- Annegret Mündermann
Department of Biomedical Engineering, University of Basel, Basel, Switzerland
8 shared publications - Daniel Baumgartner
ZHAW School of Engineering, IMES Institute for Mechanical Systems, Winterthur, Switzerland
7 shared publications - Eleonora Croci
Department of Biomedical Engineering, University of Basel, Basel, Switzerland
7 shared publications - Andreas Marc Müller
Department of Biomedical Engineering, University of Basel, Basel, Switzerland
5 shared publications Andreas M. Müller
Univ Hosp Basel, Dept Orthopaed & Traumatol, Basel, Switzerland
4 shared publications- Balazs Krisztian Kovacs
Department of Radiology, University Hospital Basel, Basel, Switzerland
3 shared publications
Latest Publications
- Open Access
- 8 June 2024
- Published by Springer Nature in Journal of Orthopaedics and Traumatology
- Vol. 25 (1) , 1-11
Severity of rotator cuff disorders and additional load affect fluoroscopy-based shoulder kinematics during arm abduction
Background: Rotator cuff disorders, whether symptomatic or asymptomatic, may result in abnormal shoulder kinematics (scapular rotation and glenohumeral translation). This study aimed to investigate the effect of rotator cuff tears on in vivo shoulder kinematics during a 30° loaded abduction test using single-plane fluoroscopy. Materials and methods: In total, 25 younger controls, 25 older controls and 25 patients with unilateral symptomatic rotator cuff tears participated in this study. Both shoulders of each participant were analysed and grouped on the basis of magnetic resonance imaging into healthy, rotator cuff tendinopathy, asymptomatic and symptomatic rotator cuff tears. All participants performed a bilateral 30° arm abduction and adduction movement in the scapular plane with handheld weights (0, 2 and 4 kg) during fluoroscopy acquisition. The range of upward–downward scapular rotation and superior–inferior glenohumeral translation were measured and analysed during abduction and adduction using a linear mixed model (loads, shoulder types) with random effects (shoulder ID). Results: Scapular rotation was greater in shoulders with rotator cuff tendinopathy and asymptomatic rotator cuff tears than in healthy shoulders. Additional load increased upward during abduction and downward during adduction scapular rotation (P < 0.001 in all groups but rotator cuff tendinopathy). In healthy shoulders, upward scapular rotation during 30° abduction increased from 2.3° with 0-kg load to 4.1° with 4-kg load and on shoulders with symptomatic rotator cuff tears from 3.6° with 0-kg load to 6.5° with 4-kg load. Glenohumeral translation was influenced by the handheld weights only in shoulders with rotator cuff tendinopathy (P ≤ 0.020). Overall, superior glenohumeral translation during 30° abduction was approximately 1.0 mm with all loads. Conclusions: The results of glenohumeral translation comparable to control but greater scapular rotations during 30° abduction in the scapular plane in rotator cuff tears indicate that the scapula compensates for rotator cuff deficiency by rotating. Further analysis of load-dependent joint stability is needed to better understand glenohumeral and scapula motion. Level of evidence: Level 2. Trial registration: Ethical approval was obtained from the regional ethics committee (Ethics Committee Northwest Switzerland EKNZ 2021-00182), and the study was registered at clinicaltrials.gov on 29 March 2021 (trial registration number NCT04819724, https://clinicaltrials.gov/ct2/show/NCT04819724).
