic Performance of Transcatheter Heart Valve in Bileaflet Mechanical Valve: An In-vitro Study
Objectives: This study evaluates the haemodynamic performance of a novel hybrid configuration—Valve-in-MHV—where a CoreValve transcatheter heart valve is implanted within the annulus of a composite valved graft after leaflet removal. Methods: In vitro testing was performed using left heart mock loop combined with backlight particle image velocimetry. Three configurations were assessed: (i) mechanical heart valve (MHV), (ii) CoreValve THV, and (iii) Valve-in-MHV. Flow parameters were measured at cardiac outputs of 3 and 5 L/min. Results: At 5 L/min, the Valve-in-MHV showed the highest PG (15.5 mmHg) and TKE (0.53 m2/s2), compared to the THV (10.9 mmHg, 0.31 m2/s2) and MHV (11.5 mmHg, 0.26 m2/s2). Effective orifice area was smallest for the Valve-in-MHV (1.44 cm2). The Valve-in-MHV generated a more physiological central jet than the MHV, but with increased turbulence and higher peak velocities (up to 2.66 m/s). Conclusions: Examining the mechanistic implications of Valve-in-MHV may offer valuable insights into the likelihood of adverse effects such as leaflet thrombosis and the development of pronounced pressure gradients in patients who are candidates for Valve-in-MHV.
- 6 November 2025
- Published by Oxford University Press (OUP) in Interdisciplinary CardioVascular and Thoracic Surgery
- Vol. 40 (11)
Open AccessHaemodynamic Performance of Transcatheter Heart Valve in Bileaflet Mechanical Valve: An In-vitro Study
Objectives: This study evaluates the haemodynamic performance of a novel hybrid configuration—Valve-in-MHV—where a CoreValve transcatheter heart valve is implanted within the annulus of a composite valved graft after leaflet removal. Methods: In vitro testing was performed using left heart mock loop combined with backlight particle image velocimetry. Three configurations were assessed: (i) mechanical heart valve (MHV), (ii) CoreValve THV, and (iii) Valve-in-MHV. Flow parameters were measured at cardiac outputs of 3 and 5 L/min. Results: At 5 L/min, the Valve-in-MHV showed the highest PG (15.5 mmHg) and TKE (0.53 m2/s2), compared to the THV (10.9 mmHg, 0.31 m2/s2) and MHV (11.5 mmHg, 0.26 m2/s2). Effective orifice area was smallest for the Valve-in-MHV (1.44 cm2). The Valve-in-MHV generated a more physiological central jet than the MHV, but with increased turbulence and higher peak velocities (up to 2.66 m/s). Conclusions: Examining the mechanistic implications of Valve-in-MHV may offer valuable insights into the likelihood of adverse effects such as leaflet thrombosis and the development of pronounced pressure gradients in patients who are candidates for Valve-in-MHV.
- Open Access
- 28 February 2024
- Published by Oxford University Press (OUP) in Interdisciplinary CardioVascular and Thoracic Surgery
- Vol. 38 (3)
Novel para-aortic cardiac assistance using a pre-stretched dielectric elastomer actuator
We propose an evolution of a dielectric elastomer actuator-based cardiac assist device that acts as a counterpulsation system. We introduce a new pre-stretched actuator and implant the device in a graft bypass between the ascending and descending aorta to redirect all blood through the device (ascending aorta clamped). The objective was to evaluate the influence of these changes on the assistance provided to the heart. The novel para-aortic device and the new implantation technique were tested in vivo in 5 pigs. We monitored the pressure and flow in the aorta as well as the pressure–volume characteristics of the left ventricle. Different activation timings were tested to identify the optimal device actuation. The proposed device helps reducing the end-diastolic pressure in the aorta by up to 13 ± 4.0% as well as the peak systolic pressure by up to 16 ± 3.6%. The early diastolic pressure was also increased up to 10 ± 3.5%. With different activation, we also showed that the device could increase or decrease the stroke volume. The new setup and the novel para-aortic device presented here helped improve cardiac assistance compared to previous studies. Moreover, we revealed a new way to assist the heart by actuating the device at different starting time to modify the left ventricular stroke volume and stroke work.
