Ayham AlAkhras
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ayham AlAkhras has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Julie Nantel
School of Human Kinetics, University of Ottawa, Ottawa, Canada
2 shared publications Edward D. Lemaire
Faculty of Medicine University of Ottawa Ottawa ON Canada
1 shared publication- Edward D. Lemaire
Faculty of Medicine, University of Ottawa, Ottawa, Ontario, Canada
1 shared publication Ensieh Jafari
School of Human Kinetics, Faculty of Health Sciences University of Ottawa Ottawa ON Canada
1 shared publication- Ensieh Jafari
School of Human Kinetics, Faculty of Health Sciences, University of Ottawa, Ottawa, ON K1N 6N5, Canada
1 shared publication - Ilham Hassan Sattar
Department of Mechanical Engineering, American University of Sharjah, Sharjah 26666, United Arab Emirates
1 shared publication
Latest Publications
- Open Access
- 22 July 2026
- Published by Wiley in European Journal of Neuroscience
- Vol. 64 (2) , e70633
Feasibility of Real‐Time Autonomous Functional Electrical Stimulation for Freezing of Gait
Freezing of gait is a debilitating walking disturbance that can severely worsen quality of life for people with Parkinson's disease. However, current Parkinson's disease treatments do not effectively address freezing of gait, leading researchers to explore cueing to mitigate the symptom. Somatosensory stimulation is an emerging cueing strategy that could be discreet and practical to mitigate freezing of gait duration. Twenty‐six participants (seven females) attempted walking trials in a freeze‐inducing path while wearing a functional electrical stimulation cueing device. Functional electrical stimulation cueing was activated autonomously in real time. Constrained random sampling was used to designate each trial as cueing system on or off, providing a control for within‐participant analysis. A total of 576 freezing episodes were recorded with the device on. Of those, 492 were successfully stimulated. To assess cueing performance, freezing of gait time per trial in the on and off device states was calculated for each participant. On average, freezing of gait time per trial decreased from 5.84 to 5.69 s (2.44%). Freezing of gait time per trial increased for half the participants and the other half experienced a decrease. There were no statistically significant group‐level effects, though electrical stimulation cueing elicits a wide range of responses from different participants, with the technology mitigating freezing of gait for some individuals. Because functional electrical stimulation has numerous modifiable parameters that influence sensation and nervous system response, personalizing these parameters could enhance the effectiveness of freezing of gait mitigation and provide deeper insights into freezing of gait.
- 22 July 2026
- Published by Wiley in European Journal of Neuroscience
- Vol. 64 (2) , e70633
Open AccessFeasibility of Real‐Time Autonomous Functional Electrical Stimulation for Freezing of Gait
Freezing of gait is a debilitating walking disturbance that can severely worsen quality of life for people with Parkinson's disease. However, current Parkinson's disease treatments do not effectively address freezing of gait, leading researchers to explore cueing to mitigate the symptom. Somatosensory stimulation is an emerging cueing strategy that could be discreet and practical to mitigate freezing of gait duration. Twenty‐six participants (seven females) attempted walking trials in a freeze‐inducing path while wearing a functional electrical stimulation cueing device. Functional electrical stimulation cueing was activated autonomously in real time. Constrained random sampling was used to designate each trial as cueing system on or off, providing a control for within‐participant analysis. A total of 576 freezing episodes were recorded with the device on. Of those, 492 were successfully stimulated. To assess cueing performance, freezing of gait time per trial in the on and off device states was calculated for each participant. On average, freezing of gait time per trial decreased from 5.84 to 5.69 s (2.44%). Freezing of gait time per trial increased for half the participants and the other half experienced a decrease. There were no statistically significant group‐level effects, though electrical stimulation cueing elicits a wide range of responses from different participants, with the technology mitigating freezing of gait for some individuals. Because functional electrical stimulation has numerous modifiable parameters that influence sensation and nervous system response, personalizing these parameters could enhance the effectiveness of freezing of gait mitigation and provide deeper insights into freezing of gait.
- Open Access
Real-Time Freezing of Gait Prediction and Detection in Parkinson’s Disease
Freezing of gait (FOG) is a walking disturbance that can lead to postural instability, falling, and decreased mobility in people with Parkinson’s disease. This research used machine learning to predict and detect FOG episodes from plantar-pressure data and compared the performance of decision tree ensemble classifiers when trained on three different datasets. Dataset 1 (n = 11) was collected in a previous study. Dataset 2 (n = 10) included six new participants and four participants from Dataset 1 who were re-tested (approximately 2 years later), and Dataset 3 (n = 21) combined Datasets 1 and 2. The prediction model trained on Dataset 3 had a 2.28% higher sensitivity and 3.09% lower specificity compared to the models trained on Dataset 1. The model trained on Dataset 3 identified 86.84% of the total FOG episodes compared to 74.31% from the model trained on Dataset 1. Also, the model using Dataset 3 identified the FOG episodes 0.3 s earlier than the model developed with Dataset 1. The model trained using Dataset 3 showed improved performance in sensitivity, identification time, and FOG identification. The improvements using the expanded dataset (Dataset 3) in this study compared to the previous model reinforce the validity and generalizability of the original model. The model was able to predict and detect FOG well and is, therefore, ready to be implemented in a FOG prevention device.