- 8 June 2024
- Published by Springer Nature in Journal of Orthopaedics and Traumatology
- Vol. 25 (1) , 1-11
Open AccessSeverity of rotator cuff disorders and additional load affect fluoroscopy-based shoulder kinematics during arm abduction
Background: Rotator cuff disorders, whether symptomatic or asymptomatic, may result in abnormal shoulder kinematics (scapular rotation and glenohumeral translation). This study aimed to investigate the effect of rotator cuff tears on in vivo shoulder kinematics during a 30° loaded abduction test using single-plane fluoroscopy. Materials and methods: In total, 25 younger controls, 25 older controls and 25 patients with unilateral symptomatic rotator cuff tears participated in this study. Both shoulders of each participant were analysed and grouped on the basis of magnetic resonance imaging into healthy, rotator cuff tendinopathy, asymptomatic and symptomatic rotator cuff tears. All participants performed a bilateral 30° arm abduction and adduction movement in the scapular plane with handheld weights (0, 2 and 4 kg) during fluoroscopy acquisition. The range of upward–downward scapular rotation and superior–inferior glenohumeral translation were measured and analysed during abduction and adduction using a linear mixed model (loads, shoulder types) with random effects (shoulder ID). Results: Scapular rotation was greater in shoulders with rotator cuff tendinopathy and asymptomatic rotator cuff tears than in healthy shoulders. Additional load increased upward during abduction and downward during adduction scapular rotation (P < 0.001 in all groups but rotator cuff tendinopathy). In healthy shoulders, upward scapular rotation during 30° abduction increased from 2.3° with 0-kg load to 4.1° with 4-kg load and on shoulders with symptomatic rotator cuff tears from 3.6° with 0-kg load to 6.5° with 4-kg load. Glenohumeral translation was influenced by the handheld weights only in shoulders with rotator cuff tendinopathy (P ≤ 0.020). Overall, superior glenohumeral translation during 30° abduction was approximately 1.0 mm with all loads. Conclusions: The results of glenohumeral translation comparable to control but greater scapular rotations during 30° abduction in the scapular plane in rotator cuff tears indicate that the scapula compensates for rotator cuff deficiency by rotating. Further analysis of load-dependent joint stability is needed to better understand glenohumeral and scapula motion. Level of evidence: Level 2. Trial registration: Ethical approval was obtained from the regional ethics committee (Ethics Committee Northwest Switzerland EKNZ 2021-00182), and the study was registered at clinicaltrials.gov on 29 March 2021 (trial registration number NCT04819724, https://clinicaltrials.gov/ct2/show/NCT04819724).
- Open Access
- 20 March 2024
- Published by Elsevier in Journal of Biomechanics
- Vol. 166, 112055
The influence of rotator cuff tear type and weight bearing on shoulder biomechanics in an ex vivo simulator experiment
- 20 March 2024
- Published by Elsevier in Journal of Biomechanics
- Vol. 166, 112055
Open AccessThe influence of rotator cuff tear type and weight bearing on shoulder biomechanics in an ex vivo simulator experiment
- Open Access
- 1 January 2024
- Published by Wiley in Applied Bionics and Biomechanics
- Vol. 2024 (1) , 4624007
Influence of Critical Shoulder Angle and Rotator Cuff Tear Type on Load‐Induced Glenohumeral Biomechanics: A Sawbone Simulator Study
Glenohumeral (GH) biomechanics after rotator cuff (RC) tears are not fully understood. The purpose of our study was to determine if the critical shoulder angle (CSA), type of RC tears, and level of weight bearing increase GH translation, instability based on the instability ratio, muscle forces and joint reaction force (JRF), and shifts the center of force (CoF) superiorly. A GH simulator with muscle‐mimicking cable systems was used to simulate 30° abduction in the scapular plane. A Sawbone humerus and five specimen‐specific scapular anthropometries were used to test six types of RC tears, three weight‐bearing loads, and the native and adjusted (to different CSAs) deltoid origin sites. Linear mixed effects models (CSA, RC tear type, and weight bearing) with random effects (specimen and sex) were used to assess differences in GH biomechanics. With increasing CSA, GH translation increased, JRF decreased, and the CoF position was more inferior. RC tears did not significantly alter GH translation but shifted the CoF position superiorly, close to where glenoid erosion occurs in patients with RC tears with secondary osteoarthritis. Weight bearing significantly increased GH translation and JRF. RC and deltoid muscle forces increased with the presence of RC tears and increased weight bearing. The remaining RC muscles of intact tendons compensated for the torn RC tendons but not for the altered CoF position. GH translation remained comparable to shoulders with intact RC. These findings highlight the importance of early detection, clinical management, and targeted rehabilitation strategies for patients with RC tears.
