Jun Liao
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jun Liao has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Guoan Zheng
University of Connecticut
2 shared publications - Zibang Zhang
Department of Optoelectronic Engineering, Jinan University, Guangzhou 510632, China
2 shared publications Ge Ding
Tencent AI Lab
1 shared publicationHan Wang
Tencent AI Lab
1 shared publicationHu Ye
Tencent AI Lab
1 shared publication- Jianhua Yao
AI for Life Sciences Lab, Tencent, Shenzhen, China
1 shared publication
Latest Publications
- 3 April 2023
- Published by Optica Publishing Group in Optics Letters
- Vol. 48 (8) , 1970-1973
Image-free active autofocusing with dual modulation and its application to Fourier single-pixel imaging
Autofocusing is widely used in applications where sharp image acquisition or projection is needed. Here we report an active autofocusing method for sharp image projection. The method works with wide-field structured illumination and single-pixel detection. To find the focus position, the method illuminates the target object with a set of 3-step phase-shifting Fourier basis patterns repeatedly and collects the backscattered light by using a single-pixel detector through a grating. Dual modulation—dynamic modulation by the time-varying structured illumination and static modulation by the grating—embeds the depth information for the target object in the resulting single-pixel measurements. As such, the focus position can be determined by recovering the Fourier coefficients from the single-pixel measurements and searching for the coefficient with the maximum magnitude. High-speed spatial light modulation not only enables rapid autofocusing but also makes the method work even when the lens system is in continuous motion or the focal length of the lens is continuously adjusted. We experimentally validate the reported method in a self-built digital projector and demonstrate the application of the method in Fourier single-pixel imaging.
- 3 April 2023
- Published by Optica Publishing Group in Optics Letters
- Vol. 48 (8) , 1970-1973
Image-free active autofocusing with dual modulation and its application to Fourier single-pixel imaging
Autofocusing is widely used in applications where sharp image acquisition or projection is needed. Here we report an active autofocusing method for sharp image projection. The method works with wide-field structured illumination and single-pixel detection. To find the focus position, the method illuminates the target object with a set of 3-step phase-shifting Fourier basis patterns repeatedly and collects the backscattered light by using a single-pixel detector through a grating. Dual modulation—dynamic modulation by the time-varying structured illumination and static modulation by the grating—embeds the depth information for the target object in the resulting single-pixel measurements. As such, the focus position can be determined by recovering the Fourier coefficients from the single-pixel measurements and searching for the coefficient with the maximum magnitude. High-speed spatial light modulation not only enables rapid autofocusing but also makes the method work even when the lens system is in continuous motion or the focal length of the lens is continuously adjusted. We experimentally validate the reported method in a self-built digital projector and demonstrate the application of the method in Fourier single-pixel imaging.
- 14 December 2021
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (1) , 314-327
Deep learning-based single-shot autofocus method for digital microscopy
Digital pathology is being transformed by artificial intelligence (AI)-based pathological diagnosis. One major challenge for correct AI diagnoses is to ensure the focus quality of captured images. Here, we propose a deep learning-based single-shot autofocus method for microscopy. We use a modified MobileNetV3, a lightweight network, to predict the defocus distance with a single-shot microscopy image acquired at an arbitrary image plane without secondary camera or additional optics. The defocus prediction takes only 9 ms with a focusing error of only ∼1/15 depth of field. We also provide implementation examples for the augmented reality microscope and the whole slide imaging (WSI) system. Our proposed technique can perform real-time and accurate autofocus which will not only support pathologists in their daily work, but also provide potential applications in the life sciences, material research, and industrial automatic detection.
- 14 December 2021
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (1) , 314-327
Deep learning-based single-shot autofocus method for digital microscopy
Digital pathology is being transformed by artificial intelligence (AI)-based pathological diagnosis. One major challenge for correct AI diagnoses is to ensure the focus quality of captured images. Here, we propose a deep learning-based single-shot autofocus method for microscopy. We use a modified MobileNetV3, a lightweight network, to predict the defocus distance with a single-shot microscopy image acquired at an arbitrary image plane without secondary camera or additional optics. The defocus prediction takes only 9 ms with a focusing error of only ∼1/15 depth of field. We also provide implementation examples for the augmented reality microscope and the whole slide imaging (WSI) system. Our proposed technique can perform real-time and accurate autofocus which will not only support pathologists in their daily work, but also provide potential applications in the life sciences, material research, and industrial automatic detection.
- 29 June 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 23 (06) , 066503-7
Terapixel hyperspectral whole-slide imaging via slit-array detection and projection
Digital pathology via whole-slide imaging (WSI) systems has recently been approved for the primary diagnostic use in the US. Acquiring whole-slide images with spectral information at each pixel permits the use of multiplexed antibody labeling and allow for the measurement of cellularly resolved chemical information. Here, we report the development of a high-throughput terapixel hyperspectral WSI system using prism-based slit-array dispersion. We demonstrate a slit-array detection scheme for absorption-based measurements and a slit-array projection scheme for fluorescence-based measurements. The spectral resolution and spectral range in the reported schemes can be adjusted by changing the orientation of the slit-array mask. We use our system to acquire 74 5-megapixel brightfield images at different wavelengths in ∼1 s, corresponding to a throughput of 0.375 gigapixels / s. A terapixel whole-slide spatial–spectral data cube can be obtained in ∼45 min. The reported system is compatible with existing WSI systems and can be developed as an add-on module for whole-slide spectral imaging. It may find broad applications in high-throughput chemical imaging with multiple antibody labeling. The use of slit array for structured illumination may also provide insights for developing high-throughput hyperspectral confocal imaging systems.
- 29 June 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 23 (06) , 066503-7
Terapixel hyperspectral whole-slide imaging via slit-array detection and projection
Digital pathology via whole-slide imaging (WSI) systems has recently been approved for the primary diagnostic use in the US. Acquiring whole-slide images with spectral information at each pixel permits the use of multiplexed antibody labeling and allow for the measurement of cellularly resolved chemical information. Here, we report the development of a high-throughput terapixel hyperspectral WSI system using prism-based slit-array dispersion. We demonstrate a slit-array detection scheme for absorption-based measurements and a slit-array projection scheme for fluorescence-based measurements. The spectral resolution and spectral range in the reported schemes can be adjusted by changing the orientation of the slit-array mask. We use our system to acquire 74 5-megapixel brightfield images at different wavelengths in ∼1 s, corresponding to a throughput of 0.375 gigapixels / s. A terapixel whole-slide spatial–spectral data cube can be obtained in ∼45 min. The reported system is compatible with existing WSI systems and can be developed as an add-on module for whole-slide spectral imaging. It may find broad applications in high-throughput chemical imaging with multiple antibody labeling. The use of slit array for structured illumination may also provide insights for developing high-throughput hyperspectral confocal imaging systems.