Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dianpeng Qi has a total of 325 co-authors. Here are the top co-authors by number of shared publications:

  • Yan Liu

    MIIT Key Laboratory of Critical Materials Technology for New Energy Conversion and Storage National and Local Joint Engineering Laboratory for Synthesis Transformation and Separation of Extreme Environmental Nutrients School of Chemistry and Chemical Engineering Harbin Institute of Technology Harbin China

    19 shared publications
  • Cuiyuan Liang

    College of Chemistry and Chemical Engineering Northeast Petroleum University Daqing Heilongjiang China

    18 shared publications
  • Dan Yang

    National and Local Joint Engineering Laboratory for Synthesis Transformation and Separation of Extreme Environmental Nutrients School of Chemistry and Chemical Engineering Harbin Institute of Technology Harbin P. R. China

    14 shared publications
  • Qinyi Zhao

    National and Local Joint Engineering Laboratory for Synthesis Transformation and Separation of Extreme Environmental Nutrients School of Chemistry and Chemical Engineering Harbin Institute of Technology Harbin P. R. China

    14 shared publications
  • Gongwei Tian

    State Key Laboratory of Utilization of Woody Oil Resources, Key Laboratory of Bio‐based Material Science and Technology of Ministry of Education Northeast Forestry University Harbin P. R. China

    13 shared publications
  • Jianhui Chen

    National and Local Joint Engineering Laboratory for Synthesis Transformation and Separation of Extreme Environmental Nutrients School of Chemistry and Chemical Engineering Harbin Institute of Technology Harbin P. R. China

    13 shared publications

Latest Publications

  • Open Access

    Biomass Based Sensors: From Native Structures to Functional Enhancement and Degradation

    by Yimin Shi, Xuchao Wei, Desheng Wang, Ruiwen Tian, Chuanbiao Wu, Yuping Qi, Dianpeng Qi

    The rapid expansion of wearable electronics, environmental monitoring, soft robotics, and the Internet of Things (IoT) has intensified the demand for sensing systems that combine reliable performance with reduced environmental burden. Biomass derived materials offer a promising route toward this goal by uniting renewable origin, structural diversity, rich interfacial chemistry, and inherent degradability within a single material platform. Yet their practical value extends beyond the straightforward replacement of synthetic polymers with natural alternatives. Recent progress has demonstrated that biomass can be engineered into functional sensing platforms through structural regulation, conductive interface design, and controlled degradation management. In this Review, biomass based sensors are examined from an integrated perspective spanning materials, devices, and end of life behavior. The intrinsic architectures and chemical functionalities of representative biomass materials are discussed in relation to their roles in enabling mechanical adaptability, electrical integration, and diverse sensing modalities, as well as in shaping durability and degradation pathways after service. By linking performance enhancement with sustainability assessment, the emerging potential of biomass derived materials as competitive candidates for high performance sensing systems with more responsible life cycles is highlighted.

  • Challenges and Strategies for Addressing the Sensitivity‐Detection Range Trade‐Off in Flexible Pressure Sensors

    by Cuiyuan Liang, Xinyu Zhang, Yannan Wang, Bin Feng, Shumin Niu, Dan Yang, Jianhui Chen, Qinyi Zhao, Gongwei Tian, Ming Zhu, et al.

    Flexible pressure sensors, as core devices in the field of flexible electronics, exhibit great potential for applications in wearable health monitoring, intelligent robotics, and human‐machine interaction. This huge application potential is attributed to their excellent mechanical flexibility, conformability, and real‐time response capabilities. However, during performance optimization, these sensors encounter a critical bottleneck, namely the inherent trade‐off between high sensitivity and a wide detection range: High sensitivity typically relies on microstructures or interfaces with low stiffness that are prone to deformation, yet these are susceptible to structural saturation or damage under elevated pressures (>10 kPa). Conversely, a wide detection range requires the sensor to possess high structural robustness and resistance to deformation, which often results in weak signal responses in the low‐pressure regime. To overcome this challenge, this review systematically elaborates on the root causes of this inherent trade‐off, which makes it challenging to achieve high sensitivity and a wide detection range simultaneously. It primarily highlights various innovative strategies proposed in recent years to address this issue through microstructural design, including conventional microstructures, nanofiber microstructures, biomimetic microstructures, and synergistic microstructures. Finally, future research directions are outlined to provide theoretical guidance and technical references for developing next‐generation high‐performance flexible pressure sensors.


  • Open Access

    Temperature‐Triggered Reversible Conductive Adhesive Enabling Reconfigurable and Recyclable Soft–Rigid Hybrid Electronics

    by Jing Sun, Huan Yu, Huoerhute Yelemulati, Hang Zhao, Qiong Tian, Yan Liu, Fei Long, Qinyi Zhao, Sida Wang, Xinyue Hu, et al.

