FNFrancesca Nesci

Francesca Nesci

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Francesca Nesci has a total of 12 co-authors. Here are the top co-authors by number of shared publications:

  • Alessio Merola

    Department of Experimental and Clinical Medicine Magna Græcia University of Catanzaro Catanzaro Italy

    4 shared publications
  • Carlo Cosentino

    School of Computer and Biomedical Engineering, Dipartimento di Medicina Sperimentale e Clinica, Universit degli Studi Magna Grcia di Catanzaro, Catanzaro, Italy

    4 shared publications
  • Donatella Dragone

    Biomechatronics Laboratory, Department of Experimental and Clinical Medicine, Università degli Studi Magna Græcia di Catanzaro, Campus Universitario “S. Venuta”, 88100 Catanzaro, Italy

    4 shared publications
  • Francesco Amato

    Department of Information Technology and Electrical Engineering, University of Naples Federico II, 80125 Naples, Italy

    4 shared publications
  • Alessia Capace

    Biomechatronics Laboratory, Department of Experimental and Clinical Medicine, Università degli Studi Magna Græcia di Catanzaro, Campus Universitario “S. Venuta”, 88100 Catanzaro, Italy

    2 shared publications
  • Luigi Randazzini

    Biomechatronics Laboratory, Department of Experimental and Clinical Medicine, Università degli Studi Magna Græcia di Catanzaro, Campus Universitario “S. Venuta”, 88100 Catanzaro, Italy

    2 shared publications

Latest Publications

  • Open Access

    Input–Output Finite‐Time Stability and Stabilization of Nonautonomous Nonlinear Quadratic Systems via State and Output Feedback

    by Alessio Merola, Francesca Nesci, Donatella Dragone, Francesco Montefusco, Francesco Amato, Carlo Cosentino

    This paper presents novel results regarding the input–output finite‐time stability (IO‐FTS) of nonlinear quadratic systems (NLQSs), a class of dynamical models particularly useful for the study of robotic systems, biochemical reaction networks, and other processes of interest to the applied sciences. After introducing the class of nonautonomous NLQSs, a sufficient condition ensuring the IO‐FTS of NLQSs, with time‐varying parameters and subject to input disturbances, represents the first main contribution. The analysis conditions are then exploited to develop state‐ and output‐feedback control laws that achieve IO finite‐time stabilization for an assigned NLQS. These sufficient conditions are expressed in terms of feasibility problems based on linear matrix inequalities (LMIs), which can be efficiently solved via off‐the‐shelf numerical tools. The applicability of the devised results is illustrated throughout the paper using examples of analysis and synthesis related to flight control systems described by NLQSs with time‐varying parameters.

  • Open Access

    Control of a three-wheeled omnidirectional mobile robot via a mixed FTB/$\mathcal H_\infty $ approach

    by Francesca Nesci, Francesco Amato, Donatella Dragone, Carlo Cosentino, Alessio Merola

    In this paper, the problem of guidance and motion control of mobile robots is addressed and solved within the novel framework of the mixed finite-time/ $$\mathcal H_\infty $$ H ∞ control theory of nonlinear quadratic systems (NLQSs). Starting from a NLQS describing the dynamics of omnidirectional mobile platforms, the main tasks performed for controlling in closed loop the motion of omnidirectional robots can be conveniently formulated as a mixed finite-time/ $$\mathcal H_\infty $$ H ∞ control problem. A robust motion controller, which can effectively rejects disturbances deviating the robot platform from a planned path, can be designed after choosing a linear state-feedback structure for the controller. The synthesis problem is solved through some sufficient conditions contemplating both norm-bounded disturbances and sets constraining initial and terminal conditions, together with a finite-time bound on the output transient. Therefore, for all the allowable uncertainties, in presence of nonzero initial conditions and exogenous disturbance inputs which are possible within an unstructured environment, the motion control tasks can be accomplished through optimal $$\mathcal H_\infty $$ H ∞ performance by simultaneously guaranteeing that the NLQS, which governs in closed loop the robot platform, is finite-time bounded. Finally, the applicability and control performance of the design approach have been evaluated through numerical simulations.

  • Design, testing and control of a smart haptic interface driven by 3D-printed soft pneumatic actuators for virtual reality-based hand rehabilitation

    by Donatella Dragone, Luigi Randazzini, Gianni Stano, Alessia Capace, Francesca Nesci, Carlo Cosentino, Francesco Amato, Roberto Colao, Gianluca Percoco, Alessio Merola

    This work presents the main steps of design and testing of a novel haptic interface and adaptive admittance control scheme for optimal regulation of the human–machine interaction in hand rehabilitation mediated by a smart system in virtual–reality environment. The prototype development is the result of an integrated HW/SW design and, moreover, the advantages from additive manufacturing techniques and mechanical properties of soft materials are exploited for the realization steps. Indeed, to make the interface smart, a network of piezo-resistive force sensors is embedded into the user’s command interface and the acquired signals are used for the adaptive regulation of human–machine interaction. Another distinctive feature of the haptic interface, which enables to identify this latter as a smart system, is the interaction control based on the estimation of the user’s intention within a novel scheme of adaptive admittance control. The enhanced training process in rehabilitation assisted by the haptic interface and virtual environment has been experimentally validated during a series of goal-directed tasks. The improvement of the motor performance of the user under the assistance of the adaptive admittance control has been experimentally evaluated. Further results show that the rehabilitation system supports the quantitative assessment of the robustness of the motor learning performance of the hand under the generation of haptic disturbances.


  • Open Access

    Design, Computational Modelling and Experimental Characterization of Bistable Hybrid Soft Actuators for a Controllable-Compliance Joint of an Exoskeleton Rehabilitation Robot

    by Donatella Dragone, Luigi Randazzini, Alessia Capace, Francesca Nesci, Carlo Cosentino, Francesco Amato, Elena De Momi, Roberto Colao, Lorenzo Masia, Alessio Merola

    This paper presents the mechatronic design of a biorobotic joint with controllable compliance, for innovative applications of “assist-as-needed” robotic rehabilitation mediated by a wearable and soft exoskeleton. The soft actuation of robotic exoskeletons can provide some relevant advantages in terms of controllable compliance, adaptivity and intrinsic safety of the control performance of the robot during the interaction with the patient. Pneumatic Artificial Muscles (PAMs), which belong to the class of soft actuators, can be arranged in antagonistic configuration in order to exploit the variability of their mechanical compliance for the optimal adaptation of the robot performance during therapy. The coupling of an antagonistic configuration of PAMs with a regulation mechanism can achieve, under a customized control strategy, the optimal tuning of the mechanical compliance of the exoskeleton joint over full ranges of actuation pressure and joint rotation. This work presents a novel mechanism, for the optimal regulation of the compliance of the biorobotic joint, which is characterized by a soft and hybrid actuation exploiting the storage/release of the elastic energy by bistable Von Mises elastic trusses. The contribution from elastic Von Mises structure can improve both the mechanical response of the soft pneumatic bellows actuating the regulation mechanism and the intrinsic safety of the whole mechanism. A comprehensive set of design steps is presented here, including the optimization of the geometry of the pneumatic bellows, the fabrication process through 3D printing of the mechanism and some experimental tests devoted to the characterization of the hybrid soft actuation. The experimental tests replicated the main operating conditions of the regulation mechanism; the advantages arising from the bistable hybrid soft actuation were evaluated in terms of static and dynamic performance, e.g., pressure and force transition thresholds of the bistable mechanism, linearity and hysteresis of the actuator response.