- 28 February 2024
- Published by Oxford University Press (OUP) in Interdisciplinary CardioVascular and Thoracic Surgery
- Vol. 38 (3)
Open AccessNovel para-aortic cardiac assistance using a pre-stretched dielectric elastomer actuator
We propose an evolution of a dielectric elastomer actuator-based cardiac assist device that acts as a counterpulsation system. We introduce a new pre-stretched actuator and implant the device in a graft bypass between the ascending and descending aorta to redirect all blood through the device (ascending aorta clamped). The objective was to evaluate the influence of these changes on the assistance provided to the heart. The novel para-aortic device and the new implantation technique were tested in vivo in 5 pigs. We monitored the pressure and flow in the aorta as well as the pressure–volume characteristics of the left ventricle. Different activation timings were tested to identify the optimal device actuation. The proposed device helps reducing the end-diastolic pressure in the aorta by up to 13 ± 4.0% as well as the peak systolic pressure by up to 16 ± 3.6%. The early diastolic pressure was also increased up to 10 ± 3.5%. With different activation, we also showed that the device could increase or decrease the stroke volume. The new setup and the novel para-aortic device presented here helped improve cardiac assistance compared to previous studies. Moreover, we revealed a new way to assist the heart by actuating the device at different starting time to modify the left ventricular stroke volume and stroke work.
- Open Access
- 10 November 2023
- Published by Elsevier in The American Journal of Cardiology
- Vol. 211, 287-290
Aortic Valve Planimetry in Aortic Stenosis Quantification: Reliability of Three-Dimensional-Multiplane Reconstruction and Comparison With Established Methods
- 10 November 2023
- Published by Elsevier in The American Journal of Cardiology
- Vol. 211, 287-290
Open AccessAortic Valve Planimetry in Aortic Stenosis Quantification: Reliability of Three-Dimensional-Multiplane Reconstruction and Comparison With Established Methods
- 18 July 2022
- Published by Elsevier in Journal of the American Society of Echocardiography
- Vol. 35 (11) , 1123-1132
Passive Leg Raise Stress Echocardiography in Severe Paradoxical Low-Flow, Low-Gradient Aortic Stenosis
- 18 July 2022
- Published by Elsevier in Journal of the American Society of Echocardiography
- Vol. 35 (11) , 1123-1132
Passive Leg Raise Stress Echocardiography in Severe Paradoxical Low-Flow, Low-Gradient Aortic Stenosis
- Open Access
- 3 May 2022
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 11 (9) , e024989
Yield of Echocardiography in Ischemic Stroke and Patients With Transient Ischemic Attack With Established Indications for Long‐Term Direct Oral Anticoagulant Therapy: A Cross‐Sectional Diagnostic Cohort Study
Background: We aimed to determine the diagnostic yield of transthoracic (TTE) and transesophageal echocardiography (TEE) in patients with ischemic stroke and transient ischemic attack with established indications for direct oral anticoagulants before the index event. Methods and Results: This was a retrospective cohort study of consecutive patients with preceding established indications for long‐term therapeutic direct oral anticoagulants presenting to a single comprehensive stroke center with ischemic stroke or transient ischemic attack. Choice of echocardiography modality was based on expert recommendations. The primary outcome was a composite of prespecified management‐relevant high‐risk findings adjudicated by an expert panel, based on TTE and TEE reports according to evidence‐based recommendations. Explorative analyses were performed to identify biomarkers associated with the primary outcome. Of 424 patients included (median [interquartile range] age, 78 [70–84] years; 175 [41%] women; National Institutes of Health Stroke Scale, 4 [1–12]; 67% atrial fibrillation), 292 (69%) underwent echocardiography, while 132 (31%) did not. Modality was TTE in 191 (45%) and TEE in 101 (24%). Median time from index event to echocardiography was 2 (1–3) days. TTE identified 26 of 191 (14%) patients with 35 management‐relevant pathologies. TEE identified 16 of 101(16%) patients with 20 management‐relevant pathologies. Most management‐relevant findings represented indicated coronary artery disease and valvular pathologies. In a further 3 of 191 (2%) patients with TTE and 4 of 101 (4%) patients with TEE, other relevant findings were identified. Variables associated with management‐relevant high‐risk pathologies included more severe stroke, diabetes, and laboratory biomarkers (NT‐proBNP [N‐terminal pro‐B‐type natriuretic peptide], C‐reactive protein, d ‐dimer, and troponin levels). Conclusions: In patients with established indications for long‐term direct oral anticoagulant therapy and stroke who received echocardiography, both TTE and TEE identified a relevant and similar proportion of management‐relevant high‐risk pathologies and predictive biomarkers could help to guide diagnostic workup in such patients.