- 1 January 2024
- Published by Wiley in Applied Bionics and Biomechanics
- Vol. 2024 (1) , 4624007
Open AccessInfluence of Critical Shoulder Angle and Rotator Cuff Tear Type on Load‐Induced Glenohumeral Biomechanics: A Sawbone Simulator Study
Glenohumeral (GH) biomechanics after rotator cuff (RC) tears are not fully understood. The purpose of our study was to determine if the critical shoulder angle (CSA), type of RC tears, and level of weight bearing increase GH translation, instability based on the instability ratio, muscle forces and joint reaction force (JRF), and shifts the center of force (CoF) superiorly. A GH simulator with muscle‐mimicking cable systems was used to simulate 30° abduction in the scapular plane. A Sawbone humerus and five specimen‐specific scapular anthropometries were used to test six types of RC tears, three weight‐bearing loads, and the native and adjusted (to different CSAs) deltoid origin sites. Linear mixed effects models (CSA, RC tear type, and weight bearing) with random effects (specimen and sex) were used to assess differences in GH biomechanics. With increasing CSA, GH translation increased, JRF decreased, and the CoF position was more inferior. RC tears did not significantly alter GH translation but shifted the CoF position superiorly, close to where glenoid erosion occurs in patients with RC tears with secondary osteoarthritis. Weight bearing significantly increased GH translation and JRF. RC and deltoid muscle forces increased with the presence of RC tears and increased weight bearing. The remaining RC muscles of intact tendons compensated for the torn RC tendons but not for the altered CoF position. GH translation remained comparable to shoulders with intact RC. These findings highlight the importance of early detection, clinical management, and targeted rehabilitation strategies for patients with RC tears.
- Open Access
- 1 July 2023
- Published by Walter de Gruyter GmbH in at - Automatisierungstechnik
- Vol. 71 (7) , 505-514
Musculoskeletal model-based control strategy of an over-actuated glenohumeral simulator to assess joint biomechanics
Determining the acting shoulder and muscle forces in vivo is very complex. In this study, we developed a control strategy for a glenohumeral simulator for ex vivo experiments that can mimic physiological glenohumeral motion and overcome the problem of over-actuation. The system includes ten muscle portions actuated via cables to induce upper arm motion in three degrees of freedom, including scapula rotation. A real-time optimizer was implemented to handle the over-actuation of the glenohumeral joint while ensuring a minimum of muscle tension. The functionality of the real-time optimizer was also used to simulate different extents of rotator cuff tears. Joint reaction forces were consistent with in vivo measurements. These results demonstrate the feasibility and added value of implementing a real-time optimizer for using in vivo data to drive a shoulder simulator.
- 1 July 2023
- Published by Walter de Gruyter GmbH in at - Automatisierungstechnik
- Vol. 71 (7) , 505-514
Open AccessMusculoskeletal model-based control strategy of an over-actuated glenohumeral simulator to assess joint biomechanics
Determining the acting shoulder and muscle forces in vivo is very complex. In this study, we developed a control strategy for a glenohumeral simulator for ex vivo experiments that can mimic physiological glenohumeral motion and overcome the problem of over-actuation. The system includes ten muscle portions actuated via cables to induce upper arm motion in three degrees of freedom, including scapula rotation. A real-time optimizer was implemented to handle the over-actuation of the glenohumeral joint while ensuring a minimum of muscle tension. The functionality of the real-time optimizer was also used to simulate different extents of rotator cuff tears. Joint reaction forces were consistent with in vivo measurements. These results demonstrate the feasibility and added value of implementing a real-time optimizer for using in vivo data to drive a shoulder simulator.
