Jianyuan Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jianyuan Wang has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Menglun Zhang
State Key Laboratory of Precision Measuring Technology & Instruments, Tianjin University, Tianjin 300072, China
4 shared publications - Sheng Sun
State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin, China
3 shared publications Wei Pang
State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin, China
3 shared publications- Yuan Ning
State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin, China
3 shared publications Dong Ma
Department of Computer Science and Technology, University of Cambridge, Cambridge, UK
2 shared publicationsXiaopeng Yang
State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin, China
2 shared publications
Latest Publications
- 22 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (21) , 20285-20292
MEMS Ultrasonic Fingertip Heart Rate Sensor
The heartbeat is one of the main human physiological activities and is closely related to psychological and physiological states. Since limited solutions exist for convenient heart rate measurements at the fingertip, such as photoplethysmography, this paper provides an alternative solution enabled by a piezoelectric micromachined ultrasonic transducer (PMUT). With fingertip vascular expansion and retraction, the change in ultrasound time-of-flight (TOF) between the PMUT and phalanx is used to extract heart rate data. A PMUT with a resonant frequency of 4.3 MHz is designed and fabricated as a 25 by 25 array of elements, and Parylene and polydimethylsiloxane (PDMS) are used for packaging and better coupling with fingertips, respectively. The emitting ultrasound has a spatial-peak temporal average power density of 36 nW/mm2, far below the FDA safety limit. The proposed solution paves the way for ultrasound-based heart rate monitoring at the fingertip, and it features convenient use, easy integration and biosafety.
- 22 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (21) , 20285-20292
MEMS Ultrasonic Fingertip Heart Rate Sensor
The heartbeat is one of the main human physiological activities and is closely related to psychological and physiological states. Since limited solutions exist for convenient heart rate measurements at the fingertip, such as photoplethysmography, this paper provides an alternative solution enabled by a piezoelectric micromachined ultrasonic transducer (PMUT). With fingertip vascular expansion and retraction, the change in ultrasound time-of-flight (TOF) between the PMUT and phalanx is used to extract heart rate data. A PMUT with a resonant frequency of 4.3 MHz is designed and fabricated as a 25 by 25 array of elements, and Parylene and polydimethylsiloxane (PDMS) are used for packaging and better coupling with fingertips, respectively. The emitting ultrasound has a spatial-peak temporal average power density of 36 nW/mm2, far below the FDA safety limit. The proposed solution paves the way for ultrasound-based heart rate monitoring at the fingertip, and it features convenient use, easy integration and biosafety.
- Open Access
- 13 June 2022
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 8 (1) , 1-14
MEMS ultrasonic transducers for safe, low-power and portable eye-blinking monitoring
Eye blinking is closely related to human physiology and psychology. It is an effective method of communication among people and can be used in human–machine interactions. Existing blink monitoring methods include video-oculography, electro-oculograms and infrared oculography. However, these methods suffer from uncomfortable use, safety risks, limited reliability in strong light or dark environments, and infringed informational security. In this paper, we propose an ultrasound-based portable approach for eye-blinking activity monitoring. Low-power pulse-echo ultrasound featuring biosafety is transmitted and received by microelectromechanical system (MEMS) ultrasonic transducers seamlessly integrated on glasses. The size, weight and power consumption of the transducers are 2.5 mm by 2.5 mm, 23.3 mg and 71 μW, respectively, which provides better portability than conventional methods using wearable devices. Eye-blinking activities were characterized by open and closed eye states and validated by experiments on different volunteers. Finally, real-time eye-blinking monitoring was successfully demonstrated with a response time less than 1 ms. The proposed solution paves the way for ultrasound-based wearable eye-blinking monitoring and offers miniaturization, light weight, low power consumption, high informational security and biosafety.
- 13 June 2022
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 8 (1) , 1-14
Open AccessMEMS ultrasonic transducers for safe, low-power and portable eye-blinking monitoring
Eye blinking is closely related to human physiology and psychology. It is an effective method of communication among people and can be used in human–machine interactions. Existing blink monitoring methods include video-oculography, electro-oculograms and infrared oculography. However, these methods suffer from uncomfortable use, safety risks, limited reliability in strong light or dark environments, and infringed informational security. In this paper, we propose an ultrasound-based portable approach for eye-blinking activity monitoring. Low-power pulse-echo ultrasound featuring biosafety is transmitted and received by microelectromechanical system (MEMS) ultrasonic transducers seamlessly integrated on glasses. The size, weight and power consumption of the transducers are 2.5 mm by 2.5 mm, 23.3 mg and 71 μW, respectively, which provides better portability than conventional methods using wearable devices. Eye-blinking activities were characterized by open and closed eye states and validated by experiments on different volunteers. Finally, real-time eye-blinking monitoring was successfully demonstrated with a response time less than 1 ms. The proposed solution paves the way for ultrasound-based wearable eye-blinking monitoring and offers miniaturization, light weight, low power consumption, high informational security and biosafety.
