Pooja Gupta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Pooja Gupta has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Samir Kumar Mondal
CSIR-Central Scientific Instruments Organisation
6 shared publications - Kaushal Vairagi
CSIR-Central Scientific Instruments Organisation
5 shared publications - Amit Pandey
CSIR-Central Scientific Instruments Organisation, Chandigarh, India
1 shared publication - Anshul Basra
Terminal Ballistic Research Laboratory, DRDO, Chandigarh, India
1 shared publication - Babankumar S. Bansod
Department of Material Science and Applications, CSIR-Central Scientific Instruments Organization, Chandigarh, India
1 shared publication - Jasleen Kaur
CSIR- Central Scientific Instruments Organisation, Chandigarh, India
1 shared publication
Latest Publications
- Open Access
- 5 March 2025
- Published by Springer Nature in Communications Physics
- Vol. 8 (1) , 1-7
On-fiber photonic nanojet enables super-resolution in en face optical coherence tomography and scattering nanoscopy
- 5 March 2025
- Published by Springer Nature in Communications Physics
- Vol. 8 (1) , 1-7
Open AccessOn-fiber photonic nanojet enables super-resolution in en face optical coherence tomography and scattering nanoscopy
- 16 May 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (11) , 20194-20206
Tissue characterization using axicon probe-assisted common-path optical coherence tomography
In this work, a common-path optical coherence tomography (OCT) system is demonstrated for characterizing the tissue in terms of some optical properties. A negative axicon structure chemically etched inside the fiber tip is employed as optical probe in the OCT. This probe generates a quality Bessel beam owning a large depth-of-field, ∼700 µm and small central spot size, ∼3 µm. The OCT system is probing the sample without using any microscopic lens. For experimental validation, the OCT imaging of chicken tissue has been obtained along with estimation of its refractive index and optical attenuation coefficient. Afterwards, the cancerous tissue is differentiated from the normal tissue based on the OCT imaging, refractive index, and optical attenuation coefficient. The respective tissue samples are collected from the human liver and pancreas. This probe could be a useful tool for endoscopic or minimal-invasive inspection of malignancy inside the tissue either at early-stage or during surgery.
- 16 May 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (11) , 20194-20206
Tissue characterization using axicon probe-assisted common-path optical coherence tomography
In this work, a common-path optical coherence tomography (OCT) system is demonstrated for characterizing the tissue in terms of some optical properties. A negative axicon structure chemically etched inside the fiber tip is employed as optical probe in the OCT. This probe generates a quality Bessel beam owning a large depth-of-field, ∼700 µm and small central spot size, ∼3 µm. The OCT system is probing the sample without using any microscopic lens. For experimental validation, the OCT imaging of chicken tissue has been obtained along with estimation of its refractive index and optical attenuation coefficient. Afterwards, the cancerous tissue is differentiated from the normal tissue based on the OCT imaging, refractive index, and optical attenuation coefficient. The respective tissue samples are collected from the human liver and pancreas. This probe could be a useful tool for endoscopic or minimal-invasive inspection of malignancy inside the tissue either at early-stage or during surgery.
- 10 January 2023
- Published by Optica Publishing Group in Applied Optics
- Vol. 62 (3) , 511-517
Reflective axicon based energy-efficient extended depth of focus quasi-Bessel beam probe for common-path optical coherence tomography
This work presents an optical fiber negative/reflective axicon probe that generates an energy-efficient quasi-Bessel beam (QBB) having a central spot (CS) possessing ∼ 20 % of the QBB power. With silver coating around the axicon, the CS power has been increased by ∼ 45 % . The QBB possesses a large depth of field, ∼ 400 µ m , with a micron order spot size as obtained experimentally. The probe has further been explored for common-path optical coherence tomography. The probe length has been optimized to minimize the path length difference between the reference and sample signal. With a divergence angle of just 0.013°, the beam provides a lateral resolution of ∼ 2.5 to ∼ 16 µ m for an axial distance of 0.1 to 1.0 mm. The imaging results are presented for standard samples such as onion and Scotch tape.