- 3 May 2022
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 11 (9) , e024989
Open AccessYield of Echocardiography in Ischemic Stroke and Patients With Transient Ischemic Attack With Established Indications for Long‐Term Direct Oral Anticoagulant Therapy: A Cross‐Sectional Diagnostic Cohort Study
Background: We aimed to determine the diagnostic yield of transthoracic (TTE) and transesophageal echocardiography (TEE) in patients with ischemic stroke and transient ischemic attack with established indications for direct oral anticoagulants before the index event. Methods and Results: This was a retrospective cohort study of consecutive patients with preceding established indications for long‐term therapeutic direct oral anticoagulants presenting to a single comprehensive stroke center with ischemic stroke or transient ischemic attack. Choice of echocardiography modality was based on expert recommendations. The primary outcome was a composite of prespecified management‐relevant high‐risk findings adjudicated by an expert panel, based on TTE and TEE reports according to evidence‐based recommendations. Explorative analyses were performed to identify biomarkers associated with the primary outcome. Of 424 patients included (median [interquartile range] age, 78 [70–84] years; 175 [41%] women; National Institutes of Health Stroke Scale, 4 [1–12]; 67% atrial fibrillation), 292 (69%) underwent echocardiography, while 132 (31%) did not. Modality was TTE in 191 (45%) and TEE in 101 (24%). Median time from index event to echocardiography was 2 (1–3) days. TTE identified 26 of 191 (14%) patients with 35 management‐relevant pathologies. TEE identified 16 of 101(16%) patients with 20 management‐relevant pathologies. Most management‐relevant findings represented indicated coronary artery disease and valvular pathologies. In a further 3 of 191 (2%) patients with TTE and 4 of 101 (4%) patients with TEE, other relevant findings were identified. Variables associated with management‐relevant high‐risk pathologies included more severe stroke, diabetes, and laboratory biomarkers (NT‐proBNP [N‐terminal pro‐B‐type natriuretic peptide], C‐reactive protein, d ‐dimer, and troponin levels). Conclusions: In patients with established indications for long‐term direct oral anticoagulant therapy and stroke who received echocardiography, both TTE and TEE identified a relevant and similar proportion of management‐relevant high‐risk pathologies and predictive biomarkers could help to guide diagnostic workup in such patients.
- Open Access
- 31 January 2022
- Published by Elsevier in Indian Heart Journal
- Vol. 74 (2) , 120-126
The significance of pulmonary veins isolation radiofrequency time and the evolution of left atrium volume on a twelve-year observational follow-up of paroxysmal atrial fibrillation patients
- 31 January 2022
- Published by Elsevier in Indian Heart Journal
- Vol. 74 (2) , 120-126
Open AccessThe significance of pulmonary veins isolation radiofrequency time and the evolution of left atrium volume on a twelve-year observational follow-up of paroxysmal atrial fibrillation patients