- Open Access
- 28 May 2023
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 117 (1) , 104003
Ex vivo experimental strategies for assessing unconstrained shoulder biomechanics: A scoping review
Biomechanical studies of the shoulder often choose an ex vivo approach, especially when investigating the active and passive contribution of individual muscles. Although various simulators of the glenohumeral joint and its muscles have been developed, to date a testing standard has not been established. The objective of this scoping review was to present an overview of methodological and experimental studies describing ex vivo simulators that assess unconstrained, muscular driven shoulder biomechanics. All studies with ex vivo or mechanical simulation experiments using an unconstrained glenohumeral joint simulator and active components mimicking the muscles were included in this scoping review. Static experiments and humeral motion imposed through an external guide, e.g., a robotic device, were excluded. Nine different glenohumeral simulators were identified in 51 studies after the screening process. We identified four control strategies characterized by: (a) using a primary loader to determine the secondary loaders with constant force ratios; (b) using variable muscle force ratios according to electromyography; (c) calibrating the muscle path profile and control each motor according to this profile; or (d) using muscle optimization. The simulators with the control strategy (b) (n = 1) or (d) (n = 2) appear most promising due to its capability to mimic physiological muscle loads.
- 28 May 2023
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 117 (1) , 104003
Open AccessEx vivo experimental strategies for assessing unconstrained shoulder biomechanics: A scoping review
Biomechanical studies of the shoulder often choose an ex vivo approach, especially when investigating the active and passive contribution of individual muscles. Although various simulators of the glenohumeral joint and its muscles have been developed, to date a testing standard has not been established. The objective of this scoping review was to present an overview of methodological and experimental studies describing ex vivo simulators that assess unconstrained, muscular driven shoulder biomechanics. All studies with ex vivo or mechanical simulation experiments using an unconstrained glenohumeral joint simulator and active components mimicking the muscles were included in this scoping review. Static experiments and humeral motion imposed through an external guide, e.g., a robotic device, were excluded. Nine different glenohumeral simulators were identified in 51 studies after the screening process. We identified four control strategies characterized by: (a) using a primary loader to determine the secondary loaders with constant force ratios; (b) using variable muscle force ratios according to electromyography; (c) calibrating the muscle path profile and control each motor according to this profile; or (d) using muscle optimization. The simulators with the control strategy (b) (n = 1) or (d) (n = 2) appear most promising due to its capability to mimic physiological muscle loads.
- Open Access
- 23 December 2022
- Published by JMIR Publications Inc. in JMIR Research Protocols
- Vol. 11 (12) , e43769
Load-Induced Glenohumeral Translation After Rotator Cuff Tears: Protocol for an In Vivo Study
Background: Rotator cuff tears are a common shoulder injury, but they sometimes remain undiagnosed, as symptoms can be limited. Altered shoulder biomechanics can lead to secondary damage and degeneration. In biomechanical analyses, the shoulder (ie, the glenohumeral joint) is normally idealized as a ball-and-socket joint, even though a translation is often observed clinically. To date, no conclusive changes in glenohumeral translation have been reported in patients with rotator cuff tears, and it is unknown how an additional handheld weight that is comparable to those used during daily activities will affect glenohumeral translations in patients with rotator cuff tears. Objective: This study aims to assess the load-induced glenohumeral translation (liTr) in patients with rotator cuff tears and its association with the load-induced changes in muscle activation (liMA). Methods: Patients and asymptomatic controls will be recruited. Participants will fill out health questionnaires and perform 30° arm abduction and adduction trials, during which they will hold different handheld weights of a maximum of 4 kg while motion capture and electromyographic data are collected. In addition, fluoroscopic images of the shoulders will be taken for the same movements. Isometric shoulder muscle strength for abduction and rotation will be assessed with a dynamometer. Finally, shoulder magnetic resonance images will be acquired to assess muscle status and injury presence. The dose-response relationship between additional weight, liTr, and liMA will be evaluated. Results: Recruitment and data collection began in May 2021, and they will last until the recruitment target is achieved. Data collection is expected to be completed by the end of 2022. As of November 2022, data processing and analysis are in progress, and the first results are expected to be submitted for publication in 2023. Conclusions: This study will aid our understanding of biological variations in liTr, the influence of disease pathology on liTr, the potential compensation of rotator cuff tears by muscle activation and size, and the association between liTr and patient outcomes. The outcomes will be relevant for diagnosis, treatment, and rehabilitation planning in patients with rotator cuff tears. Trial Registration: ClinicalTrials.gov NCT04819724; https://clinicaltrials.gov/ct2/show/NCT04819724 International Registered Report Identifier (IRRID): DERR1-10.2196/43769