- 10 January 2023
- Published by Optica Publishing Group in Applied Optics
- Vol. 62 (3) , 511-517
Reflective axicon based energy-efficient extended depth of focus quasi-Bessel beam probe for common-path optical coherence tomography
This work presents an optical fiber negative/reflective axicon probe that generates an energy-efficient quasi-Bessel beam (QBB) having a central spot (CS) possessing ∼ 20 % of the QBB power. With silver coating around the axicon, the CS power has been increased by ∼ 45 % . The QBB possesses a large depth of field, ∼ 400 µ m , with a micron order spot size as obtained experimentally. The probe has further been explored for common-path optical coherence tomography. The probe length has been optimized to minimize the path length difference between the reference and sample signal. With a divergence angle of just 0.013°, the beam provides a lateral resolution of ∼ 2.5 to ∼ 16 µ m for an axial distance of 0.1 to 1.0 mm. The imaging results are presented for standard samples such as onion and Scotch tape.
- Open Access
- 4 November 2022
- Published by Optica Publishing Group in Optics Continuum
Reflective axicon based energy-efficient extended depth of focus Quasi-Bessel beam probe for common-path optical coherence tomography
- 4 November 2022
- Published by Optica Publishing Group in Optics Continuum
Open AccessReflective axicon based energy-efficient extended depth of focus Quasi-Bessel beam probe for common-path optical coherence tomography
- 27 August 2022
- Published by Springer Nature in Multidimensional Systems and Signal Processing
- Vol. 33 (4) , 1349-1365
Evaluation of acoustic modality features for moving vehicle identification
- 27 August 2022
- Published by Springer Nature in Multidimensional Systems and Signal Processing
- Vol. 33 (4) , 1349-1365
Evaluation of acoustic modality features for moving vehicle identification
- 3 March 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (8) , 1958-1964
Bessel beam with a micrometer-size central spot and interferometry for small volume bioliquid refractive index measurement
This work demonstrates an interferometric technique to measure the refractive index (RI) of microliter volume of biosample solutions with the help of an optical fiber negative axicon and Bessel beam with the micrometer-size central spot. The RI measuring device consists of a broadband superluminescent diode (SLD) source along with an optical circulator and spectrometer. The axicon optical fiber probe packaged with a glass slide is connected to a broadband SLD source through an optical circulator, and a drop of microliter bioliquid sample is placed on the packaged probe’s head. The reflected light from the glass–liquid interface couples back to the axicon probe and interferes with the reference beam generated at the air–glass interface of the axicon. The interference spectrum is further analyzed by applying the fast Fourier transform to calculate power from the respective interface and solve the Fresnel equation for the RI measurement. The RI of small sample volume ∼ 2 µ l of glucose solutions and bovine serum albumin protein solutions are reported as an application of the proposed method. This sensing platform shows promising applications in biomedicine for monitoring small volume various biosample concentrations. We also demonstrate RI measurement of flowing liquid sample using the developed setup in case the design can be considered for microfluidic channel research.
- 3 March 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (8) , 1958-1964
Bessel beam with a micrometer-size central spot and interferometry for small volume bioliquid refractive index measurement
This work demonstrates an interferometric technique to measure the refractive index (RI) of microliter volume of biosample solutions with the help of an optical fiber negative axicon and Bessel beam with the micrometer-size central spot. The RI measuring device consists of a broadband superluminescent diode (SLD) source along with an optical circulator and spectrometer. The axicon optical fiber probe packaged with a glass slide is connected to a broadband SLD source through an optical circulator, and a drop of microliter bioliquid sample is placed on the packaged probe’s head. The reflected light from the glass–liquid interface couples back to the axicon probe and interferes with the reference beam generated at the air–glass interface of the axicon. The interference spectrum is further analyzed by applying the fast Fourier transform to calculate power from the respective interface and solve the Fresnel equation for the RI measurement. The RI of small sample volume ∼ 2 µ l of glucose solutions and bovine serum albumin protein solutions are reported as an application of the proposed method. This sensing platform shows promising applications in biomedicine for monitoring small volume various biosample concentrations. We also demonstrate RI measurement of flowing liquid sample using the developed setup in case the design can be considered for microfluidic channel research.