    Flexible and stretchable electronics enable emerging applications in wearable systems, soft devices, and human–machine interfaces. As these systems often rely on hybrid architectures that integrate soft, deformable substrates with rigid electronic components, their practical implementation is often limited by irreversible or mechanically incompatible interconnects at soft–rigid interfaces, which hinder component replacement, system maintenance, and recycling. Here, we introduce a temperature‐triggered reversible conductive adhesive (TRCA) that simultaneously provides stable electrical interconnection and controllable interfacial debonding. At room temperature, TRCA provides reliable conductive adhesion for integrating rigid components onto stretchable circuits, while cooling to a predefined triggering temperature (∼−20°C) significantly reduces the adhesive strength, enabling detachment with minimal visible residue. With thermally switchable adhesion and tunable rheology, TRCA supports the direct construction of stretchable electronic platforms that host various sensors, including pressure, temperature, and strain modules, thereby enabling modular assembly, replacement, and reuse of functional components. Furthermore, TRCA facilitates reversible functional expansion of flexible gold‐film electrodes from electrophysiological recording to integrated sensing and subsequent recovery without noticeable signal degradation. TRCA establishes a materials‐driven interconnection strategy that integrates reversible adhesion, electrical reliability, and recyclability, offering a practical route for reconfigurable and sustainable soft–rigid hybrid electronics.

  • An Injectable Hydrogel Foam Enables Mechanical Resilience and Zero-Order Release of Growth Factors for Intervertebral Disc Repair

    by Guoyong Han, Chaoyuan Li, Hao Dou, Dianpeng Qi, Bai Yang, Wanguo Liu, Rui Gu, Yunfeng Li

    Intervertebral disc degeneration (IVDD) is a global challenge to cure effectively. Although current hydrogel-based therapies are promising, they often have difficulty of completely reversing IVDD progression. Herein, we report an injectable and growth factor-laden hydrogel foam (IHFs@GFs) for the treatment of IVDD. IHF is prepared from methylphenyltetrazine-modified hyaluronic acid (HA-MTZ), norbornene-modified gelatin (Gelatin-NB), and norbornene-modified cellulose nanofibers (CNF-NB). MTZ reacts with NB to release N2, spontaneously generating numerous closed and spherical N2 bubbles in hydrogels. These N2 bubbles endow IHF with good mechanical resilience and pressure buffering. Moreover, IHF shows zero-order release of transforming growth factor-β3 and insulin-like growth factor-1. Notably, after 8 weeks of treatment with IHFs@GFs, the disc height and hydration in degenerated IVD are significantly restored to over 90%, thereby enabling effective treatment of IVDD. The IHF integrates biomechanics and zero-order release of biologics within a single system, offering a promising platform for IVDD treatment.

  • Open Access

    Soft Hypoxia‐Adaptive Bioelectronics Integrating PEDOT:PSS/Polydopamine/Enzyme Biocomposites for Closed‐Loop Therapeutics of Chronic Wounds

    by Songrui Liu, Bowen Yang, Cao Qi, Zhijie Zhou, Haochen Zou, Anjum Qureshi, Xiao Zhao, Ting Li, Li Gao, Ye Tao, et al.

    Adaptive bioelectronics that autonomously adjust to environmental changes represent an emerging paradigm, enabling reliable operation across diverse conditions. Hypoxic microenvironments are prevalent across numerous pathological conditions including chronic wounds, tumors, and ischemic tissues, creating a fundamental challenge: oxygen‐dependent enzymatic biosensors fail precisely when monitoring is most critical, while oxygen deficiency simultaneously impairs tissue regeneration. We present a soft wireless Hypoxia‐Adaptive Sensing and Therapeutic (HAST) system that maintains reliable biosensing functionality in oxygen‐deficient environments through integrated oxygen management. Using engineered poly(3,4‐ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS)/polydopamine (PDA)/enzyme biocomposites, HAST integrates multiplexed biosensing (glucose, uric acid, lactate) with dual‐oxygen provision: wound exudate‐triggered dissolved oxygen generation restores biosensor functionality while electrical stimulation promotes vascular regeneration for sustained tissue oxygenation. This hypoxia‐adaptive design achieves about 10‐fold biosensor sensitivity enhancement under oxygen‐deficient conditions while promoting tissue repair. In preclinical diabetic wound models, HAST enabled accurate continuous monitoring with ∼30% accelerated wound closure, demonstrating environment‐adaptive bioelectronics for precision medicine in oxygen‐deficient pathological conditions.