- 23 December 2022
- Published by JMIR Publications Inc. in JMIR Research Protocols
- Vol. 11 (12) , e43769
Open AccessLoad-Induced Glenohumeral Translation After Rotator Cuff Tears: Protocol for an In Vivo Study
Background: Rotator cuff tears are a common shoulder injury, but they sometimes remain undiagnosed, as symptoms can be limited. Altered shoulder biomechanics can lead to secondary damage and degeneration. In biomechanical analyses, the shoulder (ie, the glenohumeral joint) is normally idealized as a ball-and-socket joint, even though a translation is often observed clinically. To date, no conclusive changes in glenohumeral translation have been reported in patients with rotator cuff tears, and it is unknown how an additional handheld weight that is comparable to those used during daily activities will affect glenohumeral translations in patients with rotator cuff tears. Objective: This study aims to assess the load-induced glenohumeral translation (liTr) in patients with rotator cuff tears and its association with the load-induced changes in muscle activation (liMA). Methods: Patients and asymptomatic controls will be recruited. Participants will fill out health questionnaires and perform 30° arm abduction and adduction trials, during which they will hold different handheld weights of a maximum of 4 kg while motion capture and electromyographic data are collected. In addition, fluoroscopic images of the shoulders will be taken for the same movements. Isometric shoulder muscle strength for abduction and rotation will be assessed with a dynamometer. Finally, shoulder magnetic resonance images will be acquired to assess muscle status and injury presence. The dose-response relationship between additional weight, liTr, and liMA will be evaluated. Results: Recruitment and data collection began in May 2021, and they will last until the recruitment target is achieved. Data collection is expected to be completed by the end of 2022. As of November 2022, data processing and analysis are in progress, and the first results are expected to be submitted for publication in 2023. Conclusions: This study will aid our understanding of biological variations in liTr, the influence of disease pathology on liTr, the potential compensation of rotator cuff tears by muscle activation and size, and the association between liTr and patient outcomes. The outcomes will be relevant for diagnosis, treatment, and rehabilitation planning in patients with rotator cuff tears. Trial Registration: ClinicalTrials.gov NCT04819724; https://clinicaltrials.gov/ct2/show/NCT04819724 International Registered Report Identifier (IRRID): DERR1-10.2196/43769
- Open Access
- 24 October 2022
- Published by JMIR Publications Inc. in JMIR Preprints
Load-induced Glenohumeral Translation After Rotator Cuff Tears: Protocol of an In Vivo Study (Preprint)
BACKGROUND Rotator cuff tears are a common shoulder injury, yet they sometimes remain undiagnosed as symptoms can be limited. Altered shoulder biomechanics can lead to secondary damage and degeneration. In biomechanical analyses, the shoulder (i.e., the glenohumeral joint) is normally idealised as a ball and socket joint, even though a translation is often observed clinically. To date, no conclusive changes in glenohumeral translation have been reported in patients with rotator cuff tears, and it is unknown how an additional handheld weight comparable to those during daily activities will affect glenohumeral translations in patients with rotator cuff tears. OBJECTIVE This study aims to assess the load-induced glenohumeral translation (liTr) in patients with rotator cuff tears and its association with the load-induced changes in muscle activation (liMA). METHODS Patients and asymptomatic control subjects will be recruited. Participants will fill out health questionnaires and perform 30° arm abduction and adduction trials while holding different handheld weights of max. 4kg while motion capture and electromyographic data will be collected. In addition, fluoroscopic images of the shoulders will be taken for the same movements. Isometric shoulder muscle strength for abduction and rotation will be assessed with a dynamometer. Finally, shoulder magnetic resonance images will be acquired to assess muscle status and injury presence. The dose-response relationship between additional weight, liTr, and liMA will be evaluated. RESULTS Recruitment and data collection started in May 2021 and will last until the recruitment target is achieved. Data collection is expected to be completed by the end of 2022. Data processing and analysis is currently in progress, and the first results are expected to be submitted for publication in 2023. CONCLUSIONS This study will contribute to understanding the biological variation in liTr, the influence of disease pathology on liTr, the potential compensation of rotator cuff tears by muscle activation and size, and the association of liTr and patient outcomes. The outcomes will be relevant for diagnosis, treatment and rehabilitation planning in patients with rotator cuff tears. CLINICALTRIAL Ethical approval was granted by the regional ethics board (Ethics Committee Northwest Switzerland EKNZ 2021-00182), and the study was registered at clinicaltrials.gov (Trial registration number NCT04819724) on March 29, 2021.