- 18 January 2022
- Published by Optica Publishing Group in Optics Letters
- Vol. 47 (3) , 497-500
All-fiber negative axicon probe with a Bessel beam for cellular-level low coherence phase microscopy and refractive index measurement
We demonstrate an all-fiber negative axicon probe with a Bessel beam for low coherence phase microscopy including refractive index measurement of a cellular level sample in reflection mode. The negative axicon chemically incised at the distal end of the optical fiber spawns the Bessel beam. The system provides a phase sensitivity of ∼0.28 mrad and optical path length sensitivity of ∼23 pm in air. The lateral resolution and working distance are found to be ∼3.91 µm and 650 µm to exhibit the performance of the system experimentally. The three-dimensional (3D) phase map of the cheek cell along with the refractive index is obtained from the reflected power spectrum. The combined low coherence phase microscopy and refractive index measurement provides the system with a potential for biological application. Also, the all-fiber probe can be easily integrated as an endoscopic probe.
- 18 January 2022
- Published by Optica Publishing Group in Optics Letters
- Vol. 47 (3) , 497-500
All-fiber negative axicon probe with a Bessel beam for cellular-level low coherence phase microscopy and refractive index measurement
We demonstrate an all-fiber negative axicon probe with a Bessel beam for low coherence phase microscopy including refractive index measurement of a cellular level sample in reflection mode. The negative axicon chemically incised at the distal end of the optical fiber spawns the Bessel beam. The system provides a phase sensitivity of ∼0.28 mrad and optical path length sensitivity of ∼23 pm in air. The lateral resolution and working distance are found to be ∼3.91 µm and 650 µm to exhibit the performance of the system experimentally. The three-dimensional (3D) phase map of the cheek cell along with the refractive index is obtained from the reflected power spectrum. The combined low coherence phase microscopy and refractive index measurement provides the system with a potential for biological application. Also, the all-fiber probe can be easily integrated as an endoscopic probe.
- 1 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 276-281
A simple approach for image enhancement using new power-law transformation operators
In this paper, we present a new approach for the enhancement of a highly underexposed color image using a power-law transformation operator. A function called exposure [1] is used to measure the intensity exposition of the image. This function facilitates the estimation of highly underexposed region of the given image. The chromatic information of the color space is decoupled from the achromatic information using HSV (Hue, Saturation and Intensity) model. The hue component, in the model is preserved to keep the original color composition of the image intact. The other two components of the model are saturation and intensity. These two components play a significant role in enhancement of highly underexposed images by recovering the lost information in the image. New power-law transformation operators are defined for the two components, i.e. saturation and intensity, to improve the tone of the image. The values of these two components are varied to get the enhanced image.
- 1 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 276-281
A simple approach for image enhancement using new power-law transformation operators
In this paper, we present a new approach for the enhancement of a highly underexposed color image using a power-law transformation operator. A function called exposure [1] is used to measure the intensity exposition of the image. This function facilitates the estimation of highly underexposed region of the given image. The chromatic information of the color space is decoupled from the achromatic information using HSV (Hue, Saturation and Intensity) model. The hue component, in the model is preserved to keep the original color composition of the image intact. The other two components of the model are saturation and intensity. These two components play a significant role in enhancement of highly underexposed images by recovering the lost information in the image. New power-law transformation operators are defined for the two components, i.e. saturation and intensity, to improve the tone of the image. The values of these two components are varied to get the enhanced image.