Open AccessReal-Time Freezing of Gait Prediction and Detection in Parkinson’s Disease
Freezing of gait (FOG) is a walking disturbance that can lead to postural instability, falling, and decreased mobility in people with Parkinson’s disease. This research used machine learning to predict and detect FOG episodes from plantar-pressure data and compared the performance of decision tree ensemble classifiers when trained on three different datasets. Dataset 1 (n = 11) was collected in a previous study. Dataset 2 (n = 10) included six new participants and four participants from Dataset 1 who were re-tested (approximately 2 years later), and Dataset 3 (n = 21) combined Datasets 1 and 2. The prediction model trained on Dataset 3 had a 2.28% higher sensitivity and 3.09% lower specificity compared to the models trained on Dataset 1. The model trained on Dataset 3 identified 86.84% of the total FOG episodes compared to 74.31% from the model trained on Dataset 1. Also, the model using Dataset 3 identified the FOG episodes 0.3 s earlier than the model developed with Dataset 1. The model trained using Dataset 3 showed improved performance in sensitivity, identification time, and FOG identification. The improvements using the expanded dataset (Dataset 3) in this study compared to the previous model reinforce the validity and generalizability of the original model. The model was able to predict and detect FOG well and is, therefore, ready to be implemented in a FOG prevention device.
- Open Access
- 23 January 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (3) , 1173
The Design of a Lightweight Cable Aerial Manipulator with a CoG Compensation Mechanism for Construction Inspection Purposes
Conventionally, aerial manipulators, when used for inspection, use drone rotors to stabilize the center of gravity (CoG) shifts, which highly affects its performance. This paper discusses the development of a self-balancing lightweight cable aerial manipulator that can be used for construction inspection purposes. The design is based on a 3D-printed, three degrees of freedom (DoF), planar cable manipulator that is mounted on an extended platform below it as a counter-balance mechanism. The actuators control the manipulator links through a cable system, allowing them to be mounted at the system base to reduce the moving mass of the manipulator during operation. The counter-balance mechanism compensates for any shifts in the CoG of the system by actively sliding a counter-balance weight, mainly a battery, which powers the setup. This mechanism can be attached beneath an off-the-shelf quadrotor to solve the problem of CoG shifts. CoG shifts are due to the manipulator operation when a payload or inspection tool is attached to the end effector to perform a given task. For construction integrity inspection, the aerial manipulator must remain stable during the push or slide processes on both flat and curved surfaces while the non-destructive tests are carried out. To validate the effectiveness of the proposed design, an experimental setup was used, and comparisons were made between the compensated and uncompensated tilt angles of the aerial manipulator. Significant tilt angle reductions were observed with an average of 94.69% improvement, undergoing different manipulator motions during different operation scenarios, as a result of an active compensation of the CoG shift and lightweight design of the system, without sacrificing the functionality of the manipulator for the task.
- 23 January 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (3) , 1173
Open AccessThe Design of a Lightweight Cable Aerial Manipulator with a CoG Compensation Mechanism for Construction Inspection Purposes
Conventionally, aerial manipulators, when used for inspection, use drone rotors to stabilize the center of gravity (CoG) shifts, which highly affects its performance. This paper discusses the development of a self-balancing lightweight cable aerial manipulator that can be used for construction inspection purposes. The design is based on a 3D-printed, three degrees of freedom (DoF), planar cable manipulator that is mounted on an extended platform below it as a counter-balance mechanism. The actuators control the manipulator links through a cable system, allowing them to be mounted at the system base to reduce the moving mass of the manipulator during operation. The counter-balance mechanism compensates for any shifts in the CoG of the system by actively sliding a counter-balance weight, mainly a battery, which powers the setup. This mechanism can be attached beneath an off-the-shelf quadrotor to solve the problem of CoG shifts. CoG shifts are due to the manipulator operation when a payload or inspection tool is attached to the end effector to perform a given task. For construction integrity inspection, the aerial manipulator must remain stable during the push or slide processes on both flat and curved surfaces while the non-destructive tests are carried out. To validate the effectiveness of the proposed design, an experimental setup was used, and comparisons were made between the compensated and uncompensated tilt angles of the aerial manipulator. Significant tilt angle reductions were observed with an average of 94.69% improvement, undergoing different manipulator motions during different operation scenarios, as a result of an active compensation of the CoG shift and lightweight design of the system, without sacrificing the functionality of the manipulator for the task.