- 24 October 2022
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessLoad-induced Glenohumeral Translation After Rotator Cuff Tears: Protocol of an In Vivo Study (Preprint)
BACKGROUND Rotator cuff tears are a common shoulder injury, yet they sometimes remain undiagnosed as symptoms can be limited. Altered shoulder biomechanics can lead to secondary damage and degeneration. In biomechanical analyses, the shoulder (i.e., the glenohumeral joint) is normally idealised as a ball and socket joint, even though a translation is often observed clinically. To date, no conclusive changes in glenohumeral translation have been reported in patients with rotator cuff tears, and it is unknown how an additional handheld weight comparable to those during daily activities will affect glenohumeral translations in patients with rotator cuff tears. OBJECTIVE This study aims to assess the load-induced glenohumeral translation (liTr) in patients with rotator cuff tears and its association with the load-induced changes in muscle activation (liMA). METHODS Patients and asymptomatic control subjects will be recruited. Participants will fill out health questionnaires and perform 30° arm abduction and adduction trials while holding different handheld weights of max. 4kg while motion capture and electromyographic data will be collected. In addition, fluoroscopic images of the shoulders will be taken for the same movements. Isometric shoulder muscle strength for abduction and rotation will be assessed with a dynamometer. Finally, shoulder magnetic resonance images will be acquired to assess muscle status and injury presence. The dose-response relationship between additional weight, liTr, and liMA will be evaluated. RESULTS Recruitment and data collection started in May 2021 and will last until the recruitment target is achieved. Data collection is expected to be completed by the end of 2022. Data processing and analysis is currently in progress, and the first results are expected to be submitted for publication in 2023. CONCLUSIONS This study will contribute to understanding the biological variation in liTr, the influence of disease pathology on liTr, the potential compensation of rotator cuff tears by muscle activation and size, and the association of liTr and patient outcomes. The outcomes will be relevant for diagnosis, treatment and rehabilitation planning in patients with rotator cuff tears. CLINICALTRIAL Ethical approval was granted by the regional ethics board (Ethics Committee Northwest Switzerland EKNZ 2021-00182), and the study was registered at clinicaltrials.gov (Trial registration number NCT04819724) on March 29, 2021.
- Open Access
- 8 March 2022
- Published by F1000 Research Ltd in F1000Research
- Vol. 11, 77
Ex-vivo experimental strategies for assessing unconstrained shoulder biomechanics: a scoping review protocol
Background: Shoulder biomechanics cannot be measured directly in living persons. While different glenohumeral joint simulators have been developed to investigate the role of the glenohumeral muscles in shoulder biomechanics, a standard for these simulators has not been defined. With this scoping review we want to describe available ex-vivo experimental strategies for assessing unconstrained shoulder biomechanics. Objective: The scoping review aims at identifying methodological and/or experimental studies describing or involving ex-vivo simulators that assess unconstrained shoulder biomechanics and synthesizing their strengths and limitations. Inclusion criteria: All unconstrained glenohumeral joint simulators published in connection with ex-vivo or mechanical simulation experiments will be included. Studies on glenohumeral simulators with active components to mimic the muscles will be included. We will exclude studies where the experiment is static or the motion is induced through an external guide, e.g., a robotic device. Methods: We will perform database searching in PubMed, Embase via Elsevier and Web of Science. Two reviewers will independently assess full texts of selected abstracts. Direct backward and forward citation tracking on included articles will be conducted. We will narratively synthesize the results and derive recommendations for designing ex-vivo simulators for assessing unconstrained shoulder biomechanics.