- 26 May 2022
- Published by Science China Press., Co. Ltd. in SCIENTIA SINICA Technologica
- Vol. 53 (3) , 353-362
Ultrasonic solidification and microstructural evolution of binary Al-12.6%Si eutectic alloy
在三维高强超声场中实现了二元Al-12.6%Si共晶合金的动态凝固过程,探索了其组织演变机制。结果表明,静态凝固条件下形成典型的共晶组织,其中(Si)相呈不规则薄片状,而α(Al)相为枝晶状。三维超声作用下,空化引起熔体过冷和声流改变温度场和溶质场的分布特征,使两共晶相独立形核、各向同性长大,从而形成由块状(Si)相和球状α(Al)相组成的离异共晶组织。超声的高频振动效应增加了(Si)相的孪晶生长几率,导致大量交错孪晶(Si)相产生。由于超声降低了两相之间的界面能,共晶组织平行生长取向程度升高,同时其显微硬度显著提高。
- 26 May 2022
- Published by Science China Press., Co. Ltd. in SCIENTIA SINICA Technologica
- Vol. 53 (3) , 353-362
Ultrasonic solidification and microstructural evolution of binary Al-12.6%Si eutectic alloy
在三维高强超声场中实现了二元Al-12.6%Si共晶合金的动态凝固过程,探索了其组织演变机制。结果表明,静态凝固条件下形成典型的共晶组织,其中(Si)相呈不规则薄片状,而α(Al)相为枝晶状。三维超声作用下,空化引起熔体过冷和声流改变温度场和溶质场的分布特征,使两共晶相独立形核、各向同性长大,从而形成由块状(Si)相和球状α(Al)相组成的离异共晶组织。超声的高频振动效应增加了(Si)相的孪晶生长几率,导致大量交错孪晶(Si)相产生。由于超声降低了两相之间的界面能,共晶组织平行生长取向程度升高,同时其显微硬度显著提高。
- 31 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (4) , 1469-1477
An Ultra-Low Power, Small Size and High Precision Indoor Localization System Based on MEMS Ultrasonic Transducer Chips
The development of Internet of Things (IoT) requires demanding accurate and low-power indoor localization. In this article, a high-precision 3-D ultrasonic indoor localization system with ultralow power is proposed. A new piezoelectric micromachined ultrasonic transducer (PMUT) chip with a slotted membrane is designed and fabricated as a receiver, breaking the dilemma of low resonant frequency and wide field of view required for indoor localization. The system works based on the time difference of arrival (TDoA), and an improved quantum genetic algorithm (QGA) is used to estimate the location. The results show that the system achieves centimeter-level positioning precision, which is among the best solutions nowadays. Due to the high performance and small size endowed by the PMUT, the receiver footprint reaches as small as 0.25 cm 2 and power consumption could reach as low as 0.1 mW, which are far better than that of current indoor localization systems.
- 31 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (4) , 1469-1477
An Ultra-Low Power, Small Size and High Precision Indoor Localization System Based on MEMS Ultrasonic Transducer Chips
The development of Internet of Things (IoT) requires demanding accurate and low-power indoor localization. In this article, a high-precision 3-D ultrasonic indoor localization system with ultralow power is proposed. A new piezoelectric micromachined ultrasonic transducer (PMUT) chip with a slotted membrane is designed and fabricated as a receiver, breaking the dilemma of low resonant frequency and wide field of view required for indoor localization. The system works based on the time difference of arrival (TDoA), and an improved quantum genetic algorithm (QGA) is used to estimate the location. The results show that the system achieves centimeter-level positioning precision, which is among the best solutions nowadays. Due to the high performance and small size endowed by the PMUT, the receiver footprint reaches as small as 0.25 cm 2 and power consumption could reach as low as 0.1 mW, which are far better than that of current indoor localization systems.
- 15 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 31 (1) , 45-53
Eye-Tracking Monitoring Based on PMUT Arrays
As $a$ common and natural activity of human beings, eye movement has been regarded as an indicator of human physiological and psychological health; eye movement tracking has been applied to $a$ wide range of domains, such as disease diagnostics, drug therapy testing and human-computer interaction. Conventionally, eye movement is captured by three approaches, i.e., recording video using $a$ camera, measuring time-varying Electrooculography (EOG) signals using electrodes, and detecting reflected infrared light using infrared sensor. However, all these techniques incur certain limitations that impede their adoption for practical eye tracking, such as privacy violation, high computation resources, discomfort and strong light reliability. This paper presents $a$ portable and robust eye tracking technique based on ultrasound. Specifically, piezoelectric MEMS ultrasonic transducer arrays integrated on glasses are used to transmit and receive bio-safe pulse echo ultrasound individually. With experiment on volunteers, the developed devices can accurately track the rotation and direction of eyeball movement in real-time, based on the time of flight (TOF) principle. The tracking device is lightweight (< 25 mg) and compact (millimeters in size), showing $a$ great potential for wearable eye tracking application like virtual reality. [2021-0193]
- 15 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 31 (1) , 45-53
Eye-Tracking Monitoring Based on PMUT Arrays
As $a$ common and natural activity of human beings, eye movement has been regarded as an indicator of human physiological and psychological health; eye movement tracking has been applied to $a$ wide range of domains, such as disease diagnostics, drug therapy testing and human-computer interaction. Conventionally, eye movement is captured by three approaches, i.e., recording video using $a$ camera, measuring time-varying Electrooculography (EOG) signals using electrodes, and detecting reflected infrared light using infrared sensor. However, all these techniques incur certain limitations that impede their adoption for practical eye tracking, such as privacy violation, high computation resources, discomfort and strong light reliability. This paper presents $a$ portable and robust eye tracking technique based on ultrasound. Specifically, piezoelectric MEMS ultrasonic transducer arrays integrated on glasses are used to transmit and receive bio-safe pulse echo ultrasound individually. With experiment on volunteers, the developed devices can accurately track the rotation and direction of eyeball movement in real-time, based on the time of flight (TOF) principle. The tracking device is lightweight (< 25 mg) and compact (millimeters in size), showing $a$ great potential for wearable eye tracking application like virtual reality. [2021-0193]