  • Open Access

    Facet‐engineered BiSI nanorods for intelligent distinguishing detection of NO 2 / H 2 S mixed gas

    by Zhenze Zhou, Juanyuan Hao, Dan Shi, Haoxin Lei, Dianpeng Qi

    Room‐temperature detection of harmful gases is essential for industrial intelligence, whereas the development of practical multigas sensors for real‐world applications remains insufficient. Guided by density functional theory calculations, which reveal the superior adsorption and charge‐transfer capability of the BiSI (121) facet toward both NO 2 and H 2 S, a facet‐engineered BiSI nanorod sensor was designed to achieve bifunctional sensing, exhibiting remarkable responses of 610% and −437% to 1 ppm NO 2 and H 2 S at room temperature, respectively. Further integration of the single facet‐controlled BiSI sensor with a back‐propagation neural network allows for the intelligent analysis of mixed gases, achieving both distinguishing detection and concentration prediction. This systematic design effectively overcomes the limitations of high‐power consumption and complex modulated operating conditions. This strategy provides a low‐power and integrated generalizable framework for simultaneous multigas detection, applicable to a wide range of industrial and environmental monitoring scenarios. image


  • Open Access

    Reversible Thermoactuation Unlocks Minimally Invasive Implantation and Retrieval of Soft Bioelectronics

    by Qinyi Zhao, Qiliang Liu, Bin Li, Xuemiao Yang, Jiazhen Yan, Jixiang Zou, Rui Zhang, Gongwei Tian, Mingxuan Cui, Qiulin Wang, et al.

    Minimally invasive delivery of bioelectronics is currently limited by the irreversibility of deployment, rendering device retrieval traumatic and hindering clinical translation. Here, for the first time, we introduce a novel thermoresponsive, reversible‐actuating polymer (Trap) that enables both minimally invasive implantation and retrieval. Trap exhibits a mechanistically unique dual‐crystalline competition between (110)‐oriented low‐entropy crystals and (100)‐oriented high‐entropy crystals. The competitive crystallization governs bidirectional, stress‐free shape memory within a human‐compatible window (10°C–37°C), enabling rapid (<3 s), fatigue‐resistant, and large reversible strain (∼30.17%). The solid–solid switching between two nanocrystalline states provides a robust and tunable actuation mode, allowing Trap to transition reversibly between compact 1D and functional 2D/3D geometries without mechanical loading. This materials’ innovation directly enables microinvasive deployment and retraction of Trap‐based neural electrodes through the same small incision (∼5 mm), as well as autonomous helical self‐assembly and thermal detachment on peripheral nerves, achieving stable electrophysiological interfacing over weeks to months. This work establishes a material‐centered framework for reversible biointerfaces, resolving the conflict between surgical invasiveness and device retrievability.

  • Open Access

    AI-Enabled Electrochemical Glucose Sensing: Towards Intelligent and Modernized Health Monitoring

    by Dianpeng Qi, Jifan Zhang, Hao Dou

    The rising prevalence of diabetes has made high-precision, continuous glucose monitoring a central challenge in intelligent health management. This review systematically examines recent advances in artificial intelligence (AI)-enabled electrochemical glucose sensing. We overview mainstream machine learning (ML) algorithms and their applications in electrochemical signal modeling, denoising, feature extraction, and adaptive calibration. Four representative platform categories are analyzed: enzyme-based sensors, non-enzymatic and affinity-based systems, electrochemiluminescence (ECL) sensing, and wearable continuous monitoring platforms. Representative studies show that ML algorithms such as support vector regression (SVR), XGBoost, and random forest (RF) can substantially improve analytical performance, with detection limits reduced from 100 nM to 10 nM and R2 values exceeding 0.9 in selected cases. The deep integration of AI and electrochemical sensing is transforming glucose detection from passive measurement to active cognition, namely to sensing systems that not only record signals but also perform adaptive denoising, drift correction, individualized calibration, and predictive decision support. This transition points toward explainable, low-power, privacy-aware, and wearable personalized health monitoring systems.

  • Ultrasensitive room-temperature H 2 S sensing enabled by interfacial engineering via Bi-shared Bi 2 S 3 /BiOI heterostructures

    by Zhenze Zhou, Dianpeng Qi, Hui Zhang, Ming Zhu, Dan Shi, Meiling Yu, Haoxin Lei, Juanyuan Hao

    Bi 2 S 3 /BiOI heterostructures enable ultrasensitive, low-power, room-temperature H 2 S detection through enhanced interfacial charge transfer, showing strong potential for non-invasive breath analysis of halitosis.

  • Degradable Living Plastics Programmed by Engineered Microbial Consortia

    by Chenwang Tang, Jing Sun, Qing Wang, Runtao Zhu, Lin Wang, Guangfa Xiang, Jiaxin Tang, Jie Li, Hang Zhao, Shuhui Li, et al.