- 8 March 2022
- Published by F1000 Research Ltd in F1000Research
- Vol. 11, 77
Open AccessEx-vivo experimental strategies for assessing unconstrained shoulder biomechanics: a scoping review protocol
Background: Shoulder biomechanics cannot be measured directly in living persons. While different glenohumeral joint simulators have been developed to investigate the role of the glenohumeral muscles in shoulder biomechanics, a standard for these simulators has not been defined. With this scoping review we want to describe available ex-vivo experimental strategies for assessing unconstrained shoulder biomechanics. Objective: The scoping review aims at identifying methodological and/or experimental studies describing or involving ex-vivo simulators that assess unconstrained shoulder biomechanics and synthesizing their strengths and limitations. Inclusion criteria: All unconstrained glenohumeral joint simulators published in connection with ex-vivo or mechanical simulation experiments will be included. Studies on glenohumeral simulators with active components to mimic the muscles will be included. We will exclude studies where the experiment is static or the motion is induced through an external guide, e.g., a robotic device. Methods: We will perform database searching in PubMed, Embase via Elsevier and Web of Science. Two reviewers will independently assess full texts of selected abstracts. Direct backward and forward citation tracking on included articles will be conducted. We will narratively synthesize the results and derive recommendations for designing ex-vivo simulators for assessing unconstrained shoulder biomechanics.
- Open Access
- 21 January 2022
- Published by F1000 Research Ltd in F1000Research
- Vol. 11, 77
Ex-vivo experimental strategies for assessing unconstrained shoulder biomechanics: a scoping review protocol
Background: Shoulder biomechanics cannot be measured directly in living persons. While different glenohumeral joint simulators have been developed to investigate the role of the glenohumeral muscles in shoulder biomechanics, a standard for these simulators has not been defined. With this scoping review we want to describe available ex-vivo experimental strategies for assessing unconstrained shoulder biomechanics. Objective: The scoping review aims at identifying methodological and/or experimental studies describing or involving ex-vivo simulators that assess unconstrained shoulder biomechanics and synthesizing their strengths and limitations. Inclusion criteria: All unconstrained glenohumeral joint simulators published in connection with ex-vivo or mechanical simulation experiments will be included. Studies on glenohumeral simulators with active components to mimic the muscles will be included. We will exclude studies where the experiment is static or the motion is induced through an external guide, e.g., a robotic device. Methods: We will perform database searching in PubMed, Embase via Elsevier and Web of Science. Two reviewers will independently assess full texts of selected abstracts. Direct backward and forward citation tracking on included articles will be conducted. We will narratively synthesize the results and derive recommendations for designing ex-vivo simulators for assessing unconstrained shoulder biomechanics.
- 21 January 2022
- Published by F1000 Research Ltd in F1000Research
- Vol. 11, 77
Open AccessEx-vivo experimental strategies for assessing unconstrained shoulder biomechanics: a scoping review protocol
Background: Shoulder biomechanics cannot be measured directly in living persons. While different glenohumeral joint simulators have been developed to investigate the role of the glenohumeral muscles in shoulder biomechanics, a standard for these simulators has not been defined. With this scoping review we want to describe available ex-vivo experimental strategies for assessing unconstrained shoulder biomechanics. Objective: The scoping review aims at identifying methodological and/or experimental studies describing or involving ex-vivo simulators that assess unconstrained shoulder biomechanics and synthesizing their strengths and limitations. Inclusion criteria: All unconstrained glenohumeral joint simulators published in connection with ex-vivo or mechanical simulation experiments will be included. Studies on glenohumeral simulators with active components to mimic the muscles will be included. We will exclude studies where the experiment is static or the motion is induced through an external guide, e.g., a robotic device. Methods: We will perform database searching in PubMed, Embase via Elsevier and Web of Science. Two reviewers will independently assess full texts of selected abstracts. Direct backward and forward citation tracking on included articles will be conducted. We will narratively synthesize the results and derive recommendations for designing ex-vivo simulators for assessing unconstrained shoulder biomechanics.