TKTobias Konow

Tobias Konow

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tobias Konow has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Stem size and stem alignment affects periprosthetic fracture risk and primary stability in cementless total hip arthroplasty

    by Tobias Konow, Katja Glismann, Frank Lampe, Benjamin Ondruschka, Michael M. Morlock, Gerd Huber

    The ideal stem size and stem position is important for the success of total hip arthroplasty, since it can affect early implant loosening and periprosthetic fractures (PPF). This study aimed to investigate how small deviations from the ideal stem size and position influences the PPF risk and primary stability. Six experienced surgeons performed preoperative templating based on which the benchmark size for each femur was determined. Consecutive implantations were performed in six cadaveric femur pairs—one side was implanted with an undersized stem followed by the benchmark size and the contralateral side with a benchmark size followed by an oversized stem (Corail, Depuy Synthes). Moreover, three different alignments (six varus, six neutral, six valgus‐undersized) were compared using 18 femurs. Cortical strains during broaching and implantation were measured, and laser scans were used to determine final stem position. All specimens underwent dynamic loading. Primary stability was estimated from stem subsidence and pull‐out forces. Templated stem size varied between surgeons (±1 size; p = 0.005). Undersizing increased stem subsidence by 320% (p < 0.001). Oversized stems exhibited 52% higher pull‐out forces (p = 0.001) and 240% higher cortical strains (p = 0.056). Cortex strains increased with varus alignment (R2 = 0.356, p = 0.011) while primary stability decreased with valgus stem alignment (p = 0.043). Surgeons should be aware that small deviations from the ideal stem size and malalignments of the stem can significantly alter the mechanical situation and affect the success of their surgery.


  • Open Access

    Influence of bone morphology and femur preparation method on the primary stability of hip revision stems

    by Tobias Konow, Peter J. Schlieker, Frank Lampe, Benjamin Ondruschka, Michael M. Morlock, Gerd Huber

    Aseptic loosening is one of the major reasons for re‐revisions of cementless revision stems. Insufficient primary stability is associated with bone characteristics and the surgical process. This study aimed to investigate how femur morphology and preparation methods influence the primary stability of revision stems. The Femur morphology was described by the upper femoral curvature (UFC) and an individualized Dorr type classification based on the ratio between the canal‐to‐calcar ratio (CCR*) and the cortical index (CI*) introduced as the cortical‐canal shape (CCS). Manual and powered reaming in combination with helical and straight reamers were used to prepare the bone cavity of 10 cadaveric human femur pairs. Forces during stem impaction were recorded (Reclaim, Depuy Synthes). Micromotion at the bone–implant interface during cyclic axial loading and torsional load to failure was determined. The CCS and impaction forces (R2 = 0.817, p < 0.001) or torsional strength (R2 = 0.577, p < 0.001) are inversely related. CCS did not correlate with micromotion during axial loading (R2 = 0.001, p > 0.999), but proximal femoral curvature did (R2 = 0.462, p = 0.015). Powered reaming and straight reamers led to an improved torsional strength (both: p = 0.043). The Individualized Dorr classification CCS and UFC allows a good estimation of the primary stability of revision stems. For severely curved Dorr type‐C femurs, an alternative anchorage method should be considered clinically.


  • Open Access

    Variability in Femoral Preparation and Implantation Between Surgeons Using Manual and Powered Impaction in Total Hip Arthroplasty

    by Tobias Konow, Johanna Bätz, David Beverland, Tim Board, Frank Lampe, Klaus Püschel, Michael M. Morlock